Axis A1001 User manual

USERMANUAL
AXISA1001NetworkDoorController&AXISEntryManager

AboutthisDocument
Thismanualisintendedforadministratorsandusersof
AXISA1001NetworkDoorControllerandisapplicableto
AXISEntryManagerandrmware1.15andlater.Itincludes
instructionsforusingandmanagingtheproductonyournetwork.
Previousexperienceofnetworkingwillbeofusewhenusingthis
product.SomeknowledgeofUNIXorLinux-basedsystemsmayalsobe
benecial,fordevelopingshellscriptsandapplications.Laterversions
ofthisdocumentwillbepostedtotheAxiswebsite,asrequired.See
alsotheproduct’sonlinehelp,availableviatheweb-basedinterface.
Inthismanual,AXISA1001NetworkDoorControllerisreferredtoas:
theAxisproduct,product,networkdoorcontroller,anddoorcontroller.
Liability
Everycarehasbeentakeninthepreparationofthisdocument.Please
informyourlocalAxisofceofanyinaccuraciesoromissions.Axis
CommunicationsABcannotbeheldresponsibleforanytechnicalor
typographicalerrorsandreservestherighttomakechangestothe
productandmanualswithoutpriornotice.AxisCommunicationsAB
makesnowarrantyofanykindwithregardtothematerialcontained
withinthisdocument,including,butnotlimitedto,theimplied
warrantiesofmerchantabilityandtnessforaparticularpurpose.Axis
CommunicationsABshallnotbeliablenorresponsibleforincidentalor
consequentialdamagesinconnectionwiththefurnishing,performance
oruseofthismaterial.Thisproductisonlytobeusedforitsintended
purpose.
IntellectualPropertyRights
AxisABhasintellectualpropertyrightsrelatingtotechnologyembodied
intheproductdescribedinthisdocument.Inparticular,andwithout
limitation,theseintellectualpropertyrightsmayincludeoneormore
ofthepatentslistedatwww.axis.com/patent.htmandoneormore
additionalpatentsorpendingpatentapplicationsintheUSandother
countries.
ThisproductcontainssourcecodecopyrightAppleComputer,
Inc.,underthetermsofApplePublicSourceLicense2.0(see
www.opensource.apple.com/apsl).Thesourcecodeisavailablefrom
https://developer.apple.com/bonjour/
EquipmentModications
Thisequipmentmustbeinstalledandusedinstrictaccordancewiththe
instructionsgivenintheuserdocumentation.Thisequipmentcontains
nouser-serviceablecomponents.Unauthorizedequipmentchangesor
modicationswillinvalidateallapplicableregulatorycertications
andapprovals.
TrademarkAcknowledgments
AXISCOMMUNICATIONS,AXIS,ETRAX,ARTPECandVAPIXare
registeredtrademarksortrademarkapplicationsofAxisABinvarious
jurisdictions.Allothercompanynamesandproductsaretrademarksor
registeredtrademarksoftheirrespectivecompanies.
RegulatoryInformation
Europe
ThisproductcomplieswiththeapplicableCEmarkingdirectives
andharmonizedstandards:
•ElectromagneticCompatibility(EMC)Directive2004/108/EC.See
ElectromagneticCompatibility(EMC),onpage2.
•LowVoltage(LVD)Directive2006/95/EC.SeeSafety,onpage2.
•RestrictionsofHazardousSubstances(RoHS)Directive2011/65/EU.
SeeDisposalandRecycling,onpage2.
Acopyoftheoriginaldeclarationofconformitymaybeobtainedfrom
AxisCommunicationsAB.SeeContactInformation,onpage3.
ElectromagneticCompatibility(EMC)
Thisequipmenthasbeendesignedandtestedtofulllapplicable
standardsfor:
•Radiofrequencyemissionwheninstalledaccordingtothe
instructionsandusedinitsintendedenvironment.
•Immunitytoelectricalandelectromagneticphenomenawhen
installedaccordingtotheinstructionsandusedinitsintended
environment.
USA
Thisequipmenthasbeentestedusingashieldednetworkcable(STP)
andfoundtocomplywiththelimitsforaClassBdigitaldevice,
pursuanttopart15oftheFCCRules.Theselimitsaredesigned
toprovidereasonableprotectionagainstharmfulinterferenceina
residentialinstallation.Thisequipmentgenerates,usesandcanradiate
radiofrequencyenergyand,ifnotinstalledandusedinaccordance
withtheinstructions,maycauseharmfulinterferencetoradio
communications.However,thereisnoguaranteethatinterference
willnotoccurinaparticularinstallation.Ifthisequipmentdoes
causeharmfulinterferencetoradioortelevisionreception,which
canbedeterminedbyturningtheequipmentoffandon,theuseris
encouragedtotrytocorrecttheinterferencebyoneormoreofthe
followingmeasures:
•Reorientorrelocatethereceivingantenna.
•Increasetheseparationbetweentheequipmentandreceiver.
•Connecttheequipmentintoanoutletonacircuitdifferentfrom
thattowhichthereceiverisconnected.
•Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
Theproductshallbeconnectedusingashieldednetworkcable(STP)
thatisproperlygrounded.
Canada
ThisClassBdigitalapparatuscomplieswithCanadianICES-003.The
productshallbeconnectedusingashieldednetworkcable(STP)thatis
properlygrounded.
CetappareilnumériquedelaclasseBestconfomeàlanorme
NMB-003duCanada.Leproduitdoitêtreconnectéàl'aided'uncâble
réseaublindé(STP)quiestcorrectementmisàlaterre.
Europe
ThisdigitalequipmentfulllstherequirementsforRFemission
accordingtotheClassBlimitofEN55022.Theproductshallbe
connectedusingashieldednetworkcable(STP)thatisproperly
grounded.
Thisproductfulllstherequirementsforimmunityaccording
toEN61000-6-1residential,commercialandlight-industrial
environments.
Thisproductfulllstherequirementsforimmunityaccordingto
EN61000-6-2industrialenvironments.
Thisproductfulllstherequirementsforimmunityaccordingto
EN55024ofceandcommercialenvironments
Thisproductfulllstherequirementsforimmunityaccordingto
EN50130-4residential,commercial,light-industrialandindustrial
environments.
Australia/NewZealand
ThisdigitalequipmentfulllstherequirementsforRFemission
accordingtotheClassBlimitofAS/NZSCISPR22.Theproductshall
beconnectedusingashieldednetworkcable(STP)thatisproperly
grounded.
Japan
この装置は、クラスB情報技術装置です。この装置は、家
庭環境で使用することを目的としていますが、この装置が
ラジオやテレビジョン受信機に近接して使用されると、受
信障害を引き起こすことがあります。取扱説明書に従って
正しい取り扱いをして下さい。本製品は、シールドネット
ワークケーブル(STP)を使用して接続してください。また
適切に接地してください。
Safety
ThisproductcomplieswithIEC/EN/UL60950-1,SafetyofInformation
TechnologyEquipment.Ifitsconnectingcablesareroutedoutdoors,
theproductshallbegroundedeitherthroughashieldednetworkcable
(STP)orotherappropriatemethod.
Thepowersupplyusedwiththisproductshallfullltherequirements
forSafetyExtraLowVoltage(SELV)andLimitedPowerSource(LPS)
accordingtoIEC/EN/UL60950-1.
DisposalandRecycling
Whenthisproducthasreachedtheendofitsusefullife,disposeof
itaccordingtolocallawsandregulations.Forinformationabout
yournearestdesignatedcollectionpoint,contactyourlocalauthority
responsibleforwastedisposal.Inaccordancewithlocallegislation,
penaltiesmaybeapplicableforincorrectdisposalofthiswaste.
Europe
Thissymbolmeansthattheproductshallnotbedisposedof

