9. Rao / Target
Weight readout
10. ON/OFF buon
11. MODE buon
12. RATIO buon
13. “Target” rate bar
segments
14. “Actual” rate bar
segments
Charging the Baery
❶ Open the orange USB port cover at the back of the scale
and insert the small end of the USB cable in this port.
❷ Plug the USB cable into a USB compable outlet to charge
your scale’s baery.
❸ The scale will automacally turn on to verify the charging
connecon.
• Turning o the scale manually will reduce the
charging me.
• Scale is fully charged when the baery icon has
4 bars.
Our scale baery comes with protecon circuit to avoid
over-charging. We strongly recommend unplugging the
scale when it is fully charged.
Please charge the scale as soon as possible when the last
bar in the baery sign disappears, instead of waing ll
scale shuts o due to the power depleon.
READ THIS MANUAL PRIOR TO FIRST
USE AND SAVE FOR FUTURE REFERENCE
1-year Limited Warranty
Rao Scale Components General Maintenance and Care
• Avoid exposure to extreme heat or cold.
◦Always allow your scale to acclimate to normal room
temperature before use.
• Keep your scale in a clean environment.
◦Excessive dust, dirt, vibraon, air currents, as well as
close proximity to other electronic equipment may
have an adverse eect on the accuracy and reliability
of the scale.
• Handle the scale with care.
◦Gently set all items to be weighed on top of the
plaorm and center them.
◦Although this scale is designed to be quite durable,
avoid rough treatment as this may permanently
damage the internal components.
◦Always avoid violent shaking and dropping.
◦This is a precision instrument and should be handled
as such.
Specicaons and Funcons
• Capacity: 2000g
• Accuracy: 0.1g
• Units: grams (g), ounces (oz)
• Key funcons: ON/OFF, MODE, RATIO, UNIT, ZERO, TIMER
• Display: LCD with backlight
• Auto-o
◦Auto-o funcon is set to 180 seconds by default.
◦Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• Operang modes: Automac mode and Manual mode
• Power: (1) Rechargable baery
• Operaon temperature range: 50° to 85° Fahrenheit (10°
to 30° Celsius).
Mode Seng
❶ Turn on the scale by pressing the ON/OFF buon.
❷ Wait unl the LCD displays zero.
❸ Press the MODE buon;
• The display will read “ A ” (automac) or “ M ”
(manual) in the upper le of the LCD readout.
• Press MODE again to toggle between these
two modes.
Notes:
• The scale’s mode cannot be changed when weight is
on the plaorm or during the brewing process.
• The last mode used is retained when the scale is
turned o. Scale returns to the last mode used when
turned back on.
Operaon
Please note:
˗When removing weight from scale, do not apply downward
force or slide items o of the plaorm. Doing so may result
in inaccurate readings. Li items directly o of the plaorm.
˗Heat transfered from the brew vessel to the scale will alter
weight readings slightly. To minimize this, be sure to use the
silicone pad.
Turning Scale On:
❶ Press the ON/OFF buon once to power on the scale.
◦Wait for scale to zero before adding weight to
the plaorm.
◦Scale returns to last mode used when turned on.
◦Manual Mode is set as the factory default mode.
◦Refer to the “Mode Seng” secon earlier in
this manual to select the desired mode of use.
❷ The brewing rao will display in the upper right for 3
seconds then go blank.
◦The last rao that was used will be displayed.
◦The rao is set to 1-17 by default.
◦Refer to the “Changing Rao Amount” secon
later in this manual to select the desired rao.
Manual Mode M : (No Automac Funcons)
❶ Place your brewing vessel onto the plaorm.
Weight is shown in the lower weight display.
❷ Press ZERO buon to tare and set display to zero.
◦Brewing vessel weight must be zeroed out
before adding coee grounds.
❸ When the coee bean icon appears, add desired
amount of coee grounds to your brewing vessel.
❹ Press RATIO buon.
◦Scale will calculate the target weight using the
selected rao.
◦Target weight will be displayed in the upper
right of the LCD screen.
❺ When kele icon appears and weight in lower right
of LCD reads, “0.0”:
◦Start the mer by pressing the TIMER buon.
˗ LCD will ash once.
◦Begin adding water to your brewing vessel.
˗ Weight of the water will be displayed in the
lower right as water is added.
TIMER
TIMER
1
9
1810
1911
20
5 7 8
161513 14
12
17
4
6
2
3
1. Silicone Pad
2. Plaorm
3. LCD Readout
4. USB charging
port (on back)
5. Coee Bean Icon
6. Baery life icon
7. MODE indicator
8. Kele Icon
15. Timer
16. Actual Weight
readout
17. Weight Unit
(g or oz)
18. UNIT buon
19. ZERO buon
20. TIMER buon

owner’s manual
Customer Service
(North America):
1-888-538-8683
Local (Wyoming, USA):
307-222-6086
Email:
help@mybrewista.com
ratio : scale
BWRRS1
Scan for Video
9. Rao / Target
Weight readout
10. ON/OFF buon
11. MODE buon
12. RATIO buon
13. “Target” rate bar
segments
14. “Actual” rate bar
segments
Charging the Baery
❶ Open the orange USB port cover at the back of the scale
and insert the small end of the USB cable in this port.
❷ Plug the USB cable into a USB compable outlet to charge
your scale’s baery.
❸ The scale will automacally turn on to verify the charging
connecon.
• Turning o the scale manually will reduce the
charging me.
• Scale is fully charged when the baery icon has
4 bars.
Our scale baery comes with protecon circuit to avoid
over-charging. We strongly recommend unplugging the
scale when it is fully charged.
Please charge the scale as soon as possible when the last
bar in the baery sign disappears, instead of waing ll
scale shuts o due to the power depleon.
READ THIS MANUAL PRIOR TO FIRST
USE AND SAVE FOR FUTURE REFERENCE
1-year Limited Warranty
Rao Scale Components General Maintenance and Care
• Avoid exposure to extreme heat or cold.
◦Always allow your scale to acclimate to normal room
temperature before use.
• Keep your scale in a clean environment.
◦Excessive dust, dirt, vibraon, air currents, as well as
close proximity to other electronic equipment may
have an adverse eect on the accuracy and reliability
of the scale.
• Handle the scale with care.
◦Gently set all items to be weighed on top of the
plaorm and center them.
◦Although this scale is designed to be quite durable,
avoid rough treatment as this may permanently
damage the internal components.
◦Always avoid violent shaking and dropping.
◦This is a precision instrument and should be handled
as such.
Specicaons and Funcons
• Capacity: 2000g
• Accuracy: 0.1g
• Units: grams (g), ounces (oz)
• Key funcons: ON/OFF, MODE, RATIO, UNIT, ZERO, TIMER
• Display: LCD with backlight
• Auto-o
◦Auto-o funcon is set to 180 seconds by default.
◦Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• Operang modes: Automac mode and Manual mode
• Power: (1) Rechargable baery
• Operaon temperature range: 50° to 85° Fahrenheit (10°
to 30° Celsius).
Mode Seng
❶ Turn on the scale by pressing the ON/OFF buon.
❷ Wait unl the LCD displays zero.
❸ Press the MODE buon;
• The display will read “ A ” (automac) or “ M ”
(manual) in the upper le of the LCD readout.
• Press MODE again to toggle between these
two modes.
Notes:
• The scale’s mode cannot be changed when weight is
on the plaorm or during the brewing process.
• The last mode used is retained when the scale is
turned o. Scale returns to the last mode used when
turned back on.
Operaon
Please note:
˗When removing weight from scale, do not apply downward
force or slide items o of the plaorm. Doing so may result
in inaccurate readings. Li items directly o of the plaorm.
˗Heat transfered from the brew vessel to the scale will alter
weight readings slightly. To minimize this, be sure to use the
silicone pad.
Turning Scale On:
❶ Press the ON/OFF buon once to power on the scale.
◦Wait for scale to zero before adding weight to
the plaorm.
◦Scale returns to last mode used when turned on.
◦Manual Mode is set as the factory default mode.
◦Refer to the “Mode Seng” secon earlier in
this manual to select the desired mode of use.
❷ The brewing rao will display in the upper right for 3
seconds then go blank.
◦The last rao that was used will be displayed.
◦The rao is set to 1-17 by default.
◦Refer to the “Changing Rao Amount” secon
later in this manual to select the desired rao.
Manual Mode M : (No Automac Funcons)
❶ Place your brewing vessel onto the plaorm.
Weight is shown in the lower weight display.
❷ Press ZERO buon to tare and set display to zero.
◦Brewing vessel weight must be zeroed out
before adding coee grounds.
❸ When the coee bean icon appears, add desired
amount of coee grounds to your brewing vessel.
❹ Press RATIO buon.
◦Scale will calculate the target weight using the
selected rao.
◦Target weight will be displayed in the upper
right of the LCD screen.
❺ When kele icon appears and weight in lower right
of LCD reads, “0.0”:
◦Start the mer by pressing the TIMER buon.
˗ LCD will ash once.
◦Begin adding water to your brewing vessel.
˗ Weight of the water will be displayed in the
lower right as water is added.
TIMER
TIMER
1
9
1810
1911
20
5 7 8
161513 14
12
17
4
6
2
3
1. Silicone Pad
2. Plaorm
3. LCD Readout
4. USB charging
port (on back)
5. Coee Bean Icon
6. Baery life icon
7. MODE indicator
8. Kele Icon
15. Timer
16. Actual Weight
readout
17. Weight Unit
(g or oz)
18. UNIT buon
19. ZERO buon
20. TIMER buon

owner’s manual
Customer Service
(North America):
1-888-538-8683
Local (Wyoming, USA):
307-222-6086
Email:
help@mybrewista.com
ratio : scale
BWRRS1
Scan for Video
9. Rao / Target
Weight readout
10. ON/OFF buon
11. MODE buon
12. RATIO buon
13. “Target” rate bar
segments
14. “Actual” rate bar
segments
Charging the Baery
❶ Open the orange USB port cover at the back of the scale
and insert the small end of the USB cable in this port.
