4
EN
Here,“b” means the total number of loads and “XXXX” indicates the total number
of adding.
DISPLAY OF TOTAL WEIGHT
When the displaying value is within the zero range, press key to see the total
number of adding and the total weight of loads. It will rstly display the total num-
ber of loads. For example, the scale shows “b0327”, that indicates that 327 loads
are weighed so far. Press again, it will display the four left-hand number of the
added value. For instance,“H 108” indicates the left-hand number of the total weight
is “108”. Press for the third time, it will show the four right-hand number of the
total weight. For your information,“ L 2896” indicates the right-hand number of the
total weight is “2896”.Accordingly, the total weight of the loads is “1082896 kg”.
SET PARAMETERS
Press during self-check sequence from “99999” to “00000”
Function Operation Display Remarks
Division Press du-
ring self-check
sequence from
“99999” to
“00000”
dS 1 0: Measured division
1: Selectable division
Press to change.
Sets buzzer Press bEE 1 0: Disable
1: Enable
Press to change.
Zero point drift Press to 1 0: Close
1:Activate
Press to change.
Switch off the
scale mode Press oFF 2 0:The scale will keep displaying.
1:The displaying window will go
into sleeping mode with stable
weighing value for 30 minutes.
It will be activated when the
displaying value is unstable or
by pressing the key.
5
EN
As presented on the panel, , are operating keys, of whose functions
are the following:
Use this key to add the load weight. It is also being used for forwarding
(scrolling forward only) the setup menu.
Press this key to keep the current displaying weight and the indicator
will switch on. Press the key again to turn off temporarily holding function.
For value input, press this key to circulate between desired values.
Press this key to tare and the indicator will switch on. Press the key
again to turn off temporarily tare function.
Press this key to zero the current displaying value.
LB/KG- When the red light is on, that means the unit is on KG.When the light
turns green, the unit is on LB.
4. BASIC OPERATIONS
POWER ON
Turn on the power switch at the back of the scale (“ON” position).The scale will
display the version number and then the maximum weight capacity individually for
approximately one second.Then the light will display “99999”,”88888”…….”00000”
alternately, followed by a self-check of reset sequences. During that process the
display will be blinking for some time.After this has stopped the display will show the
actual weight loaded to the hook. Now the crane scale is in accurate weighing mode.
INITIAL ON ZEROING
After switching the power on, the scale enters into weighing mode and then displays
“0”kg. If it is not “0’kg, it’s normally caused by overloading the permitted value of the
initial on zero range. In this case, please switch off the scale and re-start it and choose
the desired parameter. (Please see initial on zero Range below).
MANUAL ADDITION
When the displaying value is above zero, with weight on the scale, press key.The
current weighing value will be added to the total weight if within valid parameter.
(Please see “Set parameters”) The scale will show “bXXXX” for about one second.