Bogen NQ-E7010 User manual

Input/Output Controller
Configuration Guide
NQ-E7010
© 2021 Bogen Communications, Inc.
All rights reserved.
740-00017G
211115

i
Contents
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i
Configuring the Nyquist Input/Output Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Using the Dashboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Updating Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Network Settings Tab Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Configuration Settings Tab Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Accessing Log Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

1
Configuring the Nyquist Input/Output
Controller
The NQ-E7010 Input/Output (I/O) Controller allows Nyquist to recognize third-party
switch contact closures and to provide external circuits. Configuration rules can be set for
each input and output port on this appliance. For example, you can set a rule that if a
contact is opened, then an alarm will sound.
Contact closures can be set for specific dates and times using the Configure Schedule
button on the I/O Controller’s Edit Station page. For example, suppose you want to
schedule an output that unlocks a door at 7:30 each weekday morning. You can set up an
output contact closure schedule for 7:30 a.m. Monday through Friday. When the Activity
Time occurs, the contact is closed, which in turn triggers a third-party contact switch that
closes the door.
The Nyquist server can automatically discover and configure the I/O Controller, but you
can also manage the device, and manually configure some settings, through the I/O Con-
troller’s web-based user interface (web UI).
A short press of the appliance’s Reset button reboots the device. If you press the Reset
button for 10 seconds, the appliance returns to the factory default configuration settings.
Returning to the default configuration settings does not change the appliance’s firmware.
The following sections describe settings and configurations that can be applied to this device
which are not controlled by the Nyquist server. For information about using Nyquist’s auto-
matic configuration process, refer to the Nyquist System Administrator Guide.
To access the appliance’s UI:
1Access the appliance’s web UI by doing one of the following:
a) On your web browser, enter the IP address for the appliance as the URL.
b) From the Nyquist web UI navigation bar, select Stations, select Stations Status,
navigate to the device that you want to configure, and then select the Link icon.
Note: Do not use third-party Chrome browser extensions with the Nyquist user interface.

2
2At the Nyquist Appliance Login page, enter username and password, and then select
Login.
The default username is admin; the default password is bogen.
The dashboard for the selected appliance appears.
Figure 1. Nyquist Appliance Login
Figure 2. I/O Controller Dashboard

3
Using the Dashboard
The dashboard displays the following fields:
The following buttons are available at the top of all pages in the application.
Table 1. Appliance Dashboard Fields
Device Type Identifies the model of this device.
Serial Number Identifies the serial number for the device.
MAC Address Specifies the Media Access Control (MAC) address,
which is a unique identifier assigned to network inter-
faces for communications on the physical network seg-
ment.
Firmware Version Provides the firmware version installed on the station.
Table 2. Appliance Dashboard Buttons
Dashboard Displays the dashboard.
Configuration Settings Accesses the Configuration Settings page where you can
view various options or select to receive configuration
settings from a Nyquist server.
Network Settings Accesses the Network Settings page where you can view
and set network settings, such as the static IP address.
Firmware Update Accesses the Firmware Update page where you can view
the current Nyquist version, update firmware to a new
version, restore the configuration to factory defaults,
and reboot the appliance.
Logs Accesses log files, which record either events or mes-
sages that occur when software runs and are used when
troubleshooting the appliance.
Help Accesses the appliance’s online help.
Manual Displays the appliance’s configuration manual.
Logout Logs out of the appliance’s dashboard.

4
Updating Firmware
When you select Firmware Update from the appliance’s web UI, the Firmware Update
page appears. From this page you can determine which Nyquist firmware version the
appliance is using and if an update is available. You can also load a firmware release,
install the loaded firmware, restore the configuration to factory defaults, and reboot the
appliance.
To use the Firmware Update page:
1On the appliance web UI’s main page, select Firmware Update to view or update the
firmware version.
2If you already have a firmware file you would like to install to the appliance, select
Upload Firmware to upload the firmware file from your computer to the appliance. A
popup screen appears that allows you to select the file that you want to upload. You
can navigate to the file’s location. After you select the file, select Upload.
3The page displays the uploaded firmware version (“New Nyquist Version”) and an
Update Firmware button appears. Select this button if you want to update the appli-
ance’s firmware to the uploaded version.
Note: A Nyquist appliance connected to the Nyquist network receives a configuration
file from the Nyquist server that includes the latest firmware available from the server.
If the firmware is different from the one installed on the appliance, an automatic firm-
ware update occurs unless the Firmware parameter for the station is left blank. Refer to
the Nyquist System Administrator Guide for more information.
Figure 3. Firmware Update Page

5
4If you want to return your appliance to its original factory configuration, select
Restore Factory Settings.
5Select Reboot Appliance to restart your appliance.
Network Settings Tab Parameters
Network settings can be configured dynamically by the Nyquist server or manually by
using the appliance’s web UI.
To manually configure network settings:
1On the appliance web UI’s main page, select Network Settings.
2Select your desired network settings.
3Select Save.
Table 3. Firmware Update settings
Current Nyquist Version Shows the version of the appliance’s currently
installed firmware.
New Nyquist Version Shows the version of the firmware that has been
loaded, though not installed, onto the appliance.
Update Firmware Available only when a new firmware version has
been loaded onto the appliance (as specified in
New Nyquist Version).
Installs the loaded firmware. A reboot may be
required after installation.
Upload Firmware Prompts the user to specify a firmware file, which
will then be loaded (though not installed) onto the
appliance.
Note: To obtain the firmware file for a specific ver-
sion, please contact Bogen Customer Service.
Restore Factory Settings Returns the appliance to its original factory con-
figuration.
Note: This does not install the original appliance
firmware. The firmware will not be changed.
Reboot Appliance Restarts the appliance.

