Bangtang Network Technology Femometer FM-IVY-101 User manual

Product name: IVY Model: FM-IVY-101

Intended use 21
2Dos and Don’ts 3
3How to use 4
4Test result 6
5Product structure 8
6Legends 9
7List of accessories 9
8Product specifications 10
9Q&A 10
10Disclaimer
12
11
11Warranty
12Copyright statement 13
1313Certification
1414FCC warning
1615Quick Guide
Table of Contents
1

1 Intended use
This product is used for the qualitative detection of luteinizing
hormone in human urine. Luteinizing hormone is a type of
gonadotropins, LH for short and also known as interstitial cell-stimu-
lating hormone (LCSH). It is produced by the basophils in the
anterior pituitary, and interacts with mature follicles, leading to
ovulation and producing corpus luteum. It is a key hormone that
accelerates egg release and corpus luteum formation. Ovulation is
only initiated when its secretion is normal and reaches a certain
amount. Average women of childbearing age ovulate once a month.
Ovulation normally happens between 12 to 16 days before next
menstruation. The egg released can only survive for 12 to 30 hours.
Sperms can be alive in genital meatus for 2 to 3 days. There are
only a couple of hours that are crucial for conception. Therefore,
accurate forecasts of ovulation are essential to guide women who
are trying to conceive in choosing the best time for intercourse for
higher conception probability. They are also significant to guide
women who are on birth control to avoid intercourse during
ovulation.
Thank you for purchasing
For the safe use of this product, please read this User Manual first,
and keep it properly after reading so that you may access and
consult at any time. The warranty card is also included in the
package. Please do not lose it.
2

You can choose to use the urine of any of the three periods -
morning, afternoon, or evening.
The test strip in the bag should be used immediately after
unpacking to avoid failure caused by dampness.
Stop drinking water 2 hours before collecting the urine sample to
prevent it from being diluted.
There is a desiccant in the aluminum foil bag. Do not eat it.
Product expired may not be used.
The urine cup can be reused.
Test strips are disposable and cannot be reused.
Please discard the test strips in a non-recyclable bin after use.
This product is for in vitro diagnostic use only.
This product is an auxiliary diagnostic device only. It cannot
determine the actual amount of LH in a urine sample. The test
results cannot serve as a basis for diagnosis.
The test result will be displayed through the LED light. Once the
test is completed, the icon will be displayed for 30 seconds before
it goes out. If you want to check the result again, simply pull out
the test strip, or try to put the lid of Femometer IVY back on and
pull it out again. The result from your latest test will be shown.
Battery disposal must comply with the regulations of the national
government and environmental protection agencies.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
2 Dos and Don’ts
Any measurement done by this product is for personal reference
only. It is very dangerous for a patient to conduct self-diagnosis and
self-treatment based on measurements only. Please be sure to
follow your doctor’s instructions.
Warning
3

Step 1: Remove the battery cover. Install the button cell in the
direction as indicated. When you hear a beep, it indicates that the
battery has been inserted successfully. Put the battery cover back
in place.
3 How to use
Step 3: Remove the lid of the main body. When you hear a beep,
it indicates that Femometer IVY is on. Insert the test strip into the
main body in the direction as indicated. (Please make sure that the
test strip is inserted all the way to the bottom and the whole arrow
has disappeared.) When the light starts to flash,
it means the device is ready for the test.
Step 2: Collect your urine in the cup included in the package.
You can choose the urine from any of the three different time of
the day - morning, afternoon and evening.
CR2032
CR2032
4

3 How to use
Step 4: Collect your urine in the cup included in the package. Dip
the top of the test strip into the urine and hold it until you hear a
"beep" (at the same time, the status light starts fast flashing). Then
pull it out and put the test strip lid back on.
Step 5: Place the product on a flat surface. The LED light will be
flashing during the testing. Wait for about 6-10 minutes till you hear
three beeps which indicate that the test is completed. The test
result will be displayed via the LED light. If the light goes out after
some time, pulling out the test strip, or putting back & pulling out
the main body lid again will enable the last test result to show
again.
6-10min
4
5

4 Test result
Indicates a negative result with a low probability of
conception. Please test again after 12 hours. To
ensure the accuracy of the tests, please test every
day.
The measurement result will be displayed for 30 seconds.
Symbol “-”
Indicates a positive result in which the test line is
lighter than the control line. When it detects the rise
of Luteinizing Hormone for the first time, “+” will be
displayed, which indicates a high probability of
conception. Please test every 4-6 hours afterwards.
But don’t drink too much liquid before testing.
Symbol “+”
6
How to use Bluetooth:
1. Open the electronic device and APP.
2. Follow the APP prompts to bind the device.
3. After connecting, the data will be automatically synchronized via
Bluetooth afterwards.

