Chapter 2
Quick start guide
This chapter guides you through the setup process for a basic project where a MWX65 wall panel
should be connected to an MTX series audio matrix. Make sure the audio matrix is installed correctly
and is powered off when connecting the MWX65 wall panel.
Connect the MWX65 wall panel to the Matrix system with a twisted pair CAT5 (or better) cabling with
a maximum cable length of 300 meters. Make sure the MWX65 is connected to one of the wall panel
inputs on the rear side of the MTX. It should be connected to the input of the zone where the local
audio input should be available. Go to the setup menu in the web based interface of the MTX and go to
System configuration. Click on MWX65 for making the settings.
An unique address should be selected for every connected wall panel. The address for a wall panel
always starts with the letter “W”. When only one wall panel is connected, the most logical way is to
start with address “W001”, and increase the address number for every additional wall panel. (“W002”
for wall panel 2, “W003” for wall panel 3, ...)