❷ Plug the USB cable into a USB compable outlet to charge
your scale’s baery.
❸ The scale will automacally turn on to verify the charging
connecon.
• Turning o the scale manually will reduce the
charging me.
• Scale is fully charged when the baery icon has
4 bars.
Our scale baery comes with protecon circuit to avoid
over-charging. We strongly recommend unplugging the
scale when it is fully charged.
Please charge the scale as soon as possible when the last
bar in the baery sign disappears, instead of waing ll
scale shuts o due to the power depleon.
READ THIS MANUAL PRIOR TO FIRST
USE AND SAVE FOR FUTURE REFERENCE
1-year Limited Warranty
Rao Scale Components General Maintenance and Care
• Avoid exposure to extreme heat or cold.
◦Always allow your scale to acclimate to normal room
temperature before use.
• Keep your scale in a clean environment.
◦Excessive dust, dirt, vibraon, air currents, as well as
close proximity to other electronic equipment may
have an adverse eect on the accuracy and reliability
of the scale.
• Handle the scale with care.
◦Gently set all items to be weighed on top of the
plaorm and center them.
◦Although this scale is designed to be quite durable,
avoid rough treatment as this may permanently
damage the internal components.
◦Always avoid violent shaking and dropping.
◦This is a precision instrument and should be handled
as such.
Specicaons and Funcons
• Capacity: 2000g
• Accuracy: 0.1g
• Units: grams (g), ounces (oz)
• Key funcons: ON/OFF, MODE, RATIO, UNIT, ZERO, TIMER
• Display: LCD with backlight
• Auto-o
◦Auto-o funcon is set to 180 seconds by default.
◦Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• Operang modes: Automac mode and Manual mode
• Power: (1) Rechargable baery
• Operaon temperature range: 50° to 85° Fahrenheit (10°
to 30° Celsius).
Mode Seng
❶ Turn on the scale by pressing the ON/OFF buon.
❷ Wait unl the LCD displays zero.
❸ Press the MODE buon;
• The display will read “ A ” (automac) or “ M ”
(manual) in the upper le of the LCD readout.
• Press MODE again to toggle between these
two modes.
Notes:
• The scale’s mode cannot be changed when weight is
on the plaorm or during the brewing process.
• The last mode used is retained when the scale is
turned o. Scale returns to the last mode used when
turned back on.
Operaon
Please note:
˗When removing weight from scale, do not apply downward
force or slide items o of the plaorm. Doing so may result
in inaccurate readings. Li items directly o of the plaorm.
˗Heat transfered from the brew vessel to the scale will alter
weight readings slightly. To minimize this, be sure to use the
silicone pad.
Turning Scale On:
❶ Press the ON/OFF buon once to power on the scale.
◦Wait for scale to zero before adding weight to
the plaorm.
◦Scale returns to last mode used when turned on.
◦Manual Mode is set as the factory default mode.
◦Refer to the “Mode Seng” secon earlier in
this manual to select the desired mode of use.
❷ The brewing rao will display in the upper right for 3
seconds then go blank.
◦The last rao that was used will be displayed.
◦The rao is set to 1-17 by default.
◦Refer to the “Changing Rao Amount” secon
later in this manual to select the desired rao.
Manual Mode M : (No Automac Funcons)
❶ Place your brewing vessel onto the plaorm.
Weight is shown in the lower weight display.
❷ Press ZERO buon to tare and set display to zero.
◦Brewing vessel weight must be zeroed out
before adding coee grounds.
❸ When the coee bean icon appears, add desired
amount of coee grounds to your brewing vessel.
❹ Press RATIO buon.
◦Scale will calculate the target weight using the
selected rao.
◦Target weight will be displayed in the upper
right of the LCD screen.
❺ When kele icon appears and weight in lower right
of LCD reads, “0.0”:
◦Start the mer by pressing the TIMER buon.
˗ LCD will ash once.
◦Begin adding water to your brewing vessel.
˗ Weight of the water will be displayed in the
lower right as water is added.
TIMER
TIMER
1
9
1810
1911
20
5 7 8
161513 14
12
17
4
6
2
3
1. Silicone Pad
2. Plaorm
3. LCD Readout
4. USB charging
port (on back)
5. Coee Bean Icon
6. Baery life icon
7. MODE indicator
8. Kele Icon
15. Timer
16. Actual Weight
readout
17. Weight Unit
(g or oz)
18. UNIT buon
19. ZERO buon
20. TIMER buon

owner’s manual
Customer Service
(North America):
1-888-538-8683
Local (Wyoming, USA):
307-222-6086
Email:
help@mybrewista.com
ratio : scale
BWRRS1
Scan for Video
9. Rao / Target
Weight readout
10. ON/OFF buon
11. MODE buon
12. RATIO buon
13. “Target” rate bar
segments
14. “Actual” rate bar
segments
Charging the Baery
❶ Open the orange USB port cover at the back of the scale
and insert the small end of the USB cable in this port.
❷ Plug the USB cable into a USB compable outlet to charge
your scale’s baery.
❸ The scale will automacally turn on to verify the charging
connecon.
• Turning o the scale manually will reduce the
charging me.
• Scale is fully charged when the baery icon has
4 bars.
Our scale baery comes with protecon circuit to avoid
over-charging. We strongly recommend unplugging the
scale when it is fully charged.
Please charge the scale as soon as possible when the last
bar in the baery sign disappears, instead of waing ll
scale shuts o due to the power depleon.
READ THIS MANUAL PRIOR TO FIRST
USE AND SAVE FOR FUTURE REFERENCE
1-year Limited Warranty
Rao Scale Components General Maintenance and Care
• Avoid exposure to extreme heat or cold.
◦Always allow your scale to acclimate to normal room
temperature before use.
• Keep your scale in a clean environment.
◦Excessive dust, dirt, vibraon, air currents, as well as
close proximity to other electronic equipment may
have an adverse eect on the accuracy and reliability
of the scale.
• Handle the scale with care.
◦Gently set all items to be weighed on top of the
plaorm and center them.
◦Although this scale is designed to be quite durable,
avoid rough treatment as this may permanently
damage the internal components.
◦Always avoid violent shaking and dropping.
◦This is a precision instrument and should be handled
as such.
Specicaons and Funcons
• Capacity: 2000g
• Accuracy: 0.1g
• Units: grams (g), ounces (oz)
• Key funcons: ON/OFF, MODE, RATIO, UNIT, ZERO, TIMER
• Display: LCD with backlight
• Auto-o
◦Auto-o funcon is set to 180 seconds by default.
◦Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• Operang modes: Automac mode and Manual mode
• Power: (1) Rechargable baery
• Operaon temperature range: 50° to 85° Fahrenheit (10°
to 30° Celsius).
Mode Seng
❶ Turn on the scale by pressing the ON/OFF buon.
❷ Wait unl the LCD displays zero.
❸ Press the MODE buon;
• The display will read “ A ” (automac) or “ M ”
(manual) in the upper le of the LCD readout.
• Press MODE again to toggle between these
two modes.
Notes:
• The scale’s mode cannot be changed when weight is
on the plaorm or during the brewing process.
• The last mode used is retained when the scale is
turned o. Scale returns to the last mode used when
turned back on.
Operaon
Please note:
˗When removing weight from scale, do not apply downward
force or slide items o of the plaorm. Doing so may result
in inaccurate readings. Li items directly o of the plaorm.
˗Heat transfered from the brew vessel to the scale will alter
weight readings slightly. To minimize this, be sure to use the
silicone pad.
Turning Scale On:
❶ Press the ON/OFF buon once to power on the scale.
◦Wait for scale to zero before adding weight to
the plaorm.
◦Scale returns to last mode used when turned on.
◦Manual Mode is set as the factory default mode.
◦Refer to the “Mode Seng” secon earlier in
this manual to select the desired mode of use.
❷ The brewing rao will display in the upper right for 3
seconds then go blank.
◦The last rao that was used will be displayed.
◦The rao is set to 1-17 by default.
◦Refer to the “Changing Rao Amount” secon
later in this manual to select the desired rao.
Manual Mode M : (No Automac Funcons)
❶ Place your brewing vessel onto the plaorm.
Weight is shown in the lower weight display.
❷ Press ZERO buon to tare and set display to zero.
◦Brewing vessel weight must be zeroed out
before adding coee grounds.
❸ When the coee bean icon appears, add desired
amount of coee grounds to your brewing vessel.
❹ Press RATIO buon.
◦Scale will calculate the target weight using the
selected rao.
◦Target weight will be displayed in the upper
right of the LCD screen.
❺ When kele icon appears and weight in lower right
of LCD reads, “0.0”:
◦Start the mer by pressing the TIMER buon.
˗ LCD will ash once.
◦Begin adding water to your brewing vessel.
˗ Weight of the water will be displayed in the
lower right as water is added.
TIMER
TIMER
1
9
1810
1911
20
5 7 8
161513 14
12
17
4
6
2
3
1. Silicone Pad
2. Plaorm
3. LCD Readout
4. USB charging
port (on back)
5. Coee Bean Icon
6. Baery life icon
7. MODE indicator
8. Kele Icon
15. Timer
16. Actual Weight
readout
17. Weight Unit
(g or oz)
18. UNIT buon
19. ZERO buon
20. TIMER buon

owner’s manual
Customer Service
(North America):
1-888-538-8683
Local (Wyoming, USA):
307-222-6086
Email:
help@mybrewista.com
ratio : scale
BWRRS1
Scan for Video
9. Rao / Target
Weight readout
10. ON/OFF buon
11. MODE buon
12. RATIO buon
13. “Target” rate bar
segments
14. “Actual” rate bar
segments
Charging the Baery
❶ Open the orange USB port cover at the back of the scale
and insert the small end of the USB cable in this port.
