SPECIFICATIONS
Model AVR-D2-B1
Output CH A CH B
Amplitude (into 50 Ohms) 6 to 30 V, adjustable2. + or -, switchable 2 V, fixed. + or -, switchable
DC offset -15V to +15V, adjustable -1V to +1V, adjustable
Pulse width (FWHM) 200 ns to 20 us, adjustable 15 ns, fixed
Duty cycle 1% maximum N/A
Rise time of leading edge (10%-90%) ≤ 1.5 ns (≤ 1.0 ns optional3) ≤ 1.5 ns
Fall time of trailing edge (90%-10%) ≤ 2.0 ns ≤ 2.5 ns
Pulse repetition frequency (PRF) 5 Hz - 50 kHz
Source impedance 50 Ohms
Required load impedance 50 Ohms
GPIB and RS-232 control2Standard on -B units.
LabView Drivers Check http //www.avtechpulse.com/labview for availability and downloads
Ethernet port, for remote control using
VXI-11.3, ssh, telnet, & web
Included. Recommended as a modern alternative to GPIB / RS-232.
See http //www.avtechpulse.com/options/vxi for details.
Settings resolution The resolution of the timing parameters (pulse width, delay, period) varies,
but is always better than 0.15% of (|set value| + 20 ns).
The amplitude resolution is < 0.1% of the maximum amplitude.
Settings accuracy Typically ± 3% (±1 ns or ± 2% of max. amplitude) after 10 minute warmup. For high-accuracy
applications requiring traceable calibration, verify the output with a calibrated oscilloscope4.
Jitter ± 35 ps ± 0.015% of sync delay
Trigger modes Internal trigger, external trigger (TTL level pulse, > 50 ns, 1 kΩ input impedance),
front-panel “Single Pulse” pushbutton, or single pulse trigger via computer command.
Variable delay Sync to main out 0 to 1.0 seconds, for all trigger modes (including external trigger).
Sync output > +3 Volts, > 50 ns, will drive 50 Ohm loads
Monitor output Provides a 20 dB attenuated coincident replica of main output
Connectors BNC
Power required 100-240 Volts, 50-60 Hz
Dimensions, temperature range 100 x 430 x 375 mm (3.9 x 17 x 14.8”), +5°C to +40°C
1) -B suffix indicates IEEE-488.2 GPIB and RS-232 control of amplitude, pulse width, PRF and delay. (See http //www.avtechpulse.com/gpib).
2) The maximum amplitude may be increased from 30V to 40V by specifying the -SOA option.
3) Add the -TRF suffix to the model number to specify the ≤ 1.0 ns rise time option. Not available with the -SOA option.
4) These instruments are provided with a basic calibration checksheet, showing a selection of measured output parameters. These measurements are performed with
equipment that is calibrated on a regular basis by a third-party ISO/IEC 17025 2005 accredited calibration laboratory. However, Avtech itself does not claim any
accreditation. For applications requiring traceable performance, use a calibrated measurement system rather than relying on the accuracy of the pulse generator settings.