BioSmart Prox-E User manual

BioSmart Prox-E
Installation Guide
www.biosmart-tech.com

1 Prox-E Installation Guide v1.2|10.2018|en
Contents
Safety Instructions.............................................................................................................................................2
1. Overview ....................................................................................................................................................3
Specifications......................................................................................................................................3
Part names and functions...................................................................................................................4
Package contents................................................................................................................................5
Opening the case................................................................................................................................5
Circuit board.......................................................................................................................................6
Circuit board LEDs and jumpers .........................................................................................................6
Connector names and description .....................................................................................................6
2. Installation .................................................................................................................................................8
Cable types .........................................................................................................................................8
General installation notes ..................................................................................................................8
Mounting on wall ...............................................................................................................................8
Mounting on DIN-rail..........................................................................................................................9
Power supply connection .................................................................................................................10
Network connection.........................................................................................................................10
BioSmart Readers connection ..........................................................................................................11
Fail-safe lock connection (with external power supply) ..................................................................12
Fail-safe lock connection (without external power supply).............................................................13
Fail-secure lock connection (with external power supply)...........................................................13
Fail-secure lock connection (without external power supply) .....................................................14
Exit buttons and door sensors connection...................................................................................15
Wiegand output connection.........................................................................................................16
Wiegand input connection ...........................................................................................................17

2 Prox-E Installation Guide v1.2|10.2018|en
Safety Instructions
Safety instructions must be followed in addition to International Standards (ISO/IEC)*, and other safety
regulations.
Caution
Caution indicates a hazard with a low level of risk which, if not avoided, could
result in minor or moderate injury.
Note
Note indicates an important remark, which should be taken into attention.
Caution
General requirements:
Read, follow and retain instructions –All safety and operating instructions
must be read and followed properly before putting the unit into operation.
Do not turn on the power supply until all installation procedures are
finished –this may lead to injury or equipment damage.
Do not disconnect or connect cables while unit is powered on –this may
lead to unit malfunction and software errors.
Do not expose unit to heat or fire –high temperature impact may lead to
case deformation and circuit board damage.
Make sure that all cables and screws are fastened properly - otherwise
case damage or circuit shortcut may happen.
Note
Additional requirements:
Use a clean, dry cloth to remove any dirt or dust from the unit.
*IEC 60204-1: Safety of machinery –Electrical equipment of machines. (Part 1: General requirements)

3 Prox-E Installation Guide v1.2|10.2018|en
Overview
The BioSmart Prox-E Controller is designed for use as part of the BioSmart biometric access
monitoring and control system. The controller provides a means to track working hours and
attendance by identifying users through the unique biometric characteristics of fingerprints and
RFID proximity cards. It can also be used for access monitoring and control.
Controller is designed to work with BioSmart BS-RD and BioSmart Mini readers.
Controller is compatible with BioSmart Studio software version V5.0.3.269 and above.
Specifications
Number of users*
30 000
Logged events
100 000
Number of time groups
50
Power supply
12V±15%, 0,4A
Power relay outputs (NC, С, NO outputs)
2
Power rating of power relays
12-24V, 7А
Readers
Up to 4
Readers interface
RS-485, Wiegand
Wiegand outputs
1
Discrete inputs
6
Network interface
Ethernet, (IEEE 802.3, 10BASE-T,
IEEE 802.3u, 100BASE-TX)
Operating temperature
0 to +50 °C
Case type
Laid-on plastic
Dimensions (H x W x D)
145 х 100 х 40 mm
Weight
Net:190 g; gross:275 g
Warranty
3 years
Note: * - Each user can be provided with single card code

4 Prox-E Installation Guide v1.2|10.2018|en
Part names and functions
Name
Description
“Alarm” LED
Alarm indication
“Work” LED
Work mode indication
Mounting screw
Fastens front cover
Mounting holes
Suited for fixing screws
Cable inputs
Detachable panels, suited for cable inputs

5 Prox-E Installation Guide v1.2|10.2018|en
Package contents
Item
Number, pcs
BioSmart Prox-E Controller
1
Mounting kit (four 6х35 dowels, four
3.5х38 self-tapping screws)
1
Opening the case
Remove the front cover retaining screw
Detach the cover from the rear panel to access the circuit board.