togetherwithhouseholdorcommercialwaste.Directive2012/19/EU
onwasteelectricalandelectronicequipment(WEEE)isapplicablein
theEuropeanUnionmemberstates.Topreventpotentialharmto
humanhealthandtheenvironment,theproductmustbedisposed
ofinanapprovedandenvironmentallysaferecyclingprocess.For
informationaboutyournearestdesignatedcollectionpoint,contact
yourlocalauthorityresponsibleforwastedisposal.Businessesshould
contacttheproductsupplierforinformationabouthowtodispose
ofthisproductcorrectly.
ThisproductcomplieswiththerequirementsofDirective2011/65/EU
ontherestrictionoftheuseofcertainhazardoussubstancesin
electricalandelectronicequipment(RoHS).
China
Thisproductcomplieswiththerequirementsofthelegislative
actAdministrationontheControlofPollutionCausedbyElectronic
InformationProducts(ACPEIP).
ContactInformation
AxisCommunicationsAB
Emdalavägen14
22369Lund
Sweden
Tel:+46462721800
Fax:+4646136130
www.axis.com
SupportedReaders
Thislistofsupportedreadersissubjecttochangewithoutnotice.
ContactyourAxisresellerforinformationaboutsupportedreaders.
ThisproductiscompatiblewithUL-listedWiegandaccesscontrol
readers
ThisproductisapprovedforuseinsystemsthatrequireULcertication
whenconnectedtothefollowingcompatibleRS485accesscontrol
readers:
HIDiCLASS®RW100:6101CG40000,6101CGM0000,
6101CK40000,6101CK40002,6101CK40100,6101CK403C0,
6101CKM0000,6101CKM0002,6101CKM0203;RW300:
6111CG40000,6111CG400C0,6111CGM0000,6111CK40000,
6111CK4000Z,6111CKM0000;RW400:6121CG40000,
6121CGM0000,6121CK40000,6121CK40003,6121CK40007-G3.0,
6121CK4000D-G3.0,6121CKM0000;RK40:6122CKP00P0,
6122CKP05P0,6122CKP06P0;RWK400:6131CG4020000,
6131CK4000000,6131CK4000014,6131CK4000300,6131CK4020000,
6131CKM000000,6131CKM000214;RK40:6132BKP00Q709-G3.0,
6132CKP000009,6132CKP000011,6132CKP000700-G3.0,
6132CKP000709-G3.0,6132CKP001009,6132CKP001011,
6132CKP00P000,6132CKP00P009,6132CKP00P709-G3.0,
6132CKP00Q709-G3.0,6132CKP030014,6132CKP060514,
6132CKP06P009,6132CKP06P609,6132CKP070209;RW150:
6141CG40000,6141CGM0000,6141CK40000,6141CKM0000;
R15:6142CKP000Z,6142CKP00P0,6142CKP0100;RWKL550:
6171BK4000000,6171BK4000009,6171BK4000014,6171BK4000214,
6171BK4000500,6171BK4040Z14,6171BK4060000,6171BK4060209,
6171BK4060Z09,6171BK4061000,6171BKM000000,
6171BKM000200,6171BKM000300,6171BKM040400;RWKLB575:
6181BK4000000,6181BK4000009,6181BK4000014,6181BK4000022,
6181BK406C009;
HIDSmartid®:8031DSAP
HIDpivClass®R10-H:900LHRNAK00000,900LHRTAK00000,
900NHRNAK00000,900NHRTAK00000,900PHRNAK00000,
900PHRTAK00000,910LHRNAK00000,910LHRTAK00000,
910NHRNAK00000,910NHRTAK00000,910PHRNAK00000,
910PHRTAK00000,920LHRNAK00000,920LHRTAK00000,
920NHRNAK00000,920NHRTAK00000,920PHRNAK00000,
920PHRTAK00000,921LHRNAK00000,921LHRTAK00000,
921NHRNAK00000,921NHRTAK00000,921PHRNAK00000,
921PHRTAK00000;RPKCL40-P:923LPRNAK00000,923LPRTAK00000,
923NPRTAK00000,923PPRNAK00000,923PPRTAK00000
AptiqTM:M11,MTK15,MTMSK15,MT15,MTMS15
Support
Shouldyourequireanytechnicalassistance,pleasecontactyourAxis
reseller.Ifyourquestionscannotbeansweredimmediately,your
resellerwillforwardyourqueriesthroughtheappropriatechannelsto
ensurearapidresponse.IfyouareconnectedtotheInternet,youcan:
•downloaduserdocumentationandsoftwareupdates
•ndanswerstoresolvedproblemsintheFAQdatabase.Search
byproduct,category,orphrase
•reportproblemstoAxissupportstaffbyloggingintoyourprivate
supportarea
•chatwithAxissupportstaff(selectedcountriesonly)
•visitAxisSupportatwww.axis.com/techsup/
LearnMore!
VisitAxislearningcenterwww.axis.com/academy/forusefultrainings,
webinars,tutorialsandguides.

