manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Badger Meter
  6. •
  7. Measuring Instrument
  8. •
  9. Badger Meter ModMAG M Series User manual

Badger Meter ModMAG M Series User manual

Other manuals for ModMAG M Series

2

This manual suits for next models

1

Other Badger Meter Measuring Instrument manuals

Badger Meter ORION Mobile Read Installation guide

Badger Meter

Badger Meter ORION Mobile Read Installation guide

Badger Meter Vortex VN2000 User manual

Badger Meter

Badger Meter Vortex VN2000 User manual

Badger Meter Recordall Disc Series User manual

Badger Meter

Badger Meter Recordall Disc Series User manual

Badger Meter Dynasonics DXN Series Use and care manual

Badger Meter

Badger Meter Dynasonics DXN Series Use and care manual

Badger Meter Preso Gemini Cone User manual

Badger Meter

Badger Meter Preso Gemini Cone User manual

Badger Meter CORIOLIS RCT1000 User manual

Badger Meter

Badger Meter CORIOLIS RCT1000 User manual

Badger Meter MN-MR100 Instructions and recipes

Badger Meter

Badger Meter MN-MR100 Instructions and recipes

Badger Meter Blancett B2900 User manual

Badger Meter

Badger Meter Blancett B2900 User manual

Badger Meter Cox User manual

Badger Meter

Badger Meter Cox User manual

Badger Meter LM OG Series Specification sheet

Badger Meter

Badger Meter LM OG Series Specification sheet

Badger Meter RCM 2000 User manual

Badger Meter

Badger Meter RCM 2000 User manual

Badger Meter Recordall RTR Orion 3-Wire Installation and user guide

Badger Meter

Badger Meter Recordall RTR Orion 3-Wire Installation and user guide

Badger Meter ORION SE Installation and user guide

Badger Meter

Badger Meter ORION SE Installation and user guide

Badger Meter epm-3 User manual

Badger Meter

Badger Meter epm-3 User manual

Badger Meter ER-9 User manual

Badger Meter

Badger Meter ER-9 User manual

Badger Meter FC-5000 User manual

Badger Meter

Badger Meter FC-5000 User manual

Badger Meter Primo Advanced BMAG-350-icpf Manual

Badger Meter

Badger Meter Primo Advanced BMAG-350-icpf Manual

Badger Meter epm-3 User manual

Badger Meter

Badger Meter epm-3 User manual

Badger Meter Dynasonics DXN User manual

Badger Meter

Badger Meter Dynasonics DXN User manual

Badger Meter FC-5000 User manual

Badger Meter

Badger Meter FC-5000 User manual

Badger Meter FMS-3 User manual

Badger Meter

Badger Meter FMS-3 User manual

Badger Meter Hedland T303 User manual

Badger Meter

Badger Meter Hedland T303 User manual

Badger Meter M-series User manual

Badger Meter

Badger Meter M-series User manual

Badger Meter Orion 64989-002 User manual

Badger Meter

Badger Meter Orion 64989-002 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

M-Series® M5000
Firmware Upgrade
MAG-UM-00945-EN-02 (August 2014) Installation Manual
PREPARING FOR THE FIRMWARE UPGRADE
Meters that currently have version 1.x firmware can be upgraded
only to the latest 1.x firmware. Meters that currently have version
2.x firmware can be upgraded to the latest 2.x firmware. If you have
1.x firmware and wish to upgrade to 2.x firmware, you will need to
upgrade the board.
Download the latest firmware version from our website at
www.badgermeter.com to your hard drive. With the Flow Meter Tool
software installed, connect the laptop to the meter using either the
supplied RS232 cable or an IrDA adapter.
OTE:N The M5000 Data Logging kit (p/n 67354-008) is needed to
perform the firmware upgrade. See the M5000 Data
Logging Installation Manual.
RS232 Connection
1. Identify / Congure the meter’s communication settings:
a. Navigate to Communications > Interface.
b. Set the interface to SERIAL.
OTE:N The interface must be set to SERIAL. All other settings
can be set as desired by the operator and must match
those settings of the software tool.
c. Record or change other interface parameters (parity
and baud rate).
2. Connect the supplied RS232 cable into the RS232 connector of
the meter. Either connect the serial connector to a COM port or
connect it to the USB adapter.
3. Open the Flow Meter Tool installed on the laptop or PC. Go to
Start > All Programs > Badger Meter to open the ow meter tool
application.
4. To congure the ow meter tool software communication
settings:
a. Select Communication Settings.
b. Change the following parameters as necessary to
align with the meter settings:
• MODBUS ADDRESS (Node Address)
• BAUD RATE (9600)
• DATA BITS (default is 8)
• PARITY
• STOP BITS (default is 1)
c. Select OK to confirm the configuration of the
communication port. Make sure you select the
correct COM port.
OTE:N The M5000 communicates via the COM port and IrDA.
TCP/IP is not supported.
IrDA Connection
1. Identify / Congure the meter’s communication settings:
a. Navigate to Communications > Interface.
b. Set the interface to IrDA.
OTE:N The interface must be set to IrDA. All other settings can
be set as desired by the operator and must match those
settings of the software tool.
3. On the M5000 enclosure, install the IrDA bracket. Then install
the IrDA cable.
4. Connect the IrDA cable from the M5000 to the laptop.
5. If necessary, install the rDA link drivers from the CD. The IrDA
link uses a USB/IrDA converter and drivers. You may have to
restart your computer after installing the drivers.
M-Series® M5000, Firmware Upgrade
Page 2 August 2014
When the IrDA communication is activated, an icon appears on the
lower part of your screen.
The Wireless Link icon in the taskbar is a function of Windows®, not
the Flow Meter Tool.
6. In the Flow Meter Tool, select IrDA from the Communication
Settings menu. If there are multiple IrDA interfaces, make sure
you select the right one.
UPGRADING THE FIRMWARE
1. Make sure you have downloaded the latest firmware version
from http://www.badgermeter.com/Industrial/Industrial-
Municipal-Products/Electromagnetic-Flow-Meters/M-5000-Mag-
Meter.aspx to your hard drive.
2. From the Flow Meter Tool, click on Update Flow Meter
rmware.
3. Click on Select rmware le…
4. Navigate to the location where you saved the
rmware le.
5. Select the new M5000 rmware le.
6. Click on Start.
7. The firmware update will delete all data logging files to free
space on the flash drive for the upload firmware file. You must
confirm the deletion (or interrupt it and download data logs).
8. The Flow Meter Tool starts uploading the firmware file to the flow
meter.
Installation Manual
Page 3August 2014
9. After the upload is finished, the M5000 is restarted to start the
firmware update on it.
During the update, the M5000 displays this
informational message.
10. When the update is complete, the M5000 displays the firmware
date.
11. You are prompted to reset the connected Flow Meter to nish
the rmware update. Click Yes.
12. After reset, the Flow Meter Tool shows the new
rmware version.
www.badgermeter.com
M-SERIES and ORION are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous
research, product improvements and enhancements, Badger Meter reserves the right to change product or system specications without notice, except to the extent an
outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved.
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400
México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882
Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0
Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503
Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411
Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01
Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-04 Parkway Parade | Singapore 449269 | +65-63464836
China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412 IOM-841-01-EN 53400-841
Control. Manage. Optimize.