❷ Plug the USB cable into a USB compable outlet to charge
your scale’s baery.
❸ The scale will automacally turn on to verify the charging
connecon.
• Turning o the scale manually will reduce the
charging me.
• Scale is fully charged when the baery icon has
4 bars.
Our scale baery comes with protecon circuit to avoid
over-charging. We strongly recommend unplugging the
scale when it is fully charged.
Please charge the scale as soon as possible when the last
bar in the baery sign disappears, instead of waing ll
scale shuts o due to the power depleon.
READ THIS MANUAL PRIOR TO FIRST
USE AND SAVE FOR FUTURE REFERENCE
1-year Limited Warranty
Rao Scale Components General Maintenance and Care
• Avoid exposure to extreme heat or cold.
◦Always allow your scale to acclimate to normal room
temperature before use.
• Keep your scale in a clean environment.
◦Excessive dust, dirt, vibraon, air currents, as well as
close proximity to other electronic equipment may
have an adverse eect on the accuracy and reliability
of the scale.
• Handle the scale with care.
◦Gently set all items to be weighed on top of the
plaorm and center them.
◦Although this scale is designed to be quite durable,
avoid rough treatment as this may permanently
damage the internal components.
◦Always avoid violent shaking and dropping.
◦This is a precision instrument and should be handled
as such.
Specicaons and Funcons
• Capacity: 2000g
• Accuracy: 0.1g
• Units: grams (g), ounces (oz)
• Key funcons: ON/OFF, MODE, RATIO, UNIT, ZERO, TIMER
• Display: LCD with backlight
• Auto-o
◦Auto-o funcon is set to 180 seconds by default.
◦Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• Operang modes: Automac mode and Manual mode
• Power: (1) Rechargable baery
• Operaon temperature range: 50° to 85° Fahrenheit (10°
to 30° Celsius).
Mode Seng
❶ Turn on the scale by pressing the ON/OFF buon.
❷ Wait unl the LCD displays zero.
❸ Press the MODE buon;
• The display will read “ A ” (automac) or “ M ”
(manual) in the upper le of the LCD readout.
• Press MODE again to toggle between these
two modes.
Notes:
• The scale’s mode cannot be changed when weight is
on the plaorm or during the brewing process.
• The last mode used is retained when the scale is
turned o. Scale returns to the last mode used when
turned back on.
Operaon
Please note:
˗When removing weight from scale, do not apply downward
force or slide items o of the plaorm. Doing so may result
in inaccurate readings. Li items directly o of the plaorm.
˗Heat transfered from the brew vessel to the scale will alter
weight readings slightly. To minimize this, be sure to use the
silicone pad.
Turning Scale On:
❶ Press the ON/OFF buon once to power on the scale.
◦Wait for scale to zero before adding weight to
the plaorm.
◦Scale returns to last mode used when turned on.
◦Manual Mode is set as the factory default mode.
◦Refer to the “Mode Seng” secon earlier in
this manual to select the desired mode of use.
❷ The brewing rao will display in the upper right for 3
seconds then go blank.
◦The last rao that was used will be displayed.
◦The rao is set to 1-17 by default.
◦Refer to the “Changing Rao Amount” secon
later in this manual to select the desired rao.
Manual Mode M : (No Automac Funcons)
❶ Place your brewing vessel onto the plaorm.
Weight is shown in the lower weight display.
❷ Press ZERO buon to tare and set display to zero.
◦Brewing vessel weight must be zeroed out
before adding coee grounds.
❸ When the coee bean icon appears, add desired
amount of coee grounds to your brewing vessel.
❹ Press RATIO buon.
◦Scale will calculate the target weight using the
selected rao.
◦Target weight will be displayed in the upper
right of the LCD screen.
❺ When kele icon appears and weight in lower right
of LCD reads, “0.0”:
◦Start the mer by pressing the TIMER buon.
˗ LCD will ash once.
◦Begin adding water to your brewing vessel.
˗ Weight of the water will be displayed in the
lower right as water is added.
TIMER
TIMER
1
9
1810
1911
20
5 7 8
161513 14
12
17
4
6
2
3
1. Silicone Pad
2. Plaorm
3. LCD Readout
4. USB charging
port (on back)
5. Coee Bean Icon
6. Baery life icon
7. MODE indicator
8. Kele Icon
15. Timer
16. Actual Weight
readout
17. Weight Unit
(g or oz)
18. UNIT buon
19. ZERO buon
20. TIMER buon

owner’s manual
Customer Service
(North America):
1-888-538-8683
Local (Wyoming, USA):
307-222-6086
Email:
help@mybrewista.com
ratio : scale
BWRRS1
Scan for Video
9. Rao / Target
Weight readout
10. ON/OFF buon
11. MODE buon
12. RATIO buon
13. “Target” rate bar
segments
14. “Actual” rate bar
segments
Charging the Baery
❶ Open the orange USB port cover at the back of the scale
and insert the small end of the USB cable in this port.
❷ Plug the USB cable into a USB compable outlet to charge
your scale’s baery.
❸ The scale will automacally turn on to verify the charging
connecon.
• Turning o the scale manually will reduce the
charging me.
• Scale is fully charged when the baery icon has
4 bars.
Our scale baery comes with protecon circuit to avoid
over-charging. We strongly recommend unplugging the
scale when it is fully charged.
Please charge the scale as soon as possible when the last
bar in the baery sign disappears, instead of waing ll
scale shuts o due to the power depleon.
READ THIS MANUAL PRIOR TO FIRST
USE AND SAVE FOR FUTURE REFERENCE
1-year Limited Warranty
Rao Scale Components General Maintenance and Care
• Avoid exposure to extreme heat or cold.
◦Always allow your scale to acclimate to normal room
temperature before use.
• Keep your scale in a clean environment.
◦Excessive dust, dirt, vibraon, air currents, as well as
close proximity to other electronic equipment may
have an adverse eect on the accuracy and reliability
of the scale.
• Handle the scale with care.
◦Gently set all items to be weighed on top of the
plaorm and center them.
◦Although this scale is designed to be quite durable,
avoid rough treatment as this may permanently
damage the internal components.
◦Always avoid violent shaking and dropping.
◦This is a precision instrument and should be handled
as such.
Specicaons and Funcons
• Capacity: 2000g
• Accuracy: 0.1g
• Units: grams (g), ounces (oz)
• Key funcons: ON/OFF, MODE, RATIO, UNIT, ZERO, TIMER
• Display: LCD with backlight
• Auto-o
◦Auto-o funcon is set to 180 seconds by default.
◦Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• Operang modes: Automac mode and Manual mode
• Power: (1) Rechargable baery
• Operaon temperature range: 50° to 85° Fahrenheit (10°
to 30° Celsius).
Mode Seng
❶ Turn on the scale by pressing the ON/OFF buon.
❷ Wait unl the LCD displays zero.
❸ Press the MODE buon;
• The display will read “ A ” (automac) or “ M ”
(manual) in the upper le of the LCD readout.
• Press MODE again to toggle between these
two modes.
Notes:
• The scale’s mode cannot be changed when weight is
on the plaorm or during the brewing process.
• The last mode used is retained when the scale is
turned o. Scale returns to the last mode used when
turned back on.
Operaon
Please note:
˗When removing weight from scale, do not apply downward
force or slide items o of the plaorm. Doing so may result
in inaccurate readings. Li items directly o of the plaorm.
˗Heat transfered from the brew vessel to the scale will alter
weight readings slightly. To minimize this, be sure to use the
silicone pad.
Turning Scale On:
❶ Press the ON/OFF buon once to power on the scale.
◦Wait for scale to zero before adding weight to
the plaorm.
◦Scale returns to last mode used when turned on.
◦Manual Mode is set as the factory default mode.
◦Refer to the “Mode Seng” secon earlier in
this manual to select the desired mode of use.
❷ The brewing rao will display in the upper right for 3
seconds then go blank.
◦The last rao that was used will be displayed.
◦The rao is set to 1-17 by default.
◦Refer to the “Changing Rao Amount” secon
later in this manual to select the desired rao.
Manual Mode M : (No Automac Funcons)
❶ Place your brewing vessel onto the plaorm.
Weight is shown in the lower weight display.
❷ Press ZERO buon to tare and set display to zero.
◦Brewing vessel weight must be zeroed out
before adding coee grounds.
❸ When the coee bean icon appears, add desired
amount of coee grounds to your brewing vessel.
❹ Press RATIO buon.
◦Scale will calculate the target weight using the
selected rao.
◦Target weight will be displayed in the upper
right of the LCD screen.
❺ When kele icon appears and weight in lower right
of LCD reads, “0.0”:
◦Start the mer by pressing the TIMER buon.
˗ LCD will ash once.
◦Begin adding water to your brewing vessel.
˗ Weight of the water will be displayed in the
lower right as water is added.
TIMER
TIMER
1
9
1810
1911
20
5 7 8
161513 14
12
17
4
6
2
3
1. Silicone Pad
2. Plaorm
3. LCD Readout
4. USB charging
port (on back)
5. Coee Bean Icon
6. Baery life icon
7. MODE indicator
8. Kele Icon
15. Timer
16. Actual Weight
readout
17. Weight Unit
(g or oz)
18. UNIT buon
19. ZERO buon
20. TIMER buon

owner’s manual
Customer Service
(North America):
1-888-538-8683
Local (Wyoming, USA):
307-222-6086
Email:
help@mybrewista.com
ratio : scale
BWRRS1
Scan for Video
9. Rao / Target
Weight readout
10. ON/OFF buon
11. MODE buon
12. RATIO buon
13. “Target” rate bar
segments
14. “Actual” rate bar
segments
Charging the Baery
❶ Open the orange USB port cover at the back of the scale
and insert the small end of the USB cable in this port.
