Product escription aily Maintenance
This machine mainly uses high-quality components such as single-ended ultraviolet
lamps, air circulation devices, air filter devices, etc Through the built-in single-ended
ultraviolet sterilization and disinfection module, the disinfection and sterilization air
is discharged in the indoor air for many cycles, to realize strong sterilization and high
-efficiency purification, reduce droplet infection and aerosol transmission
All the sterilization machine model produced by our company are equipped with
ultraviolet disinfection (man-machine symbiosis)function
High quality nylon washable primary filter,
Medical grade H13 fiberglass HEPA, PM 2 5 and the other tiny particles removal
efficiency 99 9%-99 97%@0 3μm
Ultra-large adsorption area honeycomb activated carbon filter, with volume up to
800X400x10mm,effectively remove formaldehyde
Technical Parameters
Circulation air volume 1000m³/h UVC lamp power 8 8W
Voltage/Rated power
100-127V~60Hz
(
145W
)
220-240V~50Hz
(
163W
)
UV lamp life ≈8000H Noise
≤
68dB
Bactericidal rate
(staphylococcus albicans)
≥
99 9%
Natural bacteria extinction rate
≥
99 9%
UV radiation intensity(1 meter vertically below the lamp) 18uW/cm²
UV leakage
(30cm around the device)
≤
1uW/cm
²
Ozone residual concentration
≤
0 005mg/m
³
Machine size
875*492*365mm
Ambient temperature 5℃-40℃ Relative humidity
≤
80%
Check item How to check Frequency
external wiring visually check for looseness 3 months
Centrifugal fan
and motor
the centrifugal fan must rotate smoothly without
generating abnormal sound If abnormal sound is
heard, please confirm whether there is foreign
matter in the blower and whether the noise of the
motor bearing is abnormal If the motor has
problems, please replace it
12 months
Pre filter to check whether the surface is damaged; cleaned
every 3 months 3 months
UV lamp to check the lamp tube every six months for damage 6 months