44..048AA (System 44)
45..48AA (System 45)
Speed regulator for air ventilators with
push button dimmer
TECHNICAL CHARACTERISTICS
•Dimensions: 44..048AA 1 module System 44
45..48AA 1 module System 45
•Rated current: 230V ~ - 50Hz
•Controlled load: air ventilators, fans and exhausters with auxiliary phase
induction motors (*)
(*) The speed regulator is not to be used with:
- incandescent and halogen lamps
- fluorescent lamps
- toroidal transformers
- laminar transformers
- electronic power units
- drilling machines
- fan-coil motors
•Adjustable power: 55÷80VA
•Load switch on, regulation and switch off by built-in push button or
common, non luminous, parallel-connected NO push buttons
•Three-speed regulator + switch off
•Switch on sequence (always the same): minimum-medium-maximum-
switch off
•Blade speed: minimum speed ± 30% maximum speed, medium speed ±
50% maximum speed
•“Noiseless” technology
•Luminous front indicator for location in the dark: Led off = set maximum
speed
•Installation at maximum 60 m from controllable load
•Operating temperature: 0÷35°C
•Compliance to the standards:
- CEI EN 60669-2-1
- Directive BT
- Directive EMC
For flush-mounting installation use boxes with:
- 45 mm minimum depth for us 44..048AA
- 50 mm minimum depth for us 45..48AA
OPERATION
Press the front push button (or any other NO push button) to switch on at
minimum speed. Any time the push button is pressed, speed changes first
to minimum and then to maximum speed. Press again to switch it off.
The device can also be switched off during minimum or medium speed
operation by keeping the push button pressed for more than 0.5 seconds.
Switch on sequence is always the same: minimum speed - medium speed -
maximum speed - switch off, either when switch off occurs at the end of
this sequence or during minimum or medium speed operation.
Changes from switch off to minimum speed and from minimum speed to
medium speed are signalled by the front led switching off and on. Change
from medium to maximum speed is signalled by the front led switching off
while change from maximum speed to switch off is signalled by the front
led switching on again.
Note: the speed regulator can also be associated with air ventilators equip-
ped with chain for speed change by simply setting the maximum speed
with the chain and the following changes using our speed regulator.
NOTE
– Do not install more than one speed regulator in the same box
– Do not install two or more speed regulator in series
– Do not exceed the established rated output
– Install the speed regulator away from any heat source (thermostats or
chronothermostats).
WIRING DIAGRAM
Dimmer 44..048AA or 45..48AA must be associated with a fuse carrier (for
ex. 44..007 or 45..07) with high breaking capacity fuse as shown in the
following diagrams:
•Installation of the speed regulator only: changeover control and change
by built-in push button (figure 1)
•Speed regulator installed in association with NO push buttons:
changeover control and change by built-in push button or parallel-con-
nected normal push buttons (figure 2).
N.B.: the remote control push button line can be maximum 60 m long, which corresponds to
120 m circuit maximum length with 1.5 mm wire. For longer distance use an auxiliary relay.
C.489 - 04 - 270307
L
N
F
Legend
F: fuse type T0,8AH 250V~
Figure 1
L
N
F
Figure 2
IMPORTANT NOTES:
• Products should be sold in their original packaging. Otherwise, the retailer and/or
installer is obliged to follow, as well as to communicate to the user, the instructions
for use which are supplied with the product and/or are published on the website
www.ave.it as well as in the current product catalog.
• AVE products are installation products
• Products must be installed by trained professionals in compliance with the
installation regulations
• Once the product is unpacked, make sure that the appliance is undamaged. Do not
use the appliance if there is any doubt, but contact a qualified technician
• Even before unpacking, the appliance should be handled with care and stored in a
dry place at temperatures between –5°C and +40°C
• Before carrying out any maintenance on the appliance, cut off the mains power
• Special attention should be paid to the preparation of the cable terminals to be
inserted into the appliance terminals so as to maintain sufficient isolation distance
between contacts
• When tightening the terminal screws, special care should be taken to avoid
overheating which could start a fire or damage the cables.
• The product must be used in dry, dust-free areas
• Suitable products must be used in any other conditions
• There is a risk of electric shock or malfunction of the device if not handled properly.
• Install products and accessories according to the prescriptions in the catalogue
and the instructions sheet and in compliance with specific standards and rules
• Warranty certificate for a specific product, which specifies the warranty period and
conditions in accordance with local regulations, is issued by the seller at the moment
of sale of product
The manufacturer's warranty: The 5 year warranty applies only
to damaged or malfunctioning products caused by manufacturer’s
negligence, taking into account the rights and obligations
prescribed by law (art. 1490, 1512 C.C., DL 24/2002, Directive
1999/44/CE, art. 1519 C.C.). The defect must be notified within 2
month from the date it was discovered. Five years are intended from
the date of delivery of the product to the final customer.

This manual suits for next models

1

Other AVE Controllers manuals

AVE smart domina 442TC14-W User manual

AVE

AVE smart domina 442TC14-W User manual

AVE RC10 User manual

AVE

AVE RC10 User manual

AVE Domus 100 SISTEMA44 441048M User manual

AVE

AVE Domus 100 SISTEMA44 441048M User manual

Popular Controllers manuals by other brands

Harrison i-vent operating instructions

Harrison

Harrison i-vent operating instructions

Bondtech LGX Lite PRO How-to

Bondtech

Bondtech LGX Lite PRO How-to

National Instruments cRIO-9064 Getting started guide

National Instruments

National Instruments cRIO-9064 Getting started guide

Progeny P3 manual

Progeny

Progeny P3 manual

NXP Semiconductors K22F series Reference manual

NXP Semiconductors

NXP Semiconductors K22F series Reference manual

Timotion MA5 user manual

Timotion

Timotion MA5 user manual

EAS Electric ECRTH2 operating manual

EAS Electric

EAS Electric ECRTH2 operating manual

Sime C Series manual

Sime

Sime C Series manual

Omron CJ Series manual

Omron

Omron CJ Series manual

Parker Compax3 Fluid T40 operating instructions

Parker

Parker Compax3 Fluid T40 operating instructions

Nordson EFD ValveMate 7140 operating manual

Nordson EFD

Nordson EFD ValveMate 7140 operating manual

Omega OMB-PER-488/W95 user guide

Omega

Omega OMB-PER-488/W95 user guide

JL Audio MBT-CRX v2 user manual

JL Audio

JL Audio MBT-CRX v2 user manual

Philips dynalite DMRC210-RJ-DA installation instructions

Philips

Philips dynalite DMRC210-RJ-DA installation instructions

Metso Quadra-Powr II Installation maintenance and operating instructions

Metso

Metso Quadra-Powr II Installation maintenance and operating instructions

ASO Safety Solutions SK 35 operating manual

ASO Safety Solutions

ASO Safety Solutions SK 35 operating manual

RADEMACHER DuoFern 9471-2 instruction manual

RADEMACHER

RADEMACHER DuoFern 9471-2 instruction manual

Basler AVC634A-12 Operation manual

Basler

Basler AVC634A-12 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.