manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Behringer
  6. •
  7. Recording Equipment
  8. •
  9. Behringer POWERLIGHT PL2000 User manual

Behringer POWERLIGHT PL2000 User manual

Other manuals for POWERLIGHT PL2000

3

Other Behringer Recording Equipment manuals

Behringer CMD Micro User manual

Behringer

Behringer CMD Micro User manual

Behringer Multicom Pro MDX4400 User manual

Behringer

Behringer Multicom Pro MDX4400 User manual

Behringer Virtualizer Pro DSP2024P User manual

Behringer

Behringer Virtualizer Pro DSP2024P User manual

Behringer V-TONE BASS BDI21 User manual

Behringer

Behringer V-TONE BASS BDI21 User manual

Behringer ULTRAFEX PRO EX3200 User manual

Behringer

Behringer ULTRAFEX PRO EX3200 User manual

Behringer U-CONTRO LUMX25 User manual

Behringer

Behringer U-CONTRO LUMX25 User manual

Behringer Bass V-Amp Pro User manual

Behringer

Behringer Bass V-Amp Pro User manual

Behringer Eurodesk MX2442A User manual

Behringer

Behringer Eurodesk MX2442A User manual

Behringer EURODESK MX3282A User manual

Behringer

Behringer EURODESK MX3282A User manual

Behringer FEEDBACK DESTROYER PRO FBQ2496 User manual

Behringer

Behringer FEEDBACK DESTROYER PRO FBQ2496 User manual

Behringer ULTRA-CURVE PRO DSP8024 User manual

Behringer

Behringer ULTRA-CURVE PRO DSP8024 User manual

Behringer Modulizer PRO DSP1200P User manual

Behringer

Behringer Modulizer PRO DSP1200P User manual

Behringer GUITAR LINK UCG102 User manual

Behringer

Behringer GUITAR LINK UCG102 User manual

Behringer F-Control Audio FCA202 User manual

Behringer

Behringer F-Control Audio FCA202 User manual

Behringer U-CONTROL UCA202 User manual

Behringer

Behringer U-CONTROL UCA202 User manual

Behringer B-Control Fader BCF2000 User manual

Behringer

Behringer B-Control Fader BCF2000 User manual

Behringer Virtualizer Pro DSP2024P User manual

Behringer

Behringer Virtualizer Pro DSP2024P User manual

Behringer XENYX 302USB User manual

Behringer

Behringer XENYX 302USB User manual

Behringer Ultrabass BX3000T User manual

Behringer

Behringer Ultrabass BX3000T User manual

Behringer Eurorack MX1604A User manual

Behringer

Behringer Eurorack MX1604A User manual

Behringer 904A User manual

Behringer

Behringer 904A User manual

Behringer VIRTUALIZER 3D FX2000 User manual

Behringer

Behringer VIRTUALIZER 3D FX2000 User manual

Behringer GRAPHIC EQUALIZER EQ700 User manual

Behringer

Behringer GRAPHIC EQUALIZER EQ700 User manual

Behringer GUITAR LINK UCG102 User manual

Behringer

Behringer GUITAR LINK UCG102 User manual

Popular Recording Equipment manuals by other brands

ThermoFisher Scientific Dionex DRS 600 Installation checklist

ThermoFisher Scientific

ThermoFisher Scientific Dionex DRS 600 Installation checklist

Shure ANIUSB-Matrix user guide

Shure

Shure ANIUSB-Matrix user guide

Nady Audio HE-1 user guide

Nady Audio

Nady Audio HE-1 user guide

AUDAC APM 01 User manual & installation guide

AUDAC

AUDAC APM 01 User manual & installation guide

Teac GF-350 owner's manual

Teac

Teac GF-350 owner's manual

Fractal Audio MFC-101 MARK III owner's manual

Fractal Audio

Fractal Audio MFC-101 MARK III owner's manual

bmcm USB-OI16 manual

bmcm

bmcm USB-OI16 manual

HHB BurnIT CDR-830 Service manual

HHB

HHB BurnIT CDR-830 Service manual

GE VersaMax IC200CPUE05 manual

GE

GE VersaMax IC200CPUE05 manual

IntesisBox MH-RC-MBS-1 user manual

IntesisBox

IntesisBox MH-RC-MBS-1 user manual

Attero Tech unD4l user manual

Attero Tech

Attero Tech unD4l user manual

Sennheiser UI 765 instruction manual

Sennheiser

Sennheiser UI 765 instruction manual

Sony RCD-W1 Operating Instructions  (primary... Service manual

Sony

Sony RCD-W1 Operating Instructions (primary... Service manual

Roland Planet-P  MKS-10 owner's manual

Roland

Roland Planet-P MKS-10 owner's manual

Roland BOSS GT-PRO Turbostart

Roland

Roland BOSS GT-PRO Turbostart

8x8 Inc Valcom V-2001A manual

8x8 Inc

8x8 Inc Valcom V-2001A manual

Waves SUB Align user guide

Waves

Waves SUB Align user guide

Mitsubishi Electric MAC-334IF-E installation manual

Mitsubishi Electric

Mitsubishi Electric MAC-334IF-E installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

