SICK TBS User manual

OPERATING INSTRUCTIONS
TBS
Temperature Switch
Temperaturschalter
Operating instructions
Betriebsanleitung

GB
D
Prior to starting any work, read the operating instructions!
Keep for later use!
Declarations of conformity can be found online at www.sick.com.
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Konformitätserklärungen nden Sie online unter www.sick.de.
Operating instructions model TBS Page 4 - 29
Betriebsanleitung Typ TBS Seite 30 - 55

8014826/19ZH/2020-12-01 © SICK AG • Germany • All rights reserved • Subject to change without notice 3
Operating Instructions TBS
ContentsContents
Contents Page 4-29 GB
1. General information 4
2. Safety 6
3. Specications 9
4. Design and function 15
5. Transport, packaging and storage 16
6. Commissioning, operation 16
7. Maintenance and cleaning 26
8. Faults 27
9. Dismounting, return and disposal 29
Inhalt Seiten 30-55 DE
1. Allgemeines 30
2. Sicherheit 32
3. Technische Daten 35
4. Aufbau und Funktion 41
5. Transport, Verpackung und Lagerung 42
6. Inbetriebnahme, Betrieb 42
7. Wartung und Reinigung 52
8. Störungen 53
9. Demontage, Rücksendung und Entsorgung 55

4 © SICK AG • Germany • All rights reserved • Subject to change without notice 8014826/19ZH/2020-12-01
Operating Instructions TBS
1. General information
The temperature switch described in the operating instructions has been designed and manufactured using
state-of-the-art technology. All components are subject to stringent quality and environmental criteria during
production. Our management systems are certied to ISO 9001 and ISO 14001.
These operating instructions contain important information on handling the instrument. Working safely
requires that all safety instructions and work instructions are observed.
Observe the relevant local accident prevention regulations and general safety regulations for the
instrument's range of use.
The operating instructions are part of the product and must be kept in the immediate vicinity of the instru-
ment and readily accessible to skilled personnel at any time.
Skilled personnel must have carefully read and understood the operating instructions prior to beginning any
work.
The manufacturer's liability is void in the case of any damage caused by using the product contrary to its intended
use, non-compliance with these operating instructions, assignment of insufciently qualied skilled personnel or
unauthorised modications to the instrument.
The general terms and conditions contained in the sales documentation shall apply.
Subject to technical modications.
Further information:
- Internet address: www.sick.com
- Relevant product information: 8014742
1. General information

8014826/19ZH/2020-12-01 © SICK AG • Germany • All rights reserved • Subject to change without notice 5
Operating Instructions TBS
1. General information
The temperature switch described in the operating instructions has been designed and manufactured using
state-of-the-art technology. All components are subject to stringent quality and environmental criteria during
production. Our management systems are certied to ISO 9001 and ISO 14001.
These operating instructions contain important information on handling the instrument. Working safely
requires that all safety instructions and work instructions are observed.
Observe the relevant local accident prevention regulations and general safety regulations for the
instrument's range of use.
The operating instructions are part of the product and must be kept in the immediate vicinity of the instru-
ment and readily accessible to skilled personnel at any time.
Skilled personnel must have carefully read and understood the operating instructions prior to beginning any
work.
The manufacturer's liability is void in the case of any damage caused by using the product contrary to its intended
use, non-compliance with these operating instructions, assignment of insufciently qualied skilled personnel or
unauthorised modications to the instrument.
The general terms and conditions contained in the sales documentation shall apply.
Subject to technical modications.
Further information:
- Internet address: www.sick.com
- Relevant product information: 8014742
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious injury or death, if not
avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries or damage to
equipment or the environment, if not avoided.
Information
… points out useful tips, recommendations and information for efcient and trouble-free
operation.
CAUTION!
... indicates a potentially dangerous situation that can result in burns, caused by hot surfaces
or liquids, if not avoided.
Abbreviations
L+Positive power terminal
MNegative power terminal
QAAnalogue output
C/Q1:Switching output 1
For variants with IO-Link: IO-Link communication/switching output 1
Q2Switch point 2
SP1:Switching point 1
SP2: Switching point 2
MBA Start of measuring range
MBE End of measuring range
1. General information

6 © SICK AG • Germany • All rights reserved • Subject to change without notice 8014826/19ZH/2020-12-01
Operating Instructions TBS
2. Safety
WARNING!
Before installation, commissioning and operation, ensure that the appropriate temperature
switch has been selected in terms of measuring range, design and specic measuring
conditions.
Non-observance can result in serious injury and/or damage to the equipment.
WARNING!
Observe the working conditions in accordance with chapter 3 „Specications".
Further important safety instructions can be found in the individual chapters of these
operating instructions.
2.1 Intended use
The temperature switch is used to convert temperature into an electrical signal indoors and outdoors.
The instrument has been designed and built solely for the intended use described here, and may only be
used accordingly.
The technical specications contained in these operating instructions must be observed. Improper handling
or operation of the temperature switch outside of its technical specications requires the instrument to be
taken out of service immediately and inspected by an authorized SICK service engineer.
The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use.
2. Safety