AXISA1001NetworkDoorController&AXISEntryManager
TableofContents
HardwareOverview..........................................5
LEDIndicators..................................................7
ConnectorsandButtons..........................................8
AccessingtheProduct.......................................10
AccessfromaBrowser...........................................10
AccessfromtheInternet..........................................10
SettheRootPassword...........................................10
SystemConguration........................................11
ConguretheHardware..........................................11
ManageNetworkDoorControllers..................................14
MaintenanceInstructions.........................................16
AccessManagement.........................................17
AccessSchedules................................................17
Groups........................................................19
Doors.........................................................20
Users.........................................................22
ExampleAccessScheduleCombinations.............................24
AlarmandEventConguration................................26
CongureEventandAlarmLogs....................................26
Events........................................................27
ReaderFeedback................................................30
SystemOptions.............................................32
Security.......................................................32
Date&Time....................................................34
Network.......................................................34
Ports&Devices.................................................39
Maintenance...................................................39
Support.......................................................40
Advanced......................................................41
ResettoFactoryDefaultSettings...................................41
Troubleshooting............................................42
CheckingtheFirmware...........................................42
UpgradingtheFirmware..........................................42
EmergencyRecoveryProcedure....................................42
Symptoms,PossibleCausesandRemedialActions.....................43
TechnicalSpecications......................................45
AXISA1001NetworkDoorController...............................45
AXISEntryManager.............................................47
Connectors....................................................48
ConnectionDiagrams............................................52
4

AXISA1001NetworkDoorController&AXISEntryManager
HardwareOverview
HardwareOverview
1
2
5
4
8
6
7
3
Frontandback:
1Cover
2Coverscrew
3Coverremovalslot
4Base
5DINclip–upper
6Tamperingalarmswitch–back
7DINclip–lower
8Partnumber(P/N)&Serialnumber(S/N)
5

AXISA1001NetworkDoorController&AXISEntryManager
HardwareOverview
1
2
3
4
5
6
7
8
910
11
12
I/Ointerface:
1Readerdataconnector(READERDATA1)
10Readerdataconnector(READERDATA2)
3ReaderI/Oconnector(READERI/O1)
8ReaderI/Oconnector(READERI/O2)
4Doorconnector(DOORIN1)
7Doorconnector(DOORIN2)
6Auxiliaryconnector(AUX)
5Audioconnector(AUDIO)(notused)
Externalpowerinputs:
2Powerconnector(DCIN)
12Networkconnector(PoE)
Poweroutputs:
9Powerlockconnector(LOCK)
11Power&Relayconnector(PWR,RELAY)
6

AXISA1001NetworkDoorController&AXISEntryManager
HardwareOverview
1
234
5
6
7
8
9
1011
12
13
LEDindicators,buttonsandotherhardware:
1PowerLEDindicator
2StatusLEDindicator
3NetworkLEDindicator
4Reader2LEDindicator(notused)
5Reader1LEDindicator(notused)
6Tamperingalarmpinheader–front(TF)
7Tamperingalarmpinheader–back(TB)
8LockLEDindicator
9LockLEDindicator
10Tamperingalarmsensor–front
11SDcardslot(microSDHC)(notused)
12Controlbutton
13Partnumber(P/N)&Serialnumber(S/N)
LEDIndicators
LEDColorIndication
GreenSteadyforconnectiontoa100MBit/snetwork.Flashesfornetworkactivity.
AmberSteadyforconnectiontoa10MBit/snetwork.Flashesfornetworkactivity.
Network
UnlitNonetworkconnection.
GreenSteadygreenfornormaloperation.
AmberSteadyduringstartupandwhenrestoringsettings.
Status
RedSlowashforfailedupgrade.
GreenNormaloperation. Power
AmberFlashesgreen/amberduringrmwareupgrade.
7

AXISA1001NetworkDoorController&AXISEntryManager
HardwareOverview
GreenSteadywhennotenergized.
RedSteadywhenenergized.
Lock
UnlitFloating.
Note
•TheStatusLEDcanbeconguredtoashwhileaneventisactive.
•TheStatusLEDcanbeconguredtoashforidentifyingtheunit.GotoSetup>AdditionalControllerConguration>
SystemOptions>Maintenance.
ConnectorsandButtons
Fortechnicalspecications,seepage45.
I/OInterface
ReaderDataConnector
Two6-pinterminalblockssupportingRS485andWiegandprotocolsforcommunicationwiththereader.
ReaderI/OConnector
Two6-pinterminalblocksforreaderinputandoutput.Inadditiontothe0VDCreferencepointandpower(DCoutput),the
readerI/Oconnectorprovidestheinterfaceto:
•Digitalinput–Forconnecting,forexample,readertamperingalarms.
•Digitaloutput–Forconnecting,forexample,readerbeepersandreaderLEDs.
DoorConnector
Two4-pinterminalblocksforconnectingdoormonitoringdevicesandrequesttoexit(REX)devices
AuxiliaryConnector
4-pincongurableI/Oterminalblock.Usewithexternaldevices,incombinationwith,forexampletamperingalarms,eventtriggering
andalarmnotications.Inadditiontothe0VDCreferencepointandpower(DCoutput),theauxiliaryconnectorprovidesthe
interfaceto:
•Digitalinput–Analarminputforconnectingdevicesthatcantogglebetweenanopenandclosedcircuit,forexamplePIR
sensorsorglassbreakdetectors.
•Digitaloutput–Forconnectingexternaldevicessuchasburglaralarms,sirensorlights.Connecteddevicescanbe
activatedbytheVAPIX®applicationprogramminginterfaceorbyanactionrule.
ExternalPowerInputs
NOTICE NOTICE
NOTICE
Theproductshallbeconnectedusingashieldednetworkcable(STP).Allcablesconnectingtheproducttothenetworkshall
beintendedfortheirspecicuse.Makesurethatthenetworkdevicesareinstalledinaccordancewiththemanufacturer’s
instructions.Forinformationaboutregulatoryrequirements,seeElectromagneticCompatibility(EMC),onpage2.
PowerConnector
2-pinterminalblockforDCpowerinput.UseaSafetyExtraLowVoltage(SELV)compliantlimitedpowersource(LPS)witheither
aratedoutputpowerlimitedto≤100Woraratedoutputcurrentlimitedto≤5A.
NetworkConnector
RJ45Ethernetconnector.SupportsPoweroverEthernet(PoE).
PowerOutputs
PowerLockConnector
4-pinterminalblockforconnectingoneortwolocks.Thelockconnectorcanalsobeusedtopowerexternaldevices.
8

AXISA1001NetworkDoorController&AXISEntryManager
HardwareOverview
Power&RelayConnector
6-pinterminalblockforconnectingpowerandthedoorcontroller’srelaytoexternaldevicessuchaslocksandsensors.
ButtonsandOtherHardware
TamperingAlarmPinHeader
Two2-pinheadersfordisconnectingthefrontandbacktamperingalarms.
ControlButton
Thecontrolbuttonisusedfor:
•Resettingtheproducttofactorydefaultsettings.Seepage41.
•ConnectingtoanAXISVideoHostingSystemservice.Seepage35.Toconnect,pressandholdthebuttonforabout1
seconduntiltheStatusLEDashesgreen.
•ConnectingtoAXISInternetDynamicDNSService.Seepage36.Toconnect,pressandholdthebuttonforabout3seconds.
9

