Axis T99A12 User manual

AXIST99A12PositioningUnit24VAC/DC
Installationguide

AXIST99A12PositioningUnit24VAC/DC
Readthisrst..................................................3
Legalconsiderations..............................................3
Liability.......................................................3
Intellectualpropertyrights.........................................3
Equipmentmodications..........................................3
Trademarkacknowledgements.......................................3
Regulatoryinformation...........................................3
Contactinformation..............................................
Warrantyinformation.............................................
Support.......................................................
Learnmore!....................................................
Safetyinformation...............................................5
Safetyinstructions...............................................5
Packagecontents............................................7
Productoverview............................................8
Howtoinstalltheproduct.....................................10
Mountthebaseunit..............................................10
Routethecables................................................12
Installthenetworklink............................................17
Installthecamera...............................................18
Connectthecables...............................................21
SelectthePTZdriver.............................................22
Specications..............................................2
Connectors....................................................2
Cables........................................................27
2

Readthisrst
Readthroughthisinstallationguidecarefullybefore
youinstalltheproduct.Keeptheinstallationguide
forfuturereference.
Legalconsiderations
Videoandaudiosurveillancecanberegulatedbylaws
thatvaryfromcountrytocountry.Checkthelaws
inyourlocalregionbeforeusingthisproductfor
surveillancepurposes.
Liaility
Everycarehasbeentakeninthepreparationofthis
document.PleaseinformyourlocalAxisofceof
anyinaccuraciesoromissions.AxisCommunications
ABcannotbeheldresponsibleforanytechnicalor
typographicalerrorsandreservestherighttomake
changestotheproductandmanualswithoutprior
notice.AxisCommunicationsABmakesnowarranty
ofanykindwithregardtothematerialcontained
withinthisdocument,including,butnotlimitedto,
theimpliedwarrantiesofmerchantabilityandtness
foraparticularpurpose.AxisCommunicationsAB
shallnotbeliablenorresponsibleforincidental
orconsequentialdamagesinconnectionwiththe
furnishing,performanceoruseofthismaterial.This
productisonlytobeusedforitsintendedpurpose.
Intellectualpropertyrights
AxisABhasintellectualpropertyrightsrelatingto
technologyembodiedintheproductdescribedinthis
document.Inparticular,andwithoutlimitation,these
intellectualpropertyrightsmayincludeoneormoreof
thepatentslistedataxis.com/patentandoneormore
additionalpatentsorpendingpatentapplicationsin
theUSandothercountries.
Equipmentmodications
Thisequipmentmustbeinstalledandusedin
strictaccordancewiththeinstructionsgivenin
theuserdocumentation.Thisequipmentcontains
nouser-serviceablecomponents.Unauthorized
equipmentchangesormodicationswillinvalidateall
applicableregulatorycerticationsandapprovals.
Trademarkacknowledgements
AXISCOMMUNICATIONS,AXIS,ARTPECandVAPIX
areregisteredtrademarksofAxisABinvarious
jurisdictions.Allothertrademarksaretheproperty
oftheirrespectiveowners.
Regulatoryinformation
Europe
ThisproductcomplieswiththeapplicableCEmarking
directivesandharmonizedstandards:
•ElectromagneticCompatibility(EMC)Directive
201/30/EU.SeeElectromagneticcompatibility
(EMC)onpage3.
•LowVoltageDirective(LVD)201/35/EU.See
Safetyonpage4.
•RestrictionofHazardousSubstances(RoHS)
Directive2011/65/EUand2015/863,includingany
amendments,updatesorreplacements.See.
Acopyoftheoriginaldeclarationofconformity
maybeobtainedfromAxisCommunicationsAB.See
Contactinformationonpage4.
Electromagneticcompatiility(EMC)
Thisequipmenthasbeendesignedandtestedtofulll
applicablestandardsfor:
•Radiofrequencyemissionwheninstalled
accordingtotheinstructionsandusedinits
intendedenvironment.
•Immunitytoelectricalandelectromagnetic
phenomenawheninstalledaccordingtothe
instructionsandusedinitsintendedenvironment.
USA
Thisdevicecomplieswithpart15oftheFCCRules.
Operationissubjecttothefollowingtwoconditions:
1.Thisdevicemaynotcauseharmfulinterference,
and
2.thisdevicemustacceptanyinterferencereceived,
includinginterferencethatmaycauseundesired
operation.
Thisequipmenthasbeentestedusingashielded
networkcable(STP)andfoundtocomplywiththe
limitsforaClassAdigitaldevice,pursuanttopart15
oftheFCCRules.Theselimitsaredesignedtoprovide
reasonableprotectionagainstharmfulinterference
whentheequipmentisoperatedinacommercial
environment.Thisequipmentgenerates,uses,andcan
radiateradiofrequencyenergyand,ifnotinstalledand
usedinaccordancewiththeinstructionmanual,may
causeharmfulinterferencetoradiocommunications.
Operationofthisequipmentinaresidentialareais
likelytocauseharmfulinterferenceinwhichcasethe
userwillberequiredtocorrecttheinterferenceathis
ownexpense.Theproductshallbeconnectedusinga
shieldednetworkcable(STP)thatisproperlygrounded.
Contactinformation
AxisCommunicationsInc.
300ApolloDrive
Chelmsford,MA0182
UnitedStatesofAmerica
Tel:+1978612000
Canada
Thisdigitalapparatuscomplieswith
CANICES-3(ClassA).Theproductshallbe
connectedusingashieldednetworkcable(STP)that
isproperlygrounded.Cetappareilnumériqueest
conformeàlanormeCANNMB-3(classeA).Leproduit
doitêtreconnectéàl'aided'uncâbleréseaublindé
(STP)quiestcorrectementmisàlaterre.
Europe
ThisdigitalequipmentfulllstherequirementsforRF
emissionaccordingtotheClassAlimitofEN55032.
Theproductshallbeconnectedusingashielded
networkcable(STP)thatisproperlygrounded.Notice!
ThisisaClassAproduct.Inadomesticenvironment
thisproductmaycauseRFinterference,inwhichcase
theusermayberequiredtotakeadequatemeasures.
Australia/Newealand
Thisdigitalequipmentfulllstherequirements
forRFemissionaccordingtotheClassAlimitof
AS/NZSCISPR32.Theproductshallbeconnected
usingashieldednetworkcable(STP)thatisproperly
grounded.Notice!ThisisaClassAproduct.Ina
domesticenvironmentthisproductmaycauseRF
interference,inwhichcasetheusermayberequired
totakeadequatemeasures.
Japan

