8
4 - SWITCHING ON AND OPERATION
4.1 Switching on the appliance 
Every time the appliance is powered up, a series of data is shown on the 
displayincludingtheuegassensormeterreading(-C-XX)(seeparagraph
4.3 - fault A09); the automatic purge cycle then starts, lasting around 2 min-
utes. During this phase, the three LEDs light up alternately and the symbol 
“”isshownonthemonitor(g.36).
To interrupt the automatic purge cycle proceed as follows:
access the electronic board by removing the housing, turning the instru-
ment panel towards you and opening the board casing.
Then:
-presstheCObutton(g.37).
  Live electrical parts (230 V AC).
To start up the boiler it is necessary to carry out the following operations:
- power the boiler
- openthegastaptoallowtheowoffuel
- set the room thermostat to the required temperature (~20°C)
- turn the mode selector to the desired position:
Winter mode: turningthefunctionselector(g.38)withintheareamarked
+ and - , the boiler supplies hot water for heating and, if connected to an 
externalstoragetank-supplieshotwaterforDHW.
If there is a heat request, the boiler switches on and the boiler status indica-
torLEDlightsupwithaxedgreenlight.Thedisplaythedeliverytempera-
ture(g.40).
If there is a domestic hot water request, the boiler switches on and the 
boilerstatusindicatorLEDlightsupwithaxedgreenlight.
Thedisplayindicatesthedomestichotwatertemperature(g.41).
Adjustment of the heating water temperature 
To adjust the heating water temperature, turn the knob with symbol 
(g. 38) clockwise to increase water temperature and anti-clockwise to
lower it.
Depending on the type of system, the most suitable temperature range can 
be pre-selected:
- standard installations 40-80°C
-oorinstallations20-45°C.
For the details, refer to paragraph 4.5
Adjustment of heating water temperature with an external probe con-
nected
When an external probe is installed, the delivery temperature is automati-
cally selected by the system, which quickly adjusts the ambient temperatu-
re according to variations in the outside temperature.
If you want to alter the temperature value (increasing or reducing the va-
lue automatically calculated by the electronic card), use the heating water 
temperature selector: turn it clockwise to increase the temperature, or anti-
clockwise to reduce it.
The correction possibility is between -5 and +5 levels of comfort, shown on 
the digital display by rotating the knob.
Summer mode only active when the external storage tank is connected:
turning the selector to the summer mode symbol (g.39)activatesthe
traditional domestic hot water only function, the boiler supplies water at 
the temperature set on the external storage tank. 
If there is a domestic hot water request, the boiler switches on and the 
boilerstatus indicator LEDlightsupwitha xed greenlight.The display
indicatesthedeliverytemperature(g.41).
Adjustment of the domestic hot water temperature
CASE A heating only - adjustment does not apply
CASE B heating only + external storage tank with thermostat - adjustment 
does not apply.
CASE C heating only + external storage tank with probe - to adjust the 
temperature of the domestic hot water in the storage tank, turn the knob-
but with the symbol clockwise to increase water temperature and anti-
clockwise to lower it.
Onthecontrolpanel,thegreenLEDasheswithONfor0.5seconds,OFF
for 3.5 seconds.
The boiler is standby status until, after a heat request, the burner switch-
esonandtheindicatorLEDturnsxedgreentoindicateamepresence.
The boiler continues to operate until the temperatures set on the boiler are 
reached, or the heat request is met; after which it goes back on standby.
If the red LED indicator near the symbol(g.44)onthecontrolpanel
lights up, this means the boiler is in temporary shutdown status (see the 
chapter on Light signals and faults).
The digital monitor indicates the fault code detected.
S.A.R.A. function g. 45
Setting the heating water temperature selector in the zone marked by 
AUTO, activates the automatic temperature control system (green led 
ashing): according to the temperature set on the room thermostat and
the time taken to reach it, the boiler varies automatically the heating water 
temperature reducing the operating time, allowing greater ease of operation 
andenergysaving.Onthecontrolpanel,thegreenLEDashesONfor0.5
seconds, OFF for 3.5 seconds.
Reset function
To restore operation, set the mode selector to (g.42),wait5-6seconds
then set the mode selector to the required position, checking that the red 
indicator light is OFF.
At this point the boiler will automatically start and the red lamp switches 
on in green.
N.B. If the attempt to reset the appliance does not activate operation, con-
tact the Technical Assistance Service.
4.2 Switching off
Temporary switch-off
Incaseofabsenceforshortperiodsoftime,setthemodeselector(g.
42) to (OFF).
In this way (leaving the electricity and fuel supplies enabled), the boiler is 
protected by the following systems:
Anti-frost device: when the temperature of the water in the boiler falls 
below 5°C, the circulator and, if necessary, the burner are activated at mini-
mum output levels to bring the water temperature back to the values for 
safety (35°C). During the anti-frost cycle, the symbol (g.46)appears
on the digital monitor.
Circulator anti-blocking function: an operation cycle is activated every 
24 hours.
DHW Antifreeze (only when connected to an external storage tank with 
probe): the function is activated if the temperature measured by the storage 
tank probe drops below 5° C. A heat request is generated in this phase with 
the ignition of the burner at minimum power, which is maintained until the 
water temperature reaches 55° C. During the anti-frost cycle, the symbol 
(g.46)appearsonthedigitalmonitor.
Switching off for long periods
Incaseofabsenceforlongperiodsoftime,setthemodeselector(g.42)
to “ ” (OFF). Turn the main system switch OFF.
Close the fuel and water taps of the heating and domestic hot water sys-
tem.
In this case, anti-frost device is deactivated: drain the systems, in case of 
risk of frost.
4.3 Light signals and faults
The control panel has three LEDs that indicate the boiler operating status:
Green LED
Flashing
Flashing (0.5 seconds on, then 3.5 seconds off) = boiler in standby, there 
isnoame.
Flashing (0.5 seconds on, then 0.5 seconds off) = temporary shutdown of 
the appliance due to the following automatic-reset faults:
- water pressure switch (standby time 10 minutes approximately)
- transitory waiting for ignition.
In this phase, the boiler waits for restoration of working conditions. If after 
the standby time, the boiler does not restore regular operation, the shut-
down will be permanent and the signal light will be red.
Fastashing(0.1secondon;then0.1secondoff;for0.5seconds)=Auto-
maticTemperatureControlSysteminput/outputfunction(g.45).
Setting the heating water temperature selector in the zone marked by 
AUTO (temperature value from 55 to 65°C) activates the Automatic Tem-
perature Control System: the boiler varies the output temperature accord-
ing to the closing signal of the room thermostat. When the temperature set 
with the heating water temperature selector is reached, a 20-minute count-
down begins. If during this period the room thermostat still requests heat, 
the value of the set temperature automatically increases by 5°C. When the 
new value is reached, other 20-minute countdown begins. If during this 
period the room thermostat still requests heat, the value of the set tem-
perature automatically increases by 5°C. This new temperature value is the 
result of the temperature set manually with the heating water temperature 
selector and the increase of +10°C of the Automatic Temperature Control 
System (S.A.R.A.) function. After the second cycle, the temperature value 
is not increased any further (set temperature +10°C) and cycle described 
above is repeated until the room thermostat request is met.
Fixed green 
thereisame,theboilerworksregularly.
Red LED
If the red LED lights up, this indicates the presence of a fault; the monitor 
shows a code interpreted as follows:
To restore operation (deactivate alarms):
Faults A 01-02-03
Position the function selector to (OFF), wait 5-6 seconds then set it to 
the required position.
If the reset attempts do not reactivate the boiler, contact the Technical As-
sistance Centre.