AXISA1001NetworkDoorController&AXISEntryManager
AccessingtheProduct
AccessingtheProduct
ToinstalltheAxisproduct,refertotheInstallationGuidesuppliedwiththeproduct.
Theproductcanbeusedwithmostoperatingsystemsandbrowsers.TherecommendedbrowsersareInternetExplorerwithWindows,
SafariwithMacintoshandFirefoxwithotheroperatingsystems.SeeTechnicalSpecications,onpage45
AccessfromaBrowser
1.Startabrowser(InternetExplorer,Firefox,Safari).
2.EntertheIPaddressorhostnameoftheAxisproductinthebrowser’sLocation/Addresseld.Toaccesstheproductfroma
Macintoshcomputer(MacOSX),clickontheBonjourtabandselecttheproductfromthedrop-downlist.
IfyoudonotknowtheIPaddress,useAXISIPUtilitytolocatetheproductonthenetwork.Forinformationabouthowto
discoverandassignanIPaddress,seetheInstallationGuide,availableonaxis.com.Thisinformationisalsoavailablefrom
thesupportpagesonwww.axis.com/techsup
3.Enteryourusernameandpassword.Ifthisisthersttimetheproductisaccessed,therootpasswordmustrstbe
congured.Forinstructions,seeSettheRootPassword,onpage10.
4.AXISEntryManageropensinyourbrowser.ThestartpageiscalledtheOverviewpage.
AccessfromtheInternet
Onceconnected,theAxisproductisaccessibleonyourlocalnetwork(LAN).ToaccesstheproductfromtheInternetyoumust
congureyournetworkroutertoallowincomingdatatrafctotheproduct.Todothis,enabletheNAT-traversalfeature,whichwill
attempttoautomaticallyconguretheroutertoallowaccesstotheproduct.ThisisenabledfromSetup>AdditionalController
Conguration>SystemOptions>Network>TCP/IP>Advanced.
Formoreinformation,seeNATtraversal(portmapping)forIPv4,onpage37.SeealsoAXISInternetDynamicDNSService
atwww.axiscam.net
ForTechnicalnotesonthisandothertopics,visittheAxisSupportwebatwww.axis.com/techsup
SettheRootPassword
ToaccesstheAxisproduct,youmustsetthepasswordforthedefaultadministratoruserroot.ThisisdoneintheCongureRoot
Passworddialog,whichopenswhentheproductisaccessedforthersttime.
Topreventnetworkeavesdropping,therootpasswordcanbesetviaanencryptedHTTPSconnection,whichrequiresanHTTPS
certicate.HTTPS(HypertextTransferProtocoloverSSL)isaprotocolusedtoencrypttrafcbetweenwebbrowsersandservers.The
HTTPScerticateensuresencryptedexchangeofinformation.SeeHTTPS,onpage32.
Thedefaultadministratorusernamerootispermanentandcannotbedeleted.Ifthepasswordforrootislost,theproductmustbe
resettothefactorydefaultsettings.SeeResettoFactoryDefaultSettings,onpage41.
TosetthepasswordviaastandardHTTPconnection,enteritdirectlyinthedialog.
TosetthepasswordviaanencryptedHTTPSconnection,followthesesteps:
1.ClickUseHTTPS.
Atemporarycerticate(validforoneyear)iscreated,enablingencryptionofalltrafctoandfromtheproduct,andthe
passwordcannowbesetsecurely.
2.Enterapasswordandthenre-enterittoconrmthespelling.
3.ClickOK.Thepasswordhasnowbeencongured.
10

AXISA1001NetworkDoorController&AXISEntryManager
SystemConguration
SystemConguration
TheOverviewpageshowsinformationaboutthedoorcontroller’sname,MACaddress,IPaddress,andrmwareversion.Italso
enablesyoutoidentifythedoorcontrolleronthenetworkorinthesystem.
ThersttimeyouaccesstheAxisproduct,theOverviewpagewillpromptyoutocongurethehardware,tosetdateandtime,to
congurethenetworksettings,andtocongurethedoorcontrolleraspartofasystemorasastandaloneunit.
Tocongurethedoorcontroller:
1.Congurethedoorcontrollerandconnecteddevicessuchasreaders,locksandrequesttoexit(REX)devices.SeeCongure
theHardware,onpage11.
2.Setthedateandtime.SeeDate&Time,onpage34.
3.Congurethenetworksettings.SeeNetwork,onpage34.
4.Congurethedoorcontrollersystem.SeeManageNetworkDoorControllers,onpage14.
Forinformationabouthowtocongureandmanagethesystem'sdoors,schedules,usersandgroups,seeAccessManagement,on
page17.
ToreturntotheOverviewpagefromtheproduct’sotherwebpages,clickOverviewinthemenubar.
Note
Toaddorremovedoorcontrollers,toadd,remove,oreditusers,ortocongurethehardware,morethanhalfofthedoor
controllersinthesystemmustbeonline.Tocheckthedoorcontrollerstatus,gotoSetup>ManageNetworkDoor
ControllersinSystem.
ConguretheHardware
Beforeyoucanmanagethedoors,thehardwaremustbeconguredintheHardwareCongurationpages.
Doors,locksandotherdevicescanbeconnectedtotheAxisproductbeforecompletingthehardwareconguration.However,the
connectionofdeviceswillbeeasierifyoucompletethehardwarecongurationrst.Thisisbecausethehardwarepinchartwillbe
availablewhenthecongurationiscomplete.Thehardwarepinchartisaguideonhowtoconnectthepinsandcanbeusedas
areferencesheetformaintenance.
Tocongurethehardware:
1.GotoSetup>HardwareCongurationandclickStartnewhardwareconguration.Iftheproduct’shardwarehasnot
beencongured,HardwareCongurationwillbeavailableinthenoticationpanelintheOverviewpage.
2.Selectadooroptiondependingonthenumberofdoors,one(1)ortwo(2),thatwillbeconnectedtotheAxisproduct
3.EnteradescriptivenameforeachdoorandclickNext.Itisrecommendedtoprovidethedoorswithuniquedescriptive
namessothattheyeasilycanbeidentifedbyanyonewhowilladministratethesystem.
4.SelectthelockoptionsthatmatchtherequirementsandthetypeoflockconnectionsthatwillbeusedandclickNext.For
moreinformationaboutavailableoptions,seeLocks,onpage12.
5.SelectthetypesofreadersthatwillbeusedandclickFinish.Formoreinformationaboutavailableoptions,seeReaders,
onpage13.
Tocancelthehardwareconguration,clickCancel.Thiscanbedoneinanyofthehardwarecongurationpages.
Toviewthehardwarepinchart,gotoSetup>HardwarePinChart.
Toprintthehardwarepinchart,clickPrintHardwarePinChart.
Todeletethehardwareconguration,clickResethardwarecongurationforthiscontroller.
11

