M-Series® M5000
Firmware Upgrade
MAG-UM-00945-EN-02 (August 2014) Installation Manual
PREPARING FOR THE FIRMWARE UPGRADE
Meters that currently have version 1.x firmware can be upgraded
only to the latest 1.x firmware. Meters that currently have version
2.x firmware can be upgraded to the latest 2.x firmware. If you have
1.x firmware and wish to upgrade to 2.x firmware, you will need to
upgrade the board.
Download the latest firmware version from our website at
www.badgermeter.com to your hard drive. With the Flow Meter Tool
software installed, connect the laptop to the meter using either the
supplied RS232 cable or an IrDA adapter.
OTE:N The M5000 Data Logging kit (p/n 67354-008) is needed to
perform the firmware upgrade. See the M5000 Data
Logging Installation Manual.
RS232 Connection
1. Identify / Congure the meter’s communication settings:
a. Navigate to Communications > Interface.
b. Set the interface to SERIAL.
OTE:N The interface must be set to SERIAL. All other settings
can be set as desired by the operator and must match
those settings of the software tool.
c. Record or change other interface parameters (parity
and baud rate).
2. Connect the supplied RS232 cable into the RS232 connector of
the meter. Either connect the serial connector to a COM port or
connect it to the USB adapter.
3. Open the Flow Meter Tool installed on the laptop or PC. Go to
Start > All Programs > Badger Meter to open the ow meter tool
application.
4. To congure the ow meter tool software communication
settings:
a. Select Communication Settings.
b. Change the following parameters as necessary to
align with the meter settings:
• MODBUS ADDRESS (Node Address)
• BAUD RATE (9600)
• DATA BITS (default is 8)
• PARITY
• STOP BITS (default is 1)
c. Select OK to confirm the configuration of the
communication port. Make sure you select the
correct COM port.
OTE:N The M5000 communicates via the COM port and IrDA.
TCP/IP is not supported.
IrDA Connection
1. Identify / Congure the meter’s communication settings:
a. Navigate to Communications > Interface.
b. Set the interface to IrDA.
OTE:N The interface must be set to IrDA. All other settings can
be set as desired by the operator and must match those
settings of the software tool.
3. On the M5000 enclosure, install the IrDA bracket. Then install
the IrDA cable.
4. Connect the IrDA cable from the M5000 to the laptop.
5. If necessary, install the rDA link drivers from the CD. The IrDA
link uses a USB/IrDA converter and drivers. You may have to
restart your computer after installing the drivers.
M-Series® M5000, Firmware Upgrade
Page 2 August 2014
When the IrDA communication is activated, an icon appears on the
lower part of your screen.
The Wireless Link icon in the taskbar is a function of Windows®, not
the Flow Meter Tool.
6. In the Flow Meter Tool, select IrDA from the Communication
Settings menu. If there are multiple IrDA interfaces, make sure
you select the right one.
UPGRADING THE FIRMWARE
1. Make sure you have downloaded the latest firmware version
from http://www.badgermeter.com/Industrial/Industrial-
Municipal-Products/Electromagnetic-Flow-Meters/M-5000-Mag-
Meter.aspx to your hard drive.
2. From the Flow Meter Tool, click on Update Flow Meter
rmware.
3. Click on Select rmware le…
4. Navigate to the location where you saved the
rmware le.
5. Select the new M5000 rmware le.
6. Click on Start.
7. The firmware update will delete all data logging files to free
space on the flash drive for the upload firmware file. You must
confirm the deletion (or interrupt it and download data logs).
8. The Flow Meter Tool starts uploading the firmware file to the flow
meter.
Installation Manual
Page 3August 2014
9. After the upload is finished, the M5000 is restarted to start the
firmware update on it.
During the update, the M5000 displays this
informational message.
10. When the update is complete, the M5000 displays the firmware
date.
11. You are prompted to reset the connected Flow Meter to nish
the rmware update. Click Yes.
12. After reset, the Flow Meter Tool shows the new
rmware version.
www.badgermeter.com
M-SERIES and ORION are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous
research, product improvements and enhancements, Badger Meter reserves the right to change product or system specications without notice, except to the extent an
outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved.
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400
México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882
Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0
Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503
Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411
Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01
Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-04 Parkway Parade | Singapore 449269 | +65-63464836
China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412 IOM-841-01-EN 53400-841
Control. Manage. Optimize.

