Baaske Medical e-medic Silence TP 10 User manual

i
V1.0
Photographs and Schematic diagrams used in this document are for illustration purposes
only. The actual product may vary. Technical changes and errors accepted. Rev.1 10.2022
Baaske Medical GmbH & Co. KG • Bacmeisterstr. 3 • D-32312 Lübbecke •
www.e-medic.de.com
e-medic™ — the brand of Baaske Medical GmbH & Co. KG

ii
Version Change History
Date
Version
Description
Remark
2022/10/19
1.0
First Release

iii
Acknowledgments
Intel® Celeron processor is registered trademarks of Intel®
Corporation.
IBM, PC/AT, PS/2 are trademarks of International Business
Machines Corporation.
Microsoft® Windows is a registered trademark of Microsoft®
Corporation.
RTL is a trademark of Realtek Semi-Conductor Co., Ltd.
C&T is a trademark of Chips and Technologies, Inc.
UMC is a trademark of United Microelectronics Corporation.
ITE is a trademark of Integrated Technology Express, Inc.
Intel is a trademark or registered trademark of Intel
Corporation.
Winbond is a registered trademark of Winbond Electronics
Corporation.
All other product names or trademarks are properties of
their respective owners.

iv
FCC Class B
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 18 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a residential
environment.
This equipment generates, uses and can radiate radio frequency energy. If
not installed and used in accordance with this user manual, it may cause
harmful interference to radio communications.
Note that even when this equipment is installed and used in accordance
with this user manual, there is still no guarantee that interference will not
occur. If this equipment is believed to be causing harmful interference to
radio or television reception, this can be determined by turning the
equipment on and off. If interference is occurring, the user is encouraged
to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and the receiver
Connect the equipment to a power outlet on a circuit different from
that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
Warning:
Any changes or modifications made to the equipment which are
not expressly approved by the relevant standards authority could
void your authority to operate the equipment.
To avoid risk of electric shock, this equipment must only be
connected to a supply mains with protective earth.
Do not modify this equipment without authorization of the
manufacturer.
Avertissement:
Tous les changements ou modifications apportés à l'équipement
qui ne sont pas expressément approuvés par l'autorité de
normalisation compétente peuvent annuler votre droit d'utiliser
l'équipement.
Pour éviter tout risque de choc électrique, cet équipement ne doit
être connecté qu'à un réseau d'alimentation avec terre de
protection.

v
Ne modifiez pas cet équipement sans l'autorisation du fabricant.

vi
Safety Instructions
Intended use
The TP 10 is intended to serve as a medical monitor which is
designed for general purpose for hospital environment. It shall
not be used for life-supporting system.
Intended User profile
The equipment is intended for infant or adults by profession
Health care professionals.
Greeting & Setup
Thank you for purchasing the TP 10 unit. We wish that this unit
will be durable and reliable in providing your medical application
needs. Please follow the instructions below to ensure the unit
continues to have high performance.
Unpacking
After opening the carton, there will be a medical panel PC unit
with an accessory box. Examine the contents to see if there are
damages to the unit and if all accessories are present.
Setting up
Please read this manual carefully and remember to keep this
manual for future reference.
Safety Instructions & Cleaning
The unit has undergone various tests in order to comply with
safety standards. Inappropriate use of the open frame unit may
be dangerous. Please remember to follow the instructions below
to insure your safety during the installation and operating
process.
Transporting & Placement of unit
1. When moving the unit on a cart; be very cautious. Quick
stops, excessive forces and uneven surfaces may cause
the cart to overturn thus risking the unit to fall to the
ground.

