manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bloomfield
  6. •
  7. Kitchen Appliance
  8. •
  9. Bloomfield Reily 8740LZ User manual

Bloomfield Reily 8740LZ User manual

Other Bloomfield Kitchen Appliance manuals

Bloomfield 8740 User manual

Bloomfield

Bloomfield 8740 User manual

Bloomfield 8742 Series User manual

Bloomfield

Bloomfield 8742 Series User manual

Bloomfield PW-106 User manual

Bloomfield

Bloomfield PW-106 User manual

Bloomfield Integrity 8746 User manual

Bloomfield

Bloomfield Integrity 8746 User manual

Bloomfield H-115 User manual

Bloomfield

Bloomfield H-115 User manual

Bloomfield 2030 User manual

Bloomfield

Bloomfield 2030 User manual

Bloomfield 8740 User manual

Bloomfield

Bloomfield 8740 User manual

Bloomfield 8748 Series Guide

Bloomfield

Bloomfield 8748 Series Guide

Bloomfield 7895T User manual

Bloomfield

Bloomfield 7895T User manual

Bloomfield 8740 User manual

Bloomfield

Bloomfield 8740 User manual

Bloomfield PW-106 User manual

Bloomfield

Bloomfield PW-106 User manual

Popular Kitchen Appliance manuals by other brands

Tayama TYG-35AF instruction manual

Tayama

Tayama TYG-35AF instruction manual

AEG 43172V-MN user manual

AEG

AEG 43172V-MN user manual

REBER Professional 40 Use and maintenance

REBER

REBER Professional 40 Use and maintenance

North American BB12482G / TR-F-04-B-NCT-1 Assembly and operating instructions

North American

North American BB12482G / TR-F-04-B-NCT-1 Assembly and operating instructions

Presto fountain popper instruction manual

Presto

Presto fountain popper instruction manual

Westmark 1035 2260 operating instructions

Westmark

Westmark 1035 2260 operating instructions

Zanussi ZCG64396XA user manual

Zanussi

Zanussi ZCG64396XA user manual

HOFFEN SM-9302M instruction manual

HOFFEN

HOFFEN SM-9302M instruction manual

Philips HD3133 user manual

Philips

Philips HD3133 user manual

Ronco Beef Jerky User guide and recipes

Ronco

Ronco Beef Jerky User guide and recipes

Hendi 470411 user manual

Hendi

Hendi 470411 user manual

Livoo MEN386 user manual

Livoo

Livoo MEN386 user manual

croydon WR-10313-700 instruction manual

croydon

croydon WR-10313-700 instruction manual

Chefman RJ43-SQ Series user guide

Chefman

Chefman RJ43-SQ Series user guide

Vacmaster VP680 user guide

Vacmaster

Vacmaster VP680 user guide

Jetmaster 900HG operating instructions

Jetmaster

Jetmaster 900HG operating instructions

Küppersbusch EEH 610.0 Instructions for use and installation instructions

Küppersbusch

Küppersbusch EEH 610.0 Instructions for use and installation instructions

HURAKAN HKN-F10 manual

HURAKAN

HURAKAN HKN-F10 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

p/n 76466 Rev. B ECN-12589 M608R 111303 cps
608R
OWNERS MANUAL
for
MODEL
8740LZ
ICED TEA
BREWING SYSTEM
Includes:
Installation
Operation
Use & Care
Servicing Instructions
Model 8740LZ Brewer
NOTE: For your protection, please note that equipment in
this shipment was carefully inspected and packaged by
skilled personnel before leaving the factory.
Upon acceptance of this shipment, the transportation
company assumes full responsibility for its safe delivery.
IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any
visible loss or damage is noted on the freight bill
or express receipt, and that the note of loss or damage
is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY:
Regardless of the extent of the damage.
3. CONCEALED LOSS OR DAMAGE: if damage is
unnoticed until the merchandise is unpacked, notify the
transportation company or carrier immediately, and file
“CONCEALED DAMAGE” claim with them. This
must be done within fifteen (15) days from the date the
delivery was made to you. Be sure to retain the
container for inspection.
Bloomfield Industries cannot assume liability for damage or
loss incurred in transit. We will, however, at your request,
supply you with the necessary documents to support your
claim.
WARRANTY STATEMENT
SERVICE POLICY AND PROCEDURE GUIDE
ADDITIONAL WARRANTY EXCLUSIONS
SHIPPING DAMAGE CLAIMS PROCEDURE
