Automatic Technology EASYROLLER GDO-6AM User manual

EASYROLLER GDO-6AM Wiring and Installation Instructions
Battery Backup Kit
BATTERY BACKUP PACK GDO-6AM
SAP# ORDER NO. 87992
DESCRIPTION QTY DESCRIPTION QTY DESCRIPTION QTY
1 BATTERY PACK 1 5 SBC-02 CHARGER HARNESS EXT 1 9 SBY-2 BATTERY HARNESS 1
2 BATTERY HARNESS 1 6 CABLE CLAMP ACC-1.5 (3/16”) 1 10 TAPTITE SCREW “P” M4x8 4
3 TAPTITE “P” M3.5X 8 SCREWS 2 7 CHARGER BOARD SBC-02 1 11 TAPTITE SCREW “P” M4x10 2
4 PLASTER WALL PLUGS 2 8 SBC-02 CHARGER HARNESS 1 12 CABLE CLAMP ACC-1.5 (3/16”) 1
Doc # 160450_00
Part # 87996
Released 09/02/21
SPECIFICATIONS
APPROXIMATE NUMBER OF CYCLES UNDER BATTERY POWER 10
AVERAGE CYCLE TIME UNDER BATTERY POWER (OPENING AND CLOSING) 40 SECS
BATTERY CAPACITY (AMP HOURS) 1.3 AH
TIME FOR RE-CHARGE 24 HOURS
WARNING! AVERTISSEMENT!
• Disconnect the power cord from mains before connecting or
disconnecting the battery box, or making any repairs, or removing
covers.
• Servicing of batteries should be performed or supervised by personnel
knowledgeable about batteries and the required precautions.
• When replacing batteries, replace with the same type and number of
batteries or batteries packs.
• DO NOT short the output of batteries. Serious personal injury and/
or property damage can result from failure to follow this warning.
• During charging and discharging cycles the lead-acid batteries may
release explosive gases. Ensure that the area around the batteries is
well ventilated.
• Take care not to allow any metal objects to make contact with the
positive and negative terminals. This short circuit may cause sparks
battery and possible damage to the battery, or even cause an
explosion.
• Débrancher le cordon d’alimentation à partir de prise de courant
avant de connecter ou de déconnecter la boîte de la batterie, ou
d’effectuer toute réparation, ou d’enlever des couvercles.
• Entretien des batteries doit être effectué ou supervisé par du
personnel compétent au sujet de batteries et les précautions
requises.
• Lors du remplacement des batteries, remplacer par le même type et
le nombre de des batteries ou des batteries packs.
• NE PAS COURT la sortie des batteries. De sérieuses blessures et /
ou des dommages matériels peuvent résulter du non-respect de cet
avertissement.
• Durant les cycles de charge et de décharge des batteries plomb-
acide peuvent libérer des gaz explosifs. Veiller à ce que la zone
autour des batteries est bien ventilée.
• Prenez soin de ne pas laisser des objets métalliques à établir un
contact avec les bornes positives et négatives. Ce court-circuit peut
provoquer des étincelles batterie et de possibles dommages à la
batterie, ou même provoquer une explosion.
• The battery box unit should be installed away from sprinkler systems.
• DO NOT immerse in water or spray directly with a hose or other device.
• L’unité de boîte de la batterie doit être installé loin des systèmes de
gicleurs.
• NE PAS immerger dans l’eau ou pulvériser directement avec un tuyau
ou un autre dispositif.
• DO NOT dispose of batteries in a fire. The batteries may explode.
• The battery backup box contains sealed lead-acid batteries that must
be disposed of properly at the end of their useful life.
• DO NOT open or mutilate batteries. Released electrolyte is harmful to
the skin and eyes. It may be toxic.
• Be careful on the ladder. Practice correct lifting techniques.
• Ensure ladder is the correct type for job.
• Ensure ladder is on flat ground.
• DO NOT handle damaged or leaking batteries
• Wear appropriate protective clothing, use protective glasses and avoid
touching your face and eyes after working with batteries.
• NE PAS jetez batteries dans un feu. Les batteries peuvent exploser.
• La boîte de batterie de secours contient des batteries plomb-acide
scellées qui doivent être éliminés de façon appropriée à la fin de leur
vie utile.
• NE PAS ouvrir ni détériorer les batteries. L’électrolyte déversé est
dangereux pour la peau et les yeux. Il peut être toxique.
• Soyez prudent sur l’échelle. Pratiquer les techniques correcte de
levage.
• Veiller à l’échelle est le type correct pour le travail.
• Veiller à l’échelle est sur la terre plate.
• NE PAS manipuler les batteries abîmés ou qui fuient.
• Porter un vêtement de protection approprié, utiliser des lunettes de
protection et éviter de toucher votre visage et aux yeux après le travail
avec des batteries.
This warranty is to be read in conjunction with the
owner’s copy of the opener installation instruction.
WARRANTY
1 year