❷ Plug the USB cable into a USB compable outlet to charge
your scale’s baery.
❸ The scale will automacally turn on to verify the charging
connecon.
• Turning o the scale manually will reduce the
charging me.
• Scale is fully charged when the baery icon has
4 bars.
Our scale baery comes with protecon circuit to avoid
over-charging. We strongly recommend unplugging the
scale when it is fully charged.
Please charge the scale as soon as possible when the last
bar in the baery sign disappears, instead of waing ll
scale shuts o due to the power depleon.
READ THIS MANUAL PRIOR TO FIRST
USE AND SAVE FOR FUTURE REFERENCE
1-year Limited Warranty
Rao Scale Components General Maintenance and Care
• Avoid exposure to extreme heat or cold.
◦Always allow your scale to acclimate to normal room
temperature before use.
• Keep your scale in a clean environment.
◦Excessive dust, dirt, vibraon, air currents, as well as
close proximity to other electronic equipment may
have an adverse eect on the accuracy and reliability
of the scale.
• Handle the scale with care.
◦Gently set all items to be weighed on top of the
plaorm and center them.
◦Although this scale is designed to be quite durable,
avoid rough treatment as this may permanently
damage the internal components.
◦Always avoid violent shaking and dropping.
◦This is a precision instrument and should be handled
as such.
Specicaons and Funcons
• Capacity: 2000g
• Accuracy: 0.1g
• Units: grams (g), ounces (oz)
• Key funcons: ON/OFF, MODE, RATIO, UNIT, ZERO, TIMER
• Display: LCD with backlight
• Auto-o
◦Auto-o funcon is set to 180 seconds by default.
◦Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• Operang modes: Automac mode and Manual mode
• Power: (1) Rechargable baery
• Operaon temperature range: 50° to 85° Fahrenheit (10°
to 30° Celsius).
Mode Seng
❶ Turn on the scale by pressing the ON/OFF buon.
❷ Wait unl the LCD displays zero.
❸ Press the MODE buon;
• The display will read “ A ” (automac) or “ M ”
(manual) in the upper le of the LCD readout.
• Press MODE again to toggle between these
two modes.
Notes:
• The scale’s mode cannot be changed when weight is
on the plaorm or during the brewing process.
• The last mode used is retained when the scale is
turned o. Scale returns to the last mode used when
turned back on.
Operaon
Please note:
˗When removing weight from scale, do not apply downward
force or slide items o of the plaorm. Doing so may result
in inaccurate readings. Li items directly o of the plaorm.
˗Heat transfered from the brew vessel to the scale will alter
weight readings slightly. To minimize this, be sure to use the
silicone pad.
Turning Scale On:
❶ Press the ON/OFF buon once to power on the scale.
◦Wait for scale to zero before adding weight to
the plaorm.
◦Scale returns to last mode used when turned on.
◦Manual Mode is set as the factory default mode.
◦Refer to the “Mode Seng” secon earlier in
this manual to select the desired mode of use.
❷ The brewing rao will display in the upper right for 3
seconds then go blank.
◦The last rao that was used will be displayed.
◦The rao is set to 1-17 by default.
◦Refer to the “Changing Rao Amount” secon
later in this manual to select the desired rao.
Manual Mode M : (No Automac Funcons)
❶ Place your brewing vessel onto the plaorm.
Weight is shown in the lower weight display.
❷ Press ZERO buon to tare and set display to zero.
◦Brewing vessel weight must be zeroed out
before adding coee grounds.
❸ When the coee bean icon appears, add desired
amount of coee grounds to your brewing vessel.
❹ Press RATIO buon.
◦Scale will calculate the target weight using the
selected rao.
◦Target weight will be displayed in the upper
right of the LCD screen.
❺ When kele icon appears and weight in lower right
of LCD reads, “0.0”:
◦Start the mer by pressing the TIMER buon.
˗ LCD will ash once.
◦Begin adding water to your brewing vessel.
˗ Weight of the water will be displayed in the
lower right as water is added.
TIMER
TIMER
1
9
1810
1911
20
5 7 8
161513 14
12
17
4
6
2
3
1. Silicone Pad
2. Plaorm
3. LCD Readout
4. USB charging
port (on back)
5. Coee Bean Icon
6. Baery life icon
7. MODE indicator
8. Kele Icon
15. Timer
16. Actual Weight
readout
17. Weight Unit
(g or oz)
18. UNIT buon
19. ZERO buon
20. TIMER buon

owner’s manual
Customer Service
(North America):
1-888-538-8683
Local (Wyoming, USA):
307-222-6086
Email:
help@mybrewista.com
ratio : scale
BWRRS1
Scan for Video
9. Rao / Target
Weight readout
10. ON/OFF buon
11. MODE buon
12. RATIO buon
13. “Target” rate bar
segments
14. “Actual” rate bar
segments
Charging the Baery
❶ Open the orange USB port cover at the back of the scale
and insert the small end of the USB cable in this port.
❷ Plug the USB cable into a USB compable outlet to charge
your scale’s baery.
❸ The scale will automacally turn on to verify the charging
connecon.
• Turning o the scale manually will reduce the
charging me.
• Scale is fully charged when the baery icon has
4 bars.
Our scale baery comes with protecon circuit to avoid
over-charging. We strongly recommend unplugging the
scale when it is fully charged.
Please charge the scale as soon as possible when the last
bar in the baery sign disappears, instead of waing ll
scale shuts o due to the power depleon.
READ THIS MANUAL PRIOR TO FIRST
USE AND SAVE FOR FUTURE REFERENCE
1-year Limited Warranty
Rao Scale Components General Maintenance and Care
• Avoid exposure to extreme heat or cold.
◦Always allow your scale to acclimate to normal room
temperature before use.
• Keep your scale in a clean environment.
◦Excessive dust, dirt, vibraon, air currents, as well as
close proximity to other electronic equipment may
have an adverse eect on the accuracy and reliability
of the scale.
• Handle the scale with care.
◦Gently set all items to be weighed on top of the
plaorm and center them.
◦Although this scale is designed to be quite durable,
avoid rough treatment as this may permanently
damage the internal components.
◦Always avoid violent shaking and dropping.
◦This is a precision instrument and should be handled
as such.
Specicaons and Funcons
• Capacity: 2000g
• Accuracy: 0.1g
• Units: grams (g), ounces (oz)
• Key funcons: ON/OFF, MODE, RATIO, UNIT, ZERO, TIMER
• Display: LCD with backlight
• Auto-o
◦Auto-o funcon is set to 180 seconds by default.
◦Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• Operang modes: Automac mode and Manual mode
• Power: (1) Rechargable baery
• Operaon temperature range: 50° to 85° Fahrenheit (10°
to 30° Celsius).
Mode Seng
❶ Turn on the scale by pressing the ON/OFF buon.
❷ Wait unl the LCD displays zero.
❸ Press the MODE buon;
• The display will read “ A ” (automac) or “ M ”
(manual) in the upper le of the LCD readout.
• Press MODE again to toggle between these
two modes.
Notes:
• The scale’s mode cannot be changed when weight is
on the plaorm or during the brewing process.
• The last mode used is retained when the scale is
turned o. Scale returns to the last mode used when
turned back on.
Operaon
Please note:
˗When removing weight from scale, do not apply downward
force or slide items o of the plaorm. Doing so may result
in inaccurate readings. Li items directly o of the plaorm.
˗Heat transfered from the brew vessel to the scale will alter
weight readings slightly. To minimize this, be sure to use the
silicone pad.
Turning Scale On:
❶ Press the ON/OFF buon once to power on the scale.
◦Wait for scale to zero before adding weight to
the plaorm.
◦Scale returns to last mode used when turned on.
◦Manual Mode is set as the factory default mode.
◦Refer to the “Mode Seng” secon earlier in
this manual to select the desired mode of use.
❷ The brewing rao will display in the upper right for 3
seconds then go blank.
◦The last rao that was used will be displayed.
◦The rao is set to 1-17 by default.
◦Refer to the “Changing Rao Amount” secon
later in this manual to select the desired rao.
Manual Mode M : (No Automac Funcons)
❶ Place your brewing vessel onto the plaorm.
Weight is shown in the lower weight display.
❷ Press ZERO buon to tare and set display to zero.
◦Brewing vessel weight must be zeroed out
before adding coee grounds.
❸ When the coee bean icon appears, add desired
amount of coee grounds to your brewing vessel.
❹ Press RATIO buon.
◦Scale will calculate the target weight using the
selected rao.
◦Target weight will be displayed in the upper
right of the LCD screen.
❺ When kele icon appears and weight in lower right
of LCD reads, “0.0”:
◦Start the mer by pressing the TIMER buon.
˗ LCD will ash once.
◦Begin adding water to your brewing vessel.
˗ Weight of the water will be displayed in the
lower right as water is added.
TIMER
TIMER
1
9
1810
1911
20
5 7 8
161513 14
12
17
4
6
2
3
1. Silicone Pad
2. Plaorm
3. LCD Readout
4. USB charging
port (on back)
5. Coee Bean Icon
6. Baery life icon
7. MODE indicator
8. Kele Icon
15. Timer
16. Actual Weight
readout
17. Weight Unit
(g or oz)
18. UNIT buon
19. ZERO buon
20. TIMER buon

DO NOT use liquid bleach or other harsh chemicals.
