Avue G40 User manual

User Manual
English
v1.03
Middle Speed Dome
Camera Series

CONTENTS
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN
OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR
OTHER OPENINGS ON THE EQUIPMENT.
FCC COMPLIANCE STATEMENT
CE COMPLIANCE STATEMENT
CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY T H E PA RTY
RESPONSIBLE FOR COMPLIANCE COULD VOID THE USERS‘S AUTHORITY TO OPERATE THE
EQUIPMENT.
FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE
LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE
LIMITS ARE D E S I G H E N D TO PROVIDE R E A S O N A B L E PROTECTION AGAINST HAMRFUL
INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT. THIS
EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENGERGY AND IF NOT
INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE
HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN A
RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER
WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE.
WARNING: THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS
PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE
REQUIRED TO TAKE ADEQUATE MEASURES.
CAUTION: TO REDUCE THE RISK
OF ELECTRIC SHOCK, DO NOT
REMOVE COVER (OR BACK). NO
USER SERVICEABLE PARTS
INSIDE. JUST QUALIFIED
SERVICE PERSONNEL SHOULD
SERIVICE THE PRODUCT.
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature
accompanying this unit.
WARNING
CAUTION: BEFORE ATTEMPTING TO CONECT OR OPERATE THIS PRODUCT, PLEASE
READ THE LABEL ON THE BOTTOM AND USER'S MANUAL CAREFULLY
Technical specification are subjects to change without
prior notification. Manual may contain mistakes or print errors.
All trade marks mentioned belong to their respective owners.
1. Precaution...................................................... 1
2. Features......................................................... 2
3. Packing list..................................................... 3
4. Installation..................................................... 4
5. Operating the Speed Dome.............................. 9
6. OSD............................................................... 10
Map................................................................ 11
System Setting................................................ 12
Motion, Clear.................................................. 13
Camera Setting............................................... 14
Preset, Scan................................................... 15
Patterns, Tours............................................... 16
Zones and Privacy Mask................................... 17
7. Protocol Setting............................................... 18
8. Address ID...................................................... 19
9. Specifications................................................. 23

1.PRECAUTION
Refer all work related to the installaion of this product to qualified service
personnel or system installers.
Do not attemp to disassemble the appliance.
To prevent electric shock, do not remove screws or cover. There are no user-
serviceable parts inside. Contact qualified service personnel for maintenance.
Handle the appliance with care.
Do not strike or shake, as this may damage the appliance. It should be protected
against extreme pressure, vibration and humidity during transportation and storage.
Damages caused by improper transportation voids the warranty.
Do not use strong or abrasive detergents when cleaning the appliance body and
transparent cover.
Use a dry cloth to clean the appliance when dirty. When the dirt is hard to remove, use
a mild detergent and wipe gently.
Do not operate the apliance beyond its specified temperature, humidity or power
source ratings.
Do not use the dome camera in an extreme environment where high temperature or
high humidity exists.
Use the models within -20°C to +50°C(-40°F to 122°F) and a humidity below 90%.
The input power source is 24V AC, 50/60Hz and requires 1000mA.
Do not expose the indoor dome cameramodel to water or moisture, do not try to
operate it in wet areas.
Take immediate action when the indoor speed dome gets wet. Turn off the power and
refer servicing to qualified service personnel. Moisture may damage the appliance
and cause eletric shock.
Do not expose the camera lens directly to sunlight or other strong light sources.
This will cause permanent damage to the camera and voids the warranty.
Read this user's manual carefully before operating the appliance.
Make sure local electric safty standard are followed when using or installing the
appliance.
Do not install the camera in other orientation as designed.
Do not bend or squeez the sturcture, as this may damage the mechanic sturcture of
the appliance and voids the warranty.
Do not touch the cover with bare hands or any objects.
These will scratch the surface and negatively affect the image qulaity.
2.FEATURES
The middle speed dome camera series are designed for video surveillance
applications. The integrated, motorized pan-tilt mechanic allows users to maneuver the
camera to any position (360° horizontal and 180° vertical). Both series can be
equipped with digital zoom camera modules, which provide zooming function from 18
to 36 times (optical) and advanced image features.
Key features:
- 360° Pan and 180° Tilt range (90° with auto-image-flip)
- Support most well-known camera modules
- 128 preset points memory (80 can be used for auto tour function)
- 4 pattern tours
- 1 Scan tour
- Basic setup directly from keyboard
- Advanced setup through OSD (On Screen Display) menu
- Up to 24 privacy masking zones (despends on camera module)
- Multi-protocol through Rs485
- Direction indicator on screen
- Aluminum alloy structure with high intensity and heat-sinking
- High-precision step-motor for flicker-less image during movement
Camera Features:
-High resolution with 530TVL and Wide-Dynamic*
- Auto-Focus
- Auto-Iris
- Auto- Brightness control
- Auto-Balance
- IR cutter control, Day-Night mode switching
- Auto Slow-Shutter
Temperature monitoring and protection:
- Alarm notification will be displayed once the inner temperature exceeds the limit
- At -10 temperature area, the dome camera will start after the operation
temperature is reached
- Cooling fan activity is managed by the CPU ( extends the duration)
Other features:
- Proportional pan for Focus / Speed on different zoom factor
- Auto-resuming user-defined action, such as tour, pattern or scan after selectable idle
time
- Power-up Action activates tour or pattern by default
* depends on camera module type
°C
1 2
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details