1. Resetting of safety thermostats, circuit breakers,
overload protectors, or fuse replacements unless
warranted conditions are the cause.
2. All problems due to operation at voltages other than
specified on equipment nameplates; conversion to
correct voltage must be the customer’s responsibility.
3. All problems due to electrical connections not made in
accordance with electrical code requirements and
wiring diagrams supplied with the equipment.
4. Replacement of items subject to normal wear, to include
such items as knobs and light bulbs. Normal maintenance
functions including adjustment of thermostats, microswitches,
and replacement of fuses and indicating lights are not
covered under warranty.
5. All problems due to inadequate water supply, such as
fluctuating, or high or low water pressure.
6. All problems due to mineral/calcium deposits, or
contamination from chlorides/chlorines. De-liming is
considered a preventative maintenance function and is
not covered by warranty.
All electrical equipment manufactured by BLOOMFIELD
INDUSTRIES is warranted against defects in materials and
workmanship for a period of one year from the date of original
installation or eighteen (18) months from the date of shipment
from our factory, whichever comes first, and is for the benefit
of the original purchaser, except that:
a. airpots carry a 30 day parts warranty only.
b. dispensers; i.e., tea and coffee carry a 90 days parts
warranty only, excludes decanters.
THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN
LIEU OF ANY OTHER WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, WHICH ARE HEREBY EXCLUDED.
BLOOMFIELD INDUSTRIES DIVISION / SPECIALTY
EQUIPMENT MANUFACTURING CORPORATION SHALL
NOT BE LIABLE FOR INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES FROM ANY
CAUSE WHATSOEVER.
This warranty is void if it is determined that upon inspection by
an Authorized Service Agency that the equipment has been
modified, misused, misapplied, improperly installed, or
damaged in transit or by fire, flood or act of God.
It also does not apply if the serial nameplate has been
removed or unauthorized service personnel perform service.
The prices charged by Bloomfield Industries for its products
are based upon the limitations in this warranty. Seller’s
obligation under this warranty is limited to the repair of defects
without charge by a Bloomfield Industries Authorized Service
Agency or one of its sub-agencies. This service will be
provided on customer’s premises for non-portable models.
Portable models (a device with a cord and plug) must be
taken or shipped to the closest Authorized Service Agency,
transportation charges prepaid, for services.
In addition to restrictions contained in this warranty, specific
limitations are shown below (Additional Warranty Exclusions).
Bloomfield Industries Authorized Service Agencies are located
in principal cities.
This warranty is valid in the United States and void elsewhere.
Please consult your classified telephone directory or your food
service equipment dealer; or, for information and other details
concerning warranty, write to:
Service Parts Department
Bloomfield Industries
P.O. Box 280
Verdi, NV 89439
Phone: (775) 689-5700 Fax: (888) 492-2783
7. Full use, care and maintenance instructions are supplied
with each machine. Those miscellaneous adjustments
noted are customer responsibility. Proper attention will
prolong the life of the machine.
8. Travel mileage is limited to sixty (60) miles from an
authorized Service Agency or one of its sub-agencies.
9. All labor shall be performed during normal working hours.
Overtime premium shall be charged to the customer.
10. All genuine Bloomfield replacement parts are warranted
for ninety (90) days from date of purchase on non-
warranted equipment. Any use of non-genuine
Bloomfield parts completely voids any warranty.
11. Installation, labor and job check-out are not considered
warranty.
12. Charges incurred by delays, waiting time or operating
restrictions that hinder the service technicians ability
to perform services are not covered by warranty.