この装置は、クラスA機器です。この装置を
住宅環境で使用すると電波妨害を引き起こす
ことがあります。この場合には使用者が適切
な対策を講ずるよう要求されることがありま
す。VCCI‒A
本製品は、シールドネットワークケーブル
(STP)を使用して接続してください。また適切
に接地してください。
本製品は電気通信事業者(移動通信会社、固
定通信会社、インターネットプロバイダ等)
の通信回線(公衆無線LANを含む)に直接接
続することができません。本製品をインター
ネットに接続する場合は、必ずルータ等を経
由し接続してください。
Korea
이기기는업무용환경에서사용할목적으로적
합성평가를받은기기로서가정용환경에서사
용하는경우전파간섭의우려가있습니다.적절
히접지된STP(shieldedtwistedpair)케이블을
사용하여제품을연결하십시오.
Safety
ThisproductcomplieswithIEC/EN/UL62368-1,
safetyofaudio/videoandITequipmentand
IEC/EN/UL60950-22,SafetyofInformation
TechnologyEquipment.Theproductshallbegrounded
usingboththeprotectiveearthwireinthepower
cableandthegroundingbraid.Makesurebothendsof
theprotectiveearthwireandthegroundingbraidare
incontactwiththeirrespectivegroundingsurfaces.
Thepowersupplyusedwiththisproductshallhave
aratedoutputvoltagewithinvoltagerangeof
20-28VAC/DC,andamaxcurrentratingof10.5A.
Thepowersupplyusedwiththisproductshallfulll
oneofthefollowingrequirements:
•SafetyExtraLowVoltage(SELV)accordingto
clause2.2ofIEC/EN/UL60950-1
•Class1electricalenergysource(ES1)according
toIEC/EN/UL62368-1
WerecommendtheuseofAxispowersupplyDINPS2
80W.
Whenthisproducthasreachedtheendofits
usefullife,disposeofitaccordingtolocallawsand
regulations.Forinformationaboutyournearest
designatedcollectionpoint,contactyourlocal
authorityresponsibleforwastedisposal.Inaccordance
withlocallegislation,penaltiesmaybeapplicablefor
incorrectdisposalofthiswaste.
Europe
Thissymbolmeansthattheproductshallnotbe
disposedoftogetherwithhouseholdorcommercial
waste.Directive2012/19/EUonwasteelectrical
andelectronicequipment(WEEE)isapplicablein
theEuropeanUnionmemberstates.Toprevent
potentialharmtohumanhealthandtheenvironment,
theproductmustbedisposedofinanapproved
andenvironmentallysaferecyclingprocess.For
informationaboutyournearestdesignatedcollection
point,contactyourlocalauthorityresponsiblefor
wastedisposal.Businessesshouldcontacttheproduct
supplierforinformationabouthowtodisposeofthis
productcorrectly.
Thisproductcomplieswiththerequirementsof
Directive2011/65/EUand2015/863ontherestriction
oftheuseofcertainhazardoussubstancesinelectrical
andelectronicequipment(RoHS).
China
Thisproductcomplieswiththerequirements
ofSJ/T1 136-201,Markingfortherestrictionof
hazardoussubstancesinelectricalandelectronic
products.
有毒有害物质或元素
部
件
名
称
铅
(Pb)汞
(Hg)镉
(Cd)六
价
铬
(Cr-
(VI))
多
溴
联
苯
(PB-
B)
多
溴
二
苯
醚
(PB-
DE)
电
气
实
装
部
分
X00000
0:表示该有毒有害物质在该部件均质材料
中的含量均在GB/T26572标准规定的限量要
求以下。
X:表示该有毒有害物质至少在该部件的某一
均质材料中的含量超出GB/T26572标准规定的
限量要求。
Contactinformation
AxisCommunicationsAB
Gränden1
22369Lund
Sweden
Tel:+662721800
Fax:+66136130
axis.com
Warrantyinformation
ForinformationaboutAxis’productwarrantyand
theretorelatedinformation,gotoaxis.com/warranty.
Support
Shouldyourequireanytechnicalassistance,please
contactyourAxisreseller.Ifyourquestionscannotbe
answeredimmediately,yourresellerwillforwardyour
queriesthroughtheappropriatechannelstoensurea
rapidresponse.IfyouareconnectedtotheInternet,
youcan:
•ndanswerstoresolvedproblemsintheFAQ
database,searchbyproduct,category,orphrase
•reportproblemstoAxissupportstaffbylogging
intoyourprivatesupportarea
•chatwithAxissupportstaff
•visitAxisSupportataxis.com/support
Learnmore!
VisitAxislearningcenteraxis.com/learningforuseful
trainings,webinars,tutorialsandguides.