3 4
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
3.PACKING LIST
Safety Instructions before starting
- Do not install and operate this appliance in a flammable and / or explosive environment.
- Make sure that the installation is done according to the local electricity safety
regulations of your country.
.
- Before installation and maintenance, make sure that the appliance is disconnected
from the power source.
- Do not use any power source other than 24V AC, in order to prevent damages to the
device. Please refer to the section "Precaution" for more details.
- Handle the device during the installation with care. Droping the product or extreme
vibration may cause irreparable damages and void the warranty.
- Do not install or operate the appliance close to high-voltage devices or high-voltage
cables. The safety distance should remain at least 50 m.
- To archive best image quality, it is recommanded to use underground cables shielded
by steel tube. Do not install the cable without any protection.
- In a thunderstorm area or region with high inductive voltage, such as high voltage
transformer stations, it is necessary to use additional lightning-proof equipment and/or
lightning robs for protection.
- For outdoor installations, lightning protection and grounding of the device should be
considered. Please refer to the industrial saftey regulations of your country.
.
- Grounding of the appliance should include anti-interference and fulfill the safety
requirements. Do not connect the ground with short-circuited or other high-voltage
electric networks.
- The resistance of down conductor should not exceed 4 Ohm, and its thickness should
be at least 25mm².
- This appliance has the lightning-proof function which can prevent damages caused by
high-voltage pulse, such as lightning strikes below 1500 V.
- This appliance meets the Ip66 standard for water and dust proof. Do not install the in-
door model for out-door applications as the model is not designed withstanding
permanent water exposure. Make sure that the installation is protected from long-time
water-drop or spatter, which may damage the appliance.
- Make sure that the enviroment of installation meets the requirements of the appliance,
such as holding the weight and providing enough space for bracket and power supply.
4.INSTALLATION
WARNING: The transparent cover part is sensitive and must
be handled with care. Do not touch or rub the surface in any way
with the protection foil.Inproper cleaning methods will cause
permanent scratches on the cover and cause unclear image or
focusing error of the camera. For cleaning the cover, replace
the original cover with the spare cover, then wash it by
immersing it into warm water containing a non-corrosive
cleaning agent.
Outdoor
Instruction and
operation manual
1 piece
USER'S MANUAL
Middle Sp eed do me
Camera S eri es

4.INSTALLATION
Connector description
Power
Connector
RS 485
Connector
RJ-11
Video output
BNC
RED : AC 24V
BLACK : AC 24V
To power supply
YELLOW : RS485 -
GREEN : Rs485 +
To keyboard or DVR devices for
telemetric control
Inner Conn : Signal +
Outer Conn : Ground
Video Output to monitor or DVR
Using optional accessories
The speed dome camera series can be connected to various optional accessories
through the standard connector types, which simplifiy the cable handling and avoid
possible mistakes. All accessories are tested for max. Compatibility and best
performance.
RS485 cable
The telemetric control of the appliance uses RS485 serial communication with half-
duplex transmission technology.
Depending on the cable type and baud rate, the transmission distance could vary. The
following table shows max. distances based on cable with 0,56mm (24AWG) twisted
pair:
2400 bps
1100 m
700m
400m
4800 bps
1700m
9600 bps
19200 bps
Baud Rate Max. Distance Due the environmental interferences, such as
eletromagnetic and induction fields, or number of
connected appliance on the RS485 bus, the
transmission range may decrease.
4.INSTALLATION
5 6
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
AC 230V
Power input
Power adaptor
AC 230V to AC 24V
AC 230V
Power input
AC 24 Power supply
3-Axis keyboard
controller
RS 485
Telemetric control
camera setup
21”High Res.
security monitor
Professional Real-time
16 Channel DVR
Video signal

4.INSTALLATION
4.INSTALLATION
The speed dome series provide an integrated termination switch. It should be
turned ON on the dome serving as the last device. If a controller keyboard is
used, you also need to turn the termination ON on the keyboard. Please refer to
the keyboard’s manual for details.
RS485 Termination
Devices using RS485 control are usually connected in daisy-chain which
reqiuers termination with 120Ω resistor on both ends. The following graphic
illustrates the connection methods. Please note that a daisy-chain connection
type shall not exceed 7 meters.
120Ω
Resistor
Device 2 Device 3Device 1
120Ω
Resistor
RS 485+
RS 485-
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
78
RS 485+
RS 485-
Termination on
Termination
on
Termination
off
Termination
off
Video Cable
Coaxial cable with 75 impedance with copper conductor at the center and shielded
with 95% copper. The following table shows different cable types and their maximum
length:
Ω
The values are for reference only.
Depending on the qualiy tof the cable and
environmental conditions the
transmission distance might decrease.
RG 6 /U
Cable standard
RG 11 /U
229m / 750 ft
Max. Distance (m /ft )
305m/ 1000 ft
457m / 1500 ft
RG 59 /U
Star-Connection
The star-form connection is a popular way to connect different devices. It enables
longer distance connection of different dome cameras. It is recommended to use
RS485 distributor to ensure the telemetric data transmission:
The advantage of star-connection is
that every channel can work
independently and supports a cable
length up to 1000 meters (depending on
the quality of the cable). In case more
dome cameras are installed, the star-
connection can be extended with
additional RS485 distributors.
Termination on
RS-48 5
Distr ibu tor
RS485 cable
up to 1000m
per channel
Termination
activated on
every end.
How to turn termination ON on the Dome
The termination switch is located on the rear side of the connection board. For
turning it ON open theconnector board.
If the cable length is more than 400 m, it is recommended to use optional accessories,
such as video amlifiersor twisted-pair video converters, to amplify the video signal.
Vid eo Amplifie r
(opti ona l)
Real ti me DV R Cen ter
(opti ona l)
High Re s Mon ito r
(opti ona l)
Up to 750m, coaxi al c able
Extend c on nection distance with
video am pl ifier
TP re ceive r
(opti ona l)
Real ti me DV R Cen ter
(opti ona l)
High Re s Mon ito r
(opti ona l)
Up to 1200m, twiste d pair or cat.5 cable
Extend c onnection distance with Twisted-Pair
video co nv erter
trans mit ter
(opti ona l)
Optional bracket accessories
The speed dome can be equipped with various bracket accessories for indoor and
outdoor installation. Please contact your distributor for further details.
Corner
mount
Pole
mount
Wall mount
Ceilling
mount
Wall
mount