vii
2. If the medical panel PC unit does fall to the ground,
immediately turn the power off and disconnect cords. Then
contact a service technician for repairs. Continual use of
the unit may result cause a fire or electric shock. Also, do
not repair the unit on your own.
3. Having two or more people transporting the display unit is
recommended. In addition, when installing the unit by
suspending it also requires two or more people.
4. Before suspending the unit, make sure the material used
for suspension is sturdy and stable. If not properly
suspended, the display unit may fall and cause serious
injury to people standing nearby as well as to the unit
itself.
5. If you wish to mount the display unit, remember to use
only the mounting hardware recommended by the
manufacturer.
Electrical and Power Source Related
1. This medical panel PC unit must operate on a power source
as shown on the specification label. If you are not sure
what type of power supply used in the area, consult your
dealer or local power supplier.
2. The power cords must not be damaged. Applied pressure,
added heat, and tugging may damage the power cord.
3. The power cord must be routed properly when setup takes
place. We advise that this aspect measure is to prevent
people from stepping on the cords or while the unit is
suspended to prevent flying objects from getting tangled
with the unit.
4. For plug-in equipment, the power outlet socket must be
located near the equipment and must be easily accessible.
5. Do not overload the AC outlets or extension cords.
Electrical shocks or fires may occur from overloading.
6. Do not touch the power source during a thunderstorm.
7. If your hands are wet, do not touch the plug.

viii
8. Use your thumb and index finger, grip firmly on the power
cord to disconnect from the electrical socket. By pulling
the power cord, may result in damaging it.
9. If the unit is not going to be in use for an extended period
of time, remember to disconnect the unit.
10. The medical panel PC unit uses voltage between
100-240VAC. Connect the unit to a power source with the
same numerical value as shown. Please use only the power
cord provided by the dealer to ensure safety and EMC
compliance.
Various Factors of Environment
1. Do not insert objects into the openings.
2. Do not have liquids seep into the internal areas of the
medical panel PC unit.
3. Having liquids seep in or inserting objects into the unit
may result in electric shocks from taking and/or short
circuiting the internal parts.
4. Do not place the medical panel PC unit in the presence of
high moisture areas.
5. Do not install the medical panel PC unit in a wet
environment.
6. Do not place near unit near heat generating sources.
7. Do not place the unit in a location where it will come in
contact with fumes or steam.
8. Remember to keep the medical panel PC unit away from
the presence of dust.
9. If water has flow in or seep in, immediately disconnect the
open frame unit. Then contact a service technician for
repairs.
Ventilation Spacing
1. Do not cover or block the openings on the top and back
sides of the display unit. Inadequate ventilation may cause
overheating thus reducing the lifespan of the unit.

ix
2. Unless proper ventilation is present, do not place unit in an
enclosed area; such as a built-in shelf. Keep a minimum
distance of 10 cm between the display unit and wall.
Operating principle
A Medical Panel PC has four main components: the
arithmetic logic unit (ALU), the control unit, the memory,
and the input and output devices (collectively termed I/O).
These parts are interconnected by buses, often made of
groups of wires.
The control unit, ALU, and registers are collectively known
as a central processing unit (CPU).
Inside each of these parts are thousands to trillions of small
electrical circuits which can be turned off or on by means of
an electronic switch. Each circuit represents a bit (binary
digit) of information so that when the circuit is on it
represents a "1", and when off it represents a "0" (in positive
logic representation). The circuits are arranged in logic gates
so that one or more of the circuits may control the state of
one or more of the other circuits.
Cleaning the unit
1. Remember to turn off the power source and to unplug the
cord from the outlet before cleaning the unit.
2. Carefully dismount the unit or bring the unit down from
suspension to clean.
3. Please use a dry soft cloth to clean the unit.
4. Take a dry cloth and wipe the unit dry. Remember to avoid
having liquids seep into the internal components and areas
of the medical panel PC unit.
5. Cleaning unit each time before use.
Error message / Troubleshooting
No power
1. Connect the AC adapter to the computer, and
then plug it into an AC outlet.

