BeiJer Korenix JetWave 4110L User manual

JetWave 4110L
Industrial Lora Gateway
User Manual
V1.1 Oct. 2019

JetWave 4110L LoRa Gateway User Manual
LoRa
1. Install USB Driver.
1.1 CP210xVCPInstaller_x86.exe: For Windows XP、Vista、win7 32bits.
1.2 CP210xVCPInstaller_x64.exe: For Windows Vista、Win7、Win8 64bits.
2. Copy all files in the "Program Tool" folder in your PC. (WW_BOX_LoRa.exe / SLABHIDDevice.dll /
SLABHIDtoUART.dll).
3. Connect the LORA product and execute the Program Tool (WW_BOX_LoRa.exe).
Noted that:
1. Requires operating system: Windows XP / Vista / 7 / 8 / 10.
2. The software supports the Wireless LoRa RS-485 Gateway_WW-3C28.
Connect the PC for settings diagram

JetWave 4110L LoRa Gateway User Manual
Program Tool (WW_BOX_LoRa.exe)
Icon Introduction
Read setting from device
Write setting to device
Back to All setting list
Continuous writing device from setting parameter file(*.par)

JetWave 4110L LoRa Gateway User Manual
MENU Introduction
File Menu
Open… Open a setting parameter file (*.par)
Save Save the setting parameter file
Save As… Save all settings as another parameter file
Read Device Read setting from device
Write Device Write all settings to device
Main MCU Bootloader Main MCU entry to Firmware Update Mode
DIO MCU Bootloader DIO board MCU entry to Firmware Update Mode
Exit Exit the program
Setting Menu
Language Select the language, such as English\繁體中文\简体中文
Registry Factory functions enable registration code
PC Code Install PC hardware ID

JetWave 4110L LoRa Gateway User Manual
Execute WW_BOX_LoRa.exe
Press Read setting from device and select the correct COM port and BaudRate(You can ignore
BaudRate and the system will automatically search for you).
1. Read setting list from device as below.

JetWave 4110L LoRa Gateway User Manual
Page 6
All Setting List
Device Information
All device information is shown on on the Device Information page.
Model Number This item is product model number
Firmware Main Firmware Version
Hardware Main Hardware Version
PCODE Product CODE for factory use
Firmware (RF) RF Firmware Version
Hardware (RF) RF Hardware Version
PCODE (RF) RF Product CODE for factory use
High Frequency Range (Hz) High band range 862~1020MHz*
Low Frequency Range (Hz) Low band range 410~525MHz*
(*): Will be adjusted according to national regulations.
JetWave4110L

JetWave 4110L LoRa Gateway User Manual
Page 7
Device Setting
※Noted that:
All devices are identical in the setting of frequency and RF BitRate.
All device settings are shown on as follows.
Frequency (Hz)
Setting transmit and receive frequency, the frequency range is 410MHz to 525MHz / 862MHz to
1020MHz.
Tx Power
Setting transmit power High (2W), Middle (1W), Low (0.5W).
Spreading Factor
Setting spreading factor, the range is 7~12. The smaller the value, the greater the transmission rate. **
Bandwidth (KHz)
Setting bandwidth, the range is 7.8~500 kHz. **
Equivalent Bitrate (bps)
Display equivalent bitrate, for reference only. This value will change according to the Spreading Factor and
Bandwidth.
Receiver Sensitivity (dBm)
Display receiver sensitivity, for reference only. This value will change according to the Spreading Factor

JetWave 4110L LoRa Gateway User Manual
Page 8
and Bandwidth.
RS-485 / RS-232 Baudrate (bps)
The Baudrate setting from 4800, 9600, 19200, 38400, 57600, 115200, 230400.
RS-485 Address
Setting the RS-485 device address(1~255).
Modbus RTU Data Filter Function
Check the box to enable Modbus RTU data filter function. This function will be checked the RS-485
address and Modbus RTU checksum.
If this function is enabled, the data input from the RF(LoRa)/ RS-485/RS-232 will be compared with RS-
485 Address and Modbus RTU Data CheckSum.
Enable RS-485 Bias Voltage
Check the box to enable RS-485 Bias Voltage function. RS-485 bias voltage will provided by WW-3C28.
(**):Adjusting Spreading Factor and Bandwidth will affect Bitrate and Sensitivity. Bitrate range is .018 -
37.5 kbps and Sensitivity range is -111 to -148 dBm.

JetWave 4110L LoRa Gateway User Manual
Page 9
RF Packet Setting
※Noted that:
All devices are identical in the Sync. word value to link.

JetWave 4110L LoRa Gateway User Manual
Page 10
Receive Packet Setting
Address base filtering
Broadcast / Node / Group, Broadcast / Node, Broadcast / Group, Node / Group,
Broadcast only, Node only, Group only
Node address 1~255 ※Own Address
Group address 1~255 ※Own Address
Transmit Packet Setting
Target address Type Broadcast, Node, Group
Node address 1~255 ※Node address of the destination (receiver)
Group address 1~255 ※Group address of the destination (receiver)
Pattern association
RX TX
Broadcast
Node
Group
Broadcast / Node / Group
YES
YES
YES
Broadcast / Node
YES
YES
NO
Broadcast / Group
YES
NO
YES
Node / Group
NO
YES
YES
Broadcast only
YES
NO
NO
Node only
NO
YES
NO
Group only
NO
NO
YES
【YES】The device receive is available.
【NO】 The device receive is invalid.
Packet verify Code(.Hex)
Set this value to confirm the packet, only packets that match the value will be received.

JetWave 4110L LoRa Gateway User Manual
Page 11
ModBus RTU setting
Install “WW_ModBus_RTU” tool. For more ModBus setting.