AXIST99A12PositioningUnit24VAC/DC
Safetyinformation
Hazardlevels
DANGER
Indicatesahazardoussituationwhich,ifnotavoided,willresultindeathorseriousinjury.
WARNING
Indicatesahazardoussituationwhich,ifnotavoided,couldresultindeathorseriousinjury.
CAUTION
Indicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderate
injury.
NO NO
NOICE ICE
ICE
Indicatesasituationwhich,ifnotavoided,couldresultindamagetoproperty.
Othermessagelevels
Important
Indicatessignicantinformationwhichisessentialfortheproducttofunctioncorrectly.
Note
Indicatesusefulinformationwhichhelpsingettingthemostoutoftheproduct.
Safetyinstructions
DANGER
Riskofelectricshock.Allcablesshallbede-energizedbeforeinstallingorperforming
maintenanceontheproduct.
CAUTION
Movingparts.Riskofinjury.Keepyourbodypartsawayfromtheproductwhenit's
inoperation.Disconnectfrompowersupplybeforeinstallingorperformingmaintenance
ontheproduct.
CAUTION
Hotsurface.Riskofinjury.Don'ttouchtheproductwhenit'sinoperation.Disconnect
frompowersupplyandallowthesurfacestocoolbeforeperformingmaintenanceon
theproduct.
5

AXIST99A12PositioningUnit24VAC/DC
NO NO
NOICE ICE
ICE
•TheAxisproductshallbeusedincompliancewithlocallawsandregulations.
•StoretheAxisproductinadryandventilatedenvironment.
•AvoidexposingtheAxisproducttoshocksorheavypressure.
•Donotinstalltheproductonunstablepoles,brackets,surfacesorwalls.
•UseonlyapplicabletoolswheninstallingtheAxisproduct.Usingexcessiveforcewith
powertoolscouldcausedamagetotheproduct.
•Donotusechemicals,causticagents,oraerosolcleaners.
•Useacleanclothdampenedwithpurewaterforcleaning.
•Useonlyaccessoriesthatcomplywiththetechnicalspecicationofyourproduct.These
canbeprovidedbyAxisorathirdparty.AxisrecommendsusingAxispowersource
equipmentcompatiblewithyourproduct.
•UseonlysparepartsprovidedbyorrecommendedbyAxis.
•Donotattempttorepairtheproductyourself.ContactAxissupportoryourAxisreseller
forservicematters.
•Useayellow/greencoloredgroundingcableofatleast0.5mm2or20AWG.
Transportation
NO NO
NOICE ICE
ICE
•WhentransportingtheAxisproduct,usetheoriginalpackagingorequivalenttoprevent
damagetotheproduct.
6