x
2. Turn on the computer.
Servicing, Repairing, Maintenance & Safety Checks
1. If the unit is not functioning properly, observe the
performance level of the display closely to determine what
type of servicing is needed.
2. Do not attempt to repair the medical panel PC unit on your
own. Disassembling the cover exposes users’ to high
voltages and other dangerous conditions. Notify and
request a qualified service technician for servicing the unit.
3. To avoid risk of electric shock, this equipment must only
be connected to a supply mains with protective earth.
4. If any of the following situations occur turn the power
source off and unplug the unit. Then contact a qualified
service technician.
(a) A liquid was spilled on the unit or objects have fallen
into the unit.
(b) The unit is soaked with liquids.
(c) The unit is dropped or damaged.
(d) If smoke or strange odor is flowing out of the operating
unit.
(e) If the power cord or plug is damaged.
(f) When the functions of the unit are dysfunctional.
5. When replacement parts are needed for the medical panel
PC unit, make sure service technicians use replacement
parts specified by the manufacturer, or those with the
same characteristics and performance as the original
parts. If unauthorized parts are used it may result in
starting a fire, electrical shock and/or other dangers.

xi
ISO 7000-0434: Caution
IEC 60417 -5009: STAND-BY.
IEC 60417-5031: Direct current.
EU-wide legislation, as implemented in each
Member State, requires that waste electrical and
electronic products carrying the mark (left) must be
disposed of separately from normal household
waste. This includes monitors and electrical
accessories, such as signal cables or power cords.
When you need to dispose of your display products,
please follow the guidance of your local authority, or
ask the shop where you purchased the product, or if
applicable, follow any agreements made between
yourself.
The mark on electrical and electronic products only
applies to the current European Union Member
States.

xii
Caution:
DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED
ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW
-20° C (-4° F) OR ABOVE 60° C (140° F). THIS MAY DAMAGE THE
EQUIPMENT.
This equipment shall not be used in life support systems.
The user is not to touch SIP/SOPs and the patient at the same
time.
Caution – Use suitable mounting apparatus to avoid risk of injury.
Caution - Risk of explosion if battery is replaced by an incorrect
type. Dispose of used batteries according to the instructions.
(If battery pack is not used for 1 month, it is recommended to
remove the battery pack from equipment.)
The sound pressure level at the operator’s position according to
IEC 704-1:1982 is no more than 70dB (A).
A) Grounding reliability can only be achieved when the equipment
is connected to an equivalent receptacle marked “Hospital
Only” or “Hospital Grade”.
B) Use a power cord that matches the voltage of the power outlet,
which has been approved and complies with the safety
standard of your particular country.
C) Caution: This adapter Sinpro HPU180A-108is a forming part of
the medical device (TP 10)
Mise en garde:
NE LAISSEZ PAS CET ÉQUIPEMENT DANS UN ENVIRONNEMENT
NON CONTRÔLÉ OERE LA TEMPÉRATURE DE STOCKAGE EST
INFÉRIEURE À -20 ° C (-4 ° F) OU SUPÉRIEURE À 60 ° C (140 ° F).
CELA POURRAIT ENDOMMAGER L'ÉQUIPEMENT.
Cet équipement ne doit pas être utilisé dans les systèmes de
survie.
L'utilisateur ne doit pas toucher les SIP / SOP et le patient en
même temps.

xiii
Attention - Utilisez un appareil de montage approprié pour éviter
tout risque de blessure.
Attention - Risque d'explosion si la batterie est remplacée par un
type incorrect. Jetez les piles usagées conformément aux
instructions.
(Si la batterie n'est pas utilisée pendant 1 mois, il est
recommandé de retirer la batterie de l'équipement.)
Le niveau de pression acoustique au poste de l'opérateur selon
CEI 704-1: 1982 n'est pas supérieur à 70 dB (A).
A) La fiabilité de la mise à la terre ne peut être obtenue que
lorsque l'équipement est connecté à une prise équivalente
marquée «Hospital Only» ou «Hospital Grade».
B) Utilisez un cordon d'alimentation qui correspond à la tension
de la prise de courant, qui a été approuvée et conforme aux
normes de sécurité de votre pays.
C) Attention: cet adaptateur Sinpro HPU180A-108 (TP 10) fait
partie intégrante du dispositif medical
Contact information:
Baaske Medical GmbH & Co. KG
Bacmeisterstraße 3
32312 Lübbecke
Germany
Tel: +49 5741 236027-0
E-mail: sales@e-medic.com