AXISA1001NetworkDoorController&AXISEntryManager
SystemConguration
Todeleteandrecongurethehardwareconguration,clickResetandstartnewhardwareconguration.
Locks
1.Ifadoormonitorwillbeused,selectDoormonitorandthenselecttheoptionthatmatcheshowthedoormonitor
circuitswillbeconnected.
2.Ifthedoorlockshalllockimmediatelyafterthedoorhasbeenopened,selectLockwhendooropens.
3.Specifythedoormonitortimeoptions,orifnodoormonitorwillbeused,thelocktimeoptions.
Thefollowingoptionsfordoormonitors,doormonitortimeandlocktimeareavailable:
•Doormonitor
-Opencircuit=Opendoor–Thedoormonitorgivesthedooropensignalwhenthecircuitisopen.Selectifthe
doormonitorcircuitisnormallyclosed.
-Opencircuit=Closeddoor–Thedoormonitorgivesthedoorclosedsignalwhenthecircuitisopen.Selectif
thedoormonitorcircuitisnormallyopen.
•Lockwhendooropens–Selectifthedoorshalllockimmediatelyafterthedoorhasbeenopened.Whenthedoor
closes,thedoorlockswithoutdelay.
•Accesstime–Setthenumberofsecondsthedoorshallremainunlockedafteraccesshasbeengranted.Thedoorremains
unlockeduntilthedoorhasbeenopenedandwilllockwhenitclosesregardlessofwhethertheaccesstimehasexpiredor
not.Ifthedoorremainsunopened,itlockswhenthesetaccesstimehasbeenreached.
•Opentoolongtime–Setthenumberofsecondsthedoorisallowedtostayopen.Ifthedoorisstillopenwhenthe
opentoolongtimehasbeenreached,thedooropentoolongalarmistriggered.Setupanactionruletocongurewhich
actiontheopentoolongeventshalltrigger.
•Pre-alarmtime–Apre-alarmisawarningsignalthatistriggeredbeforetheopentoolongtimehasbeenreached.It
tellstheadministratorand,dependingonhowtheactionrulehasbeensetup,itcanalsowarntheuser(theperson
enteringthedoor)thatthedoorneedstobeclosedortherealalarm,thedooropentoolongalarm,willgooff.Setthe
numberofsecondsbeforethedooropentoolongalarmistriggeredthesystemshallgivethepre-alarmwarningsignal.
Todisablethepre-alarm,setthepre-alarmtimeto0.
•Doorunlockedtime–DeselectDoormonitortomakethisoptionavailable.Setthenumberofsecondsthedoorshall
remainunlockedafteraccesshasbeengranted.Thedoorremainsunlockeduntilthedoorhasbeenopenedandwill
lockwhenitclosesregardlessofwhetherthedoorunlockedtimehasexpiredornot.Ifthedoorremainsunopened,it
lockswhenthesetdoorunlocktimehasbeenreached.
•Pre-locksignaltime–DeselectDoormonitortomakethisoptionavailable.Apre-locksignalisawarningsignalthatis
triggeredbeforethedoorlocks.Ittellstheadministratorand,dependingonhowtheactionrulehasbeensetup,itcanalso
warntheuser(thepersonenteringthedoor)thatthedoorwilllocksoon.Setthenumberofsecondsbeforethedoor
locksthesystemshallgivethepre-lockwarningsignal.Thepre-locksignaltimemustbeshorterthanthedoorunlocked
time.Todisablethepre-lockwarningsignal,setthepre-locksignaltimeto0.
Forinformationabouthowtosetupanactionrule,seeSettingUpanActionRule,onpage29.
Thefollowingoptionsforlocksareavailable:
•12V
-Locked=GND(-)–Selectforlocksthatremainlockedduringpoweroutages(failclose/secure).
-Locked=12V–Selectforlocksthatunlockduringpoweroutages(failopen/safe).
•Relay–Canonlybeusedononelockperdoorcontroller.Iftwodoorsareconnectedtothedoorcontroller,arelaycan
onlybeusedonthelockoftheseconddoor.
-Locked=Relayopen–Selectforlocksthatremainlockedwhentherelayisopen(failclose/secure).
12

AXISA1001NetworkDoorController&AXISEntryManager
SystemConguration
-Locked=Relayclosed–Selectforlocksthatunlockduringpoweroutages(failopen/safe).
•None–Selectifonlyonelockwillbeused.
Note
•Mostlock,doormonitor,andreaderoptionscanbechangedwithoutresettingandstartinganewhardwareconguration.
GotoSetup>HardwareReconguration.
•Motorizedlocksmustbeconguredassecondarylocks.
Readers
1.Ifareaderwillbeused,selectReaderandthenselecttheoptionsthatmatchthereader’scommunicationprotocol.
2.Ifarequesttoexit(REX)devicesuchasabutton,sensor,orpushbarwillbeused,selectREXandthenselecttheoption
thatmatcheshowtheREXdevice’scircuitswillbeconnected.
Ifthedoorshallremainlockeduntiltheusermanuallyunlocksandopensthedoor,selectRequiremanualunlock.
3.IfconnectingmorethanonereaderorREXdevicetothedoorcontroller,dotheprevioustwostepsagainuntileach
readerorREXdevicehasthecorrectsettings.
Thefollowingoptionsforreadersareavailable:
•Wiegand–SelectforreadersthatuseWiegandprotocols.
•RS485halfduplex–SelectforRS485readerswithhalfduplexsupportandthenselecttheRS485protocolthatis
supportedbythereader.Seethemanufacturer’sinformationaboutwhichprotocolthereadersupports.
•RS485fullduplex–SelectforRS485readerswithfullduplexsupportandthenselecttheRS485protocolthatissupported
bythereader.Seethemanufacturer’sinformationaboutwhichprotocolthereadersupports.
ThefollowingoptionsforREXdevicesareavailable:
•Activelow–SelectifactivatingtheREXdeviceclosesthecircuit.
•Activehigh–SelectifactivatingtheREXdeviceopensthecircuit.
•Requiremanualunlock–Selectifthedoorshallremainlockeduntiltheusermanuallyunlocksandopensthedoor.The
doorforcedopenalarmwillnotbetriggeredaslongastheuseropensthedoorwithintheaccesstime.Deselectifthedoor
shallunlockautomaticallywhentheuseractivatestheREXdevice.
Important
Ifthedoorcontrollerhasonlybeenconguredwithonedoorbeforeitisupgradedtormware1.15orlaterfromrmware
1.10,Requiremanualunlockwillbenon-selectableatrst.TomakeRequiremanualunlockselectable,gotoSetup>
HardwareCongurationandclickResetandstartanewhardwareconguration.Thensetuptherulesforthedoors
connectedtothedoorcontrollerandaddthemtogroups,seeDoors.
Note
Mostlock,doormonitor,andreaderoptionscanbechangedwithoutresettingandstartinganewhardwareconguration.
GotoSetup>HardwareReconguration.
VerifytheHardwareConnections
Whenthehardwareinstallationandcongurationiscomplete,andanytimeduringthedoorcontroller’slifetime,youcanverifythe
functionoftheconnecteddoormonitors,locksandreaders.
Toverifythecongurationandaccessthevericationcontrols,gotoSetup>HardwareConnectionVerication.
VericationControls
•Doorstate–Verifythecurrentstateofthedoormonitor,dooralarmsandlocks.ClickGetcurrentstate.
13