8014826/19ZH/2020-12-01 © SICK AG • Germany • All rights reserved • Subject to change without notice 7
Operating Instructions TBS
2.2 Personnel qualication
WARNING!
Risk of injury should qualication be insufcient!
Improper handling can result in considerable injury and damage to equipment.
The activities described in these operating instructions may only be carried out by skilled
personnel who have the qualications described below.
Skilled personnel
Skilled personnel are understood to be personnel who, based on their technical training, knowledge of
measurement and control technology and on their experience and knowledge of country-specic regulations,
current standards and directives, are capable of carrying out the work described and independently recogni-
zing potential hazards.
Special operating conditions require further appropriate knowledge, e.g. of aggressive media.
2.3 Special hazards
WARNING!
For hazardous media such as oxygen, acetylene, ammable or toxic gases or liquids,
and refrigeration plants, compressors, etc., in addition to all standard regulations, the
appropriate existing codes or regulations must also be followed.
WARNING!
Residual media in the dismounted temperature switch can result in a risk to persons, the
environment and equipment.
Take sufcient precautionary measures.
2. Safety

8 © SICK AG • Germany • All rights reserved • Subject to change without notice 8014826/19ZH/2020-12-01
Operating Instructions TBS
2.4 Labelling / Safety marks
Product label
If the serial number becomes illegible (e.g. due to mechanical damage or overpainting), traceability will no
longer be possible.
Explanation of symbols
General danger symbol
CE, Communauté Européenne
Instruments bearing this mark comply with the relevant European directives.
Electrical connection
Analog output signal
Supply voltage
Serial number
Part number
Temperature range
Max. process pressure at room temperature
2. Safety

8014826/19ZH/2020-12-01 © SICK AG • Germany • All rights reserved • Subject to change without notice 9
Operating Instructions TBS
3. Specications
Features
Measuring range –20 °C ... + 80 °C (–20 °C ... + 120 °C optional)
Sensor element Pt1000, 2-wire, class A according to IEC 60751
Output signals 2x PNP
1 x PNP + 4...20 mA
1 x PNP + 0...10 V
2 x PNP + 4...20 mA
2 x PNP + 0...10 V
2 x NPN
1 x NPN + 4...20 mA
1 x NPN + 0...10 V
2 x NPN + 4...20 mA
2 x NPN + 0...10 V
IO-Link, revision 1.1 (option) (IO-Link is optionally available for all output signals. With the IO-Link option,
switching output SP1 is always PNP.)
Switching points Type: transistor switching output PNP or NPN
Quantity: 1 or 2
Function: normally open / normally closed; windows- and hysteresis function freely adjustable
Contact rating: supply voltage L+ - 1 V [V DC]
Max. switching current: without IO-Link 250 mA /with IO-Link SP1 max. 100 mA, SP2max. 250 mA
Switching delay: 0 ... 50 s (adjustable)
Individually adjustable via control buttons
Setting accuracy: 0.1 °C
Temperature offset ± 3 °C
Scaling of temperature
range
Zero: max. +25 % of span
Full scale: max. -25 % of span
Display 14-segment LED, blue, 4-digits, height 9 mm
Display electronically turnable by 180°
Update: 200 ms
Rotatable housing Display against housing with electrical connection: 330°
Housing against process connection: 320°
3. Specications

10 © SICK AG • Germany • All rights reserved • Subject to change without notice 8014826/19ZH/2020-12-01
Operating Instructions TBS
3. Specications
Performance
Accuracy of sensor element ≤ ± (0.15 °C + 0.002 |t|) 1)
Accuracy of switching output ≤ ± 0.8 % of span
Display accuracy ≤ ± 0.8 % of span ± 1 digit
Accuracy of optional analog output ≤ ± 0.5 % of span
Response time t50 ≤ 5 s
Response time t90 ≤ 10 s
1) |t| is the absolute value of the temperature in °C
2) Depending on sensor conguration, according to IEC 60751
Mechanics/electronics
Process connection G 1/4 A according to DIN 3852-E
G 1/2 A according to DIN 3852-E
Compression tting, G 1/2 A (for measuring range –20 °C ... + 120 °C)
Compression tting, G 1/4 A (for measuring range –20 °C ... + 120 °C)
1/4’’ NPT
1/2’’ NPT
Insertion lengths/diameter of probe 25 mm / 6 mm (not suitable for measuring range –20 °C ... + 120 °C)
50 mm / 6 mm (not suitable for measuring range –20 °C ... + 120 °C)
100 mm / 6 mm
150 mm / 6 mm
250 mm / 6 mm
350 mm / 6 mm
Wetted parts Stainless steel 1.4571 (AISI 316Ti)
Maximum process pressure 1) 150 bar
Compression tting mx. 50 bar, at 120 °C
Housing material Lower body: stainless steel 1.4301 (AISI 304)
Plastic head: PC + ABS
Buttons: TPE-E
Display window: PC
Enclosure rating 2) IP 65 and IP 67
Maximum ohmic load RA< 0.5 kΩ for output signal 4 mA ... 20 mA
> 10 kΩ for output signal 0 V ... 10 V
≤ 100 kΩ (switching outputs)
Table of contents
Languages:
Other SICK Switch manuals

SICK
SICK MLP1 User manual

SICK
SICK T4000 Direct Unicode User manual

SICK
SICK RE1 User manual

SICK
SICK PBS Series User manual

SICK
SICK ES21 M12 contact User manual

SICK
SICK i10P User manual

SICK
SICK IN4000 Standard User manual

SICK
SICK LBV 311-NAMUR User manual

SICK
SICK i16S User manual

SICK
SICK i12S User manual