AXIST99A12PositioningUnit24VAC/DC
Packagecontents
•Positioningunit
•Powerconnector
•I/Oconnector
•Torx®bitT20(long)andT30
7

AXIST99A12PositioningUnit24VAC/DC
Productoverview
1Positioningunit(tilt)
2Positioningunit(pan)
3Lid
4Baseunit
5Camera(notincluded)
8

AXIST99A12PositioningUnit24VAC/DC
1Illuminatorcables(nottobeused)
2Camerapowercable
3Cameranetworkcable
4Cameraserialinterfacecable
5Inputpowerconnector
6I/Oconnector
7RJ45connector
8SFPslotforSFPmodule(SFPmodulenotincluded)
9

AXIST99A12PositioningUnit24VAC/DC
owtoinstalltheproduct
DANGER
Riskofelectricshock.Allcablesshallbede-energizedbeforeinstallingtheproduct.
CAUTION
Theelectricalconnectionsandconduitinstallationsshallbemadebyacertiedelectrician
andincompliancewithlocalregulations.
CAUTION
Riskofinjury.Movingparts.Keepyourbodypartsawayfromtheproductwhenin
operation.Disconnectfrompowersupplybeforeinstallingorperformingmaintenance
ontheproduct.
CAUTION
Riskofinjury.Hotsurface.Donottouchtheproductwheninoperation.Disconnect
frompowersupplyandallowthesurfacestocoolbeforeperformingmaintenanceon
theproduct.
Mounttheaseunit
1Baseunit
1.Removethefourbaseunitscrews(T30).
2.Simultaneouslypullandturnthebaseunitcounterclockwiseuntilthearrowsonthebase
unitandtherestofthepositioningunitalign.
10

AXIST99A12PositioningUnit24VAC/DC
3.Removethebaseunit.
NO NO
NOICE ICE
ICE
Donotusesharptoolswhenyouremovethetransparentbaseunitcover.
.Removethetransparentbaseunitcover.
11

AXIST99A12PositioningUnit24VAC/DC
1Conduitcoverclip
2Conduitcover
3Screwhole(x4)
5.Forconduitinstallationsonly:removethetwoconduitcoverclipsfollowedbythe
conduitcover.
6.Attachthebaseunittothemountingsurfacewithappropriatefastenersinthefour
screwholes.
Routethecales
WARNING
Riskofelectricshock.Theproductshallbegroundedusingboththeprotectivegrounding
wireinthepowercableandthegroundingbraid.Makesurebothendsoftheprotective
groundingwireandthegroundingbraidareincontactwiththeirrespectivegrounding
surfaces.
Important
Useonlycablesthatcomplywiththespeciedcablearea.Formoreinformation,see
Cablethicknessonpage27.
12

AXIST99A12PositioningUnit24VAC/DC
1Powercable(notincluded)
2Strainrelief
3Groundingscrew
4Groundingbraid(notincluded)
5Bottomcablehole
1.Installtheoptionalconduitadapters(notincluded).
2.Connectthegroundingbraidtothegroundingscrew.
3.Insertthepowercable,I/Ocableandnetworkcablethroughtheholeinthebaseunitas
shownintheillustrationabove.Alternativelyinsertthemthroughthebottomcablehole.
.Insertthepowercablethroughthestrainreliefwithadistanceof530mm(21in)from
thestrainrelieftotheendofthecable.
13

AXIST99A12PositioningUnit24VAC/DC
1I/Ocable(optional,notincluded)
2Networkcable(notincluded)
5.InserttheI/Ocable(optional)throughthestrainreliefwithadistanceof20mm(16.5
in)fromthestrainrelieftotheendofthecable.
6.Insertthenetworkcable(opticalbercableand/orRJ5cable)throughthestrainrelief
withadistanceof580mm(23in)fromthestrainrelieftotheendoftheconnector.
Formoreinformationondifferentnetworkconnectivityoptions,seeInstallthenetwork
linkonpage17.
7.Closeandtightenthethreestrainreliefs.
14

