Bisque 40016512 User manual

4 0 016512
40016512
NOTICE D’UTILISATION
OPERATING INSTRUCTIONS
GEBRUIKSAANWIJZING
BEDIENUNGSANLEITUNG
MANUALE DI ISTRUZIONI
MANUAL DE INSTRUCCIONES
INSTRUKCJA OBSŁUGI

41
11/2017
40
40016512
1 Overview
1.1 Introduction 42
1.2 Warnings 42
1.3 Overview of your appliance 44
2 Installing your appliance
2.1 Warnings 45
2.2 Connecting the appliance 48
3 Using your dual-energy towel radiator
3.1 Use as central heating 49
3.2 Use as electrical heating 49
4 Putting the remote control into service
4.1 Initialization 51
4.2 Status of LED 53
4.3 Displays 54
5 Use of remote control
5.1 Operating remote control 56
5.2 Operating mode selection 57
5.3 Calibration of temperature setting 62
5.4 Window open/close detection 63
5.5 Advanced parameter setting for remote control 64
6 Heating boost 66
7 Setting a P1 and/or P2 programme 71
8 Maintenance and troubleshooting
8.1 Routine maintenance operations 75
8.2 Troubleshooting 75
8.3 Replacing batteries 78
9 Services and guarantee 79
EN

42
40016512
43
11/2017
1. Overview
1.1 Introduction
Dear customer,
Thank you for choosing this device.
This product has been manufactured in accordance with our stringent quality requirements to
give you total satisfaction. To get the most out of your radiator, we advise you to read these instruc-
tions carefully and keep them to hand.
Thank you for your purchase.
1.2 Warnings
CAUTION (TOWEL DRYER): To avoid any danger to very
young children, you are advised to install this appliance so
that the lowest heating bar is at least 600 mm off the oor.
CAUTION (RADIATOR): To avoid overheating, do not cover
the heating appliance.
Do not sit on the heating appliance.
Caution, hot surface.
CAUTION - Some parts of this product can become very hot
and cause burns. Particular attention has to be given where
children and vulnerable people are present.
Children of less than 3 years should be kept away unless conti-
nuously supervised.
Children aged from 3 years and less than 8 years shall only swit-
ch on/off the appliance provided that it has been placed or installed
in its intended normal operating position and they have been given
supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children aged from 3
years and less than 8 years shall not plug in, regulate and clean the
appliance or perform user maintenance.
This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or men-
tal capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use
of the appliance in a safe way and understand the ha-
zards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
A towel radiator must be used for the purpose for which it
is intended and not as a table, chair, toy, ladder, etc.
This appliance should be plugged or connected, accor-
ding to rules and standards in application, only by an autho-
rized person.
It is protected from splashes of water, and can be
installed within volume 2 (see section 2.1) as long as the
electrical controls are out of reach of anyone using the bath
or shower. It must not be connected to ground.
The electricity supply must be protected by a residual
current device with a maximum of 30mA, especially when
installed in a room containing a bathtub or shower.
Before carrying out any maintenance operation on your
appliance, ensure that it is switched off (see section 5.1).
IMPORTANT If the power cable is damaged, for safety
reasons it must be replaced by the manufacturer, the
manufacturer’s after-sales service department or a simi-
larly qualied person.
IMPORTANT The heating appliance must not be placed
underneath a power outlet.
IMPORTANT This appliance is not intended for use at
altitudes exceeding 2000 m.

