Best Living Systems MCI ProtectAIR User manual

Owner’s Manual
Mountable Air Purification
Owner's Manual
MCI™ ProtectAIR

2
Table of Contents
About the MCI™ ProtectAIR
This unit is designed to be permanently mounted to a wall surface in several dierent
applications. The MCI™ ProtectAIR unit can be outfitted with a mounting bracket and
120-240VAC power adapter and used as a wall mounted air purifier in a large room,
small oce, or similar space, or it can be outfitted with rubber feet and used as a
stand-alone unit. The MCI™ ProtectAIR eectively renders bacteria, viruses, mold,
mildew and other contaminants in the air, and on surfaces, harmless on a continuous
basis. Treatment from the MCI™ ProtectAIR unit also eliminates odors to create a
cleaner, safer environment.
The wall mounted (or stand-alone) MCI™ ProtectAIR is designed to improve indoor air
quality by dealing with pollutants in a proactive way. The MCI™ ProtectAIR produces
aggressive ionized oxidizers and trademarked MCI™ multi-cluster ions that are then
distributed throughout the home or office. This trademarked MCI™ Multi-cluster
Ionization Technology, using an enhanced output, represents the newest generation of
proactive air purification, is completely safe, unlike high levels of ozone, and effectively
destroys mold, mildew, bacteria, viruses, odors, volatile organic compounds (VOCs) and
the odors associated with them in the air and on surfaces. When used as part of a
holistic solutions protocol, the MCI™ ProtectAIR provides a comfortable indoor air
environment. This particular air purifier is designed to cover up to 12,000 cubic feet of
living environment. (1,500 square feet with 8’ ceilings).
Specifications ........................................................... 3
Warnings ............................................................... 3
Unit Diagrams ........................................................... 4
Unit Pictures . . . . . . . . . . .................................................. 5
Installation (Stationary Unit) ............................................... 6
Cleaning the Unit ........................................................ 7
Filter Replacement ....................................................... 7
DBI Cell Replacement ................................................... 8
Replacement Part Numbers ............................................... 9
Warranty Information . .....................................................9

3
Specifications
Dimensions.....................10.25” H (260mm) x 8.00” W (203mm) x 3.25” D (83mm)
Weight ..........................................................2.3 lb (1kg)
Stationary Model
Dimensions......................10.25” H (260mm) x 9.75” W (248mm) x 3.75” D (95mm)
Weight .........................................................2.7 lb (1.2kg)
*Depending on variables such as the severity and frequency of pollution, flow of air in the
environment, humidity, and temperature.
Warnings
WARNING: Electrical shock may occur. Hard-wired Installations should be
handled by a licensed professional.
WARNING: Never service the unit while it is connected to a power source.
Electrical shock or injury may occur.
NOTE: A slight odor may be noticeable when the unit is first installed and
operated. This is due to the newness of the UV bulb being used and the initial
cleaning of the contaminated space. The odor is completely harmless.
Record the name and phone number of your Distributor as well as unit serial number.
Name__________________________________________________________________________________________
Phone #: _______________________________________________________________________________________
Serial #: ________________________________________________________________________________________
Stand-Alone Model
Electrical Input .......................... 120/240VAC to 12VDC Power Adapter
Eective Area* ................................................Up to 1,200ft2
Warranty ........................................................... 1 Year

4
Unit Diagrams
Unit Front
Unit Rear
Mounting Bracket
(Stationary Only)
Unit Cover
Air Outlet
Air Intake
Filter Cover Plate
Security Mounting Holes
Power Outlet
DC Power Plug
Unit Bottom

5
Unit Pictures
Wall-Mount Unit
Stand-Alone Unit
Interior

6
STEP 1
STEP 2
STEP 3
Installation (Stationary - Surface Mount)
1. Determine location for desired
placement of unit close enough to
a power outlet to allow the included
120/240 VAC to 12 VDC power
adapter to be plugged in. Typically,
the angled grill should be pointed
upward and mounted as high on the
wall as practical, within 18 inches of
the ceiling if possible.
2. Plug the power adapter’s elbow style
DC connector to the back of the
MCI™ ProtectAIR unit.
3. Attach the MCI™ ProtectAIR unit to the
wall location with included screws,
utilizing the mounting bracket flanges.
Make sure there is adequate clearance
of at least 6 inches above and below
the unit to allow for air flow.
4. Make a proper electrical connection of
the 12VDC power adapter to the outlet.
To Use as a Stand-Alone Unit:
Remove the mounting bracket from the
back of the unit and attach the four (4)
rubber feet provided with the unit to the
bottom of the unit, one on each corner.
(See Stand-Alone Unit image on page 5)

7
Cleaning the Unit
Filter
Filter Replacement
1. Disconnect unit from power source.
2. Remove the Filter Cover Plate from the unit.
3. Remove the Cover from the unit.
4. Wipe everything down with a damp cloth.
5. Replace the Cover of the unit.
6. Replace the Filter Cover Plate of the unit.
7. Reconnect unit to power source.
1. Disconnect unit from power source
2. Remove the Filter Cover Plate from the unit.
3. Remove the used Filter.
5. Replace the Filter Cover Plate.
6. Reconnect unit to power source
WARNING: Make sure to disconnect the unit from its power source before
any maintenance or cleaning is done.
WARNING: Make sure to disconnect the unit from its power source before
any maintenance or cleaning is done.
We recommend replacing the Filter after 90 days or when noticeably contaminated.
See Page 9 for Replacement Part Numbers.
The unit will need to be cleaned inside from time to time as well. Be sure to use extreme
caution when doing this in order to avoid any damage to the unit or harm to yourself.
STEP 2 & 6
STEP 2 & 6
STEP 3 & 5
4. Replace with the new Filter (non-lettered side facing out).
NOTE: A T10 security TORX bit (not included) is required to open the unit.

8
1. Disconnect unit from power source.
2. Remove the Filter Cover Plate from the unit.
3. Remove the Cover from the unit.
7. Replace the Cover.
9. Reconnect unit to power source.
WARNING: Make sure to disconnect the unit from its power source before
any maintenance or cleaning is done.
STEP 3 & 7
See Page 9 for Replacement Part Numbers.
Your DBI Cell should be replaced every 3years. STEP 2 & 8
4. Locate the DBI Cell, rotate a quarter turn
and gently remove from the socket.
5. Repeat step 4 with the second DBI cell (if
included with your unit).
6. Place the new DBI Cell in place into the socket
8. Replace the Filter Plate Cover.
DBI Cell Replacement
NOTE: A T10 security TORX bit (not included) is required to open the unit.
and rotate one quarter turn until the cell is
firmly seated in the socket. Repeat with the
second DBI cell (if included).

9
Replacements Part Numbers
Please reference these part namesand numbers when contacting your dealer
or Best Living Systems (www.bestlivingsystems.com)for replacement parts.
MCI™ ProtectAIR Replacement DBI Cell .............................. SKU281
MCI™ ProtectAIR Replacement Filter ................................. SKU385
Warranty Information
Your MCI™ ProtectAIR unit comes with a one-year manufacturer's warranty.
To view warranty information, warranty options, register your standard
manufacturer's warranty, or purchase a three-year enhanced warranty,
please go to www.blswarranty.com.
To contact Best Living Systems, call 800.728.7206.
Table of contents
Other Best Living Systems Air Cleaner manuals