This includes institutional and correctional facilities.
xi
MODEL DIMENSIONS VOLTS WATTS AMPS
1ø
POWER SUPPLY
CORD
8740LZ
3 - 5 Gallon
Iced Tea
Brewer
34-1/4" high
11-1/4" wide
19-27/32" deep
120 1515 13 NEMA 5-15P
1
TABLE OF CONTENTS
SPECIFICATIONS
Thank You for purchasing this Bloomfield Industries appliance.
Proper installation, professional operation and consistent
maintenance of this appliance will ensure that it gives you the very best performance and a long,
economical service life.
This manual contains the information needed to properly install this appliance, and to use, care for and
maintain or repair the appliance in a manner which will ensure its optimum performance.
WARRANTY STATEMENT xi
SPECIFICATIONS 1
FEATURES & OPERATING CONTROLS 2
PRECAUTIONS & GENERAL INFORMATION 3
AGENCY LISTING INFORMATION 3
INSTALLATION INSTRUCTIONS 4
OPERATION 6
BREWING TEA 8
CLEANING INSTRUCTIONS 9
TROUBLESHOOTING SUGGESTIONS 10
SERVICING INSTRUCTIONS 11
Deliming Instructions 15
EXPLODED VIEW & PARTS LIST 16
WIRING DIAGRAMS 19
APPLICABILITY
This manual applies to the following Bloomfield Industries product:
8740LZ 3 - 5 Gallon Tea Brewer
INTRODUCTION
FEATURES AND OPERATING CONTROLS
2
Fig. 1 Model 8740 Features and Operating Controls
PRECAUTIONS AND GENERAL INFORMATION
3
WARNING: Electric Shock Hazard
All servicing requiring access to non-insulated components must be performed by qualified
service personnel. Do not open any access panels which require the use of tools. Failure to
heed this warning can result in electrical shock.
WARNING: Injury Hazard
All installation procedures must be performed by qualified personnel with full knowledge of all
applicable electrical and plumbing codes. Failure could result in property damage and
personal injury.
WARNING Electric Shock Hazard
Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a
plumbing line will provide such a ground. Electrical shock will cause death or serious Injury.
WARNING: Burn Hazard
This appliance dispenses very hot liquid. Serious bodily injury from scalding can occur from
contact with dispensed liquids.
This appliance is intended for commercial use only.
This appliance is intended for use to brew beverage products for
human consumption. No other use is recommended or
authorized by the manufacturer or its agents.
This appliance is intended for use in commercial establishments,
where all operators are familiar with the appliance use,
limitations and associated hazards. Operating instructions and
warnings must be read and understood by all operators and
users.
Except as noted, this piece of equipment is made in the USA
and has American sizes on hardware. All metric conversions
are approximate and can vary in size.
The following trouble shooting, component views and parts lists
are included for general reference, and are intended for use by
qualified service personnel.
This manual should be considered a permanent part of this
appliance. The manual must remain with the appliance if it is
sold or moved to another location.
This brewer is and listed under UL file E9253.
This brewer meets Standard 4 only when installed,
operated and maintained in accordance with the enclosed
instructions.
CAUTION: Equipment
Electrical Damage
DO NOT plug in or energize this
appliance until all Installation
Instructions are read and followed.
Damage to the Brewer will occur if
these instructions are not followed.
CAUTION:
Burn Hazard
Exposed surfaces of the
appliance, brew chamber and
dispenser may be HOT to the
touch, and can cause serious
burns.
STD 4
AGENCY LISTING INFORMATION
E9253 E9253
INSTALLATION
4
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
Unpack the unit. Inspect all components for completeness and
condition. Ensure that all packing materials have been removed
from the unit.
Verify that the Spray Head Gasket and Spray Disk are properly
installed.
PLUMBER’S INSTALLATION INSTRUCTIONS
Brewer must be connected to a POTABLE WATER, COLD
WATER line. Flush water line before connecting to Brewer.
DO NOT use a saddle valve with a self-piercing tap for the water