Other manuals for ModMAG M Series

2

This manual suits for next models

1

Other Badger Meter Measuring Instrument manuals

Badger Meter Dynasonics TFX-5000 User manual

Badger Meter

Badger Meter Dynasonics TFX-5000 User manual

Badger Meter DN15 User manual

Badger Meter

Badger Meter DN15 User manual

Badger Meter Impeller Data Industrial 228PV Series User manual

Badger Meter

Badger Meter Impeller Data Industrial 228PV Series User manual

Badger Meter ORION SE Installation and user guide

Badger Meter

Badger Meter ORION SE Installation and user guide

Badger Meter Blancett B2800XP User manual

Badger Meter

Badger Meter Blancett B2800XP User manual

Badger Meter 2100R+ User manual

Badger Meter

Badger Meter 2100R+ User manual

Badger Meter iSonic 4000 User manual

Badger Meter

Badger Meter iSonic 4000 User manual

Badger Meter ORION User manual

Badger Meter

Badger Meter ORION User manual

Badger Meter Dynasonics DFX Series User manual

Badger Meter

Badger Meter Dynasonics DFX Series User manual

Badger Meter FC-5000 User manual

Badger Meter

Badger Meter FC-5000 User manual

Badger Meter ModMAG M1000 User manual

Badger Meter

Badger Meter ModMAG M1000 User manual

Badger Meter M5000 User manual

Badger Meter

Badger Meter M5000 User manual

Badger Meter Hedland PE User manual

Badger Meter

Badger Meter Hedland PE User manual

Badger Meter ModMAG M2000 User manual

Badger Meter

Badger Meter ModMAG M2000 User manual

Badger Meter LM OG-TAER Specification sheet

Badger Meter

Badger Meter LM OG-TAER Specification sheet

Badger Meter M-series User manual

Badger Meter

Badger Meter M-series User manual

Badger Meter ER-500 Owner's manual

Badger Meter

Badger Meter ER-500 Owner's manual

Badger Meter Hedland EZ-View H915 User manual

Badger Meter

Badger Meter Hedland EZ-View H915 User manual

Badger Meter Blancett B2800 Standard Owner's manual

Badger Meter

Badger Meter Blancett B2800 Standard Owner's manual

Badger Meter Blancett 1100 Series User manual

Badger Meter

Badger Meter Blancett 1100 Series User manual

Badger Meter Cox User manual

Badger Meter

Badger Meter Cox User manual

Badger Meter Data Industrial 3000 Series User manual

Badger Meter

Badger Meter Data Industrial 3000 Series User manual

Badger Meter PortaSonic 9000 User manual

Badger Meter

Badger Meter PortaSonic 9000 User manual

Badger Meter FC-5000 User manual

Badger Meter

Badger Meter FC-5000 User manual

Popular Measuring Instrument manuals by other brands

Hanna Instruments PCA 300 Series instruction manual

Hanna Instruments

Hanna Instruments PCA 300 Series instruction manual

DMQ QS3 Series user manual

DMQ

DMQ QS3 Series user manual

Leica Leica UTILIFINDER+ user manual

Leica

Leica Leica UTILIFINDER+ user manual

Primes Cube M operating manual

Primes

Primes Cube M operating manual

Orion 24759 user manual

Orion

Orion 24759 user manual

Lumel ND20LITE User Manual & Quick Start

Lumel

Lumel ND20LITE User Manual & Quick Start

Stanley FATMAX FMHT77585 manual

Stanley

Stanley FATMAX FMHT77585 manual

Johnson 40-6064 instruction manual

Johnson

Johnson 40-6064 instruction manual

IN USA IN2000-L2-LC Operating and maintenance instructions

IN USA

IN USA IN2000-L2-LC Operating and maintenance instructions

Hach ORBISPHERE 410 Basic user manual

Hach

Hach ORBISPHERE 410 Basic user manual

Leica Jogger 20 user manual

Leica

Leica Jogger 20 user manual

Watts M100+ 28060 installation instructions

Watts

Watts M100+ 28060 installation instructions

Krystufek PANCONTROL 959875 manual

Krystufek

Krystufek PANCONTROL 959875 manual

Siemens MMB3-ALD-UK installation instructions

Siemens

Siemens MMB3-ALD-UK installation instructions

Hilti PD 38 quick start guide

Hilti

Hilti PD 38 quick start guide

LB Altimeters ARES II manual

LB Altimeters

LB Altimeters ARES II manual

Endress+Hauser LT5 operating instructions

Endress+Hauser

Endress+Hauser LT5 operating instructions

YOKOGAWA AQ6376 Getting started guide

YOKOGAWA

YOKOGAWA AQ6376 Getting started guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.