CIAO AT C.S.I.
7
Winter: turn the function selector in the area marked with + and - (g. 
24b) to obtain DHW and heating. In case of a heat request, the boiler 
will switch on and the digital display will show the temperature of the 
heating water, the heating mode icon and the ame icon (g. 25). 
In case of a request for domestic hot water, the display (1 - g. 3) will 
show the temperature of the domestic water, the DHW mode icon and 
the ame icon (g. 26).
Adjustment of the heating water temperature
To adjust the heating water temperature, turn the knob with the 
symbol (g. 27) clockwise in the area marked with + and -.
Summer: turn the selector onto the summer symbol   (g.  24a) 
to activate the traditional function of domestic hot water only. In the 
case of a request for domestic hot water, the display will show the 
temperature of the domestic water, the DHW mode icon and the ame 
icon (g. 26).
Pre-heating (faster hot water): turn the domestic water temperature 
adjustment knob (g. 29) onto the  symbol to activate the pre-heating 
function. The display will show the xed  symbol. Bring the domestic 
hot water temperature adjustment knob back to the required position. 
This function keeps the water in the domestic hot water exchanger hot, 
to reduce standby times when a request is made. The display indicates 
the outlet temperature of the heating water or the domestic hot water 
based upon the request in progress. During burner ignition following a 
pre-heating request, the display shows the ashing  symbol and the 
ame icon (g. 30). To deactivate the pre-heating function, rotate the 
domestic hot water temperature adjustment knob back to the symbol 
. Bring the domestic hot water temperature adjustment knob back to 
the required position. This function cannot be activated when the boiler 
is OFF: function selector on  OFF (g. 34).
Adjusting the domestic hot water temperature
To adjust the domestic water temperature (bathrooms, showers, 
kitchen, etc.), turn the knob with the  symbol (g. 28) in the area 
marked with + and -. The boiler remains in standby until the burner 
ignites in response to a heat request. The display shows the domestic 
water temperature, the DHW mode icon and the ame icon (g. 26). 
The boiler continues to function until the temperatures set on the boiler 
are reached, or the heat request terminates; it will then go back to 
standby. If the digital display shows the icon and an alarm code, this 
means the boiler is in a temporary stop condition (see the "Operating 
status and faults" chapter) (g. 31).
Environment Automatic Adjustment System function (S.A.R.A.)
By setting the heating water temperature selector in the area marked 
with AUTO (g. 32) (temperature value from 55 to 65°C), the S.A.R.A. 
self-adjusting system is activated: the boiler varies the delivery 
temperature according to the closing signal of the ambient thermostat. 
When the temperature set with the heating water temperature selector 
is reached, a 20-minute count begins. If the ambient thermostat still 
requests heat during this period, the value of the set temperature 
automatically increases by 5°C. When the new value is reached, 
another 20-minute count begins. If the ambient thermostat still requests 
heat during this period, the value of the set temperature automatically 
increases by 5°C. This new temperature value is the result of the 
temperature set manually with the heating water temperature selector 
and the increase of +10°C of the S.A.R.A function.
After the second cycle the temperature value should be kept at the set 
value +10°C until the request of the ambient thermostat is met.
Reduced Condensation Formation function
Positioning the adjusting DHW and CH temperature selector to the 
“FCR”  (reduced  condensation  formation,  g.  33)  zone,  the  highest 
delivery temperatures will be selected.
4.3 Switching off
Temporary switch-off
In the event of short periods of absence, set the function selector to 
 (OFF) (g. 34). The display will switch off. In this way (leaving the 
electricity and fuel supplies enabled), the boiler is protected by the 
following systems:
- Heating anti-freeze: this function is activated if the temperature 
measured by the delivery probe drops below 5°C. In this phase, the 
circulator is activated. If the boiler is not in lockout, the burner is also 
activated at minimum output until the delivery water temperature 
reaches 35°C. During the anti-freeze cycle, the symbol (fig. 35) 
appears on the digital display.
- DHW anti-freeze: the function is activated if the temperature 
measured by the domestic water probe drops below 5°C. In this 
phase, the circulator is activated. If the boiler is not in lockout, the 
burner is also activated at minimum output until the delivery water 
temperature reaches 55°C.
During the anti-freeze cycle, the symbol appears on the digital 
display (fig. 35).
- Circulator anti-blocking: an operation cycle is activated every 24 
hours after the last heat request.
Switching off for long periods
In the event of lengthy periods of absence, set the function selector to 
(OFF) (g. 34). The display will switch off. Turn the main system switch 
OFF. Turn off the fuel and water taps of the heating and domestic hot 
water system. In this case, anti-freeze device is deactivated: empty the 
systems, in case of risk of frost.
4.4 Operating status and faults
The operating status of the boiler is shown on the digital display, below 
is a list of the types of displays.
Boiler status Dis
play
Type of alarm
Stand-by - Signal
OFF status OFF None
ACF alarm lockout module A01 Denitive lockout
ACF electronics fault alarm
Limit thermostat alarm A02 Denitive lockout
Air pressure switch alarm A03 Denitive lockout
Water pressure switch alarm
A04 Denitive lockout
Anti-overow pressure switch 
alarm
Reed sensor (if the “Condense 
neutralizer tray” kit is installed)
NTC domestic water fault A06 Signal
NTC heating fault A07 Temporary stop
Parasite ame A11 Temporary stop
Temporary, pending ignition 80°C ashing Temporary stop
Air pressure switch intervention  ashing Temporary stop
Water pressure switch 
intervention  ashing Temporary stop
Calibration ADJ Signal
Preheating active function Signal
Preheating heat request ashing Signal
External probe presence Signal
Domestic water heat request 60°C Signal
Heat request for heating 80°C Signal
Antifreeze heat request Signal
Flame present Signal
Reset function
To restore operation (reset alarms):
Faults A01-02-03
Turn the function selector to OFF (fig. 34), wait 5-6 seconds, then 
turn it to the required position. If the reset attempts do not reactivate the 
boiler, contact the Technical Assistance Centre.
Fault A04
- Insufficient water pressure 
 Check the pressure value indicated by the water gauge:
 if it is less than 0.5 bar, turn the function selector to OFF (fig. 
34) and adjust the filling tap until the pressure reaches a value 
between 1 and 1.5 bar. Then turn the function selector to the 
required position. If these pressure drops occur frequently, contact 
the Technical Assistance Centre.
- Anti-overflow pressure switch
Position the mode selector on (OFF), wait for 5-6 seconds and 
then turn it to the required position. If the fault persists, contact the 
Technical Assistance Centre.
- Full basin (if the “Condense neutralizer tray” kit is installed)
 Remove the basin and empty it (following the instructions supplied 
with the kit). Once the operations have been completed, replace the 
basin. Turn the function selector to OFF, wait for 5-6 seconds 
and then turn it to the required position. If the fault persists, contact 
the Technical Assistance Centre. 
Fault A06
The boiler functions normally but does not guarantee a constant 
domestic hot water temperature, which remains set at around 50°C.
The intervention of the Technical Assistance Centre is necessary.
Fault A07
Request the intervention of the Technical Assistance Centre.