44
40016512
45
11/2017
1.3 Overview of your appliance
ELECTRICAL TOWEL DRYER OR RADIATOR:
This heating appliance is lled with a precise quantity of specic
oil. Any repair work requiring the oil tank to be opened should only
be carried out by the manufacturer or their after-sales service depart-
ment, which should also be contacted in the event of an oil leak.
When disposing of the heating appliance, comply with the regula-
tions in force on the disposal of oil.
This electrical appliance with circulating uid is delivered ready to use.
It is plugged and lled with a high-performance thermal mineral oil before leaving the factory.
This uid was specially designed for this use and requires no special maintenance.
As soon as the appliance is switched on, you will notice certain differences compared to a stan-
dard electric heating system:
- the electric heating element heats the uid, which gradually and naturally starts circulating in
your appliance;
- the properties of the uid are such that it takes approximately ten minutes for the radiator to
reach its optimum surface temperature, depending on the model and the room temperature when
the appliance is switched on;
- this principle also ensures consistent and sustained heating even when the element is no
longer powered.
DUAL-ENERGY TOWEL DRYER:
This appliance is designed for connection to the central heating system and comes unplugged.
PROGRAMMING:
You can set two separate weekly programmes, P1 and P2 with the remote control.
2. Installing your appliance
2.1 Warnings
The exible cable supplied with your appliance is designed to be
connected to the mains via a junction box that must be placed behind
the appliance, with no need for a plug.
In a kitchen or bathroom, the junction box must be positioned at
least 25 cm from the oor.
The appliance must be installed as described in this document and
in accordance with the applicable European and French standards,
including CEI 60364.7.701 and NF C15-100, as well as the rules of
good professional practice.
For other countries (apart from France), the appliance must be ins-
talled in accordance with standards in force and with rules of good
professional practice in the country of use.
IMPORTANT The example shown only concerns a bathtub. For
other bathroom xtures, please consult your installer.
IMPORTANT The system must be tted with an omnipolar circuit-
breaker with a minimum contact opening of 3mm.
Volume 0
Volume 1Volume 2
0.60 m
2.25 m

46
40016512
47
11/2017
To ensure your system is safe:
- ensure that an area of at least 50 cm in front of the appliance is
clear of objects which might hinder air circulation (furniture,
chairs, etc.);
- position a shelf at least 10 cm above the top of your radiator;
- use mounting screws suitable for your wall;
- do not expose the radiator to intense or prolonged humidity.
This appliance should never be installed with the electrical connec-
tion box positioned topside.
Always turn off the electricity supply (circuit-breaker + pilot wire)
before making any connections.
To get the most out of your appliance and enjoy the highest
standards of comfort, we recommend that you install the appliance
near places with high heat loss (windows, doors, etc.) wherever
possible.
You will nd a complete set of assembly instructions in your
appliance’s box.
≥100mm
≥100
mm
≥ X mm*
≥500
mm
≥100mm ≥100
mm
≥500
mm
≥100mm
≥100mm
≥100mm
≥100mm
≥500
mm
≥100
mm
≥100mm
NOTE: Electric towel radiators are designed to be covered safely.
However, to ensure that your appliance works efciently, you are
advised not to cover it completely. Doing so will increase the tem-
perature and cause the internal cutout to turn off the appliance.
* See installation manual for value of X
RECOMMENDATIONS FOR THE OPEN WINDOW DETECTION FUNCTION
(SEE CHAPTER 5.4)
The position of your device affects the way the open window detection function works. It should
be placed as close as possible to the opening part, but should not be installed near a door.
In addition to the arrangement of your installation in the room, its function is also affected by the
temperature setting on the device, and the outdoor temperature.

