Mounting and Siting Notes for BPS242RF and BR1
1. Siting the Units
1.1 BPS242RF controller/transmitter and BR1 receiver
The units should be sited such that transmitted and received signals will be disturbed
as little as possible. For this reason, the following points should be observed with both
the BPS242RF and BR1
- Do not mount the units on metal surfaces
- Do not mount the units near electrical wires or electronic equipment such as PCs,
television sets, microwave equipment, etc.
- Do not mount the units in the vicinity of large metal structures or other construction
elements with fine metal meshes like special glass or special concrete
The distance between controller/transmitter and receiver should not exceed 20m or
two floors.
1.2 BPS242RF controller/transmitter
The controller/transmitter can either be wall mounted or free standing (using the stand
provided).
The BPS242RF should be located such that it can acquire the room temperature as
accurately as possible, without being affected by direct solar radiation or other heat or
refrigeration sources.
Mounting Instructions
The controller/transmitter can be wall mounted or table mounted with the clip on
stand provided.
1.3 BR1 receiver
Make certain that the mounting location is dry and protected from splash water.
The unit can be fitted to most commercially available recessed conduit boxes or
directly on the wall
2. Check wiring
All electrical connections must comply with current regulations.
BPS242RF
controller/transmitter
BR1
receiver
Conformity Declaration
Hereby Siemens declares that this Room Thermostat is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC.
Standards according to EN 60730
Automatic action Type 1.B
Degree of pollution 2
Rated impulse voltage 4000 V