Some products may not be available in your country, please contact our distributor for more detailsSome products may not be available in your country, please contact our distributor for more details
910
5.OPERATING THE SPEED DOME
FIRMWARE
Protocol: PELCO
Dome Address: 001
Comm 9600,N,8,1
V1.03
Initial Screen
After powering up, the camera will enter into
the self-test mode and display the status
screen (see picture left). It contains
information about the model and current
settings.
- “ ": Model number
- V1.03: Current firmware version
- Protocol: Control protocol which currently used
- Dome address: Address ID of speed dome. Please refer to the section "Protocol
setup " for details
- Comm 9600,N,8,1: Current setting of the serial communication interface
9600: Baud rate. Please refer to section "Baud-Rate setup" for details
N, 8, 1: No parity bit, 8 bit length, 1 stop bit. This setting cannot be changed
FIRMWARE
Operation Screen
The operation screen can display additional
information.
Temperature: Current temperature inside the speed
dome( °C)
Cam title: User definable camera title
Zone: Current zone name
Pan deg.: Pan angle, 0-359°
Tilt deg.: Tilt angle, 0-90°
Zoom Factor: Zoom factor
Display of the information can be activated or
deactivated through the OSD menu.Pplease refer to
the system setting for detais.
The intial screen will remain on until any user action is taken. If the power-up action is
set, the initial info wil vanish immediately.
32.0CAM TITLE
ZONE-1
285 78 18X
Pan degree
Zoom factor
Tilt degree
Zone description
Temperature
PTZ operation
For the surveillance operation, the dome can be controlled from a keyboard device,
Multiplexer or DVR through RS485 interface. Make sure that the cable is connected
and the settings (baud rate, Address ID and protocol) of both, keyboard and the dome,
are correctly configurated. For further details on operating the PTZ, please refer to the
user ’s manual of the keyboard.
OSD Menu
The dome camera are equipped with the new OSD Menu function. All operational functions
and camera related settings can be controlled here. In order to use the OSD function, a
telemetric controller device, such as keyboard, DVR or other devices with similiar functions,
is required. Please make sure that the device used is properly physically connected to the
dome and all connection parameters are set.
How to start the OSD Menu
To start the OSD Menu, you need to press the following sequence on the keyboard:
With or 2 X
With keyboard or 2 X
In case a DVR is used for operating the OSD, select “go to preset 95” or 2 X “go to preset 9”.
Please refer to the DVR’s operation manual for more details.
Note that in some situations, it is not possible to access the OSD menu:
1. The dome is running a tour
2. Performing PTZ operations
3. Dome is receiving a command other than OSD-request from the keyboard
To solve this inability stop the operation and try again.
keyboard
Shot 9 5 Enter
Main menu and navigation
Main Menu
SYSTEM SETTING
CAMERA SETTING
FUNCTION SETTING
WINDOW BLANKING
ALARM
EXIT
After entering the OSD Menu, the screen will show
menu items . Use the controller’s joystick to navigate
the menu’s main and sub items by moving in the
desired direction. The angle mark on the beginning of
every item indicates the selection.
UP, DOWN: - Moving between current menu items
- Changing the value in sub items
RIGHT: - Enter the selected menu item
- Confirm the value change and return
to
item selection
LEFT: - Exit from sub menu
For more inforamtion, please refer to the illustration on
Symbols and indicator
Cursor.
Sub item is selected. use up or down to change value
This item has subitem(s)
call 9 5 Enter call 9Enter
Shot 9Enter
6.OSD
( )3-Axis

Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
11 12
6.OSD - Map
MAI N M ENU
SY STE M SE TTI NG→
CA MER A SET TIN G→
FU NCT ION SET TIN G→
WI NDO W BL ANK ING →
EX IT
SY STE M SE TTI NG
ED IT D OME LAB EL→
IN ITI AL IN FO →
DI SPL AY SET UP→
MO TIO N→
CL EAR →
PASSWOR D SE TUP →
BA CK
EX IT
CA MER A SE TTI NG
ZO OM S PEE D HI GH
DI GITAL ZOO M OFF
BL C MO DE O FF
SL OW S HUT TER ON
IR CUT FILTE R AUT O
LI)NE SYN C OF F
WD R MO DE O FF
AD VANC E SE TT ING →
BA CK
EX IT
FU NCTIO N SET TING
AE MO D E AU T O
SHU T TE R N /A
IRI S N /A
BRI G HT N / A
WB MOD E A UT O
R GAI N N /A
B GAI N N /A
BAC K
EXI T
PRESETS
SCA N
S CA N S PE E D 20
S ET L E FT L I MI T
S ET R I GH T L IM I T
C LE A R SC A N
R UN S C AN
E DI T S CA N L AB E L→
B A C K
E X I T
→
→
PATTERNS
P AT T ER N N U MB E R 1
P RO G RA M P A TT E RN
R UN P A TT E R N
C LE A R PA T T ER N
E DI T P AT T E RN L A BE L→
BACK
EXIT
→
TOU R DW ELL 004
- - - -
RUN TOU R
BAC K
EXI T
00 00 00 00 0 0-00- 00 -00
00-00- 00-00-00-00- 00-00
00-00- 00-00-00-00- 00-00
ZON ES
Z ON E S NU M B ER 1
S ET L E FT L I M IT
S ET R I GH T L I MI T
C LE A R ZO N E
E DI T Z ON E L A BE L→
B A C K
E X I T
DOME LABEL OFF
PRESET LABEL OFF
ZOOM LABEL OFF
ZONE LABEL OFF
DIRECTION LABEL OFF
TEMPERATURE LABEL OFF
BACK
EXIT
MOT I ON
AUT O FLI P ON
PRO POR TIO N PAN O N
PAR K TIM E 000
PAR K ACT ION NONE
POW ER UP A CTI ON NONE
FAN E NAB LED 0 40
BAC K
EXI T
INI T IAL I N FO
SPE E D DO M E V1.03
PRO T OC O L :PELCO
DOM E A DD R ESS : 001
COM M : 960 0 . N .8. 1
BAC K
EXI T
P RE S ET N U M BE R 0 01
S ET P R ES E T
S HO W P RE S E T
C LE A R PR E S ET
E DI T P RE S E T LA B EL→
B A C K
E X I T
→
LAB E L: P R ESE T-0 1
BAC K
EXI T
EDI T P RES E T L ABE L
LAB E L: A U TO SC AN
BAC K
EXI T
ED IT S CAN LAB EL
LABEL: PATTERN-1
BAC K
EXI T
ED IT P ATT ERN LAB EL
LAB E L: Z O NE- 1
BACK
EXIT
ED IT Z ONE LAB EL
LABEL:SPEED DOME
BAC K
EXI T
1.00
EDI T D OME L A BE L
DIS P LAY S E TU P
ADV A NCE S E TT I NG
P R E S E T S →
S C A N →
P A T T E R N S →
T O U R →
ZONES→
BA CK
EX IT
CLE A R AL L Z ONE S
CLE A R AL L P RES ETS
CLE A R AL L P ATT ERN S
CLE A R AL L T OUR S
CLE A R AL L W IND OWS
FACTORY DEFAULTS
RESTART
BACK
EXIT
TOU R
WIN D OW N U MBE R 01
EDI T W IN D OW
ENA B LE W I NDO W OF F
CLE A R WI N DOW
BACK
EXIT
→
WIN D OW BL A NKI N G
6.OSD - System Setting
System Setting
In the system setting menu, you can modify operation
and display settings, such as dome label, temperature
and display of various values on the operational
screen.
EDI T DOM E LAB EL
LABEL: ENTRANCE
BACK
EXIT
INITI AL INFO
FIRMWARE V1.03
PROTOCOL:PLECO
DOME ADDRESS:001
COMM:4800,N,8,1
BACK
EXIT
SYSTEM SETTING
EDIT DOME LABEL
INITIAL INFO
DISPLAY SETUP
MOTION
CLEAR
PASSWORD SETUP
BACK
EXIT
Initial Info:
Shows the information about current settings.
Dome Label:
1. use UP or DOWN to change the character.
2. use RIGHT to move to next character.
3. use RIGHT to move to last char. and to save.
4. use Left to go to first char. and to cancel.
Display Setup
Enables the display for the on-screen info during
operaton mode.
Dome label: Name of the dome
Preset label: Shows the label of every preset
Zoom label: Shows zoom factor on screen
Zone label: Shows the zone name
Direction label: Shows the coordinates
Temperature label: Shows the current temp. in
the dome
DI SPLAY SETUP
DOME LABEL OFF
PRESET LABEL OFF
ZOOM LABEL OFF
ZONE LABEL OFF
DIRECTION LABEL O
TEMPERATURE LABEL OFF
BACK
FF
C L E A R

Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
13
6.OSD - Motion, Clear
14
MOTION Motion control
AUTO FLIP: Auto. image flip, tilt range from 90° to
180°.
PROPORTIONAL PAN: Depending on the zoom
factor, the dome will adjust the pan and tilt speed
automatically for comfortable viewing.
PARK TIME: Defines the idle time prior to start a
custom defined action (park action).The duration can
vary from 1 to 240 minutes. This function can
bedisabled by setting the minute to 0.
PARK ACTION: The action which will be started after
the idle time (park time). Selectable between Preset,
Scan, Pattern (Nr), Tour or None.
POWER UP ACTION: Action which starts after power
up and self test. Selectable between Auto, Preset 1,
Scan, Pattern (Nr), Tour or None. By selecting Auto,
the dome will resume the last action before power off.
FAN ENABLED: Defines the temperature limit (in °C)
at which the internal cooling starts operating. The
standard limit is 40°C.
AUTO FLIP ON
PROPORTION PAN ON
PARK TIME 000
PARK ACTION NONE
POWER UP ACTION NONE
FAN ENABLED 040
BACK
EXIT
Clear
You can clear setting’s memory or reset the camera to
factory default. The follwing functions are supported:
- Clear all zones
- Clear all presets
- Clear all patterns
- Clear all tours
- Clear all windows
- Factory defaults
Warning: The clear action cannot be undone.
Once an item is cleared it is impossible to
retrieve the deleted setting. Please make sure
that the requested clear action is desired.
CLEAR
CLEAR ALL ZONES
CLEAR ALL PRESETS
CLEAR ALL PATTERNS
CLEAR ALL TOURS
CLEAR ALL WINDOWS
FACTORY DEFAULTS
RESTART
BACK
EXIT
6.OSD - Camera Setting
ADVANCE SETTING
AE MODE AUTO
SHUTTER N/A
IRIS N/A
BRIGHT N/A
WB MODE AUTO
R GAIN N/A
B GAIN N/A
BACK
EXIT
Advanced Setting
Under the advanced setting, you can make
improvements tothe image quality depending on
different environmental conditions.
AE MODE: Auto Exposure mode. Depends on the light
condition in the surveillance area, you can set the AE in
different modes and adjust the parameters, such as
shutter speed, iris factor and brightness for the best
image quality.
WB MODE: White Balance mode, an image improvement
based on DSP processing. You can also adjust the Red-
Gain or Blue-Gain to change the color tone.
Hi-RESOLUTION: Switch between 470-530 TVL (only
with FCB-1010P)
ZOOM SPEED HIGH
DIGITAL ZOOM OFF
BLC MODE OFF
SLOW SHUTTER ON
IR CUT FILTER AUTO
LINE SYNC OFF
WDR MODE OFF
ADVANCE SETTING
BACK
EXIT
CAMERA SETTING
Camera Setting
In the camera setting menu, you can access camera module
related settings. Please note that depending on module’s
capability, some functions may not be available. Please
contact your local sales representative for detailed
information.
ZOOM SPEED: Defines the speed whith which zoom
functions are performed.
DIGITAL ZOOM: Activates or deactivates the camera
module’s digital zoom function.
BLC MODE: Selects the Back Light Compensation mode
which improves the image when an object has strong back
light.
SLOW SHUTTER: Activates the Slow Shutter function of the
camera, which provides a higher light sensibility in low-lit
environments.
IR CUT FILTER: Enables the removal of Infrared Cutter
Filter (IRC), also known as “DAY/NIGHT” mode. Enabling
the IRC the camera turns into Black/White mode and has
higher sensibility to low-light situations or turns on the IR-
light, depending on the light condition. Selectable between
On, Off or Auto. Only available on camera modules with IRC
function.
LINE SYNC: Enables and disables Line Synchronization.

Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
6.OSD - Preset, Scan
15
Function Setting
In function setting menu, you can define and activate
different PTZ funcitons, such as preset points, auto
scan, tours and patterns. Presets and tour functions
can also be set or activated directly from the
keyboard without entering the OSD Menu. Please
refer to the keyboard’s manual for operation details.
ED IT PR ESET LA BEL
LABEL:MAIN ENTR
BACK
EXIT
FU NCT ION SET TIN G
PRESETS
SCAN
PATTERNS
TOUR
ZONES
BACK
EXIT
Presets
PRESET NUMBER: supports up to 128 presets. The
number can be selected from 0 to 128.
SET PRESET: Defining the preset points directly in
OSD by entering this menu item and move the PTZ.
Press IRIS-OPEN key on the keyboard to save. If the
preset is pointed within digital zoom, it will
automatically go back to the max. optical zoom range
in order to provide the best image quality.
SHOW PRESET: Moves to the current preset point.
CLEAR PRESET: Clears the current preset.
EDIT PRESET LABEL: For the current preset, you
can define a name which will be displayed on the
operation screen once the preset is called. Please
choose the preset number first. The avaialbe
characters are: 0-9, A-Z, <,>,. and space.
PRE SET S
P R ESE T NU M B E R 0 01
SET PRESET
S H O W P R E S E T
C L E A R P R E S E T
E D I T P R E S E T L A B E L
B A C K
EX IT
Scan
The SCAN function moves the PTZ between 2-
predefined points with constant speed. The following
parameters can be set:
SCAN NUMBER: Supports up to 4 scans.
SCAN SPEED: Cruising speed between the points.
SET LEFT LIMIT: Defines the left point.
SET RIGHT LIMIT: Defines the right point.
CLEAR SCAN: Deletes the scan setting.
RUN SCAN: Starts the scan function.
EDIT SCAN LABEL:Sets the name for the scan.
SCA N
SCAN SPEED 20
SET LEFT LIMIT
SET RIGHT LIMIT
CLEAR SCAN
RUN SCAN
EDIT SCAN LABEL
BACK
EXIT
16
6.OSD - Patterns, Tours
Patterns
Patterns record the user ’s movement while
performing PTZ operations and stores them as a
track. The Speed Dome can record up to 4 tracks
with max. 180 sec. each.
PATTERN NUMBER: Supports up to 4 patterns.
PROGRAM PATTERN: Starts recording the
pattern when selected. You can perfom PTZ
movements for recording (not exceeding 180 sec.).
Press IRIS-OPEN to save the track.
RUN PATTERN: Starts the current pattern.
CLEAR PATTERN: Deletes the current pattern.
EDIT PATTERN LABEL : Sets the name for the
current pattern.
Tour
Tour is an auto-operation running through selected
preset points with definable pause time. A tour can
store up to 24 preset points.
TOUR DWELL (TM): Pause duration after reaching
a preset point. Duration can be set between 00-
255(s).
RUN TOUR: Starts the tour and exits the OSD
Menu.
TOUR
PAT TER NS
PATTERN NUMBER 1
PROGRAM PATTERN
RUN PATTERN
CLEAR PATTERN
EDIT PATTERN LABEL
BACK
EXIT
TOUR DWELL 004
00-0 00-00
BACK
EXIT
0- -00-00-00-00
00-00-00-00-00-00-00-00
00-00-00-00-00-00-00-00
RUN TOUR

Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
6.OSD - Zones and Privacy Mask
17
Zones
You can define the zones in the whole PT range up to
8 zones. When the display setting “Zone Label” is
activated, its label will be displayed on the screen.
The defined ranges of the zones should not be
overlapping.
ZONE NUMBER: Supports up to 8 zones.
SET LEFT LIMIT: Left boarder of the current zone.
SET RIGHT LIMIT: Right boarder of the current zone.
CLEAR ZONE: Delet the current zone.
EDIT ZONE LABEL : Changes the label (name) of the
current zone.
ZONES
ZONE NUMBER 1
SET LEFT LIMIT
SET RIGHT LIMIT
CLEAR ZONE
EDIT ZONE LABEL
BACK
EXIT
Privacy Mask (Window Blanking)
Privacy Mask is used to protect the privacy area that
should not be displayed once the camera is pointed
on it, such as lavatory areas or the operation desk of
an ATM machine. This might be mandatory required
by local law regulations. The Speed Dome supports
up to 24 private masks (depending on the installed
camera module; please contact your local sales
representative for more information).
Hitachi camera modules: 8 masking areas
Sony Camera modules: up to 24 masking areas
(except the 45 series provides only 8)
LG,CNB Camera modules: no masking function
WINDOW NUMBER: Mask number.
EDIT WINDOW: Edit position of the mask using the
keyboard’s joystick. Presse IRIS-OPEN to save.
ENABLE WINDOW: Shows the mask on the screen.
CLEAR WINDOW: Deletes the mask.
WINDOW BLANKING
WINDOW NUMBER 01
EDIT WINDOW
ENABLE WINDOW OFF
CLEAR WINDOW
BACK
EXIT
7.PROTOCOL SETTING
Protocol Setting
This procedure is needed if a connection of the
telemetric control with the keyboard device is
desired. You need to setup the dome address and
protocol settings.
The speed dome support multiple communication
protocols. The settings can be changed by
rearranging the DIP-Switches on the rear side of
the connector board as illustrated.
Please use the following table for detailed
information.
Baud rate DIP 7 DIP8
2400 bps 0 0
4800 bps 1 0
9600 bps 0 1
19200 bps 1 1
SW 1:
Represents the dome’s address in binary form.
Please refer to the list on the next pages for
reference.
SW 2:
Used for protocol settting and baud rate.
DIP 1 to 6 : Protocol settings
DIP 7 and 8:Baud rate settings
B02 0 0 1 1 0 0
DIAMOND 1 0 0 1 0 0
HUNDA 1 0 1 1 0 0
KALATEL 0 1 0 1 0 0
LILIN 1 1 0 1 0 0
MOLYNX 0 0 1 0 0 0
PANASONIC 1 1 1 0 0 0
PELCO (D/P) 1 0 0 0 0 0
PHILIPS 0 0 0 0 0 1
SAE 0 1 0 0 0 0
SAMSUNG 0 0 0 1 0 0
SANTACHI 0 1 1 0 0 0
UNIVISION 0 1 0 0 0 1
VCL 1 1 0 0 0 0
VICON 1 0 1 0 0 0
AD 0 0 1 1 0 0
Protocol / DIP 1 2 3 4 5 6

Some products may not be available in your country, please contact our distributor for more details
8. Address ID, 1 to 67
8 0 0 0 1 0 0 0 0 42 0 1 0 1 0 1 0 0
9 1 0 0 1 0 0 0 0 43 1 1 0 1 0 1 0 0
10 0 1 0 1 0 0 0 0 44 0 0 1 1 0 1 0 0
11 1 1 0 1 0 0 0 0 45 1 0 1 1 0 1 0 0
12 0 0 1 1 0 0 0 0 46 0 1 1 1 0 1 0 0
13 1 0 1 1 0 0 0 0 47 1 1 1 1 0 1 0 0
14 0 1 1 1 0 0 0 0 48 0 0 0 0 1 1 0 0
15 1 1 1 1 0 0 0 0 49 1 0 0 0 1 1 0 0
16 0 0 0 0 1 0 0 0 50 0 1 0 0 1 1 0 0
17 1 0 0 0 1 0 0 0 51 1 1 0 0 1 1 0 0
18 0 1 0 0 1 0 0 0 52 0 0 1 0 1 1 0 0
19 1 1 0 0 1 0 0 0 53 1 0 1 0 1 1 0 0
20 0 0 1 0 1 0 0 0 54 0 1 1 0 1 1 0 0
21 1 0 1 0 1 0 0 0 55 1 1 1 0 1 1 0 0
22 0 1 1 0 1 0 0 0 56 0 0 0 1 1 1 0 0
23 1 1 1 0 1 0 0 0 57 1 0 0 1 1 1 0 0
24 0 0 0 1 1 0 0 0 58 0 1 0 1 1 1 0 0
25 1 0 0 1 1 0 0 0 59 1 1 0 1 1 1 0 0
26 0 1 0 1 1 0 0 0 60 0 0 1 1 1 1 0 0
27 1 1 0 1 1 0 0 0 61 1 0 1 1 1 1 0 0
28 0 0 1 1 1 0 0 0 62 0 1 1 1 1 1 0 0
29 1 0 1 1 1 0 0 0 63 1 1 1 1 1 1 0 0
30 0 1 1 1 1 0 0 0 64 0 0 0 0 0 0 1 0
31 1 1 1 1 1 0 0 0 65 1 0 0 0 0 0 1 0
32 0 0 0 0 0 1 0 0 66 0 1 0 0 0 0 1 0
33 1 0 0 0 0 1 0 0 67 1 1 0 0 0 0 1 0
Swit c hnumb e r (Sw1) Swit c hnumb e r (Sw1)
Bit 1 2 3 4 5 6 7 8 Bit 1 2 3 4 5 6 7 8
1 1 0 0 0 0 0 0 0 35 1 1 0 0 0 1 0 0
2 0 1 0 0 0 0 0 0 36 0 0 1 0 0 1 0 0
3 1 1 0 0 0 0 0 0 37 1 0 1 0 0 1 0 0
4 0 0 1 0 0 0 0 0 38 0 1 1 0 0 1 0 0
5 1 0 1 0 0 0 0 0 39 1 1 1 0 0 1 0 0
6 0 1 1 0 0 0 0 0 40 0 0 0 1 0 1 0 0
7 1 1 1 0 0 0 0 0 41 1 0 0 1 0 1 0 0
ID ID
0 0 0 0 0 0 0 0 0 1 0 0 0 1 0 034
Some products may not be available in your country, please contact our distributor for more details
10 2
10 3
10 4
10 5
10 6
10 7
10 8
10 9
11 0
11 1
11 2
11 3
11 4
11 5
11 6
11 7
11 8
11 9
12 0
12 1
12 2
12 3
12 4
12 5
12 6
12 7
12 8
12 9
13 0
13 1
13 2
13 3
13 4
13 5
101
100
99
98
96
97
95
94
93
92
91
90
89
87
88
86
85
84
83
82
72
81
80
79
78
77
76
75
74
73
71
70
69
68
Bit 1 2 3 4 5 6 7 8 Bit 1 2 3 4 5 6 7 8
0 0 1 0 0 0 1 0 0 1 1 0 0 1 1 0
1 0 1 0 0 0 1 0 1 1 1 0 0 1 1 0
0 1 1 0 0 0 1 0 0 0 0 1 0 1 1 0
1 1 1 0 0 0 1 0 1 0 0 1 0 1 1 0
0 0 0 1 0 0 1 0 0 1 0 1 0 1 1 0
1 0 0 1 0 0 1 0 1 1 0 1 0 1 1 0
0 1 0 1 0 0 1 0 0 0 1 1 0 1 1 0
1 1 0 1 0 0 1 0 1 0 1 1 0 1 1 0
0 0 1 1 0 0 1 0 0 1 1 1 0 1 1 0
1 0 1 1 0 0 1 0 1 1 1 1 0 1 1 0
0 1 1 1 0 0 1 0 0 0 0 0 1 1 1 0
1 1 1 1 0 0 1 0 1 0 0 0 1 1 1 0
0 0 0 0 1 0 1 0 0 1 0 0 1 1 1 0
1 0 0 0 1 0 1 0 1 1 0 0 1 1 1 0
0 1 0 0 1 0 1 0 0 0 1 0 1 1 1 0
1 1 0 0 1 0 1 0 1 0 1 0 1 1 1 0
0 0 1 0 1 0 1 0 0 1 1 0 1 1 1 0
1 0 1 0 1 0 1 0 1 1 1 0 1 1 1 0
0 1 1 0 1 0 1 0 0 0 0 1 1 1 1 0
1 1 1 0 1 0 1 0 1 0 0 1 1 1 1 0
0 0 0 1 1 0 1 0 0 1 0 1 1 1 1 0
1 0 0 1 1 0 1 0 1 1 0 1 1 1 1 0
0 1 0 1 1 0 1 0 0 0 1 1 1 1 1 0
1 1 0 1 1 0 1 0 1 0 1 1 1 1 1 0
0 0 1 1 1 0 1 0 0 1 1 1 1 1 1 0
1 0 1 1 1 0 1 0 1 1 1 1 1 1 1 0
0 1 1 1 1 0 1 0 0 0 0 0 0 0 0 1
1 1 1 1 1 0 1 0 1 0 0 0 0 0 0 1
0 0 0 0 0 1 1 0 0 1 0 0 0 0 0 1
1 0 0 0 0 1 1 0 1 1 0 0 0 0 0 1
0 1 0 0 0 1 1 0 0 0 1 0 0 0 0 1
1 1 0 0 0 1 1 0 1 0 1 0 0 0 0 1
0 0 1 0 0 1 1 0 0 1 1 0 0 0 0 1
1 0 1 0 0 1 1 0 1 1 1 0 0 0 0 1
ID ID
Swit chnum ber (S w 1) Switc h numb e r (Sw1 )
8.Address ID, 68 to 135