AXISA1001NetworkDoorController&AXISEntryManager
SystemConguration
•Lock–Manuallytriggerthelock.Bothprimarylocksandsecondarylocksifthereareanywillbeaffected.ClickLockor
Unlock.
•Lock(access)–Manuallytriggerthelocktograntaccess.Onlyprimarylockswillbeaffected.ClickAccess.
•Reader:Feedback–Verifythereaderfeedback,forexamplesoundsandLEDsignals,fordifferentcommands.Selectthe
commandandclickTest.Whichtypesoffeedbackthatareavailabledependsonthereader.Formoreinformation,see
ReaderFeedback.Seealsothemanufacturer’sinstructions.
•Reader:Tampering–Getinformationaboutthelasttamperingattempt.Thersttamperingattemptwillberegistered
whenthereaderisinstalled.ClickGetlasttampering.
•Reader:Cardswipe–Getinformationaboutthelastswipedcardorothertypeofusertokenacceptedbythereader.
ClickGetlastcredential.
•REX–Getinformationaboutthelasttimetherequesttoexit(REX)devicewaspressed.ClickGetlastREX.
ManageNetworkDoorControllers
TheManageNetworkDoorControllersinSystempageshowsinformationaboutthedoorcontroller,itssystemstatusandwhich
otherdoorcontrollersarepartofthesystem.Italsoenablestheadministratortochangethesystemsetupbyaddingandremoving
doorcontrollers.
Tomanagedoorcontrollers,gotoSetup>ManageNetworkDoorControllersinSystem.
Systemstatusforthiscontroller-Showsthedoorcontroller'ssystemstatusandenablesswitchingbetweensystemandstandalone
modes.Formoreinformation,seeSystemStatus,onpage14.
Networkdoorcontrollersinsystem-Showsalistwhichcontainsthefollowinginformationaboutthedoorcontrollersinthesystem:
•Name–Theuser-denednameofthedoorcontroller.Iftheadministratorhasnotsetanamewhenconguring
thehardware,thedefaultnamewillbeshown.
•IPaddress
•MACaddress
•Status–ThedoorcontrollerfromwhichyouaccessthesystemwillshowstatusThiscontroller.Theotherdoor
controllersinthesystemwillshowstatusOnline.
Forinformationabouthowto
•changethedoorcontrollersystemstatus,seeSystemStatus,onpage14.
•addadoorcontrollertoasystem,seeAddDoorControllerstotheSystem,onpage15.
•removeadoorcontrollerfromasystem,seeRemoveDoorControllersfromtheSystem,onpage15.
SystemStatus
Ifthedoorcontrollercanbepartofasystemofdoorcontrollersdependsonitssystemstatus.Thedoorcontroller’ssystemstatus
isdisplayedunderSystemstatusforthiscontroller.Availablesystemstatusesare:
Thiscontrollerisnotpartofasystemandnotinstandalonemode-Thedoorcontrollerhasnotbeenconguredaspartofa
systemanditisnotinstandalonemode.Thismeansthatthedoorcontrollerisopenandcanbeaddedtoasystembyanyotherdoor
controllerwithinthesamenetwork.Toprotectthedoorcontrollerfrombeingaddedtoasystem,activatethestandalonemode.To
setthedoorcontrollertostandalonemode,clickActivatestandalonemode.
Thiscontrollerissettostandalonemode-Thedoorcontrollerisnotpartofasystem.Itcannotbeaddedtoasystembyotherdoor
controllersinthenetworkoraddotherdoorcontrollersitself.Standalonemodeistypicallyusedinasmallsetupwithoneortwo
doors.Ifyouareplanningonaddingthedoorcontrollertoasystem,clickDeactivatestandalonemode.
Thiscontrollerispartofasystem-Thedoorcontrollerispartofadistributedsystemsharingusers,groups,doorsandschedules.
14

AXISA1001NetworkDoorController&AXISEntryManager
SystemConguration
AddDoorControllerstotheSystem
Important
Whenpairingdoorcontrollers,allaccessmanagementsettingsontheaddeddoorcontrollerwillbedeletedandoverwritten
bythesystem’saccessmanagementsettings.
Toaddadoorcontrollertothesystemfromthelistofdoorcontrollers:
1.GotoSetup>ManageNetworkDoorControllersinSystem.
2.ClickAddcontrollerstosystemfromlist.
3.Selectthedoorcontrollerthatyouwishtoadd.
4.ClickAdd.
5.Toaddmoredoorcontrollers,repeatthestepsabove.
ToaddadoorcontrollertothesystembyitsknownIPaddressorMACaddress:
1.GotoManageDevices.
2.ClickAddcontrollertosystembyIPorMACaddress.
3.EntertheIPaddressorMACaddress.
4.ClickAdd.
5.Toaddmoredoorcontrollers,repeatthestepsabove.
Whenthepairingiscompleted,allusers,doors,schedules,andgroupsaresharedbyalldoorcontrollersinthesystem.
Toupdatethelist,clickRefreshlistofcontrollers.
RemoveDoorControllersfromtheSystem
Important
•Beforeremovingadoorcontrollerfromthesystem,resetitshardwareconguration.Ifyouskipthisstep,alldoorsrelatedto
theremoveddoorcontrollerwillremaininthesystemandcannotbedeleted.
•Whenremovingadoorcontrollerfromatwo-controllersystem,bothdoorcontrollersautomaticallyswitchtostandalone
mode.
Toremoveadoorcontrollerfromthesystem:
1.AccessthesystemthroughthedoorcontrollerthatyouwanttoremoveandgotoSetup>HardwareConguration.
2.ClickResethardwareconguration.
3.Afterthehardwarecongurationhasbeenreset,gotoSetup>ManageNetworkDoorControllersinSystem.
4.IntheNetworkdoorcontrollersinsystemlist,identifythedoorcontrollerthatyouwanttoremoveandclickRemove
fromsystem.
5.Adialogopensremindingyoutoresetthedoorcontroller’shardwareconguration.ClickRemovecontrollertoconrm.
6.Adialogopenspromptingyoutoconrmthatyouwanttoremovethedoorcontroller.ClickOKtoconrm.Theremoved
doorcontrollerisnowinstandalonemode.
Note
•Whenadoorcontrollerisremovedfromthesystem,allitsaccessmanagementsettingsaredeleted.
•Onlydoorcontrollersthatareonlinecanberemoved.
15

