bintec elmeg TBC1-8ETH User manual

TBC1-8ETH card
Installation Manual
Copyright© bintec Dm 629-I Version 1.3 bintec elmeg
bintec elmeg Manual
TBC1-8ETH card 1

Legal Notice
Warranty
This publication is subject to change.
bintec elmeg offers no warranty whatsoever for information contained in this manual.
bintec elmeg is not liable for any direct, indirect, collateral, consequential or any other damage connected to the de-
livery, supply or use of this manual.
Manual bintec elmeg
2TBC1-8ETH card

Table of Contents
Chapter1 AboutThisManual................................. 1
1.1 SupportedDevices................................... 1
1.2 Warningandnotes................................... 1
1.3 Who should read this manual? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.4 Whatisinthismanual?................................. 1
1.5 How is the information organized? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.6 TechnicalSupport ................................... 1
1.7 RelatedDocumentation................................. 2
Chapter 2 TBC1-8ETH expansion card . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1 TBC1-8ETH expansion card: Characteristics . . . . . . . . . . . . . . . . . . . . . . . . 3
2.2 TBC1-8ETH expansion card: Connectors . . . . . . . . . . . . . . . . . . . . . . . . . 3
Chapter 3 Installing the TBC1-8ETH expansion card. . . . . . . . . . . . . . . . . . . . . 5
3.1 Requirements prior to installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.2 Installing or replacing the TBC1-8ETH expansion card. . . . . . . . . . . . . . . . . . . . 5
Chapter 4 LEDs and connector pinouts: Description . . . . . . . . . . . . . . . . . . . . . 6
4.1 TBC1-8ETH expansion card: LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.2 Connectorpinouts ................................... 6
4.2.1 RJ-45Connector.................................... 6
4.2.2 PoEConnector..................................... 7
Chapter 5 Regulatory compliance and safety information . . . . . . . . . . . . . . . . . . 9
5.1 ManufacturerInformation................................ 9
5.2 WEEEInformation................................... 9
5.3 REACH........................................ 9
5.4 EC Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.5 CEMarking..................................... 10
bintec elmeg Table of Contents
TBC1-8ETH card i

Table of Contents bintec elmeg
ii TBC1-8ETH card

Chapter 1 About This Manual
This installation guide contains step by step instructions on how to correctly install, uninstall and replace the
TBC1-8ETH expansion card in the bintec RM3000 / RM5000 / RM7000 router family.
1.1 Supported Devices
The information contained in this installation manual only applies to the TBC1-8ETH card.
1.2 Warning and notes
Observe the warnings and instructions given in this manual to avoid and prevent injuries or damage during installa-
tion and maintenance. Please follow the security procedures and guidelines when working near electrical equipment.
The warnings and notes are provided in each chapter as appropriate.
1.3 Who should read this manual?
This manual should be read by installers and network administrators who need to install, configure or maintain net-
works. This guide assumes that the installer is familiar with network electronics and technologies.
1.4 What is in this manual?
This installation guide contains the following information:
• A description of the general characteristics of the TBC1-8ETH expansion card.
• A description of the steps to carry out to install the TBC1-8ETH card in the
bintec RM3000 / RM5000 / RM7000 routers.
• A description of the TBC1-8ETH expansion card LEDs and connector pinouts.
1.5 How is the information organized?
This document aims to provide all the information necessary for installing the TBC1-8ETH expansion card in the
bintec RM3000 / RM5000 / RM7000 router family.
•TBC1-8ETH expansion card characteristics.
•TBC1-8ETH expansion card connectors.
• Requirements prior to installation.
• Installing the TBC1-8ETH expansion card.
1.6 Technical Support
bintec elmeg offers a technical support service. Device software can be upgraded on a regular basis for maintenance
purposes and for new features.
Contact information:
Web: http://www.bintec-elmeg.com
Tel. No.: +49 - 911 - 9673 0
Fax: +49 - 911 - 688 0725
Email: support@bintec-elmeg.com
bintec elmeg 1 About This Manual
TBC1-8ETH card 1

1.7 Related Documentation
bintec Dm569-I bintec RM3000 Installation.
Note
The manufacturer reserves the right to make changes and improvements to the appropriate features in
both the software and hardware of this product, modifying the specifications of this manual without prior
notice.
The images showing the front and back panels of the device are for information purposes only. Some
small modifications may exist in the actual device.
1 About This Manual bintec elmeg
2TBC1-8ETH card