Some products may not be available in your country, please contact our distributor for more details
8. Address ID, 136 to 203
190
191
192
193
194
19 5
196
197
198
199
200
201
202
203
16 9
16 8
16 7
16 6
16 5
16 4
16 3
16 2
16 1
16 0
15 9
15 8
15 7
15 6
15 5
15 4
15 3
138
139
140
141
142
143
14 4
14 5
14 6
14 7
14 8
14 9
15 0
15 1
15 2
189
188
187
186
185
184
183
182
181
180
179
178
177
176
175
174
173
172
171
170
137
136
Bit 1 2 3 4 5 6 7 8 Bit 1 2 3 4 5 6 7 8
0 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1
1 0 0 1 0 0 0 1 1 1 0 1 0 1 0 1
0 1 0 1 0 0 0 1 0 0 1 1 0 1 0 1
1 1 0 1 0 0 0 1 1 0 1 1 0 1 0 1
0 0 1 1 0 0 0 1 0 1 1 1 0 1 0 1
1 0 1 1 0 0 0 1 1 1 1 1 0 1 0 1
0 1 1 1 0 0 0 1 0 0 0 0 1 1 0 1
1 1 1 1 0 0 0 1 1 0 0 0 1 1 0 1
0 0 0 0 1 0 0 1 0 1 0 0 1 1 0 1
1 0 0 0 1 0 0 1 1 1 0 0 1 1 0 1
0 1 0 0 1 0 0 1 0 0 1 0 1 1 0 1
1 1 0 0 1 0 0 1 1 0 1 0 1 1 0 1
0 0 1 0 1 0 0 1 0 1 1 0 1 1 0 1
1 0 1 0 1 0 0 1 1 1 1 0 1 1 0 1
0 1 1 0 1 0 0 1 0 0 0 1 1 1 0 1
1 1 1 0 1 0 0 1 1 0 0 1 1 1 0 1
0 0 0 1 1 0 0 1 0 1 0 1 1 1 0 1
1 0 0 1 1 0 0 1 1 1 0 1 1 1 0 1
0 1 0 1 1 0 0 1 0 0 1 1 1 1 0 1
1 1 0 1 1 0 0 1 1 0 1 1 1 1 0 1
0 0 1 1 1 0 0 1 0 1 1 1 1 1 0 1
1 0 1 1 1 0 0 1 1 1 1 1 1 1 0 1
0 1 1 1 1 0 0 1 0 0 0 0 0 0 1 1
1 1 1 1 1 0 0 1 1 0 0 0 0 0 1 1
0 0 0 0 0 1 0 1 0 1 0 0 0 0 1 1
1 0 0 0 0 1 0 1 1 1 0 0 0 0 1 1
0 1 0 0 0 1 0 1 0 0 1 0 0 0 1 1
1 1 0 0 0 1 0 1 1 0 1 0 0 0 1 1
0 0 1 0 0 1 0 1 0 1 1 0 0 0 1 1
1 0 1 0 0 1 0 1 1 1 1 0 0 0 1 1
0 1 1 0 0 1 0 1 0 0 0 1 0 0 1 1
1 1 1 0 0 1 0 1 1 0 0 1 0 0 1 1
0 0 0 1 0 1 0 1 0 1 0 1 0 0 1 1
1 0 0 1 0 1 0 1 1 1 0 1 0 0 1 1
ID ID
Switchnumber (Sw1)Switchnumber (Sw1)
Some products may not be available in your country, please contact our distributor for more details
23 7
23 6
23 5
23 4
23 3
25 5
25 4
25 3
25 2
25 1
25 0
24 9
24 8
24 7
24 6
24 5
24 4
24 3
24 2
24 1
24 0
23 9
23 8
23 2
23 1
23 0
22 9
22 8
22 7
22 6
22 5
22 4
22 3
22 2
22 1
22 0
21 9
21 8
21 7
21 6
21 5
21 4
21 3
21 2
21 1
21 0
20 9
20 8
20 7
20 6
20 5
20 4
Switchnumber (Sw1)
(Bit ) 1 2 3 4 5 6 7 8
0 0 1 1 0 0 1 1 0 1 1 1 0 1 1 1
1 0 1 1 0 0 1 1 1 1 1 1 0 1 1 1
0 1 1 1 0 0 1 1 0 0 0 0 1 1 1 1
1 1 1 1 0 0 1 1 1 0 0 0 1 1 1 1
0 0 0 0 1 0 1 1 0 1 0 0 1 1 1 1
1 0 0 0 1 0 1 1 1 1 0 0 1 1 1 1
0 1 0 0 1 0 1 1 0 0 1 0 1 1 1 1
1 1 0 0 1 0 1 1 1 0 1 0 1 1 1 1
0 0 1 0 1 0 1 1 0 1 1 0 1 1 1 1
1 0 1 0 1 0 1 1 1 1 1 0 1 1 1 1
0 1 1 0 1 0 1 1 0 0 0 1 1 1 1 1
1 1 1 0 1 0 1 1 1 0 0 1 1 1 1 1
0 0 0 1 1 0 1 1 0 1 0 1 1 1 1 1
1 0 0 1 1 0 1 1 1 1 0 1 1 1 1 1
0 1 0 1 1 0 1 1 0 0 1 1 1 1 1 1
1 1 0 1 1 0 1 1 1 0 1 1 1 1 1 1
0 0 1 1 1 0 1 1 0 1 1 1 1 1 1 1
1 0 1 1 1 0 1 1 1 1 1 1 1 1 1 1
0 1 1 1 1 0 1 1
1 1 1 1 1 0 1 1
0 0 0 0 0 1 1 1
1 0 0 0 0 1 1 1
0 1 0 0 0 1 1 1
1 1 0 0 0 1 1 1
0 0 1 0 0 1 1 1
1 0 1 0 0 1 1 1
0 1 1 0 0 1 1 1
1 1 1 0 0 1 1 1
0 0 0 1 0 1 1 1
1 0 0 1 0 1 1 1
0 1 0 1 0 1 1 1
1 1 0 1 0 1 1 1
0 0 1 1 0 1 1 1
1 0 1 1 0 1 1 1
ID ID
Swit chnum ber (S w 1)
(Bit ) 1 2 3 4 5 6 7 8
8. Address ID, 204 to 255