DO NOT use steel wool or abrasive sponges as this can
scratch the surface.
DO NOT submerge the scale.
Avoid pouring water directly into your scale, as water
may become trapped. If this occurs drying me may
exceed 4 hours.
Water drops on the LCD display will not interfere with
your weighing. These drops will dry and disappear.
If the scale displays “ ” or the readings jump aer
washing, then water is sll inside the scale. Simply shake
out the excess water and let your scale dry longer.
By following these washing instrucons, you will experience
shorter drying mes and your scale will provide you with years
of reliable service.
the top right of the LCD, the screen begins to
ash. This means that you are close to the nal
amount of water needed.
❺ Once the Target Weight is reached, the display color
will change from orange to white.
◦Timer connues to count up.
◦Weight reading will show actual weight even if
it is greater than the target weight.
❻ Remove brewing vessel aer brewing is complete.
◦Weight and nal Time reading remains on the
display for ve seconds then return to zero.
◦Scale is now ready for another brew.
Zero (Tare) Funcon
• Zero funcon is disabled under “AUTO” mode.
• Under Manual mode: press the ZERO buon as needed.
Auto-o Seng
• Auto-o funcon is set to 180 seconds by default.
• Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• To change the Auto-o me seng or disable this funcon:
❶Turn o the scale.
❷ Press and hold the ON/OFF buon.
❸ While holding the ON/OFF buon, press the ZERO
buon 4-5 mes quickly unl “180” is shown on the
LCD display.
❹ Release both buons.
❺ Press the ZERO buon to switch between
“0/60/120/180”.
◦If “0” is selected, the Auto-o funcon will be
disabled.
❻ Aer choosing the desired me, press the ON/OFF
buon again.
❼ The display will show “PASS” to conrm this seng.
❽ The scale will turn o automacally.
Note:
◦If “60”, “120”, or “180” is chosen, the scale will
turn o aer the designated number of seconds of
inacvity.
◦If the Auto-o funcon is disabled, the scale will not
shut o on its own.
Please note: To maintain a longer baery life, turn o the scale
by pressing the ON/OFF buon aer each use.
Auto Mode A : (Automac Zero and Timer)
❶ Place brewing vessel on the scale plaorm.
◦Aer 3 seconds, weight reading goes to “0.0”
(Auto-tares).
❷ When the coee bean icon appears in the upper
le of the LCD screen, add coee grounds to the
brewing vessel.
◦Adjust the amount of coee grounds as needed.
❸ Press the RATIO buon.
◦The upper right of the LCD shows the calculated
target weight and the lower display shows zero.
❹ When the kele icon appears, begin adding water to
your brewing vessel.
◦The count-up mer begins automacally.
◦The Upper “Target” rate bar segments appear
at 10 second intervals.
◦The Lower “Actual” rate bar segments appear
as water is added.
◦Pour brewing water at a rate that keeps the
lower and upper bars even.
◦When the weight of the added water reaches
60g less than the calculated amount shown at
◦As the mer counts up, the Upper “Target” rate
bar segments appear at 10 second intervals.
◦As water is added, the Lower “Actual” rate bar
segments appear.
◦Numeric me is displayed in the lower le LCD.
❻ When the weight of the water added reaches 60g
less than the calculated amount shown at the top
right, the screen begins to ash. This means that you
are close to the nal amount of water needed.
❼ Once the lower display reading reaches the upper
display volume the enre display screen will change
color from orange to white.
❽ Stop adding water to the brewing vessel.
◦If the vessel is removed from the scale weight
in lower right will show a negave reading.
◦Timer will connue. Press the TIMER buon to
stop the mer.
◦Press the TIMER buon again to reset the mer
to zero.
◦Press the ZERO buon to clear the weight
reading and the rao.
Warning Messages
• “ ”: Overload
◦Quickly remove weight from plaorm to protect the
scale.
• “ ”: Unstable
◦Scale is not steady during start up. Please turn o
scale, set on a stable surface and restart scale.
◦Water is inside the scale. Shake out excess water
and let dry.
Washing Instrucons
This scale has been treated with a water-resistant nano-
coang. However, washing the scale under running water is
not recommended. Please follow these instrucons when
washing:
❶ Wash the exterior of the scale with a so, damp cloth
❷ Do not wash scale under running water.
❸ Leave scale to dry on a dish rack with LCD and buons
poinng upward.
Changing Units of Measurement
• Press the UNIT buon to switch between grams (g) and
ounces (oz).
◦Grams (g) is the default unit of measurement.
◦Units cannot be changed during the brewing process.
Changing The Set Rao
❶ Press and hold the RATIO buon for 3 seconds.
◦The rao will display blinking in the upper right of
the LCD.
❷ Press the RATIO buon unl the desired rao is displayed.
◦The default rao is 1:17 (add 1 part coee to 17 parts
water).
◦Scale has 7 pre-set raos: 1:14, 1:15, 1:16, 1:17,
1:18, 1:19, and 1:20
❸ Wait three seconds and the scale will automacally store
the new rao and return to the mode you were in last.
◦Rao cannot be changed once the brewing process
has begun.
Calibraon
❶ While the scale is o, press and hold the ON/OFF buon
and ZERO buon at the same me.
◦The LCD will read “CAL” in the upper right.
❷ Press the ZERO buon again and the LCD will ash
“500.0g”.
❸ Place a 500g calibraon weight onto the center of the
plaorm.
❹ The LCD will read “PASS” then return to the normal
weighing mode.
❻ Calibraon is complete.
Correct Disposal of this Product
This symbol indicates that this product should not be disposed of
with other household wastes throughout the European Union. To
prevent possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return your used device,
please use the return and collecon systems or contact the retailer
where the product was purchased. They can collect this product for
environmentally safe recycling.

DO NOT use liquid bleach or other harsh chemicals.
DO NOT use steel wool or abrasive sponges as this can
scratch the surface.
DO NOT submerge the scale.
Avoid pouring water directly into your scale, as water
may become trapped. If this occurs drying me may
exceed 4 hours.
Water drops on the LCD display will not interfere with
your weighing. These drops will dry and disappear.
If the scale displays “ ” or the readings jump aer
washing, then water is sll inside the scale. Simply shake
out the excess water and let your scale dry longer.
By following these washing instrucons, you will experience
shorter drying mes and your scale will provide you with years
of reliable service.
the top right of the LCD, the screen begins to
ash. This means that you are close to the nal
amount of water needed.
❺ Once the Target Weight is reached, the display color
will change from orange to white.
◦Timer connues to count up.
◦Weight reading will show actual weight even if
it is greater than the target weight.
❻ Remove brewing vessel aer brewing is complete.
◦Weight and nal Time reading remains on the
display for ve seconds then return to zero.
◦Scale is now ready for another brew.
Zero (Tare) Funcon
• Zero funcon is disabled under “AUTO” mode.
• Under Manual mode: press the ZERO buon as needed.
Auto-o Seng
• Auto-o funcon is set to 180 seconds by default.
• Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• To change the Auto-o me seng or disable this funcon:
❶Turn o the scale.
❷ Press and hold the ON/OFF buon.
❸ While holding the ON/OFF buon, press the ZERO
buon 4-5 mes quickly unl “180” is shown on the
LCD display.
❹ Release both buons.
❺ Press the ZERO buon to switch between
“0/60/120/180”.
◦If “0” is selected, the Auto-o funcon will be
disabled.
❻ Aer choosing the desired me, press the ON/OFF
buon again.
❼ The display will show “PASS” to conrm this seng.
❽ The scale will turn o automacally.
Note:
◦If “60”, “120”, or “180” is chosen, the scale will
turn o aer the designated number of seconds of
inacvity.
◦If the Auto-o funcon is disabled, the scale will not
shut o on its own.
Please note: To maintain a longer baery life, turn o the scale
by pressing the ON/OFF buon aer each use.
Auto Mode A : (Automac Zero and Timer)
❶ Place brewing vessel on the scale plaorm.
◦Aer 3 seconds, weight reading goes to “0.0”
(Auto-tares).
❷ When the coee bean icon appears in the upper
le of the LCD screen, add coee grounds to the
brewing vessel.
◦Adjust the amount of coee grounds as needed.
❸ Press the RATIO buon.
◦The upper right of the LCD shows the calculated
target weight and the lower display shows zero.
❹ When the kele icon appears, begin adding water to
your brewing vessel.
◦The count-up mer begins automacally.
◦The Upper “Target” rate bar segments appear
at 10 second intervals.
◦The Lower “Actual” rate bar segments appear
as water is added.
◦Pour brewing water at a rate that keeps the
lower and upper bars even.
◦When the weight of the added water reaches
60g less than the calculated amount shown at
◦As the mer counts up, the Upper “Target” rate
bar segments appear at 10 second intervals.
◦As water is added, the Lower “Actual” rate bar
segments appear.
◦Numeric me is displayed in the lower le LCD.
❻ When the weight of the water added reaches 60g
less than the calculated amount shown at the top
right, the screen begins to ash. This means that you
are close to the nal amount of water needed.
❼ Once the lower display reading reaches the upper
display volume the enre display screen will change
color from orange to white.
❽ Stop adding water to the brewing vessel.
◦If the vessel is removed from the scale weight
in lower right will show a negave reading.
◦Timer will connue. Press the TIMER buon to
stop the mer.
◦Press the TIMER buon again to reset the mer
to zero.
◦Press the ZERO buon to clear the weight
reading and the rao.
Warning Messages
• “ ”: Overload
◦Quickly remove weight from plaorm to protect the
scale.
• “ ”: Unstable
◦Scale is not steady during start up. Please turn o
scale, set on a stable surface and restart scale.
◦Water is inside the scale. Shake out excess water
and let dry.