48
40016512
49
11/2017
2.2 Connecting the appliance
The technical specications of your radiator are shown on its nameplate.
Please note these down before installing it and before requesting any after-sales assistance.
When connecting the appliance to the mains, you must observe:
• the voltage indicated on the nameplate;
• conventional colour coding:
– blue or grey: neutral
– brown: live
– black: pilot wire
CONNECTING PRINCIPLE WITH PILOT WIRE:
Your appliance is equipped with a pilot wire for connection to a pilot wire programming base unit
(not supplied with the appliance).
CONNECTING PRINCIPLE WITHOUT PILOT WIRE:
If the pilot wire is not connected, it must be insulated for safety reasons. Under no circumstances
must it be connected to earth.
N (blue or grey) Neutral
Live
Pilot wire (base unit)
Live
Neutral
L (brown)
Pilot wire (black)
Pilot wire (black)
L (brown)
N (blue or grey)
3. Using your dual-energy towel radiator
IMPORTANT This appliance has been designed to be used ei-
ther in central heating mode or electric mode. Each application
requires special, detailed procedures to be followed. Inappro-
priate use may damage the resistance as a result of excessive
uid temperatures, particularly in the event of simultaneous use
in electric and central heating modes.
Any inappropriate use will render the contractual guarantee null
and void.
3.1 Use as central heating
Ensure that the control unit is off.
The supply valve must be open to let water from the central heating system circulate.
3.2 Use as electrical heating
A. When using the dual-energy, towel-drying radiator in "electric mode", close the supply valve
only and NEVER CLOSE THE HEATING UNIT’S OUTLET since this enables the uid to expand
towards the installation.
B. Ensure that the appliance is sufciently full by opening the bleed tap at the top. Close it again
if there is a steady ow of water. A sponge and small container should be used for this operation.
If the pressure is inadequate for bleeding the heating unit:
• ll the central heating system with water up to the level indicated on your gauge,
• contact your heating specialist,
• inform the operating company (where heating is collective).
C. To start the appliance, follow the same procedure as for an electric towel-dryer.
If the central heating system is equipped with a circulation pump which is independent of the
boiler, it must in all circumstances be turned off (risk of siphoning the heating unit in the event
that connections are not perfectly watertight).
IP: protection level of your appliance against the
ingress of solid foreign bodies and water spray
Voltage and power required for installation
Appliance reference number
Class II: double insulated
OF: serial number
Manufacturer code
IP XX
XXX–XXX–XXX–XX
230V ~ XXXXW
OF: XXXXXXXXXX XXXXXX
N CONSTRUCTEUR XXXXXX
NOTE:
Your appliance is equipped with an integrated electronic control system so we cannot accept
any liability should the appliance be used with pilot wire programming base units that function by
disconnecting the supply voltage (refer to the instructions supplied with your control unit).
CAUTION
Closing it may cause excessive pressure to build up with consequential damage to the
heating unit.
IMPORTANT: The appliance should only be turned on when properly lled with water (failure to
comply may invalidate the guarantee).

50
40016512
51
11/2017
IMPORTANT This radiator is equipped with a resistance which has an integrated power shut-
off and fuse. Using the radiator without water will permanently damage the fuse as well as
the resistance. In this case it must be changed though "not under the manufacturer’s gua-
rantee". Using the radiator only partially lled with water causes the heating function to shut
off automatically. Alternate function will continue as long as the main heating section is not
properly lled.
If you notice that the electrical part of your towel dryer is activated, but that it fails to heat up
inspite of thermostat demand or positive working operation, carry out the following operations:
1) Ascertain that your radiator is full of water (see paragraph B).
2) Press on the key of the remote control for 2 seconds (see chapter 5.1) to stop the electrical
operation of the appliance for 30 to 60 minutes. This operation is necessary to cut off the thermal
safety device.
3) Press the key again for 2 seconds: the radiator is ready to heat up properly.
4. Putting the remote control into service
modemo
d
e
mode
mode
mode
The time setting screen is displayed, showing 00:00. Press and hold the +or -keys, to set
the time quickly.
During initialisation: pressing P1P2 takes you back to the previous screen.
Then proceed to set the day of the week:
mode
boost
mode
boost
mode
boost
mode
boost
mode
boost
mode
boost
1Monday 5 Friday
2Tuesday 6Saturday
3Wednesday 7Sunday
4Thursday (for example)
You then proceed as described in chapter 4.1 to ensure your
appliance works correctly.
4.1 Initialization

52
40016512
53
11/2017
Pairing essential procedure when you rst turn the appliance on!
Make sure you only pair one appliance and one remote control at a time.
LED:
To ensure the LED can be seen properly, you can pair your appliance before
fitting it on the wall, or else use a small mirror.
The first time the appliance is turned on, the LED turns on as a steady magenta
light, to show that pairing has not yet been done (see chapter 4.2).
Procedure using the unit on the back of your appliance:
WARNING!
You must always rst activate the pairing function on the appliance itself, before
activating it on the remote control.
1) Press on the LED once, on the back of the appliance.
Wait until the LED stops ashing magenta and changes colour.
2) Press again on the LED on the back of the appliance.
The LED ashes magenta again. You then have one minute to pair your appliance with the
remote control.
WARNING
The appearance of the
LED may vary according
to the appliance model
(see cover page 3).
CLIC
Pairing (cont)
mode
boost
mode
boost
mode
boost
mode
boost
mode
boost
mode
boost
Press for 5
seconds
on the +
key.
It searches
for the
appliance
for a few
seconds.
If pairing fails, the display
on the control goes back to rF 0.
You can then try pairing again by pressing
the + key for 5 seconds (check rst that the
appliance is still ready to pair:
the LED is ashing magenta).
If pairing still does not work,
contact your dealer.
4.2 Status of LED (on radiator or towel dryer)
STATUS
COLOUR Fixed Flashing Off
Green Eco mode
•Standby
•Powered down
•Stop (pilot wire)
•Stop load
shedding (pilot
wire)
Red Comfort mode Boost
Blue Frost-free mode /
Load shedding (pilot wire)
Open window
detected
Yellow T° override° Error
Magenta Pairing error /
Appliance not paired Pairing underway
Resetting the time and the day:
To reset the time and the day:
Check the remote control is turned on.
Go to settings by holding down P1P2 and mode simultaneously.
Set the time and the date, press mode to go to the End screen, then press mode again to
conrm and exit.