Some products may not be available in your country, please contact our distributor for more details
23
Tilt Range
Communication
Preset Positions
Auto Pan
Tour / Sequence
Operating Temp.
Power
0 - 90°
RS485, multiple-protocol, coax
128 Presets
Yes, between 2 presets
4 progr. Tours with max 24 presets/ 4 Pattern up to 180s
-20°C to 50°C
24V AC / 24 -60 VA
Tilt Speed
Pan Range
0° - 100° per Sec.
360°
Iris Control
Gain Control
Video Output
S/N Ratio
Pan Speed
Auto / Manua/ Auto Slow Shutter
LOW / MEDIUN / HIGH / MANUAL / OFF
CVBS : 1.0Vp-p/75Ω
0° - 100° per Sec.
Shutter Speed 1 to 1/10,000 Sec. 1/3 to 1/10,000 Sec.
Focus
White Balance
Auto / Manual
Auto / Manual (ATW, Indoor, Outdoor, One Push WB, Manual WB)
Viewing Angle
Image Sensor 1/4 inch,super HAD color CCD
Model
Signal Format
Scanning
PAL / NTSC
2:1 Interlace
H. Resolution 550 TV Lines(Min.) :Color / 680 TV Lines(Min.) : B/W
H: Appr. 55.5°(Wide) to 1.59°(Tele)
V: Appr.42.5°(Wide) to 1.19°(Tele)
Zoom
Min. Illumination
27× Opt. / 12× Digital 37× Opt. / 12× Digital
0.4 Lux/F1.6 (50 IRE) : Color / 0.02 Lux/F1.6 (50 IRE): B/W
-
More than 50 dB
9.SPECIFICATION
27X 37X
H: Appr.55.5°(Wide) to 2.24°(Tele)
V: Appr.55.5°(Wide)to1.79°(Tele)
Table of contents
Other Avue Security Camera manuals

Avue
Avue AV762FTBA-2812 User manual

Avue
Avue AVHD830IR User manual

Avue
Avue AV665PIRW User manual

Avue
Avue G25-S10SAN User manual

Avue
Avue AV666EW User manual

Avue
Avue AU-G50VL-WB18 User manual

Avue
Avue G1085PIRW User manual

Avue
Avue AV666EW User manual

Avue
Avue G55IR-WB36N User manual

Avue
Avue AV830SDIR User manual