Barracuda PUMPS 92000 User manual

SKU: 691-1615
Model # 92000
UNIVERSAL TETHERED FLOAT SWITCH
BA92000 Manual Rev: 6-18
Inventory
1. Universal tethered oat switch (1)
2. Stainless Steel Hose Clamp (1)
3. Mounng Clamp (1)
4. Hardware Pack (2 screws, 2 washers
& 1 stainless steel cord clamp)
LIMITED WARRANTY
Barracuda Pumps warrants the products specied in this warranty to be free from defects in material or workmanship for one (1) year from date of purchase. During the me period and
subject to the terms and condions, the Barracuda Pumps will repair or replace to the original user or consumer any poron of this product which proves to be defecve due to materials
or workmanship. At all mes the Barracuda Pumps shall have and possess the sole right and opon to determine whether to repair or replace defecve equipment, parts, or components.
The Barracuda Pumps has the opon to inspect any product returned under warranty to conrm that the warranty applies before repair or replacement under warranty is approved. This
warranty sets forth the Barracuda Pumps sole obligaon and purchaser’s exclusive remedy for defecve product. Return defecve product to the place of purchase for warranty
consideraon.
WARRANTY PERIOD - PRODUCTS:
If, within the duraon of product use by the original user, this product proves to be defecve due to materials or workmanship, the product shall be repaired or replaced at the Barracuda
Pumps opon, subject to the terms and condions set forth in this warranty statement. Proof of purchase is required for warranty consideraon. In the absence of suitable proof of the
purchase date, the eecve period of this warranty is 12 months from the product’s date of manufacture.
LABOR, ETC. COSTS:
The Barracuda Pumps shall IN NO EVENT be responsible or liable for the cost of eld labor or other charges incurred by any customer in removing and/or axing any product, part, or
component thereof.
PRODUCT IMPROVEMENTS:
The Barracuda Pumps reserves the right to change or improve its products or any porons thereof without being obligated to provide such a change or improvement for units sold and/or
shipped prior to such change or improvement.
GENERAL TERMS AND CONDITIONS:
This warranty shall not apply to damage due to acts of God, normal wear and tear, normal maintenance services and the parts used in connecon with such service, lightning or condions
beyond the control of the Barracuda Pumps, nor shall it apply to products which, in the sole judgment of the Barracuda Pumps, have been subject to negligence, abuse, accident,
misapplicaon, tampering, alteraon; nor due to improper installaon, operaon, maintenance or storage; nor to excess of recommended maximums as set forth in the instrucons.
Warranty will be VOID if any of the following condions are found:
1. Product is used for purposes other than those for which it was designed and manufactured
2. Product not installed in accordance with applicable codes, ordinances, and good trade pracces
3. Product connected to voltage other than indicated on nameplate or labels
DISCLAIMER:
Any oral statements about the product made by the seller, the Barracuda Pumps, the representaves, or any other pares do not constute warranes, shall not be relied upon by the
user, and are not part of the contract for sale. Seller’s and the Barracuda Pumpss only obligaon, and buyer’s only remedy, shall be the replacement and/or repair by the Barracuda Pumps
of the product as described above. NEITHER SELLER NOR THE BARRACUDA PUMPS SHALL BE LIABLE FOR ANY INJURY, LOSS OR DAMAGE, DIRECT, INCIDENTAL OR CONSEQUENTIAL
(INCLUDING, BUT NOT LIMITED TO, INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR LOST PROFITS, LOST SALES, INJURY TO PERSON OR PROPERTY, OR ANY OTHER INCIDENTAL OR
CONSEQUENTIAL LOSS), ARISING OUT OF THE USE OR THE INABILITY TO USE THE PRODUCT, AND THE USER AGREES THAT NO OTHER REMEDY SHALL BE AVAILABLE TO IT. Before using, the
user shall determine the suitability of the product for his/her intended use, and user assumes all risk and liability whatsoever in connecon therewith.
THE WARRANTY AND REMEDY DESCRIBED IN THIS LIMITED WARRANTY IS AN EXCLUSIVE WARRANTY AND REMEDY AND IS IN LIEU OF ANY OTHER WARRANTY OR REMEDY,
EXPRESSED OR IMPLIED, WHICH OTHER WARRANTIES AND REMEDIES ARE HEREBY EXPRESSLY EXCLUDED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, TO THE EXTENT EITHER APPLIES TO A PRODUCT SHALL BE LIMITED IN DURATION TO THE PERIODS OF THE EXPRESSED
WARRANTIES GIVEN ABOVE.
Some states and countries do not allow the exclusion or limitaons on how long an implied warranty lasts or the exclusion or limitaon of incidental or consequenal damages, so the
above exclusion or limitaons may not apply to you. This warranty gives you specic legal rights, and you may also have other rights which vary from state to state.
Customer Support
800-495-9278
barracudapumps.com

