BARIX annuncicom 100 User manual

ANNUNCICOM
100
Quick Install Guide
Version 2.0
IP Intercom, Public Address and Paging Device
Package contents
a Annuncicom 100
b Power supply
c RCA adapter for earphone
d Screw block terminals
Cable Set AUDIO (not included)
e Earphone
f RCA stereo cable
g Network cable
h Serial cable
Firmware
This device comes preloaded with standard firmware.
Alternative firmware can be downloaded from www.barix.com.
Support
For support please contact your local dealer or visit www.barix.com.
© Barix AG 3/2013, all rights reserved. All information is subject to change without notice. All mentioned trademarks belong
to their respective owners and are used for reference only. Barix, Exstreamer and SonicIP are trademarks of Barix AG, Switzerland,
and are registered in certain countries.

Rear view
I Inputs & Relay
Pin Description
1 Dry contact input 0 *
2 Dry contact input 1 *
3 Ground [G]
4 Relay open [NO]
5 Relay common **
6 Relay closed [NC]
* pull-up 4.7 KOhmto 5VDC ** Relay 50V 1A
J LAN status LEDs
Green LED for Link, yellow LED for Activity
K LAN port 10/100 (RJ45 Ethernet socket)
Pin Description
1 Tx +
2 Tx -
3 Rx +
4,5,7,8 Not connected
6 Rx -
L Power (8 Watt max)*
Pin Description
1 Ground [G]
2 +9..30VDC/12..24VAC
M Power (8 Watt max)*
Pin Description
ring Ground [G]
cent. +9..30VDC/12..24VAC
* L and M are connected internally so one can be used as an
output for other devices.
Front view
A Reset button
A brief press of the button will reset the device.
Holding the reset button pressed in for approximately
10 seconds will reset the device and restore the factory
default settings when the button is released.
B RS-232/485 serial port (DSub 9 pin male)
Pin Description
1 Not connected
2 Receive Data [RxD]
3 Transmit Data [TxD]
4 V+ 14.6V, 100mA max
5 Ground [GND]
6 RS-485 A
7 Ready to Send [RTS]
8 Clear to Send [CTS]
9 RS-485 B
C Green and red LEDs
For device status display
D EXT.
USB interface solely for flash memory sticks
(not supplied)
E Mic input Jack (Stereo mini Jack)
Pin Description
tip Microphone input
ring Bias Power (2.7 VDC)
end Ground [G]
F Line input (RCA socket)
G Line output (RCA socket)
(Earphone out using RCA adapter)
H Mic & Speaker
Pin Description
1 Microphone input
2 Bias Mic Power (2.7 VDC)
3,4 Ground [G]
5 Speaker + (4..32 Ω)
6 Speaker - (2W@4 Ω)
D
EBA C
H
I
J
K MLF G
96
1 5
1 2
18
6
1
61

1 Installation
STEP 1
Plug a standard (straight) network cable (g, not included)
into the network port (K) of the Annuncicom and the
other end into your hub or switch. You can also use a
crossover network cable (not included) for a direct
connection to your PC.
STEP 2
Plug the RCA adapter (c) into the RCA line output (G) and
an earphone (e, not included) into the adapter. Put the
earphone in your ear. Alternatively you can use a standard
mini jack headset or headphones.
STEP 3
Connect the Power supply (b) to the device (socket M)
and then to an appropriate electrical outlet.
STEP 4
i) The Annuncicom will now acquire an IP address and
announce it over the speaker and line output (if no DHCP
server is available this can take up to 5 minutes).
ii) If you did not connect any audio outputs in step 2,
either see the next page for the ARP command
procedure, or use the “Barix Discovery Tool” Java
application (download the latest version from
www.barix.com) on your computer (Windows, Mac
or Linux) and click the “Get” button to find out which
IP address the device has obtained (see picture at the
bottom of the page). Make sure that the Ethernet
address (MAC) matches your device (see label on the
bottom of the device).
Now that you know the IP address proceed to the next
section “Network configuration by web browser”.
If you were not able to obtain the device’s current
IP address with the previous steps see section
«Troubleshooting».
2 Network configuration
by web browser
Most Barix applictaions require no configuration but use
DHCP to configure network settings dynamically.
If you need to use static (fixed) network settings follow
steps 1 to 3, otherwise continue from step 4.
STEP 1
Open your web browser.
STEP 2
Enter the IP address that was announced by the Annuncicom
and press Enter. Example: 192.168.0.12 Click on the
Configuration button, then on Advances Settings/Network.
STEP 3
In order to make the application work the following parameters
must be set (check with your network administrator):
• static IP address (the default «0.0.0.0» sets automatic
discovery: BootP, DHCP) and netmask
If you your devices are connected via routers also:
• Gateway IP address
Hit the «Apply» button to save all changes. The device will
reboot with the configured IP address.
STEP 4
To complete the application setup, download the firmware
documentation from www.barix.com. Download the
product manual for additional information about the
hardware installation, technical and mechanical details
as well as instructions on updating or changing the loaded
application firmware.