line connection. Such a tap can become restricted by waterline
debris. For systems that must use a saddle tap, shut off the main
water supply and drill a 3/16” (minimum) tap for the saddle
connection, in order to insure an ample water supply. Remember
to flush the line prior to installing the saddle.
The brewer must be installed on a water line with average
pressure between 20 PSI and 90 PSI. If your water pressure
exceeds 90 PSI at anytime, a pressure regulator must be
installed in the water supply line to limit the pressure to not more
than 90 PSI in order to avoid damage to lines and solenoid.
A water shut-off valve should be installed on the incoming water
line in a convenient location (Use a low restriction type valve,
such as a 1/4-turn ball valve, to avoid loss of water flow thru the
valve.
NSF requires that the brewer be able to be moved for cleaning
underneath. A flex line or loops of copper tubing will satisfy this
requirement. See Figure 2 below.
IMPORTANT:
To enable the installer to make
a quality installation and to
minimize installation time, the
following suggestions and tests
should be done before the
actual unit installation is started:
CAUTION:
EQUIPMENT DAMAGE
DO NOT plug in or energize this
appliance until all Installation
Instructions are read and
followed. Damage to the
Brewer will occur if these
instructions are not followed.
CAUTION:
UNSTABLE EQUIP-
MENT HAZARD
It is very important for safety
and for proper operation that the
brewer is level and stable when
standing in its final operating
position.
NOTE: Water supply inlet line
must meet certain minimum
criteria to insure successful
operation of the brewer.
Bloomfield recommends 1/4"
copper tubing for installation of
less than 12 feet and 3/8" for
more than 12 feet from a 1/2"
water supply line.
NOTE: This equipment must be
installed to comply with
applicable federal, state and
local plumbing codes and
ordinances.
Fig. 2 Water Supply Installation
INSTALLATION (continued)
5
WARNING
ELECTRIC SHOCK
HAZARD:
Brewer must be properly
grounded to prevent possible
shock hazard. DO NOT
assume a plumbing line will
provide such a ground.
Electrical shock will cause death
or serious injury.
IMPORTANT:
Supply power must match
nameplate for voltage and
phase. Connecting to the
wrong voltage will damage the
brewer or result in decreased
performance. Such damage is
not covered by warranty.
IMPORTANT: The ground
prong of the plug is part of a
system designed to protect you
from electrical shock in the
event of internal damage.
Never cut off the ground prong
nor twist a blade to fit an
existing receptacle.
Contact a licensed electrician
to install the proper circuit and
receptacle.
IMPORTANT: Do not connect
brewer to electrical power until
you are ready to fill the tank.
See instructions at left.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the Brewer to be installed.
IMPORTANT: Before connecting to electricity, make sure
automatic brewers are connected to the water supply.
Model 8740LZ is equipped with a cord and plug.
It requires a 115 - 125 volt 20 amp circuit (50/60 Hz, 2 wire plus
ground, with NEMA 5-15R receptacle).
PREPARATION
The water tank must be filler prior to operation. Slide an empty
brew chamber in place under the brew head. Place an empty
dispenser under the brew chamber.
Be sure the unit is connected to the water supply, the water
supply is turned ON and the "TANK HEATER SWITCH" is OFF.
Connect the unit to electric power.
Press the "START BREW" switch to initiate a brew cycle. The
solenoid will open and begin filling the tank. Initiate consecutive
brew cycles until water begins to flow from the brew head.
When all water stops dripping, discard all water generated.
Press the "TANK HEATER SWITCH" to ON. The heating
elements will begin heating the water in the tank. When the
"READY TO BREW" light glows the unit is ready for use.
NEMA 5-15R
RECEPTACLE
NEMA 5-15P
PLUG
GROUND
PIN
Fig. 3 Plug Configuration
OPERATION
Fig. 4 Brewer Operation Diagram
A. START-UP
For initial start-up, or if the brewer has not been used for an
extended period of time:
♦Be sure spray disk and brew gasket are properly installed in the
brew head.
♦ Be sure the water supply is properly connected and the water
supply valve is turned ON.
♦ Be sure the WATER TANK IS FILLED.
IMPORTANT: Fill the water tank before energizing this unit:
1. Insert the brew chamber (empty) and place an empty dispenser in
place under the brew chamber.
2. Be sure the TANK HEATER SWITCH is "OFF". Plug the unit into an
appropriate receptacle.
3. Press The BREW switch. Water will start filling the tank. Run
several consecutive brew cycles until water flows from the brew
chamber.
5. When water stops dripping from the brew chamber, empty the
dispenser, then press TANK HEAT switch "ON". The heating
element will begin heating water in the tank. When the water has
reached the proper brewing temperature, the “READY TO BREW”
light will glow.
IMPORTANT:
Tank must be full of water
before pressing TANK
HEATER SWITCH "ON".
Heating elements will be
damaged if allowed to
operate without being
fully submerged in water.
Damage caused by
operating the brewer
without water in the tank
is NOT COVERED BY
WARRANTY.
6
OPERATION (continued)
WATER HEATER
Water temperature is sensed by a thermobulb
inserted into the water tank. This temperature
signal is fed to the mechanical thermostat.
The temperature setpoint is adjustable. Heating
element is energized by the thermostat.
Excessive temperature will trip the hi-limit safety
switch. The hi-limit will automatically reset when
the brewer cools.
WATER FLOW
AUTOMATIC OPERATION
Pressing the BREW switch starts the timer, which
in turn energizes the solenoid valves. This allows
water from an external water supply to flow into
the water tank. The incoming water forces heated
water out of the tank to perform the brew.
Additionally, a measured amount of unheated
water is bypassed into the dispenser to dilute and
cool the brew.
The solenoid uses a flow control device so that
flow is consistent between 20 p.s.i. and 90 p.s.i.
The length of time the solenoid is open is
controlled by the timer setting.
Fig. 6 Water Flow Diagram
Fig. 5 Heat Control Diagram
7
BREWING TEA
8
A. PREPARATION
Place one (1) genuine Bloomfield
paper filter into the brew chamber.
Add an amount of fresh tea leaves
to the brew chamber appropriate
to the brew volume.
NOTE: the brewer can brew any
volume between 3 and 5 gallons,
and is factory set for a 3 gallons
brew volume. If other brew
volumes are desired, refer to
SOLENOID TIME ADJUSTMENT,
page 13.
Gently shake the brew chamber to level the bed of tea leaves.
Slide the brew chamber into place under the brew head.
B. AUTOMATIC OPERATION
BE sure “READY TO BREW” light is lit.
Place the appropriate EMPTY dispenser in place under the brew
chamber. If a brew-thru lid is used, be sure the bypass opening in
the lid is directly under the bypass nozzle.
Press the “BREW” switch. The brew solenoid will open for
an amount of time determined by the timer setting, admitting a
measured quantity of water into the tank.
Inlet water will displace a like amount of heated water from the tank.
The hot water will be forced into the brew head where it will spray
over the bed of grounds. Freshly brewed tea will begin to fill the
dispenser. Additionally, a measured amount of cold dilution water
will flow from the bypass nozzle into the dispenser.
When the flow and all dripping stops at the end of the brew cycle,
the tea is ready to serve.
Discard the contents of the brew chamber and rinse it in a sink.
When the ”READY TO BREW” light glows, the brewer is ready for
another brew cycle.
CAUTION:
Burn Hazard
Exposed surfaces of the
brewer, brew chamber and
dispenser may be HOT to
the touch, and can cause
serious burns.
CAUTION:
Burn Hazard
To avoid splashing or
overflowing hot liquids,
ALWAYS place an empty
dispenser under the brew
chamber before starting
the brew cycle. Failure to
comply can cause serious
burns.
CAUTION:
Burn Hazard
After a brew cycle, brew
chamber contents are
HOT. Remove the brew
chamber and dispose of
used tea leaves with care.
Failure to comply can
cause serious burns.
Fig. 7 Tea Brew Chamber