Contents
A - Reading guide and safety instructions 3
B-TechnicalData 5
C - Mechanical assembly of laser module 6
D - Electrical connection of laser module 8
E-Adjustinglaser 11
F-Troubleshooting 12
G-Electricalcircuitdiagram 13

3BA-117/1EA MZR.5300.01
• Please keep a copy of the operating instructions.
• Before starting work, please read the installation instructions and follow all safety instructions.
A.1 - How to use these operating instructions
A - Reading guide and safety instructions
A.2 - Safety instructions
• Work steps should only be carried out by a licensed electrician.
• Carefully read the operating instructions before laser module assembly.
• When using the MINIPRESS P or MINIDRILL P, the MINIPRESS P and MINIDRILL P operating instructions should be followed.
• When operating the laser module, please make sure that no one is within the projection area of the laser beam. Please also make
sure that unintentional, reflected beams (e.g. from reflective objects) can not intersect with any people in the area. Do not look
directly into the laser beam and never point it at a person. Lasers can cause eye and skin injuries. Never point the beam at mirrors
or reflective surfaces. Uncontrolled, diverted beams may hit a person. Only operate the laser in a monitored area. The laser module
is not intended for children. Trained personnel are required to monitor the operation of the laser module in schools, training facilities,
hobby and self-help workshops.
A.3 - Danger information
• The safety and danger information in the MINIPRESS P, MINIDRILL P operating instructions must be followed when starting up,
operating, retrofitting, servicing, repairing and dismantling the MINIPRESS P, MINIDRILL P.
Please familiarise yourself the following safety information
before staring any electrical work. Electrical work should only be
carried out by a licensed electrician.
No one should deviate from the following instructions even if this
should cause the work to be more difficult, more expensive or
take longer:
Any person working on MINIPRESS P, MINIDRILL P electrical
parts is responsible for following all local codes and therefore,
may be liable for any damages.
• Never work on components or control unit parts that are still
energised. Always disconnect electrical power from machine
and set the main switch to 0 before starting work.
• Follow all LOCKOUT / TAGOUT procedures established by
management
• Always use a voltage tester to ensure that components as well
as control unit components are not energised before starting
work.

4BA-117/1EA MZR.5300.01
• The intended purpose of laser module MZR.5300 is measurement and position determination on the work piece in conjunction with
MINIPRESS P, MINIDRILL P. Only wood or particle board should be used as the work piece since they are non-reflective. Coated
and/or reflective work pieces may not be used. Laser module MZR.5300 may only be used in combination with MINIPRESS P,
MINIDRILL P in commercial and industrial applications. The manufacturer does not assume liability for uses not described in these
operating instructions or the MINIPRESS P, MINIDRILL P operating instructions.
A.4 - Intended use
Safety information:
This exclamation point indicates important safety information that must be followed.
Comment:
This exclamation point indicates a comment. If this comment is not followed, then assembly machine components
as well as the work piece itself may be damaged or the assembly machine may be rendered inoperable and/or the
work piece unusable.
A - Reading guide and safety instructions
• Never look directly into the laser beam. The laser can cause
eye damage
!

5BA-117/1EA MZR.5300.01
B - Technical data
B.2 - Technical data
• Length: 40 mm
• Diameter: 12 mm
• Diode power: 5 mW
• Operatind Distance: 250 mm
• Wavelength: 650 nm
• Operating voltage: 2.5 - 6 V DC
• Operating current: 30 mA
• Operating temperature: -10 - 40 °C
• Storage temperature: -40 - 80 °C
• Laser class: 2M
• Optics: acrylic lens
• Wirelength: 1510 mm
• Material of housing: aluminium
• Cable type: LifYY 2y 0.5 mm²
• fan angle: 90° or 60°
• line thickness: 0.5 mm @ 250 mm
• Potential of housing: VDD

6BA-117/1EA MZR.5300.01
C.1 - Standard components
C - Mechanical assembly of laser module
• Wrench DIN EN 911 SW 2 mm
• Wrench with “T“ handle DIN EN 911 SW 3 mm
• Sub-assembly MZR.5300.01
• Power supply unit
• 1 screw DIN 912 M 4x16 (ASTM F 912M:2004 )
• Cable clips
• Label
C.2 - MINIPRESS P preparation
ATTENTION:
The main switch does not disconnect the machine
from the air pressure system.
• Set main switch (3.1) to Pos.0
• Disconnect electrical and pneumatic connections from the machine
• Remove all inserted drill bits
ATTENTION:
gash injury.
3.1