3 Setting temporary IP address
using ARP command
This procedure will work only in a local network.
After this procedure the temporary IP will be active
only until restart/reboot. After a restart the procedure
has to be repeated.
STEP 1
Either use a network cable to link the Annuncicom and
the PC directly, or connect the Annuncicom to the PC
via your network switch and power the device. Make
sure that you have a valid static IP address configured on
your PC (e.g. 192.168.0.2)
STEP 2
Windows : For a command window. click on «Start», click
on «Run..», in the «Open» field type cmd , click on «OK».
OSX / Linux : Open a terminal window.
STEP 3
Please proceed to step 4 if you linked the PC directly to
the device in step 1. To ensure that you use a free IP
address (not already used by another device in the network)
please use the Ping command. To verify availability in
this example we assume the PC to have the IP address
«192.168.0.2» and want to check if «192.168.0.6» is free.
Typ e ping 192.168.0.6 and hit the «Enter» key. You
should get no reply which gives you reasonable assertion
that the «pinged» IP is available.
STEP 4
Look for the Annuncicom’s MAC address printed on a
label on the bottom of the device (12 hex digits, separated
by a hyphen every 2 digits). Type into the windows com-
mand window
arp -s 192.168.0.6 00-08-E1-00-B1-77
or on a OSX or Linux system type into the terminal
arp -s 192.168.0.6 00:08:E1:00:B1:77
and hit the «Enter» key (replace the digits according to your
devices MAC address). You must have administrative rights
to be able to do so (sudo on OSX / Linux).
STEP 5
Now we have to make the Annuncicom listen to the IP
address «192.168.0.6» using the Telnet command. To do so
type into the command window telnet 192.168.0.6 1
and hit the «Enter» key (the number «one» must be there
for this command to work correctly !!!). The Annuncicom
will immediately refuse the connection on port 1, but will
be available for browser access as long as the device stays
powered.
STEP 6
To check if the Annuncicom is responding you can use
the ping command again. To do so type ping 192.168.0.6
and hit the «Enter» key. If you do get a reply the IP address
192.168.0.6 can be used to access the Annuncicom using a
web browser. Please go back to section «2 Network configura-
tion by web browser» to configure a static IP address. If you do
get «request timed out» then please repeat step 5 carefully (you
most likely mistyped the telnet command) or repeat the entire
procedure. If the ARP method does not work for you, refer to
the user manual for further methods.
4 Troubleshooting
• If the status LEDs (C) stay dark check the power
cabling (installation step 3).
• Check if the green LINK LED (J) is lit, if it is not then
check your network cabling (network port K).
• If you have doubts about the current device settings
you can revert the device to its factory defaults by
pressing the Reset button (A) until the red status LED
(C) blinks rapidly (takes about 10 seconds). The device
will reboot once the button is released.
For information about our products, manuals, technical
documentation, latest firmware, support and access to
the user forum please visit www.barix.com.
Barix AG, Seefeldstrasse 303, CH-8008 Zürich
P+41 43 433 22 11
info@barix.com, www.barix.com
Other manuals for annuncicom 100
1
This manual suits for next models
1
Other BARIX Intercom System manuals
Popular Intercom System manuals by other brands

Westinghouse
Westinghouse WHI-4CUPG - Voice Activated Intercom owner's manual

Cabletech
Cabletech TF-01 Instruction booklet

PS Engineering
PS Engineering PM1000 II Operator and installation manual

Marmitek
Marmitek DP150 user manual

Philips
Philips WelcomeEye Connect 2 user manual

David Clark
David Clark 9800 Series installation manual