303
Torque min. 45 in-lb for control of damper surfaces up to 11 sq ft
.
A
pp
l
i
cat
i
o
n
Direct coupled actuators
f
or direct link to LonWorks network. Actuators are easily
installed by direct shaft mounting on air dampers in ventilation and air conditioning
systems. Actuator can be controlled by any compatible L
O
N controller or automation
s
y
stem
.
For proportional modulation of dampers in HVAC systems. Actuator sizin
g
should be
done in accordance with the damper manufacturer’s specifications.
The actuator is mounted directl
y
to a dam
p
er shaft from 1/4” u
p
to 5/8” in diameter
by means of its universal clamp. Shafts up to 3/4” diameter can be accommodated by
an accessor
y
clam
p
.
O
p
eratio
n
The actuator is not provided with and does not require any limit switches, but is
electronically protected against overload. The anti-rotation strap supplied with the
actuator will
p
revent lateral movement
.
The LMX24-LON series
p
rovides 95° of rotation and a visual indicator indicates
position of the actuator. When reachin
g
the damper or actuator end position, the
actuator automat
i
ca
ll
y stops.
Th
e gears can
b
e manua
ll
y
di
sengage
d
w
i
t
h
a
b
utton on
t
h
e actuator cover.
The LMX24-L
O
N actuators use a brushless D
C
motor, which is controlled by an
Application
S
pecific Inte
g
rated
C
ircuit
(
A
S
I
C)
. The A
S
I
C
monitors and controls the
actuator’s rotation and provides a di
g
ital rotation sensin
g
(
DRS
)
function to prevent
d
amage to t
h
e actuator
i
n a sta
ll
con
di
t
i
on.
P
ower consumpt
i
on
i
s re
d
uce
d
i
n
h
o
ldi
ng
mode
.
Add-on auxiliar
y
switches or feedback
p
otentiometers are easil
y
fastened directl
y
onto
the actuator body for si
g
nalin
g
and switchin
g
functions
.
Dimensions (Inches [mm])
4.57"
[
116
]
3
.47"
[88]
2
"
[
50.8
]
0
.
86
"
[22]
2
.
3
4" [5
9
.4
]
1/4” to 3/4” [6 to 20]
5/16” to 3/4” [8 to 26]
D141
Technical Data LMX24-LON
P
ower su
pp
l
y
24 VAC ± 20% 50/60 H
z
24 VDC ± 10
%
P
ower consum
p
tio
n
2.5 W
(
1.2 W
)
Transformer Sizin
g
5 VA
(
Class 2 power source
)
E
lectrical connectio
n
18 GA
p
lenum rated cabl
e
1
/
2” conduit connecto
r
protected NEMA 2 (IP54)
3
f
t [1m
]
Overload protectio
n
electronic throu
g
hout 0 to 95° rotation
A
n
g
le o
f
rotatio
n
max. 95°, ad
j
ustable with mechanical sto
p
e
l
ectron
i
ca
ll
y var
i
a
ble
Torqu
e
45 in-lb [5 Nm]
Direction of rotatio
n
r
e
v
e
r
s
i
b
l
e
with
s
wit
ch
P
os
i
t
i
on
i
n
di
cat
i
o
n
re
f
lective visual indicator
(
snap-on
)
M
anua
l
overr
ide
externa
l
pus
h
b
utto
n
R
unning tim
e
150 seconds (de
f
ault
)
H
umidit
y
5 to 95% RH non condensin
g
(
EN 60730-1
)
A
mbient tem
p
eratur
e
-22°F to 122°F
[
-30°C to 50°C
]
Stora
g
e temperatur
e
-40°F to 176°F
[
-40°C to 80°C
]
H
ousin
g
NEMA 2, IP54, UL enclosure type 2
H
ousin
g
materia
l
U
L
9
4-
5
VA
Ag
ency listin
gs
cULus acc. to UL 60730-1A
/
-2-14,
C
AN
/CS
A E60730-1:02,
CE acc. to 2004/108/EEC and 2006/95/EC
N
oise leve
l
