Rev 1 Copyright © 2021 by BECCA Inc. All Rights Reserved. BECCA 55 Gal Recycler Operator’s Guide Poster
6. Turn the Power Switch “On”…. Turn the Cycle Switch “On”. The cycle is now initiated. The system display will show:
7. We recommend not opening the unit after the cycle is completed for
3 –6 Hours or the Temperature is below 160 °F (Depends on
temperature, time, and the amount of solid waste). This allows the unit
to cool down.
8. The resulting ‘Still Bottom’ will range in
consistency from slurry to a marshmallow. All of
this is again dependent on the types of solvents,
type of paint, and the painter’s waste levels and
Recycler settings (Time & Temperature).
9. Dispose of the ‘Still Bottom’ in an approved
Hazardous Waste container and assure proper
labeling.
10. You are now ready for the next cycle of the process.
3) Troubleshooting
1. See “Instruction Manual” Page 35-36
2. Weak Solvent
-This is from the Cleaning process causing evaporation of “Acetone”. Add “Acetone” – typical solvent used in
solvent formulations that starts to evaporate at 80ºF and Boils at 130ºF.
-Water in the solvent –This will weaken the solvent potency.
4) Maintenance
1. Each Use - Replace Recycler Bag. Use only BECCA Recycler Bags to
assure performance 655055-25 (25 PK), 655055- 50 (50 PK)
or 655055-100 (100 PK)
- Remove any contaminants from the bottom of the Boiler
2. Each day - Wipe-down the unit with solvent. The paint and decals
are solvent resistant.
- Remove any contaminants from the bottom of the Boiler
3. Semi-Annually - Blow off condenser (externally) to remove dust and dirt
- Replace BECCA Protect™ Maintenance Coating (831004)
- Review Ground Clamp (823079K)
4. Annually - Replace Seal (551935)
- Blow out Condenser (internally)
- Review & Replace any illegible or damaged Decals
For assistance or service Phone or Fax:
Tel:(800) 655-5649 Fax: (800) 655-5684