54
40016512
55
11/2017
ICON EXPLANATION
Frost-free mode operation
Eco mode operation
Comfort mode operation
Programmed mode operation
Manual or programmed boost
Window open detected (icon ashes)
Time setting required
Battery usage indicator
Interface lock
Override indicator
Programming on-going
Connection indicator
Programme in Comfort mode
Programme in Eco mode
Current time (programme)
Operating Modes
Scroll through times of day (prog)
Days of the
week (prog)
Prog
mode
4.3 Displays (remote control)
Preferred
temperature
Programming
on-going
Interface lock
Connection indicator
Override
Time/date setting indicator
Battery life indicator
Window open detection
NOTE:
Screen lighting turns off automatically if no key has been pressed for the past
5 seconds.
The screen goes to standby after 1 minute.
The standby mode does not affect the functioning of the radiator, and pressing
any key will make the screen light up again.
The screen must be on for the pressing of a key to have an effect
(e.g. temperature setting, changing a parameter, etc.).

56
40016512
57
11/2017
FROST-FREE MODE
ECO MODE
LOCKING INTERFACE (child lock)
ON/OFF
The remote control is turned on: the controller emits
an audible signal.
The remote control is turned off: the controller
emits two audible signals.
Turning off the remote control also turns
off the radiator or towel dryer.
Your remote control can only operate one
appliance.
5. Use of remote control
5.1 Operating remote control
It is impossible to change the operating mode or the temperature.
It is also impossible to trigger a manual boost.
COMMENT:
Changes of mode ordered by a pilot wire controller (not supplied with your appliance) will not be
disabled by this function.
mode
boost
2
seconds
mode
boost
mode
boost
mode
boost
5 basic operating modes: Frost-free, Eco, Comfort,
programmes P1 & P2
(recommended if premises unoccupied for more than 24
hours)
Your appliance is set to ensure a minimum temperature of 7°C in
your room, to avoid any risk of freezing.
The user cannot change this temperature setting.
The LED on the appliance is on, showing blue.
(recommended if the room is unoccupied for more than
2 hours)
The economy mode can operate in 2 different ways:
- either the eco temperature is linked to the Comfort tempera-
ture;
- or the eco temperature is unlinked (independent).
See the next page for details of how each one works.
See chapter 5.5 Advanced parameters for how to link or unlink
Eco temperature and Comfort temperature.
WARNING:
Your appliance operates in eco linked mode by default.
The LED on the appliance is on, showing green.
5.2 Operating mode selection
mode
boost
Press on -
and mode for
5 seconds
mode
boost
mode
boost