<35dB(A
)
S
ervicin
g
maintenance
f
re
e
Q
uality standar
d
I
SO
900
1
W
e
ight
1.5
lb
s
[
0.7
kg]
L
o
nW
o
rk
s
®
Ce
rtifi
ed
accordin
g
to Lo
n
MARK
®
3
.
3
P
r
ocessor
N
eu
r
o
n
3
12
0
Transceive
r
FTT-10A, compatible with LPT-10
F
unctional
p
ro
f
il
e
accordin
g
to Lo
n
MARK
®
Dam
p
e
r
actuator ob
j
ect #8110
open loop sensor object #1
L
N
S
plug-in for actuator
/
sensor can be run with any LN
S
based integratio
n
tool (min. for LNS 3.x
)
Se
rvi
ce
bu
tt
o
n
a
n
d
s
t
a
t
us
LED according to Lo
n
MARK
®
guideline
s
C
onductors, cable
s
conductor lengths, cable speci
f
ications and
topology o
f
the LonWorks
®
network according to
t
h
e
E
c
h
e
l
on
®
di
rect
i
ve
s
L
o
nW
o
rk
s
a
n
d
L
o
nMAR
K
©
2
00
7-2
009
L
o
nM
a
rk Int
e
rn
a
ti
o
n
al
LMX24-L
ON
Lo
n
Wo
r
ks
®
, Non-Sprin
g
Return, 24 V
M
40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA
304
Accessories
K
-LM20 3
/
4”
[
20 mm
]
S
haft
C
lam
p
A
V6-20 Shaft Extension
ZG-LMSA Shaft Adaptor for 1/2” Diameter Shafts
Z
G
-LM
S
A-1 Shaft Adaptor for 3/8” Diameter Shafts
Z
S
-100 Weather
S
hield -
S
tee
l
Z
S
-1
50
Weather
S
hield - Pol
y
carbonat
e
T
oo
l-
06
8
mm
&
1
0
mm Wr
e
n
ch
S
1A,
S
2
A
Auxiliary
S
witch(es)
P
37
0
Shaft Mount Auxiliary Switch
P
…
A
F
ee
db
ac
k
P
otent
i
ometer
s
S
GA24 Min positioners in NEMA 4 housing
SG
F24 Min positioners
f
or
f
lush panel mountin
g
A
DS-100 Analo
g
to Di
g
ital Switch
NS
V24
US
Batter
y
Back-U
p
Modul
e
ZG-X4
0
Transforme
r
NOTE
:
When usin
g
LMX24-LON actuators, only use accessories listed on this pa
g
e
.
Typical Specification
Proportional control damper actuators shall be electronic direct-coupled type, which
r
equire no crank arm and linka
g
e and be capable o
f
direct mountin
g
to a sha
f
t
f
rom
1/4” to 5/8”. Actuators must
p
rovide control in res
p
onse to a control in
p
ut from an
e
lectronic controller or positioner. Actuators shall have brushless D
C
motor technology
and be protected from overload at all an
g
les of rotation. Actuators shall have
r
eversing switch and manual override on the cover. Run time shall be constant and
i
ndependent o
f
torque. Actuators shall be cULus listed, have a 5-year warranty, and be
m
anufactured under ISO 9001 International Quality Control Standards. Actuators shall
b
e as manu
f
actured by Belimo
.
Wiring Diagrams
V
Possible connection o
f
a
voltmeter
f
or checking
the position
f
eedback U
.
567321
MFT
LON
LON
T
~
+
–
T
~
+
–
V
S
chema
_
L
O
N
_
01
Co
nn
ec
ti
o
n with
ou
t
Se
n
so
r
567321
MFT
LON
LON
T
~
+
–
T
~
+
–
S
ensor scalin
g:
T
he sensors can be scaled with the sensor plu
g
-in
(
sensor table
).
Sensor Temperature range Resistance range Resolution
Ni
100
0
–28 ... +98°
C
8
50 ... 1600
Ω
1
Ω
PT100
0
–
35 ... +155°
C
8
50 ... 1600
Ω
1
Ω
NT
C
–
10 ... +160°
C
(
dependin
g
on type
)
200 ... 60
k
Ω
1
Ω
S
chema_L
O
N_02
Connection with Passive Sensor, e.g. Pt1000, Ni1000, NT
C
567321
MFT
LON
LON
T
~
+
–
T
~
+
–
Requirements fo
r
sw
