BNC SAM 940+ User manual

April 8, 2020
[SAM IV APPLICATION SW MANUAL VER 1.71]
Berkeley Nucleonics Corporation
info@berkeleynucleonics.com | www.berkeleynucleonics.com | 2955 Kerner Blvd, San Rafael, CA 94901 | 800-234-7858
1
U S E R M A N UA L
MODEL SAM 940+
B E R K E L E Y N U C L E O N I C S C O R P O R A T I O N

[SAM IV APPLICATION SW MANUAL VER 1.71]
April 8, 2020
2
Berkeley Nucleonics Corporation
info@berkeleynucleonics.com | www.berkeleynucleonics.com | 2955 Kerner Blvd, San Rafael, CA 94901 | 800-234-7858
USER MANUAL
MODEL SAM 940+
Table of Contents
Chapter 1. Introduction..............................................................................................................3
1.1 SAM 940+ Evolution .............................................................................................................................. 4
1.2 Important safety information.................................................................................................................. 5
1.3 Product Warranty...................................................................................................................................... 5
1.4 Notification of copyright......................................................................................................................... 5
Chapter 2. Safety .......................................................................................................................6
2.1 Cautions and notes ................................................................................................................................... 6
2.2 Classification.............................................................................................................................................. 7
2.3 Labels .......................................................................................................................................................... 7
Chapter 3. System Description .................................................................................................8
3.1 System components.................................................................................................................................. 8
3.2 High resolution camera.......................................................................................................................... 10
3.3 Belt holster and hand strap.................................................................................................................... 10
3.4 Power and battery charge guide............................................................................................................ 11
3.5 SAM 940+ connectivity......................................................................................................................... 15
3.6 SAM 940+ Software............................................................................................................................... 15
3.7 Prerequisites for the operation of the SAM 940+............................................................................. 16
Chapter 4. PeakAbout IV ........................................................................................................ 18
4.1 Introduction............................................................................................................................................. 18
4.2 Function buttons..................................................................................................................................... 19
4.3 Gauge Screen........................................................................................................................................... 20
4.4 Menu hierarchy........................................................................................................................................ 20
Chapter 5. Basic Operating instruction .................................................................................. 22
5.1 Prepare the SAM 940+ for operation.................................................................................................. 22
5.2 Auto calibration....................................................................................................................................... 23
5.3 Perform background measurement...................................................................................................... 23
5.4 Begin monitoring radiation.................................................................................................................... 25
5.5 When the SAM 940+ has alarmed....................................................................................................... 26
5.6 Perform manual ID ................................................................................................................................ 27
5.7 Transmit event data to reach-back....................................................................................................... 33

April 8, 2020
[SAM IV APPLICATION SW MANUAL VER 1.71]
Berkeley Nucleonics Corporation
info@berkeleynucleonics.com | www.berkeleynucleonics.com | 2955 Kerner Blvd, San Rafael, CA 94901 | 800-234-7858
3
5.8 Attach photo immediately after an event............................................................................................ 35
5.9 Find directional information of isotope.............................................................................................. 35
5.10 Favorite Event....................................................................................................................................... 38
5.10 Sleep mode and turn off after operation........................................................................................... 39
Chapter 6. Operating Instruction: Event log and Setup menus ............................................. 40
6.1 Use the event log to access event data ................................................................................................ 40
6.2 Use the event log to transmit event data to reach back.................................................................... 41
6.3 Use the setup menu for user setting .................................................................................................... 42
Chapter 7. PeakID IV .............................................................................................................50
7.1 Downloading PeakID IV....................................................................................................................... 50
7.2 Installing PeakID IV............................................................................................................................... 51
7.3 Connecting SAM 940+ and PC............................................................................................................ 52
7.4 Navigating the PeakID IV GUI and Structure .................................................................................. 56
7.5 Spectrum Manipulation.......................................................................................................................... 57
7.6 PeakID IV Configuration...................................................................................................................... 58
7.7 Data Analysis Menu GUI ...................................................................................................................... 62
7.8 Event Log Menu GUI............................................................................................................................ 71
7.9 Configuration Menu GUI...................................................................................................................... 78
Chapter 8. Reminder and useful tips ...................................................................................... 90
Appendix: Specifications ......................................................................................................... 91

