DPX-620OPERATIONMANUAL
GENERAL
TECHNICALSPECIFICATIONS
Thismodelisa6channeldimmerpack,hasavarietyoffunctions,includingDMX,
ANALOGandMANUALcontrolmodes,Dimming,Preheatcontrol,overheatandoverlo-
adprotection,andDMX512addressallowingtosimultaneouslycontrol6channeloutput.
1.Powerinput:AC230V~50-60Hz()
AC220V~50-60Hz()
2.Poweroutput:10Aperchannelmax.Total60Amax.()
20Aperchannelmax.,Total120Amax.()
3.Fuse:20Acircuitbreaker
4.Dimensions:482x370x85mm
5.Weight:7.1Kg
3-phaseorsinglephaseinput
CE
CHINACECHINA
1.Channelindicator(x6)
Theseindicatorsareturnedonwithoutconnectingload,theyareturnedoffwhenloadiscon-
nected.
2.Circuitbreaker(x6)
Thiscircuitbreakerwillcutoffpowersupplyautomaticallywhenloadcurrentexceeds20A
3.Dipswitch
Theseswitchesaresettoselectinitialchannelsettingmode.
4.PREHEATcontrol
Thiscontroladjusttheinitiallightingpoint.
5.DMXindicator
6.Channeldimmerindicator(x6)
7.Channeldimmercontrol(x6)
Thesecontrolsadjustappropriatechanneldimmerlevel.
8.Powerswitch
9.Powerindicator
PRECAUTIONSBEFOREINSTALLING
1.Fittingconstructionofthisunitisasfollows:
2.Removewiringcover,connectwiresinaccordancewiththismanualorscreenprint
onthetopcover.
CONTROLSANDFUNCTIONS
FRONTPANEL
REARPANEL
Enclosure
Wiringenclosure
Wiringcover
CH2
CH3CH4
CH5CH6OFF
ON
CH1POWER
PREHEAT
CH1CH2CH3CH4CH5CH6
10
0
8
2
6
4
10
0
8
2
6
4
10
0
8
2
6
4
10
0
8
2
6
4
10
0
8
2
6
4
10
0
8
2
6
4
10
0
8
2
6
4
STARTADDRESS
DMXSIGNAL
25%
050%
INPARALLEL
1 2 3 4 5 87 1096
1
2
3
4 5 6
7 8
9
1 2 3 54
24-004-0028
R
1.DMXoutputsocket
UsetoconnecttoDMXinputsocketofnextunitforparallelcontrol.
2.DMXinputsocket
UsetoconnecttoDMXinputsignals.
3.ANALOGoutput(8-pindinsocket)
4.ANALOGinput(8-pindinsocket)
5.Outputwiringport(x5)
Usetoconnectto6channeloutput,10Aperchannelmax.,Total60Amax.()
20Aperchannelmax.,Total120Amax.()CE
CHINA
OPERATION
1.Pleaseconfirmpowerrequirementismatchedwiththatspecifiedonthisunit
2.Setupcorrectwireconnections.(seeconnectionsdiagram).
3.Applytorequiredcontrolsignals.
4.Checkforproperwireconnections,turnpowerswitchon.
5.Allowthesystemtoconnectavailablecontrolsignalsatatime,theprevailingoneshould
controlchanneloutput.IfPREHEATcontrolissettomaximum,channeldimmerlevelshould
be50percentofsettingmaximumdimmer.
6.ReceiveDMXsignals
Primarily,selectinitialchanneltoapplytoDMXsignals.
Setdipswitch10toON,thesystemshouldreceiveonlythefirstchannelDMXsignals
whichsynchronouslycontrol6channeloutput.
Setdipswitch10toOFF,thesystemshouldreceive6channelD MXsignalsandcontrol6
channeloutputinsequence,howDMXindicatorshouldturnon.
7.AppropriateinitialchannelDMXsettingmodeisreferedtofollowingtable:
.
.
.
8.Turnthepowerswitchoff,adjustchannelprogramsetting,andthenturnthepoweron.
9.Receive0-10Vpowerlevelsignals.
ThisunittransmitreceivedlevelsignalstoANALOGoutput,outputsupplyis+20VDC
600mAmax.
WARNING:
1.Thisapparatusmustbeearthed
2.Topreventfireorelectricshockhazard,donotexposethisapparatustorain
ormoisture.
3.Incasecircuitbreakeriscutoffautomatically,checkcorrespondingchannel
tofindwhetherthereisanymalfunction.
4.Toassureventilation,donotblockorstackgoodsneartoopenings.
5.Waitforatleast3secondstoturnonyourunitafteryouhaveturnedoffyourunit.
1 2 3 4 5 6 7 8 9 Initialchannel
0 0 0 0 0 0 0 0 0 0
1 0 0 0 0 0 0 0 0 1
0 1 0 0 0 0 0 0 0 2
1 1 0 0 0 0 0 0 0 3
0 0 1 0 0 0 0 0 0 4
1 1 1 1 1 1 1 1 0 255
0 0 0 0 0 0 0 0 1 256
1 0 0 0 0 0 0 0 1 257
1 1 1 1 1 1 1 1 1 511
LOADINGN
N
N
L
NN
CH6CH4CH2CH5CH3CH1E
LOADING
SINGLEPHASECONNECTION
CHINA
POWERINPUT:AC230V~50-60Hz
OUTPUT:10Aperchannel,Total60A
POWERINPUT:AC220V~50-60Hz
OUTPUT:20Aperchannel,Total120A
LOADINGN N
N
L1
L1
L2
L2
L3
L3
NN
CH6CH4CH2CH5CH3CH1E
LOADING
CHINA
POWERINPUT:AC230V~50-60Hz
OUTPUT:10Aperchannel,Total20Aperphase
POWERINPUT:AC220V~50-60Hz
OUTPUT:20Aperchannel,Total40Aperphase
THREE-PHASECONNECTION

