Programming
User codes (Monitor Bit codes)- Every room station
must have an ID, set through the bit codes (listed right).
Bits 1-5 are used to congure the room ID;
Bit-6 is the line-terminal switch, at the
LAST monitor to ON, otherwise set OFF.
Bit-7 is to turn the ringtone at the door station
On/Off.
You can have a max of 3 monitors per button/code.
externaL caMera - Connect with CN5 at the outdoor
panel, at a room monitor, press and hold Alarm until it
beeps, then press Monitor twice. Press Alarm to save
and exit.
To DISABLE an extra camera, press and hold
Alarm until it beeps, press Monitor once. Press Alarm
to save and exit.
Mt-2-4 - The switch on the LAST distributor in your
chain must be set to ON.
rooM-to-rooM caLLing - Intra-calling is available to
place a voice call with one other connected monitor.
To enable, you must rst set the 2-digit dial number
of the monitor to call. Press and hold Unlock until you
hear a long beep, press Monitor 1-9 times to assign that
number, press Unlock to conrm.
Example - Monitor 4 wishes to call monitor 9:
[@ Monitor 4, set dial # to 09] HOLD Unlock (Beep) -
Unlock x1 (assigns 0) - Monitor x 9 (assigns 9) - Unlock
(enter/conrm)
RF Reader
To program your fobs, swipe the master card included with your system, swipe the cards you wish
to activate, then re-swipe your master card to complete. We recommended taking inventory of all
key-fob ID #’s before programming, in case they’re lost or stolen. You can de-program individual
fobs using the available remote accessory. (Model: BE-RKC)
4