6 Prox-E Installation Guide v1.2|10.2018|en
Circuit board
Circuit board LEDs and jumpers
Name
Type
Description
VL2
LED
Indicates if Relay 1 is powered on
VL3
LED
Indicates if Relay 2 is powered on
RX
LED
Indicates BS-RD or Biosmart Mini connection
TX
LED
Indicates BS-RD or Biosmart Mini connection
K4
Jumper
Transfer +12V voltage to C1 if closed
K5
Jumper
Transfer +12V voltage to C2 if closed
IP RST
Jumper
IP settings reset
BOOT
Jumper
Boot mode
VL1
Opto-isolator
Controls case opening
Connector names and description
№
Name
Description
Used for
1
GND
Power supply -ground
Power supply
2
+12V
+12V Power supply
Power supply
3
NO1
Normally open relay 1 output
Fail-secure lock
4
C1
Common relay 1 output
Fail-safe lock/ Fail-secure lock
5
NC1
Normally closed relay 1 output
Fail-safe lock
6
GND
Ground
Lock power supply commutation
7
NO2
Normally open relay 2 output
Fail-secure lock lock
8
C2
Common relay 2 output
Fail-safe lock/ Fail-secure
9
NC2
Normally closed relay 2 output
Fail-safe lock
10
GND
Ground
Lock power supply commutation

7 Prox-E Installation Guide v1.2|10.2018|en
11
IN1
Discrete input 1
Enter/exit buttons, door sensors
12
IN1+
Discrete input «+»
Enter/exit buttons, door sensors
13
IN2
Discrete input 2
Enter/exit buttons, door sensors
14
IN2+
Discrete input «+»
Enter/exit buttons, door sensors
15
IN3
Discrete input 3
Enter/exit buttons, door sensors
16
IN4
Discrete input 4
Enter/exit buttons, door sensors
17
VC0
Reader power supply 12V
Reader power input
18
GND
Ground
Reader ground
19
WI00
Wiegand input 00
Reader, wiegand 00
20
WI01
Wiegand input 01
Reader, wiegand 01
21
SP0
Reader speaker input
Reader, speaker output
22
L_G0
Reader green indicator input
Reader, green indicator output
23
L_R0
Reader red indicator input
Reader, red indicator output
24
WI01
Wiegand input 01
Reader, wiegand 00
25
WI11
Wiegand input 11
Reader, wiegand 01
26
SP1
Reader speaker input
Reader, speaker output
27
L_G1
Reader green indicator input
Reader, green indicator output
28
L_R1
Reader red indicator input
Reader, red indicator output
29
VC1
Reader power supply 12V
Reader power input
30
GND
Ground
Reader ground
31
RD+
485+
BS-RD, Biosmart Mini 485+
32
RD-
485-
BS-RD, Biosmart Mini 485-
33
IN6+
Discrete input 6 «+»
Enter/exit buttons, door sensors
34
IN6
Discrete input 6
Enter/exit buttons, door sensors
35
IN5+
Discrete input 5«+»
Enter/exit buttons, door sensors
36
IN5
Discrete input 5
Enter/exit buttons, door sensors
37
W00
Wiegand output 00
External controller wiegand input 00
38
W01
Wiegand output 01
External controller wiegand input 01
39
+485
RS-485 interface «+»
BCR (Zflex) Relay control module 485 +
40
-485
RS-485 interface «-»
BCR (Zflex) Relay control module 485 -

8 Prox-E Installation Guide v1.2|10.2018|en
Installation
Cable types
№
Cable connection
Max. length
Type
1
Ethernet (IEEE 802.3)
100 m.
Four twisted pair cables of no lower than category five
with a wire size of no less than 0.2 mm2
2
Power source
50 m.
Duplex cable with a wire size of no less than 0.75 mm2(for
example, 3192Y)
3
Turnstile, lock
20 m.
Duplex cable with a wire size of no less than 0.75 mm2(for
example, 3192Y)
4
BioSmart Mini, BS-RD
500 m.
Four twisted pair cables of no lower than category five
with a wire size of no less than 0.2 mm2
5
Exit buttons, sensors
10 m.
CQR-6 or RAMCRO-6 cable
6
Wiegand interface
(input and output)
60 m.
Four twisted pair cables of no lower than category five
with a wire size of no less than 0.2 mm2
General installation notes
Install the controller on vertical surface;
Cables must be installed in accordance with the operational code for electrical
installations;
Do not lay cables within 30 cm of sources of electromagnetic interference;
All cables must only intersect power cables at a right angle;
All cable extensions must be soldered.
Carefully check for mechanical damage on the surface of the controller circuit board and
case;
In order to avoid short circuits, the protected ends of cables used to connect the controller
must not exceed 5 mm.
Mounting on wall
1. Decide where to install controller, using a mounting template.
2. Drill holes, according to a mounting template and insert dowels inside the holes.
3. Cut out cable input plates