xiv
Table of Contents
Acknowledgments........................................................iii
FCC Class B....................................................................iv
Safety Instructions......................................................vi
Introduction ......................................................... 1
Product Description......................................................1
Package list .....................................................................2
Features ...........................................................................3
Specifications ................................................................. 4
Cleaning/Disinfecting ................................................11
Getting Started.................................................. 12
System Set Up.............................................................12
Dimension......................................................................14
System View................................................................. 15
A. Battery Pack Specifications (optional kit)....20
B. Scrap Computer Recycling ................................21

TP 10 User’s manual
1
Introduction
Product Description
The TP 10 Medical Panel PC is based on 10th generation Core i
CPU (Socket LGA1200) processor, it accommodates one M.2
M.Key 2280 PCIe X 4 SSD and Two up to 64GB DDR4 SODIMM.
The Fanless (TP 10) solution, integrated multimedia functions
and extensive expansion options make them the perfect platform
upon which to build comprehensive lifestyle computing
applications.
The TP 10 includes all the features of a powerful computer into a
slim and attractive chassis.
The TP 10 is compact, Giga LAN and selectable WLAN network
compatible PC with full safety and medical approval and features
to control a dedicated system with a wide variety of applications.
Combining the TP 10 into your system can achieve both
cost-saving and efficient improvements.
Common applications include LIS (Lab Information Systems) and
Electronic Medical Record. The TP 10 are definitely your perfect
choices.

TP 10 User’s manual
2
Package list
Before you begin installing your Medical Station, please make
sure that the following items have been shipped:
•The TP 10 Medical Panel PC unit
•Power Adapter x 1 (Mf:Sinpro, type/model: HPU180A-108)
•User's manual, chipset drivers
•Power cord – Hospital grade used (US type), or other type in
UK, EU…etc.
•Screw x4 (VESA 100 mm use)

TP 10 User’s manual
3
Features
Anti-bacteria (MRSA) plastic housing
23.8" full HD (1920X1080) MVA Diagnostic Panel
High performance intel 10th generation COMET Lake Core i
CPU (Socket LGA1200)
Supports Dual Channel DDR4 SODIMM up to 64GB
P.cap Multi-Touch Screen
Fast booting with M.2 M.Key 2280 PCIe X 4 SSD (Support
NVMe SSD) as drive disk
Supports PCI-E x16 slot
Fanless solution
Support RAID 0,1
Optional Full HD capture card
LAN/COM/USB 4KV isolated module (optional order
configuration)
Optional DICOM part 14 compliance solution. (optional order
configuration)

TP 10 User’s manual
4
Specifications
[
Hardware Specifications
Display 24” 250 nits 1920x1080 TFT LCD (TP 10)
CPU Support
LGA1200 package 10th generation Intel® Core
i7/i5/i3/Pentium/Celeron processor (35W max.)
Disk Drive Space
M.2 M.Key 2280 PCIe X 4 SSD (Support NVMe
SSD),3.3Vdc, 3A max.
Optional 2.5” SATA SSD or HDD drive bay x 1 with
doggy door (5Vdc, 1.5A max.)
Expansion
One M.2 Type E slot (optional connect to WiFI
module);
One M.2 Type B/M slot
One PCI-E x 16 expansion slot (optional connected
to Capture card board, for Standard version used
only);
Button
Power // Audio adjustment (+)(-) // brightness (+)(-)
// Reading Light // Video input selection // LCD
on/off // Clean me(auto release after 1 minute) // Fn
TP 10 I/O
Standard version
RS-232 port *1 + RS-232/422/485 port *1
USB 3.2 gen 2 port *4
Gigabit LAN RJ-45 Connectors *2
DP output *1
HDMI output *1
HDMI-IN *1
Sound:
Line-in *1
Line-out *1
Isolated version
Isolated 4KV GigaLAN *1
Isolated 4KV USB 2.0 *1
Isolated 4KV Isolated 4KV RS-232/422/485 *1 &
RS-232 port *1
(The isolated ports verified through Dielectric test
4000Vac only)
USB 3.2 gen 2 port *4
Gigabit LAN RJ-45 Connectors *2
DP output *1
HDMI output *1
HDMI-IN *1
Sound:
Line-in *1
Line-out *1