Washing Instrucons
This scale has been treated with a water-resistant nano-
coang. However, washing the scale under running water is
not recommended. Please follow these instrucons when
washing:
❶ Wash the exterior of the scale with a so, damp cloth
❷ Do not wash scale under running water.
❸ Leave scale to dry on a dish rack with LCD and buons
poinng upward.
Changing Units of Measurement
• Press the UNIT buon to switch between grams (g) and
ounces (oz).
◦Grams (g) is the default unit of measurement.
◦Units cannot be changed during the brewing process.
Changing The Set Rao
❶ Press and hold the RATIO buon for 3 seconds.
◦The rao will display blinking in the upper right of
the LCD.
❷ Press the RATIO buon unl the desired rao is displayed.
◦The default rao is 1:17 (add 1 part coee to 17 parts
water).
◦Scale has 7 pre-set raos: 1:14, 1:15, 1:16, 1:17,
1:18, 1:19, and 1:20
❸ Wait three seconds and the scale will automacally store
the new rao and return to the mode you were in last.
◦Rao cannot be changed once the brewing process
has begun.
Calibraon
❶ While the scale is o, press and hold the ON/OFF buon
and ZERO buon at the same me.
◦The LCD will read “CAL” in the upper right.
❷ Press the ZERO buon again and the LCD will ash
“500.0g”.
❸ Place a 500g calibraon weight onto the center of the
plaorm.
❹ The LCD will read “PASS” then return to the normal
weighing mode.
❻ Calibraon is complete.
Correct Disposal of this Product
This symbol indicates that this product should not be disposed of
with other household wastes throughout the European Union. To
prevent possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return your used device,
please use the return and collecon systems or contact the retailer
where the product was purchased. They can collect this product for
environmentally safe recycling.

DO NOT use liquid bleach or other harsh chemicals.
DO NOT use steel wool or abrasive sponges as this can
scratch the surface.
DO NOT submerge the scale.
Avoid pouring water directly into your scale, as water
may become trapped. If this occurs drying me may
exceed 4 hours.
Water drops on the LCD display will not interfere with
your weighing. These drops will dry and disappear.
If the scale displays “ ” or the readings jump aer
washing, then water is sll inside the scale. Simply shake
out the excess water and let your scale dry longer.
By following these washing instrucons, you will experience
shorter drying mes and your scale will provide you with years
of reliable service.
the top right of the LCD, the screen begins to
ash. This means that you are close to the nal
amount of water needed.
❺ Once the Target Weight is reached, the display color
will change from orange to white.
◦Timer connues to count up.
◦Weight reading will show actual weight even if
it is greater than the target weight.
❻ Remove brewing vessel aer brewing is complete.
◦Weight and nal Time reading remains on the
display for ve seconds then return to zero.
◦Scale is now ready for another brew.
Zero (Tare) Funcon
• Zero funcon is disabled under “AUTO” mode.
• Under Manual mode: press the ZERO buon as needed.
Auto-o Seng
• Auto-o funcon is set to 180 seconds by default.
• Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• To change the Auto-o me seng or disable this funcon:
❶Turn o the scale.
❷ Press and hold the ON/OFF buon.
❸ While holding the ON/OFF buon, press the ZERO
buon 4-5 mes quickly unl “180” is shown on the
LCD display.
❹ Release both buons.
❺ Press the ZERO buon to switch between
“0/60/120/180”.
◦If “0” is selected, the Auto-o funcon will be
disabled.
❻ Aer choosing the desired me, press the ON/OFF
buon again.
❼ The display will show “PASS” to conrm this seng.
❽ The scale will turn o automacally.
Note:
◦If “60”, “120”, or “180” is chosen, the scale will
turn o aer the designated number of seconds of
inacvity.
◦If the Auto-o funcon is disabled, the scale will not
shut o on its own.
Please note: To maintain a longer baery life, turn o the scale
by pressing the ON/OFF buon aer each use.
Auto Mode A : (Automac Zero and Timer)
❶ Place brewing vessel on the scale plaorm.
◦Aer 3 seconds, weight reading goes to “0.0”
(Auto-tares).
❷ When the coee bean icon appears in the upper
le of the LCD screen, add coee grounds to the
brewing vessel.
◦Adjust the amount of coee grounds as needed.
❸ Press the RATIO buon.
◦The upper right of the LCD shows the calculated
target weight and the lower display shows zero.
❹ When the kele icon appears, begin adding water to
your brewing vessel.
◦The count-up mer begins automacally.
◦The Upper “Target” rate bar segments appear
at 10 second intervals.
◦The Lower “Actual” rate bar segments appear
as water is added.
◦Pour brewing water at a rate that keeps the
lower and upper bars even.
◦When the weight of the added water reaches
60g less than the calculated amount shown at
◦As the mer counts up, the Upper “Target” rate
bar segments appear at 10 second intervals.
◦As water is added, the Lower “Actual” rate bar
segments appear.
◦Numeric me is displayed in the lower le LCD.
❻ When the weight of the water added reaches 60g
less than the calculated amount shown at the top
right, the screen begins to ash. This means that you
are close to the nal amount of water needed.
❼ Once the lower display reading reaches the upper
display volume the enre display screen will change
color from orange to white.
❽ Stop adding water to the brewing vessel.
◦If the vessel is removed from the scale weight
in lower right will show a negave reading.
◦Timer will connue. Press the TIMER buon to
stop the mer.
◦Press the TIMER buon again to reset the mer
to zero.
◦Press the ZERO buon to clear the weight
reading and the rao.
Warning Messages
• “ ”: Overload
◦Quickly remove weight from plaorm to protect the
scale.
• “ ”: Unstable
◦Scale is not steady during start up. Please turn o
scale, set on a stable surface and restart scale.
◦Water is inside the scale. Shake out excess water
and let dry.
Washing Instrucons
This scale has been treated with a water-resistant nano-
coang. However, washing the scale under running water is
not recommended. Please follow these instrucons when
washing:
❶ Wash the exterior of the scale with a so, damp cloth
❷ Do not wash scale under running water.
❸ Leave scale to dry on a dish rack with LCD and buons
poinng upward.
Changing Units of Measurement
• Press the UNIT buon to switch between grams (g) and
ounces (oz).
◦Grams (g) is the default unit of measurement.
◦Units cannot be changed during the brewing process.
Changing The Set Rao
❶ Press and hold the RATIO buon for 3 seconds.
◦The rao will display blinking in the upper right of
the LCD.
❷ Press the RATIO buon unl the desired rao is displayed.
◦The default rao is 1:17 (add 1 part coee to 17 parts
water).
◦Scale has 7 pre-set raos: 1:14, 1:15, 1:16, 1:17,
1:18, 1:19, and 1:20
❸ Wait three seconds and the scale will automacally store
the new rao and return to the mode you were in last.
◦Rao cannot be changed once the brewing process
has begun.
Calibraon
❶ While the scale is o, press and hold the ON/OFF buon
and ZERO buon at the same me.
◦The LCD will read “CAL” in the upper right.
❷ Press the ZERO buon again and the LCD will ash
“500.0g”.
❸ Place a 500g calibraon weight onto the center of the
plaorm.
❹ The LCD will read “PASS” then return to the normal
weighing mode.
❻ Calibraon is complete.
Correct Disposal of this Product
This symbol indicates that this product should not be disposed of
with other household wastes throughout the European Union. To
prevent possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return your used device,
please use the return and collecon systems or contact the retailer
where the product was purchased. They can collect this product for
environmentally safe recycling.

DO NOT use liquid bleach or other harsh chemicals.
DO NOT use steel wool or abrasive sponges as this can
scratch the surface.
DO NOT submerge the scale.
Avoid pouring water directly into your scale, as water
may become trapped. If this occurs drying me may
exceed 4 hours.
Water drops on the LCD display will not interfere with
your weighing. These drops will dry and disappear.
If the scale displays “ ” or the readings jump aer
washing, then water is sll inside the scale. Simply shake
out the excess water and let your scale dry longer.
By following these washing instrucons, you will experience
shorter drying mes and your scale will provide you with years
of reliable service.
the top right of the LCD, the screen begins to
ash. This means that you are close to the nal
amount of water needed.
❺ Once the Target Weight is reached, the display color
will change from orange to white.
◦Timer connues to count up.
◦Weight reading will show actual weight even if
it is greater than the target weight.
❻ Remove brewing vessel aer brewing is complete.
◦Weight and nal Time reading remains on the
display for ve seconds then return to zero.
◦Scale is now ready for another brew.
Zero (Tare) Funcon
• Zero funcon is disabled under “AUTO” mode.
• Under Manual mode: press the ZERO buon as needed.
Auto-o Seng
• Auto-o funcon is set to 180 seconds by default.
• Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• To change the Auto-o me seng or disable this funcon:
❶Turn o the scale.
❷ Press and hold the ON/OFF buon.
❸ While holding the ON/OFF buon, press the ZERO
buon 4-5 mes quickly unl “180” is shown on the
LCD display.
❹ Release both buons.
❺ Press the ZERO buon to switch between
“0/60/120/180”.
◦If “0” is selected, the Auto-o funcon will be
disabled.
❻ Aer choosing the desired me, press the ON/OFF
buon again.
❼ The display will show “PASS” to conrm this seng.
❽ The scale will turn o automacally.
Note:
◦If “60”, “120”, or “180” is chosen, the scale will
turn o aer the designated number of seconds of
inacvity.
◦If the Auto-o funcon is disabled, the scale will not
shut o on its own.
Please note: To maintain a longer baery life, turn o the scale
by pressing the ON/OFF buon aer each use.
Auto Mode A : (Automac Zero and Timer)
❶ Place brewing vessel on the scale plaorm.
◦Aer 3 seconds, weight reading goes to “0.0”
(Auto-tares).