JetWave 4110L LoRa Gateway User Manual
Page 12
Install “WW_P_CMD_Tool” tool. For more ModBus setting.

JetWave 4110L LoRa Gateway User Manual
Page 13
Register Address Mappings
Address
Description
Attribute
0x3000
REG_DI_VAL_1:
DI(AI) #1 Detection value
R
(03H)
0x3001
REG_DI_VAL_2:
DI(AI) #1 Detection value
R
(03H)
0x3002
REG_DI_VAL_3:
DI(AI) #2 Detection value
R
(03H)
0x3003
REG_DI_VAL_4:
DI(AI) #3 Detection value
R
(03H)
0x3004
REG_DI_VAL_5:
DI(AI) #4 Detection value
R
(03H)
0x3010
REG_VOUT_CUR_VAL_1:
Vout Current consumption #1 Detection
value
R
(03H)
0x3011
REG_ VOUT_CUR _VAL_2:
Vout Current consumption #2 Detection
value
R
(03H)
0x3012
REG_ VOUT_CUR _VAL_3:
Vout Current consumption #3 Detection
value
R
(03H)
0x3013
REG_ VOUT_CUR _VAL_4:
Vout Current consumption #4 Detection
value
R
(03H)
0x3014
REG_ VOUT_CUR _VAL_5:
Vout Current consumption #5 Detection
value
R
(03H)

JetWave 4110L LoRa Gateway User Manual
Page 14
0x3020
REG_DIO_EXCEP_STATUS:
DIO Abnormal state
R
(03H)
0x3021
REG_POWER_ELECTRICITY:
Main power (mV)
R
(03H)
0x4000(~0x4001)
REG_DIO_ALL_PAR_1:
DIO#1 All parameter
R/W***
(03H/10H)
0x4002(~0x4003)
REG_DIO_ALL_PAR_2:
DIO#2 All parameter
R/W***
(03H/10H)
0x4004(~0x4005)
REG_DIO_ALL_PAR_3:
DIO#3 All parameter
R/W***
(03H/10H)
0x4006(~0x4007)
REG_DIO_ALL_PAR_4:
DIO#4 All parameter
R/W***
(03H/10H)
0x4008(~0x4009)
REG_DIO_ALL_PAR_5:
DIO#5 All parameter
R/W***
(03H/10H)
0x4010
REG_DIO_VOUT_PAR_1:
DIO#1 Vout parameter
R/W
(03H/06H)
0x4012
REG_DIO_VOUT_PAR_2:
DIO#2 Vout parameter
R/W
(03H/06H)
0x4014
REG_DIO_VOUT_PAR_3:
DIO#3 Vout parameter
R/W
(03H/06H)
0x4016
REG_DIO_VOUT_PAR_4:
DIO#4 Vout parameter
R/W
(03H/06H)
0x4018
REG_DIO_VOUT_PAR_5:
DIO#5 Vout parameter
R/W
(03H/06H)
0x4020
REG_DIO_DI_PAR_1:
DIO#1 DI(AI) parameter
R/W
(03H/06H)
0x4022
REG_DIO_ DI _PAR_2:
R/W

JetWave 4110L LoRa Gateway User Manual
Page 15
DIO#2 DI(AI) parameter
(03H/06H)
0x4024
REG_DIO_ DI _PAR_3:
DIO#3 DI(AI)parameter
R/W
(03H/06H)
0x4026
REG_DIO_ DI _PAR_4:
DIO#4 DI(AI)parameter
R/W
(03H/06H)
0x4028
REG_DIO_ DI _PAR_5:
DIO#5 DI(AI)parameter
R/W
(03H/06H)
0x4030
REG_DIO_DO_PAR1_1:
DIO#1 DO parameter1
R/W
(03H/06H)
0x4031
REG_DIO_DO_PAR2_1:
DIO#1 DO parameter2
R/W
(03H/06H)
0x4032
REG_DIO_DO_PAR1_2:
DIO#2 DO parameter1
R/W
(03H/06H)
0x4033
REG_DIO_DO_PAR2_2:
DIO#2 DO parameter2
R/W
(03H/06H)
0x4034
REG_DIO_DO_PAR1_3:
DIO#3 DO parameter1
R/W
(03H/06H)
0x4035
REG_DIO_DO_PAR2_3:
DIO#3 DO parameter2
R/W
(03H/06H)
0x4036
REG_DIO_DO_PAR1_4:
DIO#4 DO parameter1
R/W
(03H/06H)
0x4037
REG_DIO_DO_PAR2_4:
DIO#4 DO parameter2
R/W
(03H/06H)
0x4038
REG_DIO_DO_PAR1_5:
DIO#5 DO parameter1
R/W
(03H/06H)
0x4039
REG_DIO_DO_PAR2_5:
DIO#5 DO parameter2
R/W
(03H/06H)
***:When reading (03H)REG_DIO_ALL_PAR_x,it require 2 data numbers.
Table of contents
Other BeiJer Gateway manuals
Popular Gateway manuals by other brands

POWERSIDE
POWERSIDE IN-SITE Quick start installation guide

POWERSIDE
POWERSIDE IN-SITE MV Quick start installation guide

RTA
RTA 460MRSQT-N2E Product user guide

RTA
RTA 515RTAENI Product user guide

Viessmann
Viessmann Vitogate 300 Installation and service instructions for contractors

Juniper
Juniper SRX550 quick start

Inteno
Inteno X5669 installation guide

Pepperl+Fuchs
Pepperl+Fuchs VBG-ENXK20-DMD-EV manual

Etross
Etross GoIP400 user manual

Round Solutions
Round Solutions Senseceiver quick start guide

ZyXEL Communications
ZyXEL Communications P-660HW-D Series quick start guide

Irenis
Irenis Blankom IGS-900 Technical data sheet and operation manual