Chapter 2 TBC1-8ETH expansion card
This manual focuses on the TBC1-8ETH expansion card.
Sometimes customers require more LAN ports than those available in the router. Depending on the application,
these ports can be used as an expansion of the switch ports available or, may be assigned to a new, independent in-
terface.
The TBC1-8ETH card, compatible with the new bintec RM3000 / RM5000 / RM7000 router family, is designed to
meet these requirements.
The TBC1-8ETH card provides eight additional Gigabit Ethernet ports and can also act as PoE Power Supply Equip-
ment (PSE) - compatible with the current PoE daughter boards - providing power on the Ethernet cable up to 15.40
W (802.3af).
Fig. 1: TBC1-8ETH card
2.1 TBC1-8ETH expansion card: Characteristics
The main characteristics of the TBC1-8ETH expansion card are as follows:
TBC1-8ETH card: Characteristics
Ports 8 RJ45 Gigabit Ethernet PoE port.
Standards IEEE
• 802.3af (POE, optional).
• 802.1Q (VLAN).
• 1000-BaseT.
Speed 1000 Mbps full duplex.
2.2 TBC1-8ETH expansion card: Connectors
Figure 2 shows the front board of the TBC1-8ETH card:
Fig. 2: Front of the TBC1-8ETH card
bintec elmeg 2 TBC1-8ETH expansion card
TBC1-8ETH card 3

The front board elements are as follows:
Elements table for the front of the TBC1-8ETH card
Item Description
A 8 Gigabit Ethernet ports. (RJ45 connector).
B One power connector for PoE power supply, (3x2 male header), optional.
The numbering of each port is the offset to the last switch port. If the baseboard switch has 4 ports, then port +1 is
port 5. If the daughter board does not belong to any switch, then port +1 is port 1of the new Ethernet interface.
2 TBC1-8ETH expansion card bintec elmeg
4TBC1-8ETH card

Chapter 3 Installing the TBC1-8ETH expansion card
This chapter provides information on how to install and uninstall the TBC1-8ETH expansion card in the bintec
RM3000 / RM5000 / RM7000 routers.
This information includes:
• Requirements prior to installation.
• Installing or replacing a TBC1-8ETH expansion card.
3.1 Requirements prior to installation
To configure the care, you must be able to access the bintec RM3000 / RM5000 / RM7000 router through a console
or a Telnet connection. For further information, please see the Configuring for Configuration section under the bintec
Dm569-I bintec RM3000 Installation manual.
3.2 Installing or replacing the TBC1-8ETH expansion card.
To install or replace a TBC1-8ETH card, please see the Expansion Slot section in manual bintec Dm569-I bintec
RM3000 Installation.
bintec elmeg 3 Installing the TBC1-8ETH expansion card
TBC1-8ETH card 5

Chapter 4 LEDs and connector pinouts: Description
This chapter provides information on the TBC1-8ETH expansion card LEDs and connector pinouts.
4.1 TBC1-8ETH expansion card: LEDs
The TBC1-8ETH expansion card has two LEDs per port: a green one and an orange one. They both function accord-
ing to the following criteria:
Fig. 3: TBC1-8ETH card: LEDs
LEDs table of the TBC1-8ETH card
Item State
Green (reflects the link
state)
Off => Link has not been detected.
On => Link has been detected.
Blink => Activity.
Blink speed => link speed (1000 blinks at 84 mSec, 100 blinks at 170 mSec and 10
blinks at 340 mSec) The LED will blink 3 times on each new link up, even if there is no
activity, so the speed of the link can be observed.
Orange (reflects the PoE
state)
Off => Open Circuit. No PoE is applied or port is disabled.
On => Correct class has been detected and power is applied or forced.
Rapid blinking => Shortcut detected.
Slow Blinking => Detection error (Signature Low or High).
4.2 Connector pinouts
The TBC1-8ETH expansion card has one RJ-45 connector.
4.2.1 RJ-45 Connector
The following figure shows the RJ-45 connector pinouts.
Fig. 4: RJ-45 Connector Pinouts
The following table display the information associated to each connector pinout:
4 LEDs and connector pinouts: Description bintec elmeg
6TBC1-8ETH card