❷ When the coee bean icon appears in the upper
le of the LCD screen, add coee grounds to the
brewing vessel.
◦Adjust the amount of coee grounds as needed.
❸ Press the RATIO buon.
◦The upper right of the LCD shows the calculated
target weight and the lower display shows zero.
❹ When the kele icon appears, begin adding water to
your brewing vessel.
◦The count-up mer begins automacally.
◦The Upper “Target” rate bar segments appear
at 10 second intervals.
◦The Lower “Actual” rate bar segments appear
as water is added.
◦Pour brewing water at a rate that keeps the
lower and upper bars even.
◦When the weight of the added water reaches
60g less than the calculated amount shown at
◦As the mer counts up, the Upper “Target” rate
bar segments appear at 10 second intervals.
◦As water is added, the Lower “Actual” rate bar
segments appear.
◦Numeric me is displayed in the lower le LCD.
❻ When the weight of the water added reaches 60g
less than the calculated amount shown at the top
right, the screen begins to ash. This means that you
are close to the nal amount of water needed.
❼ Once the lower display reading reaches the upper
display volume the enre display screen will change
color from orange to white.
❽ Stop adding water to the brewing vessel.
◦If the vessel is removed from the scale weight
in lower right will show a negave reading.
◦Timer will connue. Press the TIMER buon to
stop the mer.
◦Press the TIMER buon again to reset the mer
to zero.
◦Press the ZERO buon to clear the weight
reading and the rao.
Warning Messages
• “ ”: Overload
◦Quickly remove weight from plaorm to protect the
scale.
• “ ”: Unstable
◦Scale is not steady during start up. Please turn o
scale, set on a stable surface and restart scale.
◦Water is inside the scale. Shake out excess water
and let dry.
Washing Instrucons
This scale has been treated with a water-resistant nano-
coang. However, washing the scale under running water is
not recommended. Please follow these instrucons when
washing:
❶ Wash the exterior of the scale with a so, damp cloth
❷ Do not wash scale under running water.
❸ Leave scale to dry on a dish rack with LCD and buons
poinng upward.
Changing Units of Measurement
• Press the UNIT buon to switch between grams (g) and
ounces (oz).
◦Grams (g) is the default unit of measurement.
◦Units cannot be changed during the brewing process.
Changing The Set Rao
❶ Press and hold the RATIO buon for 3 seconds.
◦The rao will display blinking in the upper right of
the LCD.
❷ Press the RATIO buon unl the desired rao is displayed.
◦The default rao is 1:17 (add 1 part coee to 17 parts
water).
◦Scale has 7 pre-set raos: 1:14, 1:15, 1:16, 1:17,
1:18, 1:19, and 1:20
❸ Wait three seconds and the scale will automacally store
the new rao and return to the mode you were in last.
◦Rao cannot be changed once the brewing process
has begun.
Calibraon
❶ While the scale is o, press and hold the ON/OFF buon
and ZERO buon at the same me.
◦The LCD will read “CAL” in the upper right.
❷ Press the ZERO buon again and the LCD will ash
“500.0g”.
❸ Place a 500g calibraon weight onto the center of the
plaorm.
❹ The LCD will read “PASS” then return to the normal
weighing mode.
❻ Calibraon is complete.
Correct Disposal of this Product
This symbol indicates that this product should not be disposed of
with other household wastes throughout the European Union. To
prevent possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return your used device,
please use the return and collecon systems or contact the retailer
where the product was purchased. They can collect this product for
environmentally safe recycling.

DO NOT use liquid bleach or other harsh chemicals.
DO NOT use steel wool or abrasive sponges as this can
scratch the surface.
DO NOT submerge the scale.
Avoid pouring water directly into your scale, as water
may become trapped. If this occurs drying me may
exceed 4 hours.
Water drops on the LCD display will not interfere with
your weighing. These drops will dry and disappear.
If the scale displays “ ” or the readings jump aer
washing, then water is sll inside the scale. Simply shake
out the excess water and let your scale dry longer.
By following these washing instrucons, you will experience
shorter drying mes and your scale will provide you with years
of reliable service.
the top right of the LCD, the screen begins to
ash. This means that you are close to the nal
amount of water needed.
❺ Once the Target Weight is reached, the display color
will change from orange to white.
◦Timer connues to count up.
◦Weight reading will show actual weight even if
it is greater than the target weight.
❻ Remove brewing vessel aer brewing is complete.
◦Weight and nal Time reading remains on the
display for ve seconds then return to zero.
◦Scale is now ready for another brew.
Zero (Tare) Funcon
• Zero funcon is disabled under “AUTO” mode.
• Under Manual mode: press the ZERO buon as needed.
Auto-o Seng
• Auto-o funcon is set to 180 seconds by default.
• Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• To change the Auto-o me seng or disable this funcon:
❶Turn o the scale.
❷ Press and hold the ON/OFF buon.
❸ While holding the ON/OFF buon, press the ZERO
buon 4-5 mes quickly unl “180” is shown on the
LCD display.
❹ Release both buons.
❺ Press the ZERO buon to switch between
“0/60/120/180”.
◦If “0” is selected, the Auto-o funcon will be
disabled.
❻ Aer choosing the desired me, press the ON/OFF
buon again.
❼ The display will show “PASS” to conrm this seng.
❽ The scale will turn o automacally.
Note:
◦If “60”, “120”, or “180” is chosen, the scale will
turn o aer the designated number of seconds of
inacvity.
◦If the Auto-o funcon is disabled, the scale will not
shut o on its own.
Please note: To maintain a longer baery life, turn o the scale
by pressing the ON/OFF buon aer each use.
Auto Mode A : (Automac Zero and Timer)
❶ Place brewing vessel on the scale plaorm.
◦Aer 3 seconds, weight reading goes to “0.0”
(Auto-tares).
❷ When the coee bean icon appears in the upper
le of the LCD screen, add coee grounds to the
brewing vessel.
◦Adjust the amount of coee grounds as needed.
❸ Press the RATIO buon.
◦The upper right of the LCD shows the calculated
target weight and the lower display shows zero.
❹ When the kele icon appears, begin adding water to
your brewing vessel.
◦The count-up mer begins automacally.
◦The Upper “Target” rate bar segments appear
at 10 second intervals.
◦The Lower “Actual” rate bar segments appear
as water is added.
◦Pour brewing water at a rate that keeps the
lower and upper bars even.
◦When the weight of the added water reaches
60g less than the calculated amount shown at
◦As the mer counts up, the Upper “Target” rate
bar segments appear at 10 second intervals.
◦As water is added, the Lower “Actual” rate bar
segments appear.
◦Numeric me is displayed in the lower le LCD.
❻ When the weight of the water added reaches 60g
less than the calculated amount shown at the top
right, the screen begins to ash. This means that you
are close to the nal amount of water needed.
❼ Once the lower display reading reaches the upper
display volume the enre display screen will change
color from orange to white.
❽ Stop adding water to the brewing vessel.
◦If the vessel is removed from the scale weight
in lower right will show a negave reading.
◦Timer will connue. Press the TIMER buon to
stop the mer.
◦Press the TIMER buon again to reset the mer
to zero.
◦Press the ZERO buon to clear the weight
reading and the rao.
Warning Messages
• “ ”: Overload
◦Quickly remove weight from plaorm to protect the
scale.
• “ ”: Unstable
◦Scale is not steady during start up. Please turn o
scale, set on a stable surface and restart scale.
◦Water is inside the scale. Shake out excess water
and let dry.
Washing Instrucons
This scale has been treated with a water-resistant nano-
coang. However, washing the scale under running water is
not recommended. Please follow these instrucons when
washing:
❶ Wash the exterior of the scale with a so, damp cloth
❷ Do not wash scale under running water.
❸ Leave scale to dry on a dish rack with LCD and buons
poinng upward.
Changing Units of Measurement
• Press the UNIT buon to switch between grams (g) and
ounces (oz).
◦Grams (g) is the default unit of measurement.
◦Units cannot be changed during the brewing process.
Changing The Set Rao
❶ Press and hold the RATIO buon for 3 seconds.
◦The rao will display blinking in the upper right of
the LCD.
❷ Press the RATIO buon unl the desired rao is displayed.
◦The default rao is 1:17 (add 1 part coee to 17 parts
water).
◦Scale has 7 pre-set raos: 1:14, 1:15, 1:16, 1:17,
1:18, 1:19, and 1:20
❸ Wait three seconds and the scale will automacally store
the new rao and return to the mode you were in last.
◦Rao cannot be changed once the brewing process
has begun.
Calibraon
❶ While the scale is o, press and hold the ON/OFF buon
and ZERO buon at the same me.
◦The LCD will read “CAL” in the upper right.
❷ Press the ZERO buon again and the LCD will ash
“500.0g”.
❸ Place a 500g calibraon weight onto the center of the
plaorm.
❹ The LCD will read “PASS” then return to the normal
weighing mode.
❻ Calibraon is complete.
Correct Disposal of this Product
This symbol indicates that this product should not be disposed of
with other household wastes throughout the European Union. To
prevent possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return your used device,
please use the return and collecon systems or contact the retailer
where the product was purchased. They can collect this product for
environmentally safe recycling.

DO NOT use liquid bleach or other harsh chemicals.
DO NOT use steel wool or abrasive sponges as this can
scratch the surface.
DO NOT submerge the scale.
Avoid pouring water directly into your scale, as water
may become trapped. If this occurs drying me may
exceed 4 hours.
Water drops on the LCD display will not interfere with
your weighing. These drops will dry and disappear.
If the scale displays “ ” or the readings jump aer
washing, then water is sll inside the scale. Simply shake
out the excess water and let your scale dry longer.