POWERLIGHT PL2000
Version 1.0 January 2005
Users Manual
ENGLISH
2
POWERLIGHT PL2000
DEUTSCH
WELCOME TO BEHRINGER!
Thank you for the confidence you have shown in us by purchasing the
PO ERLIGHT PL2000. It is an extremely dependable, premium-featured rack light in
the 19" format. The PO ERLIGHT offers you many mains connectors and the
highest possible safety for maximum flexibility on the stage or at the studio.
CONTROL ELEMENTS
Front-side control elements
Use the POWER switch to power up the PO ERLIGHT PL2000. The PO ER
switch should always be in its Off position whenever you connect the unit
to the mains.
+Merely pressing the POWER switch does not disconnect the unit
fully from the mains. To fully disconnect the unit from the mains,
unplug the power cord from the power outlet. During the installation,
make sure that oth the power cord and the power outlet function
properly. When not using the unit for prolonged periods of time,
please unplug the units power cord from the power outlet.
+Please make sure that the unit is grounded at all times. For your
own protection, you should never tamper with the grounding of the
ca le or the unit itself. The unit must e connected to the mains
with an intact ground wire at all times.
The LIGHT switch activates the rack lighting. The light can also be turned on
independent of the PO ER switch.
The rack light can be rotated and can be individually adjusted to best suit your
lighting needs.
Control elements in the back
There are 8 mains connectors in the back of the PL2000 for providing power
to additional equipment in your rack. The total power load of the equipment
connected to the PL2000 may not exceed 8 A.
CONTROL ELEMENTS
3
POWERLIGHT PL2000
The mains connection is made with a standard IEC receptacle. A matching
power cord is included.
Your rack lights fuse holder is located here. Blown fuses should only be
replaced with fuses of the same type and rating.
This is your PL2000s automatic circuit breaker. If the total load of the equipment
you have connected to the PL2000 exceeds 8 A, the circuit breaker engages
and completely turns the PL2000 off. If this happens, remove one or more of
the units you have connected in order to lower the overall load below 8 A.
After approx. 2 minutes the automatic circuit breaker is reset and your PL2000
can be turned on again. If the circuit breaker engages again, disconnect
additional equipment.
Important information on the top side
Important information about the polarity of the connectors and the maximum
allowed load is located on the top side of your PO ERLIGHT PL2000.
ERIAL NUMBER.
INSTALLATION IN A RACK
The PL2000 requires one height unit (1 HE) for installation in a 19-inch rack.
Please assure that there are additional 10 cm (4 inches) of free space in the back
for connecting cables.
Be sure that there is enough air space around the unit for cooling and, to avoid
overheating, please do not place the EUROPO ER on top of power amplifiers or
other heat-emitting equipment.
For installation in a rack, use M6 machine screws and nuts.
WARRANTY
Ideally, please register your new BEHRINGER equipment directly after the
purchase under www.behringer.com (or www.behringer.de ) and carefully read
the warranty terms and conditions.
BEHRINGER offers a one-year* warranty on material and workmanship, starting
with the date of purchase. You can read the complete terms and conditions of this
warranty at our webpage www.behringer.com (or www.behringer.de).
Should your BEHRINGER product malfunction, we want to have it repaired as
quickly as possible. Please directly contact the BEHRINGER dealer from whom you
have purchased your equipment. If your BEHRINGER dealer is not located near
you, you may also directly contact one of our subsidiaries. A list with contact
addresses of the BEHRINGER subsidiaries is located in the original packaging of
your equipment (Global Contact Information/European Contact Information).
ARRANTY
4
POWERLIGHT PL2000
Technical specifications and appearance subject to change without notice. The information contained herein is correct
at the time of printing. The names of companies, institutions or publications pictured or mentioned and their respective
logos are registered trademarks of their respective owners. Their use neither constitutes a claim of the trademarks by
BEHR NGER® nor affiliation of the trademark owners with BEHR NGER®. BEHR NGER® accepts no liability for any loss
which may be suffered by any person who relies either wholly or in part upon any description, photograph or statement
contained herein. Colours and specification may vary slightly from product. Products are sold through our authorised
dealers only. Distributors and dealers are not agents of BEHR NGER® and have absolutely no authority to bind
BEHR NGER® by any express or implied undertaking or representation. No part of this manual may be reproduced or
transmitted in any form or by any means, electronic or mechanical, including photocopying and recording of any kind, for
any purpose, without the express written permission of BEHR NGER Spezielle Studiotechnik GmbH. BEHR NGER® is
a registered trademark.
ALL R GHTS RESERVED. © 2005 BEHR NGER Spezielle Studiotechnik GmbH,
Hanns-Martin-Schleyer-Str. 36-38, 47877 Willich-Münchheide , Germany.
Tel. +49 2154 9206 0, Fax +49 2154 9206 4903
If no contact information is listed for your country, please contact the distributor
nearest you. Contact addresses can be found in the support area of our website,
www.behringer.com.
Registering your equipment with us after the purchase makes processing possible
warranty claims substantially easier.
Thank you for your cooperation!
*Conditions other than these may apply to customers from the European Union.
EU customers can acquire additional information by contacting BEHRINGER Support
Germany.
SPECIFICATIONS
Connections 8 IEC connectors
Overall load per channel max. 8 A
Overall load for all channels max. 8 A
Fuses
Lighting F 32 mA L 250 V
Main fuse 8 A 250 V (automatic circuit breaker)
Rack light 3.5 atts
Voltage Europe/U.K./Australia 230 V~, 50 Hz
China 220 V~, 50 Hz
USA/Canada 120 V~, 60 Hz
Japan 100 V~, 50 - 60 Hz
Mains connection Standard IEC receptacle
Dimensions (H x x D) approx. 44 mm x 482.6 mm x 126.4 mm
eight (net) approx. 0.75 kg
BEHR NGER continuously strives to assure the highest quality standards possible. Required modifications may be
implemented without prior notice. Technical data and the appearance of the unit may deviate from the above values and/or
illustrations.
SPECIFICATIONS