Other Botex Dimmer manuals

Botex X-DiMMER-1 PRO User manual

Botex

Botex X-DiMMER-1 PRO User manual

Botex MPX-405 User manual

Botex

Botex MPX-405 User manual

Botex UP-2RF User manual

Botex

Botex UP-2RF User manual

Botex UP-1 User manual

Botex

Botex UP-1 User manual

Botex DPX-620III User manual

Botex

Botex DPX-620III User manual

Botex DPX-620III User manual

Botex

Botex DPX-620III User manual

Botex MPX-405 User manual

Botex

Botex MPX-405 User manual

Popular Dimmer manuals by other brands

Leviton Decora Illumatech IPI06-1L installation instructions

Leviton

Leviton Decora Illumatech IPI06-1L installation instructions

Domintell DimMax 380SLX instructions

Domintell

Domintell DimMax 380SLX instructions

LiteGear LiteDimmer manual

LiteGear

LiteGear LiteDimmer manual

American DJ DP-DMX4B User instructions

American DJ

American DJ DP-DMX4B User instructions

QUBINO ZMNHDD1 manual

QUBINO

QUBINO ZMNHDD1 manual

elsner elektronik RF-L-DST 1-10 V manual

elsner elektronik

elsner elektronik RF-L-DST 1-10 V manual

Chauvet DMX-4 user manual

Chauvet

Chauvet DMX-4 user manual

Dals BT06DIMLED-IC instructions

Dals

Dals BT06DIMLED-IC instructions

EcoDim ECO-DIM.07 WiFi manual

EcoDim

EcoDim ECO-DIM.07 WiFi manual

Sunricher SR-2304B manual

Sunricher

Sunricher SR-2304B manual

Miboxer TRI-C1WR manual

Miboxer

Miboxer TRI-C1WR manual

Leviton VZX10-1L installation instructions

Leviton

Leviton VZX10-1L installation instructions

Aeon Labs Aeotec Bypass user manual

Aeon Labs

Aeon Labs Aeotec Bypass user manual

SRS Lighting DP1 instruction manual

SRS Lighting

SRS Lighting DP1 instruction manual

Lightronics AS42L owner's manual

Lightronics

Lightronics AS42L owner's manual

AMX RDM-3FDB TRIPLE FDB MODULE Installation sheet

AMX

AMX RDM-3FDB TRIPLE FDB MODULE Installation sheet

Ltech LT-311RF manual

Ltech

Ltech LT-311RF manual

Niko 330-00701 manual

Niko

Niko 330-00701 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.