Technical Manual
0970 PSL 700 | 0970 PSL 701
Version 1.21 / 24.09.2014
Specifications subject to alteration! Page 16 of 17
The reverse polarity protection only works if the actuator sys
tem power supply is protected by a current overload fuse (10
A, mT) and switches off no later than 10–100 ms after a short
circuit has occurred.
Info 1: The outputs are able to switch currents of 1.6 A with a
frequency of 1 Hz with inductive loads of the
utilization category DC13 (EN6094751).
Info 2: Test proven and approved under the following conditi
ons:
looped through System/Sensor power supply max. 2.5 A
Power supply cable STL 204 (5 x 1 mm²)
Operating temperature range max. 40°C
max. output current 12 A
NOTE!
A power pack with current regulation or an incorrect fuse
will result in the destruction of the module in the event of
reverse polarity.
5. Technical data
5.1 General data
Degree of protection IP 67 (only in locked position)
Operating temperature range 10°C / +60°C
Weight 380 g
Housing PBT
Vibration resistance oscillations 15 g / 5–500 Hz
Vibration resistance shocks 50 g / 11 ms
Torques
Fastening screw M4 1.0 Nm
Connector M12 0.6 Nm
5.2 Technical data – Bus system
Protocol Profibus DP
ID no. 09CA hex
GSD file Lum_09CA.gsd
Data transmission rates 9,6 / 19,2 / 45,45 / 93,75 /
187,5 / 500 KBit/s
1,5 / 3,0 / 6,0 / 12,0 MBit/s
Adjustment of the data automatic at the start of
transmission rate communications
Address range:
Adjustment via Profibus: 1–126 dec
(address switch: "00")
Adjustment via address switch: 1–99 dec
Default address 99 dec
Please see chapter 4.1:
Addressing
Connection M12 male/female connector,
5 poles; please see pin
assignment
5.3 Technical data power supply –
Electronics/Sensors
Rated voltage US24 V DC
Voltage range 19–30 V DC
Power consumption Electronics typ. 70 mA
Voltage Sensors min. ( USystem 1.5 V)
Power consumption Sensors max. 200 mA (at Tu 30°C)
Reverse polarity protection yes
Indication (US) LED green
Connection 7/8" male/female connector,
(5 poles, please see pin
assignment
5.4 Technical data power supply – Actuators
Rated voltage UL24 V DC
Voltage range 19–30 V DC
Galvanic separation yes
Undervoltage threshold typ. 17 V
Delay time
Undervoltage detection < 20 ms
Reverse polarity protection yes
Indication Actuator supply ULLED green
Connection 7/8" male/female connector,
5 poles; please see pin
assignment
5.5 Technical data – Inputs
Input circuit Type 3 according to
IEC 611312
Rated input voltage 24 V DC
Input current at 24 V DC typ. 5 mA
Shortcircuit proof yes
Channel type N.O. pswitching
Number of digital channels 16
Status indication LED yellow per channel
Diagnostic indication LED green per socket
Connection M12 female connector, 5 poles;
please see pin assignment
5.6Technical data – Outputs
Output circuit Type 1.6 A according to
IEC 611312
Rated output current per channel: 1.6 A, please see Info 1
Signal state "1" max. 1.9 A
Signal state "0" max. 1 mA (according to
specification)
Signal level of the outputs
Signal state "1" min. (UL 1 V)
Signal state "0" max. 2 V
Shortcircuit proof yes
Max. output current per module 9.0 A, please see Info 2
Overloadproof yes
Number of digital channels 16
Channel type N.O. pswitching
Status indication LED yellow per channel
Diagnostic indication LED red per channel/socket
Connection M12 female connector, 5 poles;