i
tch
i
n
g
contact
:
The switching contact must be
able to accuratel
y
switch a cur-
r
e
nt
o
f 1
6
mA
@
24 V.
S
chema_L
O
N_03
C
onnection with
S
witchin
g
C
ontact, e.
g
.
Δ
p
-mon
i
tor
567321
MFT
LON
LON
T
~
+
–
T
~
+
–
Poss
i
ble
i
nput volta
g
e ran
g
e:
0 ... 32 V
(
resolution 30 mV
)
S
ensor scalin
g:
Th
e
se
n
so
r
s
ca
n
be
sca
l
ed
with th
e
s
ensor plug-in (sensor table)
S
chema_L
O
N_0
4
Connection with Active Sensor, e.
g
. 0...10 V @ 0...5
0
°
C
L
MX24-L
ON
Lo
nW
o
rk
s
®
, Non-Sprin
g
Return, 24 V
M40024 - 05/10 - Sub
j
ect to chan
g
e. © Belimo Aircontrols
(
USA
)
, Inc.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA
305
Node ob
j
ect #
0
T
he node object contains the object status and object request functions
.
n
viRequest SNVT_obj_reques
t
I
nput variable for requesting the status of a particular object in the node.
n
vo
S
tatus
S
NVT_obj_statu
s
O
utput variable that outputs the current status of a particular object in the node
.
n
voFileDirectory
S
NVT_addres
s
O
utput variable that shows information in the address range of the Neuron chip
.
D
amper actuator object #8110
T
he actuator object is used to map the functions of the MP actuators to the
L
ONWORKS® network.
n
viRel
S
tpt
S
NVT_lev_percen
t
T
he nominal position is assi
g
ned to the actuator via this input variable. This variable is
n
ormally linked to the output variable of an HVA
C
controller.
n
viActuateState SNVT
_
switc
h
A
preset position is assi
g
ned to the actuator via this input variable. Note on priority:
T
he last variable that was active, either nviActuatorState or nviRelSt
p
t, has
p
riorit
y
.
n
viManOvrd SNVT_hvac_overi
d
Th
ese
i
nput var
i
a
bl
es can
b
e use
d
to manua
ll
y overr
id
e t
h
e actuator
i
nto a part
i
cu
l
ar
p
os
i
t
i
on
.
n
voActualValue
S
NVT_lev_
p
ercen
t
T
his out
p
ut variable shows the current actual
p
osition of the actuator and can be used
for control circuit feedback or for displayin
g
positions
.
n
voAbsAngle
S
NVT_angle_de
g
T
his output variable shows the current angle o
f
rotation o
f
the actuator
o
r the valve and can be used to dis
p
la
y
the
p
osition or for service
p
ur
p
oses
.
n
voAbsAirFlow SNVT
_
flo
w
T
his out
p
ut variable is inactive with the SR24ALON-5 rotar
y
actuator and shows a
c
onstant value of 65535 (this variable is only active in conjunction with L
O
N-capable
V
AV controllers)
.
Op
en loo
p
sensor ob
j
ect #1
A
sensor can be connected to the rotary actuator. A passive resistance sensor
(
e.
g
.
N
i1000
)
, an active sensor
(
output 0 ... 32 V
)
or a switch
(
on/off
)
can be connected. The
o
pen loop sensor object transfers the measured sensor values to the L
O
NW
O
RK
S®
n
etwork
.
n
voSensorValue SNVT_xxx
T
his output variable shows the current sensor value. Dependin
g
on the connected
s
ensor, the output variable can be con
f
i
g
ured via the sensor plu
g
-in and speci
f
ically
ad
apte
d
to t
h
e system
.
The SNVT_... can be configured as:
