ANNUNCICOM 1000
Network intercom and PA
component for commercial,
industrial and security
applications
Quick Install Guide Version 1.0
ANNUNCICOM
Package content
a Annuncicom 1000
b Power supply
c Serial cable
d Screw block terminals (4 x 8 pin, 6 x 3 pin)
e Label stickers for screw block terminals
Front view
1 2 3
1 Reset button (Press this button shortly to reset the
device. If you press it until the red light flashes (about 5
seconds) the device will be reset to factory defaults.
2 Green and red LED for status display
3 Green LED (1...8) for I/O status display
Rear view
A B*C D E
F G*H I J K L M N
A Relay outputs 1..4 (1/2:R01, 3/4:R02, 5/6:R03,7/8:R04)
B Inputs 1..4 (1:IN1+,2:-, 3:IN2+, 4:-, 5:IN3+, 6:-, 7:IN4+, 8:-)
*WARNING: An input voltage on the “+” pin greater
than 5 VDC can destroy the device!
The “-“ pin is connected to the power supply “–“ pin!
C Left audio output (symmetric: cold:1, shield:2, hot:3)
Shield pin is connected to the power supply “–“ pin!
D Left audio input (symmetric: cold:1, shield:2, hot:3)
Shield pin is connected to the power supply “–“ pin!
E RS-485 bus (B:1, reference:2, A:3). The reference pin is
connected via 100 Ohm to the power supply “–“ pin!
F Relay outputs 5…8 (R05:1/2, R06:3/4, R07:5/6, R08:7/8)
G Inputs 5…8 & Fault Relay (1:IN1+, 2:-, 3:IN2+, 4:IN3+,
5:-, 6:IN4+, 7/8 Fault Relay [Normally Closed])
*WARNING: An input voltage on the “+” pin greater
than 5 VDC can destroy the device!
The “-“ pin is connected to the power supply “–“ pin!
H Right audio output (symmetric: cold:1, shield:2, hot:3)
Shield pin is connected to the power supply “–“ pin!
Rear view (continued)
I Right audio input or Microphone input (symmetric:
cold:1, shield:2, hot:3 / Mic. power configurable)
Shield pin is connected to the power supply “–“ pin!
J RS-232 serial port (DSub9 male)
K ETH1 RJ45 for LAN 10/100 Half/Full duplex
L ETH2 RJ45 (NOT supported)
M Power (1: +24..48 VDC, 2/3: power supply minus)
E Power (center: +24..48 VDC, ring: power supply minus)
Installation
STEP 1
Plug a standard (straight) network cable (not included) into
the network port (K) of the Annuncicom 1000 and the
other end into your hub or switch. You can also use a
crossover network cable (not included) for a direct
connection to your PC.
STEP 2
Connect at least the left output (C, &H for stereo) to the
amplifier or mixer input(s) and adjust the volume for
speaker(s) or a headphone. Get a pen and paper ready to
write down the IP address that will be announced in step 4.
STEP 3
Plug the power supply (b) into the power jack (E) of the
device and the other end into the power outlet of the wall.
STEP 4
The Annuncicom 1000 will now search for a DHCP server
to get an IP address and announce it over the audio
outputs. Example:192.168.0.12 (Voice: one nine two…)
Make sure you write this IP address down.
Your Annuncicom 1000 is now ready to start working.
We recommend, however, that you set a Static IP address.
See next pages on how to do this or download the user
manual from www.barix.com.
Troubleshooting:
If no DHCP server is found then our IPzator function will
search the network for a free IP address (this could take up
to 5 minutes).
If the IP address is not announced check if the green LED
(right LED on top of network port A) is lit. If it stays dark
check your network cabling. If the front LEDs (3) stay dark
check the power cabling (step 3).
If it still fails than revert the device to factory defaults by
pressing the Reset button (1) for about 5 seconds while the
Annuncicom is powered and repeat the above steps.
Network configuration by web browser
STEP 1
Open your web browser.
STEP 2
Enter the IP address of the Annuncicom 1000 and press
Enter. Example: 192.168.0.12
STEP 3
Click on the Configuration button.
STEP 4
Enter an IP address into the 4 IP address fields. At default it
is 0.0.0.0 for automatic discovery. Ask your network admin
before using the IP address announced by SonicIP.
STEP 5
In normal operating conditions leave the Netmask as is.
STEP 6
The Gateway, primary and alternative DNS IP addresses as
well as Sonic IP can be left at default for now.
STEP 7
Hit the Apply button to save all changes.
The Annuncicom 1000 will reboot with a Static IP address.
Please continue with section “Next steps” on last page.
Network configuration using supplied
serial cable
STEP 1
Open a Terminal program.
STEP 2
Go to the settings menu of the terminal program and
adjust the following settings:
Baud rate 9600 bit/sec, 8 Data Bits, no Parity, 1 Stop Bit
STEP 3
Unplug the power supply of the Annuncicom 1000.
STEP 4
Connect the supplied serial cable to your PC’s COM port
and to the serial port of the Annuncicom.
STEP 5
Keep the Reset button pushed and plug in the power
supply. Release the Reset button as soon as you see the
following screen:
STEP 6
Hit <s> to skip network discovery if not connected to a
network and the following screen appears:
STEP 7
Hit <s> to get to the Annuncicom setup.
STEP 8
Hit <enter> to enter the Annuncicom setup mode.
STEP 9
Type in <0> and hit <enter> to enter the Network
configuration. Enter all requested values:
STEP 10
Type in <9> and hit <enter> to save the Network
configuration.
Please continue with section “Next steps”.
Network configuration using telnet
STEP 1
Unplug the power supply of the Annuncicom 1000.
STEP 2
Keep the Reset button pushed and plug in the power
supply. Release the Reset button after 5 seconds.
STEP 3
Run a command session. Type at the command prompt
“telnet” followed () with the IP address announced by Sonic
IP on port 9999.
Example: telnet 192.168.0.12 9999
You will see the following screen:
Hit <enter> to access the Exstreamer in the setup mode.
STEP 4
Type in <0> and hit <enter> to enter the Network
configuration. Enter all requested values.
STEP 5
Type in <9> and hit <enter> to save the Network
configuration.
Next steps
STEP 1
Download the user manual from www.barix.com.
STEP 2
Read the manual to configure the functionality of the
Annuncicom 1000.
STEP 3
Check the section “Updating the device”.
STEP 4
Check out the Barix user forum on www.barix.com for
additional information.
Support
For support please contact your local dealer or visit
www.barix.com.
© Barix AG 9/2007, all rights reserved.
All information is subject to change without notice.
All mentioned trademarks belong to their respective
owners and are used for reference only.
Barix, Annuncicom, SonicIP and IPzator are trademarks of
Barix AG, Switzerland, and are registered in certain
countries.
For information about our products, manuals, technical
documentations and latest version of firmware please visit
www.barix.com.
Barix AG
Seefeldstrasse 303
8008 Zürich
SWITZERLAND
www.barix.com

