Output Configuration
D1_Out: IO-Link, Push/pull
D2_Out: PNP
Output Ratings
100 mA maximum capability each output
Saturation: Less than 2 V
Off-State Leakage Current: Less than 50 µA PNP at 30 V (N.A. push/pull)
Remote Input
Allowable Input Voltage Range: 0 to Vcc
Active High (internal weak pulldown—sourcing current):
High State > Vcc – 1.5 V dc
Low State < Vcc – 5 V dc
Input Impedance > 10 kOhm
Measurement/Output Rate
Class 2 Laser Models: < 1 ms
Class 1 Laser Models (Fast): < 1 ms
Class 1 Laser Models (Std/Medium/Slow): < 2 ms
Minimum Window Size
LE250: 1 mm (0.039 inches)
LE550: 10 mm (0.39 inches)
Boresighting
LE250: 4 mm radius at 400 mm
LE550: 1 cm radius at 1 m
Maximum Torque
2 N·m (17.7 in-lbs)
Indicators
Power LED Indicator
Solid Green = Normal operation, power On and laser On
Flashing Green (1 Hz) = Power On and laser Off (laser enable mode)
Discrete Output LED Indicator
Solid Amber = Discrete Output is On
Off = Discrete Output is Off
Construction
Housing: die-cast zinc
Window: acrylic
Typical Beam Spot Size1
Distance (mm)
LE250 Models LE550 Models
100 250 400 100 550 1000
x 3.2 2.1 1.2 8.4 10.5 12.1
y 2.2 1.5 0.9 3.5 4.2 4.9
IO-Link Interface
Supports Smart Sensor Profile: Yes
Baud Rate: 38400 bps
Process Data Widths: 32 bits
IODD files: Provides all programming options of the display, plus additional
functionality
Ambient Light Immunity
Class 2 laser models: > 10,000 lux
Class 1 laser models: > 5,000 lux
Response Time
Class 1 Laser
Models Class 2 Laser
Models
Fast 22 ms 2 ms
Standard 10 ms 5 ms
Medium 30 ms 15 ms
Slow 100 ms 50 ms
Delay at Power Up
3 s
Repeatability
See Performance Curves
Temperature Effect
See Performance Curves
Environmental Rating
IEC IP67, NEMA 6
Operating Conditions
−20 °C to +55 °C (−4 °F to +131°F)
90% at +55 °C maximum relative humidity (non-condensing)
Storage Temperature
−30 °C to +65 °C (−22 °F to +149 °F)
Vibration/Mechanical Shock
All models meet Mil. Std. 202 G requirements method 201A. Also meets IEC
60947-5-2.
Application Note
For optimum performance, allow 10 minutes for the sensor to warm up
Certifications
Industrial
Control
Equipment
3TJJ
UL Environmental Rating: Type 1
Required Overcurrent Protection
WARNING: Electrical connections must
be made by qualified personnel in
accordance with local and national
electrical codes and regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via
Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Supply Wiring
(AWG) Required Overcurrent Protection
(Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
1Beam spot size is calculated as 1.6 times the D4σmeasured value
2Response time for lateral entry of object into measurement range < 5 ms
L-GAGE®LE250/550 IO-Link Laser Sensors
P/N 194204 Rev. B www.bannerengineering.com - Tel: +1-763-544-3164 7