BEST ACCESS SYSTEMS
Indianapolis, Indiana
14 Install strike plate
1 Mortise the door jamb to accommodate
the strike box and strike plate. (See Instal-
lation Specifications or dimensions, tem-
plate V03 and H11.)
2 Insert the strike box into the mortise in the
door frame and secure the strike with
screws provided.
Caution: The auxiliary bolt must make
contact with the strike plate, as shown
in Figure 19. The auxiliary bolt dead-
locks the latchbolt and prevents some-
one from forcing the latch open when
the door is closed. If the incorrect strike
is installed, a lock-in can occur.
15 Install core
1 Insert the control key into the core and
rotate the key 15 degrees to the right.
2 Insert the core into the cylinder with the
control key.
3 Rotate the control key 15 degrees to the
left and withdraw the key.
Caution: The control key can be used to
remove cores andaccess doors. Provide
adequate security for the control key.
16 Test lock
To test the lock for proper operation, use the
temporary operator card or personal identifi-
cation number (PIN) that came with the lock.
This card or PIN is for temporary use only and
once permanent cards or PINs have been pro-
grammed for the lock, you should delete the
temporary cards or PINs.
These temporary operator cards and PINs will
only work on factory default V Series locks.
For details on programming the lock for
access control, refer to the V Series Intelligent
Programming Software User Manual or the
V Series Handheld Terminal User Manual.
For magnetic stripe card electronic locks
1 With the BEST logo facing toward you,
insert and remove the temporary operator
card (see Figure 20).
The green light flashes and the locking
mechanism unlocks.
2 Turn the lever/knob and open the door.
3 Insert and turn the key to unlatch the door.
For keypad electronic locks
1 Enter the temporary operator PIN 99998.
2 Press
✽.
The green light flashes and the locking
mechanism unlocks.
3 Turn the lever/knob and open the door.
4 Insert and turn the key to unlatch the door.
For proximity card electronic locks
1 Place the temporary operator card in front
of the proximity reader (see Figure 21).
The green light flashes and the locking
mechanism unlocks.
2 Turn the lever/knob and open the door.
3 Insert and turn the key to unlatch the door.
If the mechanism doesn’t unlock, refer to
the following table.
Figure 18
Figure 19
Strike plate
Auxiliary bolt
Figure 20
Figure 21
LEDs Sounder Access You should…
1 long
tone
Denied Use the token at
a moderate
speed.
Green
stays
on
Denied Use the tempo-
rary operator
token, not the
temporary com-
munication
token.
Green
flashes
Denied Connect the
motor wires.
Denied Connect the
battery and con-
nect the out-
side wire
harness.
4T61853/Rev – 1852819 ER-7991-1