Rev 1 Copyright © 2021 by BECCA Inc. All Rights Reserved. BECCA 17.5 Gal Recycler Operator’s Guide Poster
6. Push the Start button. The cycle is now initiated. The system
display will show:
Set Temperature Current Temperature Remaining Time
7. We recommend not opening the unit after the cycle is completed for 1 –
3 ½ Hours or the Temperature is below 150 °F (Depends on
temperature, time, and the amount of solid waste). This allows the unit
to cool down.
8. The resulting ‘Still Bottom’ will range in
consistency from slurry to a marshmallow. All
of this is again dependent on the types of
solvents, type of paint, and the painter’s waste
levels and Recycler settings (Time &
Temperature).
9. Dispose of the ‘Still Bottom’ in an approved
Hazardous Waste container and assure proper
labeling.
10. You are now ready for the next cycle of the process.
3) Troubleshooting
1. Error Code “CHK COND SENSOR” – Condenser thermocouple is disconnected or defective. See “Instruction Manual”
2. Error Code “CHK TANK SENSOR” – Tank thermocouple is disconnected or defective. See “Instruction Manual”
3. Error Code “CHECK HEATER” – Appears 10 min after the cycle has started if the temperature of the tank did not
increase by 20°F or more. See “Instruction Manual”
4. Error Code “OUTLET TOO HOT” – The temperature of the clean solvent going out of the condenser exceeds 110°F for
more than 30 seconds. See “Instruction Manual”
5. Weak Solvent
-This is from the Cleaning process causing evaporation of “Acetone”. Add “Acetone” – typical solvent used in
solvent formulations that starts to evaporate at 80ºF and Boils at 130ºF.
-Water in the solvent –This will weaken the solvent potency.
4) Maintenance
1. Each Use - Replace Recycler Bag. Use only BECCA Recycler Bags to
assure performance 617017- 25 (25 PK), 617017- 50 (50 PK)
or 617017-100 (100 PK)
- Remove any contaminants from the bottom of the Boiler
2. Each day - Wipe-down the unit with solvent. The paint and decals
are solvent resistant.
- Remove any contaminants from the bottom of the Boiler
3. Semi- Annually - Blow off condenser (externally) to
remove dust and dirt
- Replace BECCA Protect™ Maintenance Coating (831004)
- Review Ground Clamp (823079K)
4. Annually - Replace Seal (171835)
- Blow out Condenser (internally)
- Review & Replace any illegible or damaged Decals
For assistance or service Phone or Fax:
Tel: (800) 655-5649 Fax: (800) 655-5684