SKU: 691-1615
UNIVERSAL TETHERED FLOAT SWITCH
Risk of electrical shock. Can burn or kill. To reduce risk of electrical shock, disconnect the power supply before replacing switch. Make
sure switch is connected only to a properly grounded grounding type receptacle.
Short circuit electrical hazard. An incorrect connection may cause electric shock, or burn out the pump motor, resulting in property
damage or personal injury. Make sure all connections are correct before plugging the switch into the outlet.
The outlet voltage and pump voltage must match. Ensure voltage is correct before installing switch. The electrical outlet must be
installed outside the pump basin.
Risk of flooding. It is recommended to operate the pump through two or three complete cycles to ensure proper liquid level control.
Installation and Operating Instructions
1. Determine the required tether length/pumping range for your
installaon using the dimensions in the Tether Length Chart.
Refer to Figure 2.
2. Aach the oat switch cable to the pump discharge pipe using
the plasc mounng clamp and stainless hose clamp (see
Figure 1). NOTE: Do not install the cord under the hose clamp.
3. Locate the clamp at the desired acvaon level and secure to
the discharge pipe.
4. Make sure the oat operates freely without contacng the
sides of the basin.
5. Secure remaining cord to the discharge pipe to avoid possible
obstrucon with the oat switch operaon.
6. Plug the piggyback plug of the oat switch into a grounded
outlet, then plug the pump into the piggyback plug. Refer to
Figure 3.
7. Check for proper operaon by lling the basin with water and
observing the oat switch through at least two complete
cycles. Make sure the pump operates at the desired levels.
Make any necessary adjustments at this me.
Installation & Operating Instructions For
Barracuda Brand Pumps
1. Remove the old oat switch from the pump by removing the screw and
cord clamp.
2. Determine the required tether length/pumping range for your installaon
following the dimensions in the Tether Length Chart or measure the tether
length from the old switch.
3. Aach the stainless steel cord clamp to the new oat switch cord at the
desired tether length.
4. Aach clamp to the pump using the appropriate screw & washer. Refer to
Figure 4.
5. Plug the piggyback plug of the oat switch into a grounded outlet, then
plug the pump into the piggyback plug. Refer to Figure 3.
6. Check for proper operaon by lling the basin with water and observing
the oat switch through at least two complete cycles. Make sure the pump
operates at the desired levels. Make any necessary adjustments at this
me.
* Pump Sold Separately
Aach the oat
switch to the top
of the pump .
Before ghtening
adjust tether
length. Pump
Sold
Separately
Switch
Tether Length Chart
Tether Length 3.5" 6" 9" 12" 15" 18" 22"
Pumping Range 8" 11" 15" 21" 28" 31" 36"
Figure 2
Figure 3
Plug Pump
in here
To Outlet
Figure 1
Figure 4
Safety Guidelines
Washer
Screw
Cord Clamp
Table of contents
Popular Switch manuals by other brands

ATEN
ATEN VS481 user manual

UWT
UWT Vibranivo VN 4000 Series Technical Information/Instruction manual

Crestron
Crestron CLCI-1SW2EX-W installation guide

Eaton
Eaton CurrentWatch ECSTD Series Instruction leaflet

JSVER
JSVER JS-HB3111 user manual

HP
HP Procurve Series 4100GL Installation and getting started guide

Compaq
Compaq 158222-B21 - StorageWorks Fibre Channel SAN Switch... release note

Extreme Networks
Extreme Networks Summit Summit1i Hardware installation guide

Trust
Trust SMART Home START-LINE RECEIVER AWS-3500 Important information

Eaton
Eaton Disconnect Switches Product guide

Emerson
Emerson Rosemount 2120 Reference manual

steute
steute Ex ES Mounting and wiring instructions