
DAM-E3311User’sManual V6.10
3
¾Power Line: recommended to use more than 0.5 mm2(AWG20) wire
¾Network Cable: CAT-5 series cable
¾Conductive Film: when we use it, the module must be connected to the earth to prevent electrostatic damage
¾Indicator: there are three indicators, one power indicator (POWER), one Fiber connection indicator (Link
(100BASE-FX) and Network indicator (100/10M (Ethernet)), the following is the specific status:
Indicator Color Status Description
on +10~+30V power supply is connected
POWER Green
off No power
on Connect fiber-optic network
flashing working
Link (100BASE-FX) Green/Yellow
off Fiber-optic network is not connected
on Connected to the Ethernet
flashing working
Green(Link)
off Ethernet is not connected
on Connect to the 100MbpsNetwork
100/10M (Ethernet)
Yellow
(Speed)off Connect to the 10MbpsNetwork
Wiring Diagram