4Climate 5000 SCI – 6720887405 (2018/04)
Safety Precautions
2 Safety Precautions
Read Safety Precautions Before Installation
Incorrect installation due to ignoring instructions can cause serious
damage or injury.
The seriousness of potential damage or injuries is classified as either a
WARNING or CAUTION.
WARNING
Failure to observe a warning may result in serious injury. The
appliance must be installed in accordance with national regulations.
CAUTION
Failure to observe a caution may result in injury or equipment
damage.
WARNING
•Carefully read the safety precautions before installation.
•In certain functional environments, such as kitchens, server rooms,
etc., the use of specially designed air-conditioning units is highly
recommended.
•Only Qualified Personnel should install, repair and service this
air conditioning unit.
Improper installation may result in electrical shock, short circuit,
leaks, fire or other damage to the equipment and personal property.
•Strictly follow the installation instructions set forth in this
manual.
Improper installation may result in electrical shock, short circuit,
leaks, fire or other damage to the equipment.
•An all-pole disconnection device which has at least 3 mm clearances
in all poles and a leakage current that may exceed 10 mA, the resid-
ual current device (RCD) having a rated residual operating current
not exceeding 30 mA, and disconnection must be incorporated in
the fixed wiring in accordance with the wiring rules.
•Before you install the unit, consider strong winds, typhoons and
earthquakes that might affect your unit and locate it accordingly.
Failure to do so could cause the equipment to fail.
•After installation, ensure there are no refrigerant leaks and that the
unit is operating properly. The refrigerant is both toxic and flamma-
ble and poses a serious health and safety risk.
•Do not use means for accelerating the defrosting process or for
cleaning, other than those recommended by the manufacturer.
•The appliance must be stored so as to prevent mechanical damage
from occurring.
WARNING
•The appliance disconnection must be incorporated with an all-pole
disconnection device in the fixed wiring in accordance with the
wiring rules.
•Any person who is involved with working on or breaking a refrigerant
circuit should hold a currently valid certificate from an industry-ac-
credited assessment authority, which authorises their competence
to handle refrigerants safely in accordance with an industry rec-
ognised assessment specification.
•Servicing must only be performed by Qualified Personnel. Mainte-
nance and repair requiring the assistance of other skilled personnel
be carried out under the supervision of Qualified Personnel in the
use of flammable refrigerants.
•The appliance must be stored so as to prevent mechanical damage
from occurring.
•Keep ventilation openings clear of obstruction.
NOTE:
The following information is required for the units with R32 refrigerant.
•The appliance must be stored in a room without continuously oper-
ating ignition sources (for example: open flames, an operating gas
appliance or an operating electric heater).
•Do not pierce or burn.
•Be aware that the refrigerants may be odourless.
•Compliance with national gas regulations must be observed.
•The appliance must be stored in a well-ventilated area where the
room size corresponds to the room area as specified for operation.
•The appliance must be installed, operated and stored in a room with
a floor area larger than X m², installation of pipe-work must be kept
to a minimum X m² (please see the following form).
The appliance must not be installed in an unventilated space if that
space is smaller than X m² (please see the following form). Spaces
where refrigerant pipes are located must be compliant with national
gas regulations.
Model (Btu/h) Amount of
refrigerant to be
charged (kg)
Maximum
installation
height (m)
Minimum
room area
(m²)
≤30000 ≤2.048 2.2m 4
30000-48000 2.048-3.0 2.2m 4
>48000 >3.0 2.2m 5
Table 2.
Note about Fluorinated Gases
1. This air-conditioning unit contains fluorinated gases. For specific
information on the type of gas and the amount, please refer to the
relevant label on the unit itself.
2. Installation, service, maintenance and repair of this unit must be
performed by qualified personnel.
3. Product uninstallation and recycling must be performed by a
qualified personnel.
4. If the system has a leak-detection system installed, it must be
checked for leaks at least every 12 months.
5. When the unit is checked for leaks, proper record-keeping of all
checks is strongly recommended.