7BA-117/1EA MZR.5300.01
C - Mechanical assembly of laser module
C.3 - Laser module assembly
• Insert mounting screw into the mounting hole on the backside
of gearbox housing and rotate the screw 2 turns clockwise
• Place the laser module on to the bolt slide to the right
• Temporarily tighten the screw using the allen key provided

8BA-117/1EA MZR.5300.01
D.1 - Safety instructions / Preparation of MINIPRESS P or MINIDRILL P and control unit
D - Electrical connection of laser module
D.2 - Retrofitting the control unit
ATTENTION:
The main switch does not disconnect the assembly machine
from the air pressure system.
• Set main switch (3.1) to Pos.0
• Disconnect electrical and pneumatic connections from the assembly machine.
• Remove the screws of the control unit housing using a scre-
wdriver.
• Turn the screws counter-clockwise
• Never work on components or control unit parts that are still
energised. Always disconnect electrical power from machine
and set the main switch to 0 before starting work
• Follow all LOCKOUT / TAGOUT procedures establishment by
management
• Always use a voltage tester to ensure that components as well
as control unit components are not energised before starting
work
D - Electrical connection of laser module
• Remove the control unit housing cover
3.1

9BA-117/1EA MZR.5300.01
D - Electrical connection of laser module
• Snap the transformer into place on the DIN rail
• Mount the cable bushing
• Set aside enough remaining cable up to the cable tie
• Thread the cable as shown
• Attach cable along the pneumatic lines using the cable ties • Feed the cable through the cable bushing
!

10 BA-117/1EA MZR.5300.01
eludom resal fo noitcennoc lacirtcelE - D
• Connect the prepared quick-fi x connections
• Connect the laser diode to the low voltage side of the power
supply unit
• Replace the cover on the control unit housing
• Turn the screws clockwise using a screwdriver
• Never work on components or control unit parts that are still
energised. Always pull the mains plug and set the main switch
to 0 before starting work
• Always use a voltage tester to ensure that components as well
as control unit components are not energised before starting
work
• Put the label on the machine
• Carry out the steps in chapter E

11 BA-117/1EA MZR.5300.01
E - Adjusting laser
• Never look directly into the laser beam. The laser can cause
eye damage
• We recommend that you use laser protection glasses (DIN
207) when adjusting the laser
ATTENTION:
All items except for the work piece should be removed from the work
area of the assembly machine. Keep your hands out of work area (A)
• Main switch (3.1) to pos. 1
• Laser line must be visible
E.1 - Adjusting laser to zero position
• Slightly loosen sub-assembly screw using a wrench (counter-
clockwise)
• Set laser line to the zero position
• Tighten screws using wrench (clockwise)
E.2 - Check the laser angle
• If laser angle is correct, all work steps are done. The machine
with the laser module is ready for work.
• If laser angle is wrong, carry out the steps in chapter F
A
3.2
3.1
4.8
2.7
3.3

12 BA-117/1EA MZR.5300.01
D - Electrical connection of laser module
F.2 - Laser beam is not perpendicular
F - Troubleshooting
F.1 - Adjusting the laser angle
• Loosen set screw using allen key (counter-clockwise)
• Turn laser diode until the correct angle is reached on the work
piece or ruler. Use a work piece for the alignment. Affix the
work piece to the work center using clamps
• Re-tighten set screw using allen key (clockwise)
Only carry out the following steps when the laser angle is not correct
Only carry out the following steps when the laser is not perpendicular
The laser beam is not perpendicular when it has moved from the zero position due to the stroke movement
• Loosen set screw using allen key (counter-clockwise)
• Move laser diode until the laser beam is perpendicular
• Re-tighten set screw using allen key (clockwise)
• Never look directly into the laser beam. The laser can cause
eye damage
• We recommend that you use laser protection glasses (DIN
207) when adjusting the laser

13 BA-117/1EA MZR.5300.01
D - Electrical connection of laser module
G - Diagrams
G.1 - Electrical diagram
135
246
13
14
K1
A1
A2
S1 690V IEC, 600V UL/CSA 4552380
F1 250V, dm5x20mm, 1.6AT 1788700
1S2 250V/6A, G1/4" 3988890
1 230VAC 2456160
K1 400V (max.690V), 12A 2456300
M1 1,1kW, 220V/60 z 3244009
C 25µF, 400VDB 2649801 1
2
4
1S2 P
0V 220V~
0V3,6V
-+
T1 NL
POTENTIOMETER
brown
blue
F1 T1,6A
PE
N
L1 white
black
PE green
V2
U1 W2
W1
V1 U2
1
X1
X2
1~ M1
1x220V 60 z
S6-60%ED
7,3A, 1,1kW, 3325/min
C 25µF 400VDB
C
1
3
5
2
4
6
S1
78