58
40016512
59
11/2017
ECO MODE (continued)
PROGRAMMES P1 AND P2
COMFORT MODE
A) Linked Eco operation
The linked economy mode allows the temperature to be reduced by 3.5°C compared to the
desired temperature level for the COMFORT setting.
The user cannot change this temperature set-
ting. It cannot be higher than 19°C or lower
than 7°C.
B) Unlinked Eco operation
You can choose to unlink the Eco mode temperature from that of the Comfort mode (see
chapter 5.5 parameter 2). You can then choose the desired room temperature when the
appliance is running in Eco mode.
The unlinked eco temperature must differ by at least 1° from the temperature set for Comfort
mode. (e.g.: your Eco temperature cannot be higher than 18°C if your Comfort temperature is
set at 19°C).
If you don't enter a setting, the unlinked Eco temperature will have a default value of 15.5°C.
(recommended if the room is occupied)
This temperature level can be adjusted from 7 to 28°C in
0.5°C steps.
The LED on the appliance is on, showing red. mode
boost
mode
boost
mode
boost
(Pre-set programmes)
Your appliance's remote control includes two daily programmes, P1 and P2. These are based on
various room usage scenarios which alternate between Comfort mode and Eco mode for your
appliance, depending on the time.
The LED on the appliance will light up with the colour corresponding to the current operating
mode (see chapter 4.2).
P1 is to heat your room between 5 and 9am, then from 5 to
11pm (e.g. working day).
P2 is to heat your room between 5 and 9am, from 12 to 2pm
and then from 5 to 11pm (e.g. working day, returning home at
midday).
NOTE:
You can also set a detailed procedure of these programmes P1 and P2 yourself (see
chapter 7).
Default content for
programme P1
Default content for
programme P2
mode
boost
mode
boost
7 to
19°C

60
40016512
61
11/2017
PILOT WIRE CONTROL
PILOT WIRE CONTROL (continued)TEMPERATURE OVERRIDE
In the programmed operating modes for your appliance (P1 or P2) you can override the
operation of your appliance locally, by changing the preferred temperature level.
The LED on the appliance is on, showing yellow.
This override is cancelled when there is a change of status on the programme, or by pressing
the mode key again.
Your appliance is tted with a pilot wire. You can manage the appliance from your main control
unit if you prefer (see connection in chapter 2.2).
See chapter 5.5 Advanced parameter setting (parameter 3) to enable or disable the pilot wire
mode.
WARNING:
Your appliance operates in pilot wire mode by default.
The pilot wire controller takes over control of your appliance only when it is in Comfort
mode.
See the control unit user manual for instructions on how to operate it.
The LED on the appliance will light up with the colour corresponding to the operating mode
specied by the control unit (see chapter 4.2).
The remote control will cause the icon for the operating mode specied by the control unit to
ash.
Example: the control unit sends an Eco mode command
When your installation is tted with a load shedding system connected at the pilot wire
input, this can send your appliance a priority command to turn off (the appliance
LED goes off) or for Frost-free mode (the appliance LED shows blue).
In both cases, the frost-free icon will be displayed on the remote control screen.
Load shedding will take over the operating of your appliance, even if the pilot wire
function is disabled in the advanced parameter setting.
PILOT WIRE OPERATION
Icons
(remote control)
LED colour
(appliance)
Command sent
(control unit)
Boost function
Red Comfort Available
Green Comfort -1° Available
Green Comfort -2° Available
Green Eco Available
Blue
Frost-free (in all
operating modes on
the appliance)
Available
Off Stop (in all
operating modes on
the appliance)
Not available
mode
boost
mode
boost
mode
boost

62
40016512
63
11/2017
5.3 Calibration of temperature setting
Once your appliance has been working for several days, if you notice a difference between the
temperature noted in your room and the temperature programmed on your appliance, you can cali-
brate your appliance in 0.5°C steps, following the procedure below.
Access advanced settings (see chapter 5.5). Press the mode key several times to nd the
temperature settings calibration function (parameter 4).
If the ambient temperature measurement is different from your appliance’s temperature setting,
press the -or +keys until they match.
You can calibrate your temperature measurement to +/- 5°C.
Then press the mode key to leave advanced parameter settings (see chapter 5.5).
mode
boost
Your thermometer must be
placed in the middle of the room,
about 1.30 m above the oor,
with no furniture between it and
the radiator.
mode
boost 10
20
5
15
mode
boost
EXAMPLE:
You measure 19°C in your room, while
the temperature setting on your remote
control is 21°C. Press the -key 4 times
while in setting 4, until the display
shows -2°C (so 21-2=19°C).
10
20
5
15
5.4 Window open/close detection
Your appliance may detect a signicant drop in temperature, caused for instance by a window
standing open in winter. It will automatically adapt and operate to save energy.
By default, the window open/close detection function is enabled on your remote control. To
disable this function, change the corresponding advanced parameter (see chapter 5.5, parameter 1).
IMPORTANT To make the best use of this function, your appliance must be placed close to the
opening with no furniture or other object nearby.
The quality of the window open/closed function depends on a number of factors, such as the
position of the appliance, how fast the temperature in the room rises/falls, the type of window,
etc.
IMPORTANT The room temperature is measured near the appliance.
After opening a window, your appliance should detect the
associated temperature drop within a reasonable period. It will then
adapt its operating mode by automatically switching to the frost-free
temperature (7°C).
When an open window is detected, your appliance causes the
function icon to ash.
When your room temperature rises after the window is closed, the appliance should resume its
operating mode (Comfort mode for instance), before detection was initiated, within a reasonable
length of time.
Starting or stopping a boost (manual or programmed), as well as a change in opera-
ting mode, suspends the window opening/closing function for 60 minutes, the required
time for the room temperature to stabilise.
OK
OK
OK