4 Test result
Indicates a positive result where the test line is of the same color
as or darker than the control line. LH surge is detected. And you
have the highest probability of conception. Please keep testing
every 4-6 hours until it shows "+", which indicates that you have
ovulated.
Symbol “++”
7

Femometer IVY consists of the main body, Lid of the main body,
test strips, and battery cover.
Lid of the
main body
Main body
Test strip
cover
Test strips
LED display
5 Product structure
Battery cover
8

User manual Quick guide
Urine cup
6 Legends
7 List of accessories
Please confirm what’s in the package you have purchased. The
package contains a Femometer IVY, a battery (CR2032 button cell),
a user manual, a quick guide, a urine cup and 6 test strips. In case
Warning | It means that misuse may cause injury or death.
Don’ts | It means that it is strictly prohibited.
Battery
Test stripsMain body
C
R
2
0
3
2
9

Product name
IVY
Model
FM-IVY-101
Dimension
129mmX27mmX17mm
Weight
57g (Battery excluded)
Service life
3 years (Battery excluded)
Storage condition
Battery
1*CR2032 Battery
Operation condition
Temperature:10℃-40℃
RH: ≤85%
Pressure : 86-106kpa
Temperature:-25℃-55℃
RH: ≤95%
Pressure : 86-106kpa
8 Product specifications
1. Q: What should I do if I open the lid and have a long,
low-pitched sound?
A: The battery has run out. It is recommended to replace the battery.
9 Q&A
10

2. Q: Is the test strip inserted into the test long and flash red
signal?
A: It is not possible to test used test strips. It is recommended to
replace with a new test strip.
3. Q: The test is completed and the red light is on?
A: The test strip has failed and it is recommended to replace with a
new test strip.
4. Q: Why is the testing duration not always the same?
A: The duration of the test is related to the amount of urine taken and
the level of LH. But the test results will not be affected by the length of
the testing time.
9 Q&A
11
10 Disclaimer
This manual is written in accordance with available information and
contents are subject to change without notice. Hangzhou Bangtang
Network Technology Co., Ltd. has made the best effort to garantee
the manual’s accuracy and relability. However, the company does
not assume liability for loss or damage caused by omissions,
inaccuracies or typographical errors in this manual.
If there are discrepancies in this manual due to software upgrades,
instructions and function dictated by the software.

11 Warranty
Product model: Remark:
Purchase data: Point of sales:
Note
• 1-year warranty (from date of purchase) is included under proper
usage.
• Warranty doesn’t cover parts other than Earmo itself.
• Under these circumstances, repair will be charged.
• Warranty expired.
• Warranty card not shown to seller.
• Vague information on warranty card.
Warranty does not cover
• Product surface damage
• Battery
• Damages caused by improper using habit
• Improper inspection and maintenance
• Other irresistible reasons.
12

12 Copyright statement
13 Certificate
Hangzhou Bangtang Network Technology Co., Ltd. reserves all
rights, and retains the final right to interpret and revise this handbook
and the statements contained therein. Copy right of this manual
belongs to Hangzhou Bangtang Network Technology Co., Ltd.
Without prior written permission, no company or individual is allowed
to reproduce, copy or translate this manual or any information
contained therein.
Hangzhou Bangtang Network Technology Co., Ltd.
Floor 12, 92 Yueda Street, Binjiang District, Hangzhou, China
Distributor:Hangzhou Bangtang Network Technology Co., Ltd.
F12 No.92 Yueda Valley, Binjiang District, Hangzhou, 310058 China
13

Any Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and
(2) This device must accept any interference received, including
interference that may cause undesired operation.
RF warning for Portable device:
The device has been evaluated to meet general RF exposure
requirment. The device can be used in portable exposure condition
without restriction.
Note: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more
of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
14 FCC warning
14

15
Scan QRcode for e-version of the manual

15 Quick Guide
16
Please read carefully before use.
Search Femometer in the App Store or Google Play, then
download and install the Femometer App.
The package contains a brand new CR2030 battery, please
install it according to the following instruction.
Install the Battery
Open the App, sign up an account, enter the home page, and
then click the icon on the top left corner to pair the Femometer.
Pair the Femometer with the App
Download the Femometer App
Table of contents
Popular Personal Care Product manuals by other brands

Orliman
Orliman airyplant AP750P Use and maintenance instructions

Beurer
Beurer MP 55 Instructions for use

i-like Metaphysik
i-like Metaphysik sinus 25 operating instructions

Philips
Philips Sunmobile 4S HB 971/A Service manual

AMAZON COMMERCIAL
AMAZON COMMERCIAL B07ZDFG8QL manual

NPM
NPM ORON 56 instruction manual