12 13
The DC protector turns to “OFF” automatically
when electric device being connected to the
generator is operating and current above the
rated flows. To use this equipment again, turn
on DC protector by pressing its button to “ON”.
1. “ON” Direct current is output.
2. “OFF” Direct current is not output.
Ground (Earth) terminal (1) connects the earth
line for prevention of electric shock. When the
electric device is earthed, always the generator
must be earthed.
The overload indicator light comes on when
an overload of a connected electrical device
is detected, the inverter control unit overheats,
or the AC output voltage rises. Then, the AC
protector will trip, stopping power generation
in order to protect the generator and any
connected electric devices. The AC pilot light
(Green) will go off and the overload indicator
light (Red) will stay on, but the engine will not
stop running. When the overload indicator
light comes on and power generation stops,
proceed as follows:
1. Turn off any connected electric devices and
stop the engine.
2. Reduce the total wattage of connected
electric devices within the rated output.
3. Check for blockages in the cooling air Inlet
and around the control unit. If any blockages
are found, remove them.
4. After checking, restart the engine.
TIP: The overload indicator light may come on
for a few seconds at first when using electric
devices that require a large starting current,
such as a compressor or a submergible pump.
However, this is not a malfunction.
The AC pilot light comes on when the engine
starts and produces power.
DC PROTECTOR
GROUND (EARTH) TERMINAL
OVERLOAD INDICATOR LIGHT (RED)
AC PILOT LIGHT (GREEN)
NOTICE
• Reduce the load of the connected electric device below the speci-
fied rated output of the generator if the DC protector turns off. If the
DC protector turns off again, stop using the device immediately and
consult a franchised dealer.
This is the terminal for connecting special
cables for parallel running of two generator.
The parallel running requires two generator
and the special cables. (The rated output in
parallel running is 6.0Kva and the rated current
is 60A/100V;50A/120V;26A/230V.)
The handing, operation procedure and the
notes on usage are described in the PARALLEL
RUNNING KIT OWNER’S MANUAL included
in the Parallel.
During the operation and idle period of
machine, brake timely and switch to “STOP”.
In case of the machine is required to be moved,
switch the brake to “RUN”.
PARALLEL OPERATION OUTLETS
BRAKE
CONTROL FUNCTION CONTROL FUNCTION