AXISA1001NetworkDoorController&AXISEntryManager
SystemConguration
MaintenanceInstructions
Tokeeptheaccesscontrolsystemrunningsmoothly,Axisrecommendsregularmaintenanceoftheaccesscontrolsystem,including
doorcontrollersandconnecteddevices.
Domaintenanceatleastonceayear.Thesuggestedmaintenanceprocedureincludes,butisnotlimitedto,thefollowingsteps:
•Makesurealltheconnectionsbetweenthedoorcontrollerandtheexternaldevicesaresecure.
•Verifyallthehardwareconnections.SeeVericationControls,onpage13.
•Verifythatthesystem,includingtheconnectedexternaldevices,functionscorrectly.
-Swipeacardandtestthereaders,doors,andlocks.
-IfthesystemincludesREXdevices,sensorsorotherdevices,testthemaswell.
-Ifactivated,testthetamperingalarms.
Iftheresultsfromanyofthestepsaboveindicatefaultsorunexpectedbehavior:
-Testthesignalsofthewiresusingappropriateequipmentandcheckifthewiresorcablesaredamaged
inanyway.
-Replacealldamagedorfaultycablesandwires.
-Oncethecablesandwireshavebeenreplaced,verifyallthehardwareconnectionsagain.SeeVerication
Controls,onpage13.
•Makesureallaccessschedules,doors,groups,andusersareuptodate.
•Ifthedoorcontrollerisnotbehavingasexpected,seeTroubleshooting,onpage42andMaintenance,onpage39for
moreinformation.
16

AXISA1001NetworkDoorController&AXISEntryManager
AccessManagement
AccessManagement
TheAccessManagementpageallowsyoutocongureandmanagethesystem’susers,groups,doors,andschedules.Toopenthe
AccessManagementpage,clickAccessManagement.
Theaccessmanagementstructureisexible,allowingyoutodevelopaworkowthatsuitsyourneeds.Thefollowingisaworkow
example:
Jane Doe
10010
1
2
34
5
6
7
8
1.Createaccessschedules.Seepage17.
2.Creategroups.Seepage19.
3.Applyaccessschedulestogroups.
4.Addidenticationtypestodoors.Seepage20andpage21.
5.Applyaccessschedulestoeachidenticationtype.
6.Applydoorstogroups.
7.Createusers.Seepage22.
8.Adduserstogroups.
Forappliedexamplesofthisworkow,seeExampleAccessScheduleCombinations,onpage24.
Toadduserstogroupsandapplyaccessschedulesanddoors,dragtheitemstotheirrespectivedestinationintheGroupsand
Doorslists.
Note
Messagesthatrequireactionareshowninredtext.
AccessSchedules
Accessschedulesareusedtodenegeneralrulesforwhendoorscanandcannotbeaccessed.Theyarealsousedtodenerulesfor
whengroupscanandcannotaccessthedoorsinthesystem.Formoreinformation,seeAccessScheduleTypes,onpage18.
Tocreateanewaccessschedule:
1.IntheAccessSchedulestab,clickAddnewschedule.
2.IntheAddaccessscheduledialog,entertheschedulename.
17

AXISA1001NetworkDoorController&AXISEntryManager
AccessManagement
3.Tocreatearegularaccessschedule,selectAdditionSchedule,ortocreateasubtractionschedule,selectSubtraction
Schedule.
4.ClickSave.
ToexpandanitemintheAccessScheduleslist,click.Additionschedulesareshowningreentextandsubtractionschedules
areshownindarkredtext.
Toviewanaccessschedule’scalendar,click.
Toeditanaccessschedule’snameorascheduleitem,clickandmakethechanges.ThenclickSave.
Todeleteanaccessschedule,click.
Note
Thedoorcontrollerhasafewpredenedcommonlyusedaccessschedulesthatcanbeusedasexamplesormodiedas
required.However,thepredenedaccessscheduleAlwayscannotbemodiedordeleted.
AccessScheduleTypes
Therearetwotypesofaccessschedules:
Additionschedule-Regularaccessschedulesthatdenewhendoorscanbeaccessed.Typicaladditionschedulesareofcehours,
businesshours,afterhours,ornighttimehours.
Subtractionschedule-Exceptionstoregularaccessschedules.Theyaregenerallyusedtorestrictaccessduringaspecictime
periodthatoccurswithinthetimeperiodofaregularschedule(additionschedule).Forexample,subtractionschedulescanbeused
todenyusersaccesstothebuildingduringpublicholidaysthatoccuronweekdays.
Bothtypesofaccessschedulescanbeusedattwolevels:
Identicationtypeschedules-Determinewhenandhowreadersgrantusersaccesstoadoor.Eachidenticationtypemustbe
connectedtoanaccessschedulethattellsthesystemwhentograntusersaccesswiththatparticularidenticationtype.Multiple
additionschedulesandsubtractionschedulescanbeaddedtoeachidenticationtype.Forinformationaboutidenticationtypes,
seepage21.
Groupschedules-Determinewhen,butnothow,membersofagrouparegrantedaccesstoadoor.Eachgroupmustbeconnected
tooneormoreaccessschedulesthattellthesystemwhentograntitsmembersaccess.Multipleadditionschedulesandsubtraction
schedulescanbeaddedtoeachgroup.Forinformationaboutgroups,seepage19.
Groupschedulescanrestrictentryaccessrightsbutnotextendentryorexitaccessrightsbeyondwhattheidenticationtype
schedulesallow.Inotherwords,ifanidenticationtypeschedulerestrictsentryorexitaccessatcertaintimes,agroupschedule
cannotoverridethatidenticationtypeschedule.However,ifagroupscheduleismorerestrictiveaboutaccessthantheidentication
typeschedule,thegroupscheduleoverridestheidenticationtypeschedule.
Identicationtypeschedulesandgroupschedulescanbecombinedinseveralwaystoachievedifferentresults.Forexampleaccess
schedulecombinations,seepage24.
ScheduleItems
Bothadditionschedulesandsubtractionschedulescanbeone-time(single)eventsorrecurringevents.
Toaddascheduleitemtoanaccessschedule:
1.ExpandtheaccessscheduleintheAccessScheduleslist.
2.ClickAddscheduleitem.
3.Enterthenameofthescheduleditem.
4.SelectOnetimeorRecurrence.
18