64
40016512
65
11/2017
5.5 Advanced parameter setting for remote control
WARNING!
Access to parameter setting is possible only when the remote control is off.
Some parameters on your remote control can be adjusted according to how you use it.
mode
boost
mode
boost
Back to
previous
parameter.
Go to
the next
parameter.
Parameter
number Parameter
value
No Parameter Description Default
setting
Setting
0Duration
of Boost
operation
Adjustable from 15 to 120 minutes in 15 minute steps 60 Press the +or -key
1Window
open
detection
Value 0 (function disabled) or 1 (function enabled) 1 Press the +or -key
2Eco
temperature
Value 0 (eco temperature unlinked) or 1 (eco temperature
linked)
1Press the +or -key
Press on P1P2 and
mode for 2 seconds
to enter.
WARNING!
It is essential to get
to the nal “End” screen,
to conrm your parameter
changes.
mode
boost
2
seconds
No Parameter Description Default
setting
Setting
3Pilot wire Value 0 (pilot wire disabled) or 1 (pilot wire enabled) 1 Press the +or -key
4Ambient
temperature
calibration
Adjustable from -5.0°C to 5.0°C in 0.5°C steps 0.0 Press the +or -key
5None --
6None --
7Re-pairing
radio-
frequency
Value 0 (unpaired command) or 1 (paired command) rF0 ou rF1 Press on +or -key to
re-pair an appliance
which was previously
paired but has lost the
link.
8Default
display
Value 0 (time) or 1 (temperature setting) 1 Press the +or -key
9Display
version
number and
reset (unpai-
ring).
Back to factory settings
Warning!
All your settings as well as the pairing, will be deleted.
x.xx Press on +key for 10
seconds to reset.
End Display para-
meter setting
output
Quit the settings menu Short press on
mode or for 2 seconds
on .
After no key has been pressed for one minute, the remote control will automatically
quit the advanced parameters and turn off.

66
40016512
67
11/2017
USE OF MANUAL BOOST
6. Heating boost
This function provides extra heat when required. When activated, the appliance operates at full
power, without taking into account the temperature set on the remote control.
After being triggered, the operating time is 2 hours maximum; it can be interrupted at any time.
The LED on the appliance ashes red during a boost.
Boost operation can be activated 2 ways:
• manual boost
• programmed boost
mode
boost
mode
boost
The Boost
duration is
displayed.
mode
boost
mode
boost
mode
boost
Reduce
duration
of boost in
steps of 15
minutes.
Increase
duration of
boost in steps
of 15 minutes
(total maximum
duration of 120
minutes).
The default
time for a manual boost
is 60 minutes.
USE OF MANUAL BOOST (continued)
USE OF PROGRAMMED BOOST
This function is used to set the start time for the boost, to be triggered automatically every day
at the same time (if the programme is activated).
This boost will operate during the period set in the advanced parameters (see chapter 5.5
parameter 0).
Boost will be triggered in Eco, Comfort, P1 or P2 modes, and will take over the normal operating
of your appliance.
mode
boost
mode
boost
Early
exit from
manual
boost.
The expected
duration of
the boost is
nished.
The appliance
returns to
normal
operating
mode. mode
boost
mode
boost

