9
6.6COUNTINGPIECES
Throughthereferencefunction it’spossibletousethescaleasapiececounter.
COUNTING PROCEDURE
The operationstobecarriedout arethefollowing:
1) Placethe emptycontaineronthescaleandpressTAREtotareit.
2) Check that the zeroisonthedisplayandput the quantityofpieceschosen fortheSAMPLE on thescaleand
press FUNC.
3) The displaysuggestsaREFERENCE QUANTITY. The possibleoptionsare:10,20, 50, 100,and200.
4) Press TARE thenumberoftimesneededtoreachthedesired samplesize.
5) Press ZERO; the displaywillindicate"------"and the indicatorwill calculatethe Average PieceWeight (APW).
Afterafewinstantsthedisplaywill indicatethequantityselectedput onthe platform.
5) Add the rest of theitemstocountinthe containerand whosevalue will appearonthe display.
6) Unload thescale,theAPWwill remainstored inmemoryforthenext counting of similarpieces, withouthaving to
repeattheREFERENCEoperation.
7) Bypressingthe %keyone switchesfromthe displayofthe numberofpiecestothedisplayof the averagepiece
weightandofthenet weight.
9) Percancel or tocarryoutanew reference operation, press the FUNC keyandrepeat the operationsas
describe inpoint 1).
6.7SAMPLEWEIGHT PERCENTILE
Inthisfunctioning mode,thedisplayshowstheweightexpressedasapercentile,comparingitwithareferenceweight
forwhichthe 100percentilehasbeenalreadylinked.
MATCHING PROCEDURE
-Put the referenceweightonthe scale.
-Press the %key.
-The scalehasexecutedthepercentilematching anddisplays thepercentileoftheweighton thescale.
-Unload thescale:thefollowing weighswill be expressedasapercentage inreferencetothereferenceweight.
-Tocancelor executeanewmatching operation,press the FUNC keyandrepeatthe operationsdescribed
above.
6.8CHECKINGQUANTITIES
The scaleisfittedwiththe quantitycheck function with2thresholds.Anacousticalarm andthreereferencesymbols
on the displayareenabled on the basisof theset thresholdsandtheweighing result.
The check canbemadeonthe weight,thepricesoronthe percentile.
Tocheckthepiecesone shouldexecutethe referenceoperation (seesection 6.6)and thenconfigurethethresholds.
Tocheckthepercentageoneshouldlinkaweight tothe100percentile(seesection6.7)and thenconfigurethe
thresholds.
6.8.1SETTINGOFTHE WEIGHTTHRESHOLDS
Press LIMIT:
-The displayenablesthe“HI”icon andshows“000.000”,withthefirstblinking digit.Inthissteponeconfiguresthe
upperthreshold.
-Usethe FUNC keytoclearthevalue,the TARE keytoincreasethe valueofthe digit, the %keytogoonthe
previousdigit and the FUNC keytogo on thefollowing digit.
-Confirm the entered valuewith ZERO orpress PRINT toexit without confirming.
-The displayenablesthe “LO”icon and shows“000.000”,withthe firstdigitblinking.Inthisstep one configuresthe
lowerthreshold.
-Usethe FUNC keytoclearthevalue,the TARE keytoincreasethe valueofthe digit, the %keytogoonthe
previousdigit and the FUNC keytogo on thefollowing digit.
-Confirm the entered valuewith ZERO orpress PRINT toexit without confirming.
-The thresholdsareconfigured and theindicatorreturnstoweighing.