9 Prox-E Installation Guide v1.2|10.2018|en
4. Place controller on wall and fix it with self-tapping screws.
5. Connect power supply, readers, locks, and buttons, if needed, according to p.2.5-2.11 . Put
cables through previously made holes.
6. Attach the covering and fix the retaining screw.
Mounting on DIN-rail
1. Place the lower clip on the edge of the rail.
2. Pull the upper clip (2) with a slot-head screwdriver.
3. Press the controller to the DIN rail (1), the upper clip must snap under the pressure of the
spring.

10 Prox-E Installation Guide v1.2|10.2018|en
Power supply connection
Use a DC 12 V power supply adaptor with a minimum of 1,500 mA, which has obtained the
approval of IEC/EN 60950-1;
See recommended cable type and maximum length of the cable in Cable types table.
Network connection
See recommended cable type in Cable types table;
The order of connections in the cable’s modular connector must correspond to the TIA/EIA-
568-B standard.

11 Prox-E Installation Guide v1.2|10.2018|en
BioSmart Readers connection
See recommended cable type in Cable types table;
Note
Prox-E supports up to four readers
Caution
Avoid star-type topology when connecting readers
Unique address should be provided for each reader;
Addresses are set using switches on readers board;
Set addresses according to following table:
Address
Switches position
0
1
2
3

12 Prox-E Installation Guide v1.2|10.2018|en
Fail-safe lock connection (with external power supply)
See recommended cable type in Cable types table;
Install a diode as it shown on figure, to protect controller relay from reverse current. Use
1N4007 diode (1000V,1A) or similar;
Use separate power supplies for lock and controller;
Caution
Make sure K4 jumper is off

13 Prox-E Installation Guide v1.2|10.2018|en
Fail-safe lock connection (without external power supply)
See recommended cable type in Cable types table;
Install a diode as it shown on figure, to protect controller relay from reverse current. Use
1N4007 diode (1000V,1A) or similar;
Caution
Make sure K4 jumper is on
Fail-secure lock connection (with external power supply)

14 Prox-E Installation Guide v1.2|10.2018|en
See recommended cable type in Cable types table;
Install a diode as it shown on figure, to protect controller relay from reverse current. Use
1N4007 diode (1000V,1A) or similar;
Use separate power supplies for lock and controller;
Caution
Make sure K4 jumper is off
Fail-secure lock connection (without external power supply)
See recommended cable type in Cable types table;
Install a diode as it shown on figure, to protect controller relay from reverse current. Use
1N4007 diode (1000V,1A) or similar;
Caution
Make sure K4 jumper is on

15 Prox-E Installation Guide v1.2|10.2018|en
Exit buttons and door sensors connection
See recommended cable type in Cable types table;

16 Prox-E Installation Guide v1.2|10.2018|en
Wiegand output connection
See recommended cable type in Cable types table;

17 Prox-E Installation Guide v1.2|10.2018|en
Wiegand input connection
See recommended cable type in Cable types table;

Support
support@biosmart-tech.com
+420 246 097 126
Skype: BioSmart TechSupport
+420 246 097 126
Konevova 2660/141, 130 00 Prague, Czech Republic
www.biosmart-tech.com
sale@biosmart-tech.com
Table of contents
Other BioSmart Controllers manuals
Popular Controllers manuals by other brands

Fortinet
Fortinet FortiADC 1000F quick start guide

Johnson Controls
Johnson Controls Tyco KT-1 installation guide

CM
CM riese Safe M.1 Original operating instructions

BRONKHORST
BRONKHORST MASS-STREAM D-5100 instruction manual

Dynamite
Dynamite FUSE DYN4955 instruction manual

Jandy
Jandy JVA 2444 Pro Series Installation and operation manual