68
40016512
69
11/2017
SETTING A PROGRAMMED BOOST
mode
boost
mode
boost
The start time
required can now
be set.
mode
boost
mode
boost
Conrm the
start time and
go back to the
current opera-
ting mode.
mode
boost
Program the start
time for the daily
boost (in 15-minute
steps), pressing +
or -.
You can now enable your programmed boost.
Press and
hold P1P2
and boost
simulta-
neously.
ACTIVATION AND RUNNING PROGRAMMED BOOST
mode
boost
mode
boost
When the set time is reached,
boost starts.
The icon ashes through-
out the boost period.
The current boost duration is
displayed.
mode
boost
mode
boost
mode
boost
mode
boost
mode
boost
The icon
is displayed.
The pro-
gramme is
activated and
on standby.
Press on the
boost key for
2 seconds.
The icon is
displayed to indicate
the programme is
activated.

70
40016512
71
11/2017
ACTIVATION AND RUNNING PROGRAMMED BOOST (continued)
mode
boost
mode
boost
mode
boost
Press
on the
boost key
for 2 seconds.
Note:
The total continuous
operating time for the
boost should not last more
than 2 hours
(120 minutes).
Note:
It is mandatory to
set the starting time to
enable the automatic boost
(see chapter 4).
The programmed
boost is disabled.
The boost will not
automatically start
the next day.
You can quit
a programmed boost
at all times by pressing
the boost key.
The expected duration of the boost
is nished.
The appliance returns to normal
operating mode.
The boost will start again the next
day at the same time, as long as
the programme is activated (
icon xed).
INTRODUCTION
ACCESS TO PROGRAMMING
7. Setting a P1 and/or P2 programme
The setting temperature for P1 and P2 modes is linked to the programming set by the user depen-
ding on the time and day. There are two possible modes for each hour, either COMFORT, or ECO.
WARNING!
The programmes P1 and P2 can have a maximum of 10 changes of mode per day
(from Comfort to Eco or Eco to Comfort).
Long press (P1P2 and
+) open settings for
programme P1.
Long press (P1P2 and
-) open settings for
programme P2.
mode
boost
mode
boost
mode
boost Short press on
mode: move to
next day.
Long press on
mode: move to
next day, copies
the current daily
programme.
Short press on
P1P2: back to
previous day.
Long press on
P1P2: back to
previous day, copies
the current daily
programme.
Program the
current time in
Comfort mode.
Program the
current time in
Eco mode.

72
40016512
73
11/2017
SETTING EACH HOUR OF THE DAY
After selecting the operating mode for the nal hour of the day, the programming function
automatically moves on to the rst hour of the next day.
mode
boost
mode
boost
mode
boost
mode
boost
Program current
hour in Comfort
mode and go to
next hour.
Program current
hour in Eco mode
and go to next
hour.
ACCESS TO PROGRAMMING (continued)
mode
boost
mode
boost
mode
boost
Starting position:
day 1, time 0
Indicator of day to program
Indicator of time to program
MANUAL MOVE TO PREVIOUS DAY
MANUAL MOVE TO NEXT DAY
QUIT PROGRAMMING (at any time)
mode
boost
mode
boost
mode
boost
mode
boost
Back to previous
day, positioned
on hour 0.
mode
boost
mode
boost
mode
boost
mode
boost
Move to next day,
positioned on
hour 0.
mode
boost
mode
boost
The remote control
stores the programming
entered, even if you quit
while programming.