Other BARIX Intercom System manuals

BARIX Annuncicom IC User manual

BARIX

BARIX Annuncicom IC User manual

BARIX Annuncicom PS Touch User manual

BARIX

BARIX Annuncicom PS Touch User manual

BARIX annuncicom 100 User manual

BARIX

BARIX annuncicom 100 User manual

BARIX Annuncicom User manual

BARIX

BARIX Annuncicom User manual

BARIX Annuncicom 60 User manual

BARIX

BARIX Annuncicom 60 User manual

BARIX annuncicom 100 User manual

BARIX

BARIX annuncicom 100 User manual

BARIX Annuncicom 155 User manual

BARIX

BARIX Annuncicom 155 User manual

Popular Intercom System manuals by other brands

quhwa QH-1085 user manual

quhwa

quhwa QH-1085 user manual

Menvier Security SD1 operating instructions

Menvier Security

Menvier Security SD1 operating instructions

RTS TR-1800 user manual

RTS

RTS TR-1800 user manual

Bouyer PC 1106 quick start guide

Bouyer

Bouyer PC 1106 quick start guide

Konx KX7001 user manual

Konx

Konx KX7001 user manual

golmar PE-90-MS/6 quick start guide

golmar

golmar PE-90-MS/6 quick start guide

Cheer GS-WVD708 user manual

Cheer

Cheer GS-WVD708 user manual

Cardo Systems Freecom 4 Plus user manual

Cardo Systems

Cardo Systems Freecom 4 Plus user manual

Comelit 8461X Technical manual

Comelit

Comelit 8461X Technical manual

Eyevision EV-DMR18S user manual

Eyevision

Eyevision EV-DMR18S user manual

Häfele 959.23.040 quick start guide

Häfele

Häfele 959.23.040 quick start guide

SSS Siedle SIC 3000-01 installation instructions

SSS Siedle

SSS Siedle SIC 3000-01 installation instructions

FARFISA INTERCOMS myLogic PL72 manual

FARFISA INTERCOMS

FARFISA INTERCOMS myLogic PL72 manual

Koch TC40/STA user manual

Koch

Koch TC40/STA user manual

ECA COMMUNICATOR GSM18V82 Installation & owner's manual

ECA

ECA COMMUNICATOR GSM18V82 Installation & owner's manual

Grandstream Networks GDS3710 Configuration guide

Grandstream Networks

Grandstream Networks GDS3710 Configuration guide

SSS Siedle BVI 750-0 Installation & programming

SSS Siedle

SSS Siedle BVI 750-0 Installation & programming

golmar 50124319 instruction manual

golmar

golmar 50124319 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.