TP 10 User’s manual
5
LCD Specifications
Model Name
TP 10
Display Type
23.8” LED
Max. Resolution
1920 x 1080
Contrast Ratio
3000 : 1 (Typ)
Pixel Pitch (mm)
274.5 (per one triad) × 274.5
Luminance (cd/m2)
250 (TYP)
Viewing Angle
178°(H)
178°(V)
Cautions:
Continuous displaying fixed pattern may induce image sticking.
It’s recommended to use screen saver or moving content
periodically if fixed pattern is displayed on the screen.
Précautions:
L'affichage continu d'un motif fixe peut provoquer le collage de
l'image. Il est recommandé d'utiliser l'économiseur d'écran ou de
déplacer régulièrement du contenu si un motif fixe est affiché à
l'écran.
Power Adapter Specifications
Power
Close-frame
MFR
Sinpro
Type
HPU180A-108
Input Rating
AC 100 ~ 240 V, 2.2-0.9A, 47 ~ 63 Hz
Output Rating
DC 24V, 7.5A
MTBF
100,000 hrs operation at 25°C
Classification
Power by Class I certified power adapter.
No applied part.
Mode of operation
Continuous operation
System input rating
DC 24V, 7.5A
Mechanical Specifications
Architecture
Close-frame
Front Bezel
PCT touch
Color
Medical-white
Mounting / Holder
VESA 100mm

TP 10 User’s manual
6
Construction
3mm ABS + PC TYPE Plastic housing
Dimension (WxHxD)
606 x 398 x 65.6 mm
Net Weight
TP 10: 9.7kg (w/o power adapter)
Packing Filler
PE
Environmental Specifications
Temperature
Operating:
AC 100-240V 0~35℃(32°F ~104°F)
Storage, Transportation: -20°C to 60°C (-4°F
~140°F)
Humidity
Operating:
10% to 90%@ 30°C, non-condensing
Storage, Transportation:
10% to 90%, non-condensing
Vibration
Operating: 15g/0.53 oz, 11 ms, half sine wave
Non-
operating: 50g/1.76 oz, 11 ms, half sine
wave
Shock
Operating: 5 ~ 17 Hz ,
Amplitude:0.117 ~ 500Hz ,
Acceleration:1.0G
Non-operating:10~55Hz/0.15g, 55~500Hz/2.0g
Altitudes
Operational: up to 3000 m (9842 feet)
Shipping: up to 12192 m (40000 feet)
Pressure
700 – 1060 hPa (Operation)
186 – 1060 hPa (Storage)
186 – 1060 hPa (Transportation)
EMI / Safety
CE / FCC / VCCI Class B
IP
IP65 at front side, IPx1 whole system
Touch Screen
P.cap touch
Type
Full flat projective capacitive touch panel
Interface
Controller with USB interface, 5V
Resolution
100ppi to 25ppi Based WIN7 definition ppi
(Pixel per inch)
Light Transmission
90% ± 3%
Life Time
100M times
Guidance and manufacturer’s declaration – electromagnetic
emissions
Table of contents
Other Baaske Medical Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Barco
Barco CORONIS 1MP Installation & user manual

ZacUrate
ZacUrate 500E user manual

Ultimate Healthcare
Ultimate Healthcare Heritage II Digital Turn Quick reference guide

LifePort
LifePort Kidney Transporter 1.1 Operator's manual

BEYES
BEYES APEXPILOT ALL-IN-ONE Operation manuals

apollo endosurgery
apollo endosurgery OverStitch ESS-G02-160 Instructions for use