6
Network settings are described in the following table:
Figure 4. Network Settings
Table 4. Network Settings
IP Address Identifies the IP address assigned to the appliance.
Netmask Identifies the subnetwork subdivision of an IP net-
work.
Gateway Identifies the address, or route, for the default gate-
way.
VLAN ID Identifies the Virtual Local Area Network (VLAN) for
this appliance. Values range from 0 to 4094.
VLAN Priority Identifies the priority of the network traffic on the
VLAN. Priority can range from 0 through 7.
NTP Server Identifies the IP address or the domain name of the
Network Time Protocol (NTP) Server.

7
Configuration Settings Tab Parameters
The way to configure Nyquist appliances is to obtain configuration settings from the
Nyquist server by selecting Get Configuration From Server.
TFTP Server Identifies the host name or IP address of the Trivial
File Transfer Protocol (TFTP) server.
The specified TFTP server can be used to automati-
cally set this device’s Configuration settings via the
Get Configuration from Server button.
If TFTP Server from DHCP (see below) is set to “Yes”,
this value will be auto-configured via DHCP option
66, assuming the DHCP server has been configured
to provide option 66. For details, see the documenta-
tion for your DHCP server.
Note: A TFTP server runs on the Nyquist server on
port 69 (the standard TFTP port) and the optional
Nyquist DHCP service automatically provides this
TFTP address via option 66.
If this value is unspecified, the TFTP Server from
DHCP will automatically be set to “Yes”, this field will
become read-only, and DHCP will be used to config-
ure this setting. To change this value, the TFTP Server
from DHCP setting must be set to No, which makes
the field editable.
TFTP Server from DHCP “Yes” means the device will use the DHCP option 66
value to retrieve an address for the TFTP Server from
DHCP.
“No” means the device will ignore the DHCP option
66 value and use the manually configured value of
the TFTP Server (see above).
DHCP Enabled Indicates if the device is enabled to use DHCP to
retrieve its IP configuration.
Reboot Appliance Indicates that this appliance should reboot when the
Save button is clicked.
Table 4. Network Settings (Continued)

8
To view the Nyquist appliance configuration:
1On the appliance Web UI’s main page, select Configuration Settings.
2View the configuration settings.
The following table describes the Configuration Settings tab settings:
The Configuration Settings tab also displays the following information for each Device
Station attached to the controller:
Figure 5. Appliance Configuration Settings
Table 5. Configuration Settings
Get Configuration from
Server
Retrieves configuration settings (i.e., web username,
server, and local port) from the TFTP server specified in
the Network Settings (see Table 1 on page 1).
Web Username Displays the username of the current user.
Port Number Shows the port number of the appliance.
Port Type Shows the device type to which the port connects.
Account ID Shows the SIP account (IP address) associated with the
device preceded by the extension of the device associ-
ated with this port.
Local Port Shows the port used for SIP.
Username Shows the username or extension for the station associ-
ated with the port.

9
Accessing Log Files
A log file records events and messages that occur when software runs, to be used when
troubleshooting the appliance. From the appliance’s web-based UI, log files can be
viewed directly or exported via download to your PC, Mac, or Android device, where they
can be copied to removable media or attached to an email for technical support.
To view a log file:
1On the appliance Web UI’s main page, select Logs.
2From the drop-down menu, select the log that you want to view.
Multiple versions of the same log, and zipped copies of the log, may be available.
3To export the file, select Export.
A link to a .txt file appears in the browser’s lower left corner.
Available logs are described in the following table. If a log file is empty, however, it will
not appear in the drop-down list of available logs.
Figure 6. Logs

10
Table 6. Logs
Log Description
ampws.log Contains information about protection status and logs
protection events with temperature information at the
time of event.
auth.log Contains system authorization information, including
user logins and authentication methods that were
used.
btmp Contains information about failed login attempts.
daemon.log Contains information logged by the various back-
ground daemons that run on the system.
debug Contains errors and debug information.
dpkg.log Contains information that is logged when a package is
installed or removed using dpkg command.
faillog Contains user failed login attempts.
kern.log Contains information logged by the kernel and recent
login information for all users.
lastlog Contains information on the last login of each user.
messages Contains messages generated by Nyquist.
php5-fpm.log Contains errors generated by the PHP script.
syslog Contains list of errors that occur when the server is run-
ning and server start and stop records
user.log Contains information about all user level logs.
wtmp Contains historical record of users logins at which ter-
minals, logouts, system events, and current status of
the system, and system boot time.