S
NVT_temp_p
S
NVT_lev_percen
t
S
NVT
_
lux
S
NVT_tem
p
S
NVT_abs_humid
S
NVT_
p
ress_
p
S
NVT_switch
S
NVT_enthalpy
S
NVT_smo_obscu
r
S
NVT
_
flow
S
NVT_ppm
S
NVT_power
S
NVT_flow_p
S
NVT_rpm
S
NVT_elec_kw
h
Notes
D
etailed in
f
ormation on the
f
unctional
p
ro
fi
les can be
f
ound on the website o
f
LonMARK
®
K
K
(www.lonmark.org).
The LON-capable damper actuator is certified by LonMARK
®
KK
. Th
e
ac
t
ua
t
o
r
fu
n
c
ti
o
n
s
are supplied with the LonWork
s
®
network as standardized network variables according
to LonMARK
®
KK
. The Node Object #0, the Damper Actuator Object #8110 and the Open
Loop
S
ensor
O
bject #1 are implemented in the actuator
.
LMX24-L
ON
Lo
n
Wo
r
ks
®
, Non-Sprin
g
Return, 24 V
M
40024 - 05/10 - Subject to change. © Belimo Aircontrols (USA), Inc.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA
306
1
Directi
o
n
of
r
o
tati
o
n switc
h
S
witchin
g
ove
r
Direction o
f
rotation chan
g
e
s
2
Pushbutton and green LED d
i
spla
y
O
f
f
No voltage supply or mal
f
unctio
n
Green
,
on Operatio
n
Press butto
n
S
witches on angle of rotation adaption followed
b
y
standard o
p
eratio
n
3
Service button for commissioning LONWORK
S
®
and
y
ellow LED dis
p
la
y
for the LON statu
s
O
f
f
The SR24ALON-5 rotar
y
actuator is connected
and ready for operation in the
L
O
NW
O
RK
S®
network.
Y
e
ll
ow
,
o
n
No a
pp
lication software is loaded in the
SR24ALON-5
.
Yellow, flashin
g
(flashing interval 2 seconds)
The SR24ALON-5 is read
y
for o
p
eration but not
integrated in the L
O
NW
O
RK
S
®
networ
k
(
unconfi
g
ured
).
O
ther flashing code
s
A fault is present in the
S
R24AL
O
N-5.
Press butto
n
Service Pin Messa
g
e is sent to the
LONWORK
S
®
n
etwork
.
4
Gear disen
g
a
g
ement switc
h
Pr
ess
bu
tt
on
Gear disen
g
a
g
ed, motor stops, manual operation
poss
ible
R
e
l
ease
b
utto
n
Gear engaged, synchronisation starts, followed
b
y stan
d
ar
d
operat
i
o
n
5
Service plu
g
For connectin
g
MFT parameterizin
g
and service tool
s
1
2
3
4
5
L
MX24-L
ON
Lo
nW
o
rk
s
®
, Non-Sprin
g
Return, 24 V
M40024 - 05/10 - Sub
j
ect to chan
g
e. © Belimo Aircontrols
(
USA
)
, Inc.
Other Belimo Industrial Equipment manuals
Popular Industrial Equipment manuals by other brands

JohnDow Industries
JohnDow Industries JDI-AF10E owner's manual

Sentinel
Sentinel 989 manual

Bentone
Bentone BG 700-2 Biogas Translation of the original instructions

MYDATA
MYDATA TM8C Upgrade guide

Eriez
Eriez HD36 Installation, operation and maintenance instructions

Vahle
Vahle U 25 Series Mounting instructions and Maintenance

SMC Networks
SMC Networks D-NF001 Operation manual

Xylem
Xylem McDonnell & Miller PSE-800-M Application, Installation, Operation, and Maintenance Manual

MICRO-EPSILON
MICRO-EPSILON interferoMETER operating instructions

Isel
Isel FlatCom L Series instructions

KTR
KTR DATAFLEX 85 Series Operating & assembly instructions

Balluff
Balluff BTL6-A/E500/B50 M E2/E28-KA LA Series Condensed guide