TBC1-8ETH card RJ-45 Connector Pinouts
RJ-45 pinouts FE Signals GE Signals
1 BI-DA+ BI-DA+
2 BI-DA- BI-DA-
3 BI-DB+ BI-DB+
4 -- BI-DC+
5 -- BI-DC-
6 BI-DB- BI-DB-
7 -- BI-DD+
8 -- BI-DD-
Note
The Ethernet connectors have a MDI-X and auto-polarity auto-detection feature that acts bidirectionally.
You do not need a null HUB cable to connect it to another Ethernet interface.
The following table details the characteristics of the RJ-45 switch connectors controlled by the ESR-APC-POE card:
TBC1-8ETH card PoE Characteristics
Power out Spare-pair power, which uses the free wire pairs (Mode B).
Pinout polarity Pinouts 4 and 5 (V+) ; Pinouts 7 and 8 (V-).
Output voltage -48 V.
User port power 15.5 W(max.).
Note
Do not forget to connect the PSU to the PoE connector in the device.
4.2.2 PoE Connector
The following figure shows the PoE connector pinouts:
Fig. 5: PoE connector pinouts
The following table display the information associated to each PoE connector pinout:
bintec elmeg 4 LEDs and connector pinouts: Description
TBC1-8ETH card 7

TBC1-8ETH card PoE Connector Pinouts
Pinouts Voltage
6, 5, 4 -48 VDC
3, 2 ,1 0 VDC
4 LEDs and connector pinouts: Description bintec elmeg
8TBC1-8ETH card

Chapter 5 Regulatory compliance and safety information
5.1 Manufacturer Information
Brand bintec
Manufacturer bintec elmeg
Country Germany
Postal Address Suedwestpark 94
90449 Nuremberg
Germany
International Phone +49 - 911 - 9673 0
5.2 WEEE Information
The waste container symbol with the >X< indicates that the device must be dis-
posed of separately from normal domestic waste at an appropriate waste disposal
facility at the end of its useful service life.
Das auf dem Gerät befindliche Symbol mit dem durchgekreuzten
Müllcontainerbedeutet, dass das Gerät am Ende der Nutzungsdauer bei den
hierfür vorgesehenenEntsorgungsstellen getrennt vom normalen Hausmüll zu
entsorgen ist.
El símbolo del contenedor con la cruz, que se encuentra en el aparato, significa
que cuando el equipo haya llegado al final de su vida útil, deberá ser llevado a los
centros de recogida previstos, y que su tratamiento debe estar separado del de
los residuos urbanos.
5.3 REACH
In compliance with the REACH Candidate List, the delivered product and product packaging do not contain chemical
substances above a concentration limit of 0.1% weight by weight (w/w). This declaration will be updated whenever
any changes occur or other chemical substances are added to the REACH Candidate List. Information is currently
provided to consumers upon request.
bintec elmeg 5 Regulatory compliance and safety information
TBC1-8ETH card 9

5.4 EC Declaration of Conformity
English (EN) This equipment is in compliance with the essential requirements and other relev-
ant provisions of:
Directive 2014/30/EU (EMC)
Directive 2014/35/EU (LVD)
Directive 2011/65/EU (RoHS)
of the European Parliament
Spanish (ES) Español Este dispositivo cumple con los requisitos esenciales y con las normas correspon-
dientes de las siguientes directivas:
Directiva 2014/30/UE (EMC)
Directiva 2014/35/UE (LVD)
Directiva 2011/65/UE (RoHS)
del Parlamento Europeo
German (DE) Deutsch Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren
entsprechenden Vorgaben der
Richtlinie 2014/30/UE (EMC)
Richtlinie 2014/35/UE (LVD)
Richtlinie 2011/65/UE (RoHS)
des Europäischen Parlaments.
Note
Directive 2014/30/EU (EMC) replaces Directive 2004/108/EC (EMC) on 20th April 2016
Directive 2014/35/EU (LVD) replaces Directive 2006/95/EC (LVD) on 20th April 2016
The EC declaration of conformity and additional product documentation can be accessed here: ht-
tp://www.bintec-elmeg.com
5.5 CE Marking
This equipment is in conformity with the CE procedures and marking.
5 Regulatory compliance and safety information bintec elmeg
10 TBC1-8ETH card
Table of contents
Popular Computer Hardware manuals by other brands

Roland
Roland HipHopCollection SR-JV80-12 owner's manual

ekwb
ekwb EK-FC680 GTX SOC water block Installation and mounting manuals

AMD
AMD B59 user manual

Gigabyte
Gigabyte GC-WIFI7 installation guide

Sun Microsystems
Sun Microsystems Netra t1 Series installation guide

Data Translation
Data Translation DT300 Series Getting started manual

IBASE Technology
IBASE Technology SI-64 Series user manual

Thermo King
Thermo King Smart Reefer 2 Driver guide

Vinpower
Vinpower LightScribe Software installation & quick start usage guide

Panasonic
Panasonic 2SC3757 Specification sheet

Cross Technologies
Cross Technologies 1200-05 instruction manual

Texas Instruments
Texas Instruments DRV8811EVM user guide