6/6
09/2015
Blind insert comfort
6. Appendix
6.1 Technical data
Rated voltage AC 230 V, + 10 % /- 15 %
Mains frequency 50/60 Hz
MCB max. 10 A
Switching current 5 A (R/L)
Change-over time to the opposite running direction 0.6 sec.
Standby power consumption < 0.1 W
Relative humidity 0 ... 65 % (no condensation)
Operating temperature -5°C … +45°C
Storage/transport temperature -20°C … +60°C
Extension unit cable length max. 50 m
Load cable length max. 100 m
Number of extension units unlimited
Connecting terminal 1 x 4 mm² or 2 x 2.5 mm²
Mounting orientation connecting terminals downwards
Housing installation depth 22 mm
Claw guide installation depth 32 mm
6.2 Accessories
Push-button for blinds order no. 8524 11 xx
Blind time switch order no. 8574 11 xx
Radio push-button for shutters quicklink order no. 8524 51 xx
Radio shutter timer quicklink order no. 8574 51 xx
6.3 Warranty
We reserve the right to make technical and formal changes to the product in the interest of
technical progress.
Our products are under guarantee within the scope of the statutory provisions.
If you have a warranty claim, please contact the point of sale or ship the device postage free
with a description of the fault to the appropriate regional representative.