Symptom Possible cause Remedy
Door stops or moves very slowly
under battery power
Batteries may be weak or have no charge Connect mains power and allow the batteries to charge. This may
take 24 hours to reach maximum charge capacity.
Door will not operate when
mains power is disconnected.
Batteries may not be connected properly. Check wiring.
Batteries may have no charge Connect mains power and allow the batteries to charge. This may
take 24 hours to reach maximum charge capacity.
Faulty Batteries Disconnect the batteries from the board. Check the voltage of the
each battery. Voltage should not drop below 10V.
SBC-02
1
3
4
2
5
SBC-02
5
6
7
8
9
9
8
7
12
8
9
10
11
1
Opener Mounted
Wall Mounted
Opener Mounted
a. Unplug the drive unit from mains power.
b. Remove the timing cover and light diffuser.
c. Mount the Charger Board 7 on the chasis and secure with four (4)
Taptite ‘P’ M4x8 screws 10 .
d. Feed the battery harness 5 through the cable clamp 12 and
secure left corner of the board. Feed the Wire Harness 8 around
the timing assembly, through opening and plug into SBC-02
connector on the control board.
e. Remove breakaway slot on timing cover and feed wire battery
harness 9through slot and replace timing cover. Secure in place
with screws.
f. Mount battery backup kit 1 onto support chassis and secure right
side screw first (charger board side) 11 .
g. Position the wire battery harness 9neatly and secure left side of
battery kit with cable clamp 6.
Wall Mounted
a. Unplug the drive unit from mains power.
b. Remove the timing cover and light diffuser.
c. Mount the Charger Board 7 on the chasis and
secure with four (4) Taptite ‘P’ M4x8 screws 10 .
d. Feed the battery harness 5 through the cable
clamp 12 and secure left corner of the board.
Feed the Wire Harness 8 around the timing
assembly, through opening and plug into
SBC-02 connector on the control board.
e. Remove breakaway slot on timing cover and
feed wire battery harness 9through slot and
replace timing cover. Secure in place with
screws.
f. Connect the battery harness extension 5
plug to the battery harness 9as shown.
g. Position the wire battery harness 9neatly
and secure left side of battery kit with cable
clamp 6.
h. To wall mount - use the battery pack as
template to mark where to drill holes. Pre-drill
holes.
WARNING! After Step (h) the opener may become active
(even when power is off). This is a result of a residual charge
in the batteries.
AVERTISSEMENT! Après l’étape (b) l’opérateur peut
deviendra actif (même alimentation est éteinte). Ceci est un
résultat d’une charge résiduel dans les batteries.
(i) For plaster walls - insert (2) two plaster wall plugs 4into holes, place
battery backup kit over holes and affix with (2) two Taptite “P” M3.5
x 8 screws 3.
(ii) For brick walls - place the battery backup kit over the holes and affix
with (2) two Taptite “P” M3.5 x 8 screws 3.
WARNING! After Step (i) the opener may become active (even
when power is off). This is a result of a residual charge in the
batteries.
AVERTISSEMENT! Après l’étape (i) l’opérateur peut deviendra
actif (même alimentation est éteinte). Ceci est un résultat d’une
charge résiduel dans les batteries.
Troubleshooting
Testing / Maintenance
To ensure a long trouble free life for your battery backup it is recommended
you run the testing procedure on a monthly basis. Batteries should not need
replacing for 4 - 5 years.
Testing Procedure:
a. Press the transmitter to activate the opener.
b. Whilst the door is in motion disconnect power. The door should
complete the cycle as normal.
c. Wait for the door to finish is travel.
d. Press the transmitter to activate the opener.
e. Whilst the door is in motion reconnect power. If the door stopped
or moved very slowly under battery power, ensure mains power is
connected for 24 hours to recharge the batteries. Test the opener again
under battery power to ensure batteries are working effectively.
Automatic Technology America
3626 North Hall Street, Suite 610, Dallas, TX 75219, United States of America
P: +1 800 934 9892 W: www.ata-america.com
h. Connect battery harnesses 5 and 9together.
i. Close the light diffuser and reconnect power.
NOTE: Batteries may take up to 48 hours to charge fully after initial
installation.
j. Run the Testing / Maintenance procedure to test battery.
i. Connect battery harness 2to the harness extension 5.
j. Close the light diffuser and reconnect power.
NOTE: Batteries may take up to 24 hours to charge fully after initial
installation.
k. Run the Testing / Maintenance procedure to test battery.
Popular Camera Accessories manuals by other brands

Photogenic Professional Lighting
Photogenic Professional Lighting Skylighter CFF4 Operator's manual

FAAC
FAAC 700I instruction sheet

Hohem
Hohem iSTEADY X user manual

Moman
Moman Power 99S user manual

Energizer
Energizer Digital Camera Battery NH50 Product data sheet

Minolta
Minolta Extension Tube II owner's manual