Baxi uSense User manual

1
Give your customers
Installation guide

2
1 Compatibility
3 Before you start
Warning: High Voltage wiring must only be installed
and worked on by a suitably qualified person.

3
Warning: High Voltage wiring must only be installed
and worked on by a suitably qualified person.

4
Room unit package:
Gateway package:
1
1 2
3
4 5
2
3
4

5
Positioning the uSense:
The room unit must be positioned taking into
account the following factors:
•
Prior to installation make sure to:
1. Isolate the power to the heating and control
system and make safe (remove or lock o fuse)
2. Check that the power has been isolated
using suitable test equipment.
Wear appropriate Personal Protection Equipment
e.g. protective gloves, safety footwear etc.
Warning: High Voltage wiring must
only be installed and worked on by
a suitably qualified person.
1.5 m

6
The gateway
Incorrect wiring will result in damage to the
gateway, room unit and boiler which will invalidate the warranty.
Fix the gateway in position

7
Run power to the gateway
must not
must
24V
OT ON/OFFR-BUS

8
(See next page if using OpenTherm)
To connect using the ON/OFF terminals
ON
OFF
Connect the system control wiring
to the gateway
Read in conjunction with the boiler
installation and service manual
ON/OFF
OT
R-BUS are for
These components are low
voltage - 230V will damage
the room unit and gateway.
132
143
1: 24V Power supply
2: OT controlled boiler
3: Room Unit
1: 24V Power supply
3: Room Unit
4: ON/OFF controlled boiler
OpenTherm
ON / OFF
1
OT
ON OFF

9
To connect using the OT terminals
OT
Do not connect 230V to these
terminals or it will damage the
gateway
132
143
1: 24V Power supply
2: OT controlled boiler
3: Room Unit
1: 24V Power supply
3: Room Unit
4: ON/OFF controlled boiler
OpenTherm
ON / OFF
1
OT
ON OFF

10
To connect the gateway to the uSense
using the R-BUS terminals
continued opposite

11
R-BUS
The connection between the room
unit and gateway is low voltage,
230V will damage the room unit
and gateway!

12
Set up the uSense room unit
Before turning on the power to the gateway, room unit
and heating system, preliminary electrical tests
should be carried out.

13
The uSense room unit will override the hot water temperature controls
on your combi boiler (OpenTherm only).

14
Connecting to an outdoor sensor
ONLY
CANNOT
Remember to re-enter this code to disable
installer access when you nish adjusting the heating curve

15
Dimensions
Power supply
Electrical connection
Ambient conditions
uSense room unit

16
uSense room unit
Technical data

17
Compliant with standards:
ErP Fiche Information On modulating
boiler
On modulating boiler,
with outdoor sensor
On On/Off
boiler
Class

18
Temperature
Gateway

19
The LED on the gateway indicates the following modes and faults:

For tech support
Opening hours
baxi.co.uk
Baxi
e&oe
Warranty registration
Other manuals for uSense
4
Table of contents
Other Baxi Thermostat manuals

Baxi
Baxi uSense 2 User manual

Baxi
Baxi uSense User manual

Baxi
Baxi 720644701 Assembly Instructions

Baxi
Baxi uSense User manual

Baxi
Baxi TXW1AC Operating manual

Baxi
Baxi 720030501 Manual

Baxi
Baxi RD-1200 User manual

Baxi
Baxi 5117391 Assembly Instructions

Baxi
Baxi uSense User manual

Baxi
Baxi uSense User manual
Popular Thermostat manuals by other brands

Fantini Cosmi
Fantini Cosmi Intellicomfort CH180 manual

Silvercrest
Silvercrest RT2000 operating manual

Pro 1 IAQ
Pro 1 IAQ T631W-2 installation manual

Silvercrest
Silvercrest RT2000 Operating and safety instructions

oneConcept
oneConcept 10027881 manual

Pro 1 IAQ
Pro 1 IAQ TRUE COMFORT IIII installation manual