74
40016512
75
11/2017
COPY/PASTE FUNCTION (help for programming)
mode
boost
mode
boost
mode
boost
mode
boost
mode
boost
mode
boost
mode
boost
mode
boost
Long press on
P1P2: back to
previous day,
copies the current
daily programme.
Long press on
mode: move to
next day, copies
the current daily
programme.
8. Maintenance and troubleshooting tips
8.1 Routine maintenance operations
High-quality materials and surface treatment protect your appliance against corrosion and
impacts.
To maximise the service life of your appliance, we recommend you take the following precau-
tions:
- Never use abrasive or corrosive products on the outer surfaces of the appliance (except the
electrical parts); use warm, soapy water.
- For the casing of the control unit and the remote control, use a dry (solvent-free) cloth.
8.2 Troubleshooting
Despite all our efforts in manufacturing our products, you may encounter some easy-to-solve
operating failures. In this case, please consult the table below to nd our suggested solution.
Nonetheless, should you fail to solve the problem encountered, please contact your supplier's
after-sales service for assistance.
Problem Diagnosis Procedure
The appliance is not
heating.
The temperature setting on the
remote control is incorrect.
Check the remote control is set to ask
the appliance to start heating (see
chapter 5.2).
The mixed appliance has not
lled with water properly.
Check the lling of the appliance (see
chapter 3.2).
The appliance is operated by a
programming unit.
See the programming unit manufac-
turer's manual.
The load shedder is enabled
and has shut down heating on
the appliance.
Wait for load shedding to nish.
The appliance has not be
paired with the remote control
(the icon is not displayed
on the remote control screen).
Remove the batteries from the
remote control, wait a few seconds,
then replace the batteries and pro-
ceed with pairing (see chapter 4.1).
An open window detected
( icon ashes)
Turn off the window opening
detection function (see chapter 5.5,
parameter 1).
The LED is ashing yellow:
default.
Contact your installer.

76
40016512
77
11/2017
Problem Diagnosis Procedure
The appliance is not
working.
Your appliance is not
powered up.
Check your appliance is properly
connected and powered (see
chapter 2.2).
Your appliance is not turned
on.
Check the remote control is properly
turned on (see chapter 5.1).
Check the pilot wire unit is not
sending a load shedding stop order.
The appliance continues
to heat, even though a
window is open.
The “Window detection”
function is not activated.
Activate the function (see chapter
5.5, parameter 1).
The correct operating
conditions for the window
opening/closure detection
function have not been met.
See chapter 5.4
The appliance does
not start to heat again,
although a window has
been closed.
The correct operating
conditions for the window
opening/closure detection
function have not been met.
See chapter 5.4
The remote control does
not allow operations.
The remote control is
locked.
Disable key locking (see chapter
5.1).
Communication problems
between remote control
and appliance.
Remote control and/or radio
frequency communication
problem.
Check the icon is present (paired
appliance).
Check that the LED changes colour
according to the commands sent.
Check your appliance is not control-
led by a pilot wire unit.
If checks are positive: remove the
control batteries for 10 minutes then
replace the batteries.
Pairing has been lost fol-
lowing a power failure.
The remote control and the
appliance have to be reset.
• Reset the remote control in the
advanced parameters (see chapter
5.5 parameter 9).
• Reset the appliance by pressing
10 seconds on the LED. The LED
ashes magenta quickly to conrm
the reset.
• After it is pressed, the LED returns
to xed magenta. Turn on the remote
control and start the pairing process.
Problem Diagnosis Procedure
The battery level indicator
on your remote control
is displayed.
Batteries drained. Change batteries (see chapter 8.3).
No display.
The remote control is off. Long press on .
The back-lighting on the
remote control screen is off.
Press a key to turn it on again.
The remote control screen
is on standby.
Press a key to turn it on again.
The time ashes. Time and date setting not
done.
Set time and date (see chapter 4.1).
The temperature setting
does not match the tem-
perature observed in the
room.
There is a discrepancy in
the measurement made by
the temperature probe.
Calibrate your remote control (see
chapter 5.3) to align the tempera-
ture measured in the room by the
appliance, and that measured by your
thermometer.
Remote control broken. Your appliance remains on
the last command received.
• Reset the appliance by pressing
10 seconds on the LED. The LED
ashes magenta quickly to conrm
the reset.
• Your appliance is waiting to be
paired and to start heating again.
PILOT WIRE
Problem Diagnosis Procedure
The appliance no longer
replies to commands from
the pilot wire.
The pilot wire is not
connected correctly.
Check the pilot wire connection (see
chapter 2.2).
Check the remote control is in
Comfort mode.
Your remote control is no
longer set to accept pilot
wire operation.
Activate the pilot wire function on
your remote control (see chapter 5.5,
parameter 3).
The room temperature
does not match the pre-
ferred temperature level
on the remote control.
The pilot wire may be
connected to a program-
ming control unit which
takes over from the remote
control (e.g.: sending an
Eco mode order from the
control unit, while the
control is set on Comfort).
Deactivate the pilot ware in advanced
parameters (see chapter 5.5 para-
meter 3) so that the remote control
continues to operate your appliance.
Table of contents