AXIST99A12PositioningUnit24VAC/DC
1Powercable(notincluded)
2I/Ocable(optional,notincluded)
3Networkcable(notincluded)
4Cablegasket
5ransparentbaseunitcover
8.Fitcablegasketsonthecables.SeeCablethicknessonpage27.
9.Insertthepower,I/Oandnetworkcablesincludingthecablegasketsthroughtheholesin
thetransparentbaseunitcoverandarrangethecablesasshownintheillustrationabove.
NO NO
NOICE ICE
ICE
IfyouusebothanopticalbrecableandanRJ5cablefornetworkconnectivity,routethe
opticalbrecablethroughthesamecablegasketastheI/Ocable.Applyasealantbetween
thecablesandthecablegaskettopreventleakage.Formoreinformationondifferent
networkconnectivityoptions,seeInstallthenetworklinkonpage17.
15

AXIST99A12PositioningUnit24VAC/DC
10.Placethetransparentbaseunitcoveronthebaseunitandtthecablegasketsinside
theholes.
1I/Oconnector
2Powerconnector
3O-ring
NO NO
NOICE ICE
ICE
Tonotaccidentallydisconnecttheunitfrompowerifthecableispulled,lettheprotective
groundingwirebeabout10mm(0.in)longerthantheothertwowires(inthepower
cable).
Note
Tomaketheinstallationaseasyaspossible,werecommendyoutostripapproximately90
mm(3.5in)ofthepowercablejacketand70mm(2.8in)oftheI/Ocablejacket.
11.InstallthepowerandI/Oconnectors.
12.Adjustthenetwork,I/Oandpowercablessothatthedistancefromthecablegasketto
theendoftheconnectoris20mm(10in),170mm(7in),and160mm(7in)respectively.
NO NO
NOICE ICE
ICE
MakesurethattheO-ringisttedcorrectlyaroundthetransparentbaseunitcover.
16

AXIST99A12PositioningUnit24VAC/DC
13.Placethepositioningunitonthebaseunit.Makesurethatthearrowsonthetwo
unitsarealigned.
1.Turnthepositioningunitclockwisebacktoitsoriginalpositionandtightenthefour
baseunitscrews(torque3.0Nm).
NO NO
NOICE ICE
ICE
Makesurethatthecablesdon’tgetpinchedwhenyouassemblethetwounits.
17

AXIST99A12PositioningUnit24VAC/DC
Installthenetworklink
Youcanchoosebetweendifferentoptionswhenyouinstallthenetworklink:
•A:viaanopticalberorRJ5cableconnectedtotheSFPmodule(witharespective
connector)intheSFPslot.
•B:viaanRJ5cableconnectedtothexedRJ5connector.
•C:viabothoftheabove,inwhichcasetheSFPmoduleconnectionfunctionsasthe
primarynetworklink,andthexedRJ5connectionfunctionsasthefail-overlink.
Formoreinformationonnetworkconnectorlocations,seeProductoverviewonpage8.
Note
•SFPmoduleisnotincluded.FormoreinformationonavailableSFPmodules,seeaxis.com
•IfyouinstallanetworklinkonlyviatheopticalbercableusingtherespectiveSFP
module,itworksasastand-alonesolutionforlongrangecablinginstallations.
Installthecamera
NO NO
NOICE ICE
ICE
•Thisproductsupportsseveralcameramodels.Foracompletelistofsupportedcameras,
seetheproductpageataxis.com.
•Forinstructionsonhowtoopenthecameracover,seethecamera’sinstallationguide.
18

AXIST99A12PositioningUnit24VAC/DC
1.Removethecablegasketsfromthecamera’sbottomcover.
2.Insertthenetwork/power/serialinterfacecabletroughtheholesinthebottomcover.
3.Fitthebottomcoveronthepositioningunit.
19

AXIST99A12PositioningUnit24VAC/DC
.Tiltthebottomcoverbackwardtoitsendpositionandtightenthetwofrontscrewsof
thepositioningunit(T20,torque3.0Nm).
20
Other manuals for T99A12
1
Table of contents
Other Axis Valve Positioner manuals
Popular Valve Positioner manuals by other brands

Samson
Samson 3730-0 Mounting and operating instructions

Spirax Sarco
Spirax Sarco PP6 quick start guide

metso automation
metso automation neles NP Series Installation maintenance and operating instructions

Baker Hughes
Baker Hughes Masoneilan SVi 1000 instruction manual

Emerson
Emerson Fisher 3610J instruction manual

Prior
Prior NanoScan OP400 Quick start instructions