[SAM IV APPLICATION SW MANUAL VER 1.71]
April 8, 2020
4
Berkeley Nucleonics Corporation
info@berkeleynucleonics.com | www.berkeleynucleonics.com | 2955 Kerner Blvd, San Rafael, CA 94901 | 800-234-7858
CHAPTER 1. INTRODUCTION
The new, third generation, SAM 940+, meets the increasing demand for portability with a lightweight (1.2 Kg)
unit that sacrifices neither speed nor quality of radionuclide identification. It is also designed to meet the
requirements of ANSI 42.34 criteria for hand-held instruments.
BNC’s decades long experience in innovative RIID design drives a RIID that leverages the most advanced
technologies available to deliver features such as: (a) source-less auto-stabilization; (b) real time reach-back; (c)
detachable external probes. Features such as high-resolution camera, multi-channel GPS, Gyro sensor, and a
hot swappable battery pack complete a state-of-the-art unit.
The features of this new design assure the user of excellent performance that exceeds the demanding
requirements of Homeland Security in the USA and beyond.
Figure 1.1.0. SAM 940+
1.1. SAM 940+ EVOLUTION
The 3rd generation SAM 940+ is the most compact and lightweight hand-held RIID product ever produced.
Volume and weight are a third less than previous models and yet advanced features such as multi-media support
are included.
Figure 1.1.1. The 3rd generation hand-held RIID and its evolution

April 8, 2020
[SAM IV APPLICATION SW MANUAL VER 1.71]
Berkeley Nucleonics Corporation
info@berkeleynucleonics.com | www.berkeleynucleonics.com | 2955 Kerner Blvd, San Rafael, CA 94901 | 800-234-7858
5
1.2. IMPORTANT SAFETY INFORMATION
The SAM 940+ has been meticulously engineered to provide safe, dependable, high performance for years. As
with any kind of electrical equipment, following instructions and taking basic precautions will prevent harm to
the operator and to the equipment.
Prior to using this equipment, you should:
✓Read and understand this manual thoroughly, especially the chapter on safety (Chapter 2).
✓Read and understand thoroughly all warning labels on the equipment.
✓Store all documents provided with the equipment in a safe place for future reference.
1.3. PRODUCT WARRANTY
Description of the BNC. warranty for the SAM 940+ handheld RIID systems:
✓The unit is warranted to be free of defects in material and workmanship, including: parts, labor and all
unit elements.
✓Unless otherwise indicated, the warranty is good for 12 months after delivery to the original buyer
only.
1.4. NOTIFICATION OF COPYRIGHT
The software in this device is protected by copyright laws and international treaty. You must treat the software
like any other copyrighted material. Copyright laws prohibit making additional copies of the software for any
reason other than specifically described in this manual. You may not copy the written materials accompanying
the product without prior written consent from BNC.

[SAM IV APPLICATION SW MANUAL VER 1.71]
April 8, 2020
6
Berkeley Nucleonics Corporation
info@berkeleynucleonics.com | www.berkeleynucleonics.com | 2955 Kerner Blvd, San Rafael, CA 94901 | 800-234-7858
CHAPTER 2. SAFETY
2.1. CAUTIONS AND NOTES
The following warnings and instructions are vital to the optimal operation of the SAM 940+ unit and should
be made readily accessible for reference. Follow these warnings and instructions thoroughly to use the unit
correctly and to protect the safety of the users.
Handling Instructions:
✓The maintenance service of the unit should only be handled by qualified/trained personnel
✓Cleaning the Camera and Flash lamp Windows: clean the windows with a soft, moist cloth to keep
them clean and clear. Turn off the power before cleaning.
Safety Hazard Warnings:
✓It can be very hazardous to open the unit on account of high voltage inside the unit (high voltage in
the detector is up to 1000 Volts). Be sure to refer all servicing to qualified/trained personnel.
Disposal Instructions:
✓If/when disposing the unit: observe local and national regulations for the disposal of units containing
a lithium battery.
✓Do not use household of municipal waste collection services for disposal of electrical and electronic
equipment. EU countries require the use of separate recycling collection services.
WARNING:
✓External equipment intended for connection to signal input, signal output or other connectors, shall
comply with relevant EN Standard (e.g., EN 61326-1:2013, EN 301 489-1 V1.9.2 and EN 301 489-17
V2.2.1).
✓If, in doubt, contact qualified technician or your local representative.
SAM940+ CONTAINS FCC ID : U8D-FB155BC
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operations.

[SAM IV APPLICATION SW MANUAL VER 1.71]
April 8, 2020
7
Berkeley Nucleonics Corporation
info@berkeleynucleonics.com | www.berkeleynucleonics.com | 2955 Kerner Blvd, San Rafael, CA 94901 | 800-234-7858
Please contact Berkeley Nucleonics for the full User Manual
Berkeley Nucleonics Corporation
[email protected]|www.berkeleynucleonics.com|800-234-7858
2955 Kerner Blvd, San Rafael, CA 94901
Table of contents
Other BNC Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Sonel
Sonel CMP-200 operating manual

barfield
barfield BT-700 Series quick start guide

Cirrus Research
Cirrus Research Dosebadge 5 user manual

Computech Systems
Computech Systems EGT Plus 4100 Series manual

ADA INSTRUMENTS
ADA INSTRUMENTS DigiTeo-2 operating manual

PCE Instruments
PCE Instruments PCE-CT 21BT user manual