AXISA1001NetworkDoorController&AXISEntryManager
AccessManagement
5.Setthedurationinthetimeelds.SeeTime.
6.Forrecurringscheduleevents,selecttheRecurrencepatternandRangeofrecurrenceparameters.SeeRecurrence
PatternandRangeofRecurrence.
7.ClickSave.
Time
Theavailabletimeoptionsare:
•Allday–Selectforeventsthatlastforall24hoursoftheday.ThenenterthedesiredStartdate.
•Start–Clickthetimeeldandselectthedesiredtime.TheallowedtimeformatisHH:MM.Ifrequired,clickthedateeld
andselectthedesiredmonth,day,andyear.Youcanalsotypethedatedirectlyintheeld(MM/DD/YYYY).
•End–Clickthetimeeldandselectthedesiredtime.TheallowedtimeformatisHH:MM.Ifrequired,clickthedateeld
andselectthedesiredmonth,day,andyear.Youcanalsotypethedatedirectlyintheeld(MM/DD/YYYY).
RecurrencePattern
Theavailablerecurrencepatternsare:
•Yearly–Selecttorepeateveryyear.
•Weekly–Selecttorepeateveryweek.
•RecurseveryweekonMonday,Tuesday,Wednesday,Thursday,Friday,Saturday,andSunday–Selectwhichdaystorepeat.
RangeofRecurrence
Theavailablerangesofrecurrenceare:
•Firstoccurrence–Clickthedateeldandselectthedesiredmonth,day,andyear.Youcanalsotypethedatedirectlyin
theeld(MM/DD/YYYY).
•Noenddate–Selecttorepeattheoccurrenceindenitely.
•Endby–Clickthedateeldandselectthedesiredmonth,day,andyear.Youcanalsotypethedatedirectlyinthe
eld(MM/DD/YYYY).
Groups
Groupsallowyoutomanageusersandtheiraccessrightscollectivelyandefciently.Agroupconsistsofcredentialsthattellthe
systemwhichusersthegroupconsistsofandwhenandhowthegroupmembersaregrantedaccesstothedoors.
Eachusermustbelongtooneormoregroups.Toaddausertoagroup,draganddroptheusertothedesiredgroupintheGroups
list.Formoreinformationaboutusers,seepage22.
Tocreateanewgroup:
1.IntheGroupstab,clickAddnewgroup.
2.IntheAddGroupdialog,enterthegroup’scredentials.
3.ClickSave.
ToexpandanitemintheGroupslistandviewitsmembers,dooraccessrightsandschedules,click.
Toeditagroup’snameorvaliditydate,clickandmakethechanges.ThenclickSave.
19

AXISA1001NetworkDoorController&AXISEntryManager
AccessManagement
Toverifywhenandhowagroupcanaccesscertaindoors,click.
Todeleteagrouporgroupmembers,doorsorschedulesfromagroup,click.
Thefollowingcredentialsareavailable:
•Name(required)
•ValidfromandValidto–Enterthedatesbetweenwhichthegroup’scredentialsshallbevalid.Clickthedateeldand
selectthedesiredmonth,day,andyear.Youcanalsotypethedatedirectlyintheeld(MM/DD/YYYY).
Note
Tobeabletosavetheprole,youmustenterthegroup’sName.
Doors
ThegeneralrulesforeachdooraremanagedintheDoorstab.Therulesincludeaddingidenticationtypesthatdeterminehowusers
willbegrantedaccesstothedoorandaccessschedulesthatdeterminewheneachidenticationtypeisvalid.Formoreinformation,
seeIdenticationTypes,onpage21andAccessSchedules,onpage17.
Beforeyoucanmanageadoor,youmustaddittotheaccesscontrolsystembycompletingthehardwareconguration,see
ConguretheHardware,onpage11.
Tomanageadoor:
1.GotoAccessManagementandselecttheDoorstab.
2.IntheDoorslist,clicknexttothedooryouwanttoedit.
3.Dragthedoortoatleastonegroup.IftheGroupslistisempty,createanewgroup.Seepage19.
4.ClickAddidenticationtypeandselectwhichcredentialsusersneedtopresenttothereadertobegrantedaccess
tothedoor.
Addatleastoneidenticationtypetoeachdoor.
5.Toaddmultipleidenticationtypes,repeatthepreviousstep.
IfbothidenticationtypesCardnumberonlyandPINonlyareadded,userscanchoosetoeitherswipetheircardorenter
theirpintoaccessthedoor.Butif,instead,onlytheidenticationtypeCardnumberandPINisadded,usersmustboth
swipetheircardandentertheirPINtoaccessthedoor.
6.Todenewhenthecredentialsarevalid,dragascheduletoeachidenticationtype.
Tomanuallyunlockdoors,lockdoors,orgranttemporaryaccess,clickoneofthemanualdooractionsasrequired.SeeManualDoor
Actions,onpage21.
ToexpandanitemintheDoorslist,click.
Toeditadoororreadername,clickandmakethechanges.ThenclickSave.
Toverifythereader,identicationtype,andaccessschedulecombinations,click.
Toverifythefunctionofthelocksconnectedtothedoors,clickthevericationcontrols.SeeVericationControls,onpage13.
Todeleteidenticationtypesoraccessschedules,click.
20
Other manuals for A1001
8
This manual suits for next models
1
Table of contents
Other Axis Control Unit manuals
Popular Control Unit manuals by other brands

schmersal
schmersal SRB 401LC operating instructions

Philips
Philips LCN7700 installation instructions

Thermo Scientific
Thermo Scientific Orion VERSA STAR VSTAR-RD reference guide

LSI LASTEM
LSI LASTEM ALIEM EL03305 user manual

LOVATO ELECTRIC
LOVATO ELECTRIC EXP10 16 instruction manual

Sollae Systems
Sollae Systems CSE-M73G user manual