By following these washing instrucons, you will experience
shorter drying mes and your scale will provide you with years
of reliable service.
the top right of the LCD, the screen begins to
ash. This means that you are close to the nal
amount of water needed.
❺ Once the Target Weight is reached, the display color
will change from orange to white.
◦Timer connues to count up.
◦Weight reading will show actual weight even if
it is greater than the target weight.
❻ Remove brewing vessel aer brewing is complete.
◦Weight and nal Time reading remains on the
display for ve seconds then return to zero.
◦Scale is now ready for another brew.
Zero (Tare) Funcon
• Zero funcon is disabled under “AUTO” mode.
• Under Manual mode: press the ZERO buon as needed.
Auto-o Seng
• Auto-o funcon is set to 180 seconds by default.
• Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• To change the Auto-o me seng or disable this funcon:
❶Turn o the scale.
❷ Press and hold the ON/OFF buon.
❸ While holding the ON/OFF buon, press the ZERO
buon 4-5 mes quickly unl “180” is shown on the
LCD display.
❹ Release both buons.
❺ Press the ZERO buon to switch between
“0/60/120/180”.
◦If “0” is selected, the Auto-o funcon will be
disabled.
❻ Aer choosing the desired me, press the ON/OFF
buon again.
❼ The display will show “PASS” to conrm this seng.
❽ The scale will turn o automacally.
Note:
◦If “60”, “120”, or “180” is chosen, the scale will
turn o aer the designated number of seconds of
inacvity.
◦If the Auto-o funcon is disabled, the scale will not
shut o on its own.
Please note: To maintain a longer baery life, turn o the scale
by pressing the ON/OFF buon aer each use.
Auto Mode A : (Automac Zero and Timer)
❶ Place brewing vessel on the scale plaorm.
◦Aer 3 seconds, weight reading goes to “0.0”
(Auto-tares).
❷ When the coee bean icon appears in the upper
le of the LCD screen, add coee grounds to the
brewing vessel.
◦Adjust the amount of coee grounds as needed.
❸ Press the RATIO buon.
◦The upper right of the LCD shows the calculated
target weight and the lower display shows zero.
❹ When the kele icon appears, begin adding water to
your brewing vessel.
◦The count-up mer begins automacally.
◦The Upper “Target” rate bar segments appear
at 10 second intervals.
◦The Lower “Actual” rate bar segments appear
as water is added.
◦Pour brewing water at a rate that keeps the
lower and upper bars even.
◦When the weight of the added water reaches
60g less than the calculated amount shown at
◦As the mer counts up, the Upper “Target” rate
bar segments appear at 10 second intervals.
◦As water is added, the Lower “Actual” rate bar
segments appear.
◦Numeric me is displayed in the lower le LCD.
❻ When the weight of the water added reaches 60g
less than the calculated amount shown at the top
right, the screen begins to ash. This means that you
are close to the nal amount of water needed.
❼ Once the lower display reading reaches the upper
display volume the enre display screen will change
color from orange to white.
❽ Stop adding water to the brewing vessel.
◦If the vessel is removed from the scale weight
in lower right will show a negave reading.
◦Timer will connue. Press the TIMER buon to
stop the mer.
◦Press the TIMER buon again to reset the mer
to zero.
◦Press the ZERO buon to clear the weight
reading and the rao.
Warning Messages
• “ ”: Overload
◦Quickly remove weight from plaorm to protect the
scale.
• “ ”: Unstable
◦Scale is not steady during start up. Please turn o
scale, set on a stable surface and restart scale.
◦Water is inside the scale. Shake out excess water
and let dry.
Washing Instrucons
This scale has been treated with a water-resistant nano-
coang. However, washing the scale under running water is
not recommended. Please follow these instrucons when
washing:
❶ Wash the exterior of the scale with a so, damp cloth
❷ Do not wash scale under running water.
❸ Leave scale to dry on a dish rack with LCD and buons
poinng upward.
Changing Units of Measurement
• Press the UNIT buon to switch between grams (g) and
ounces (oz).
◦Grams (g) is the default unit of measurement.
◦Units cannot be changed during the brewing process.
Changing The Set Rao
❶ Press and hold the RATIO buon for 3 seconds.
◦The rao will display blinking in the upper right of
the LCD.
❷ Press the RATIO buon unl the desired rao is displayed.
◦The default rao is 1:17 (add 1 part coee to 17 parts
water).
◦Scale has 7 pre-set raos: 1:14, 1:15, 1:16, 1:17,
1:18, 1:19, and 1:20
❸ Wait three seconds and the scale will automacally store
the new rao and return to the mode you were in last.
◦Rao cannot be changed once the brewing process
has begun.
Calibraon
❶ While the scale is o, press and hold the ON/OFF buon
and ZERO buon at the same me.
◦The LCD will read “CAL” in the upper right.
❷ Press the ZERO buon again and the LCD will ash
“500.0g”.
❸ Place a 500g calibraon weight onto the center of the
plaorm.
❹ The LCD will read “PASS” then return to the normal
weighing mode.
❻ Calibraon is complete.
Correct Disposal of this Product
This symbol indicates that this product should not be disposed of
with other household wastes throughout the European Union. To
prevent possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return your used device,
please use the return and collecon systems or contact the retailer
where the product was purchased. They can collect this product for
environmentally safe recycling.

DO NOT use liquid bleach or other harsh chemicals.
DO NOT use steel wool or abrasive sponges as this can
scratch the surface.
DO NOT submerge the scale.
Avoid pouring water directly into your scale, as water
may become trapped. If this occurs drying me may
exceed 4 hours.
Water drops on the LCD display will not interfere with
your weighing. These drops will dry and disappear.
If the scale displays “ ” or the readings jump aer
washing, then water is sll inside the scale. Simply shake
out the excess water and let your scale dry longer.
By following these washing instrucons, you will experience
shorter drying mes and your scale will provide you with years
of reliable service.
the top right of the LCD, the screen begins to
ash. This means that you are close to the nal
amount of water needed.
❺ Once the Target Weight is reached, the display color
will change from orange to white.
◦Timer connues to count up.
◦Weight reading will show actual weight even if
it is greater than the target weight.
❻ Remove brewing vessel aer brewing is complete.
◦Weight and nal Time reading remains on the
display for ve seconds then return to zero.
◦Scale is now ready for another brew.
Zero (Tare) Funcon
• Zero funcon is disabled under “AUTO” mode.
• Under Manual mode: press the ZERO buon as needed.
Auto-o Seng
• Auto-o funcon is set to 180 seconds by default.
• Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• To change the Auto-o me seng or disable this funcon:
❶Turn o the scale.
❷ Press and hold the ON/OFF buon.
❸ While holding the ON/OFF buon, press the ZERO
buon 4-5 mes quickly unl “180” is shown on the
LCD display.
❹ Release both buons.
❺ Press the ZERO buon to switch between
“0/60/120/180”.
◦If “0” is selected, the Auto-o funcon will be
disabled.
❻ Aer choosing the desired me, press the ON/OFF
buon again.
❼ The display will show “PASS” to conrm this seng.
❽ The scale will turn o automacally.
Note:
◦If “60”, “120”, or “180” is chosen, the scale will
turn o aer the designated number of seconds of
inacvity.
◦If the Auto-o funcon is disabled, the scale will not
shut o on its own.
Please note: To maintain a longer baery life, turn o the scale
by pressing the ON/OFF buon aer each use.
Auto Mode A : (Automac Zero and Timer)
❶ Place brewing vessel on the scale plaorm.
◦Aer 3 seconds, weight reading goes to “0.0”
(Auto-tares).
❷ When the coee bean icon appears in the upper
le of the LCD screen, add coee grounds to the
brewing vessel.
◦Adjust the amount of coee grounds as needed.
❸ Press the RATIO buon.
◦The upper right of the LCD shows the calculated
target weight and the lower display shows zero.
❹ When the kele icon appears, begin adding water to
your brewing vessel.
◦The count-up mer begins automacally.
◦The Upper “Target” rate bar segments appear
at 10 second intervals.
◦The Lower “Actual” rate bar segments appear
as water is added.
◦Pour brewing water at a rate that keeps the
lower and upper bars even.
◦When the weight of the added water reaches
60g less than the calculated amount shown at
◦As the mer counts up, the Upper “Target” rate
bar segments appear at 10 second intervals.
◦As water is added, the Lower “Actual” rate bar
segments appear.
◦Numeric me is displayed in the lower le LCD.
❻ When the weight of the water added reaches 60g
less than the calculated amount shown at the top
right, the screen begins to ash. This means that you
are close to the nal amount of water needed.
❼ Once the lower display reading reaches the upper
display volume the enre display screen will change
color from orange to white.
❽ Stop adding water to the brewing vessel.
◦If the vessel is removed from the scale weight
in lower right will show a negave reading.
◦Timer will connue. Press the TIMER buon to
stop the mer.
◦Press the TIMER buon again to reset the mer
to zero.
◦Press the ZERO buon to clear the weight
reading and the rao.
Warning Messages
• “ ”: Overload
◦Quickly remove weight from plaorm to protect the
scale.
• “ ”: Unstable
◦Scale is not steady during start up. Please turn o
scale, set on a stable surface and restart scale.
◦Water is inside the scale. Shake out excess water
and let dry.
Washing Instrucons
This scale has been treated with a water-resistant nano-
coang. However, washing the scale under running water is
not recommended. Please follow these instrucons when
washing:
❶ Wash the exterior of the scale with a so, damp cloth
❷ Do not wash scale under running water.
❸ Leave scale to dry on a dish rack with LCD and buons
poinng upward.
Changing Units of Measurement
• Press the UNIT buon to switch between grams (g) and
ounces (oz).
◦Grams (g) is the default unit of measurement.
◦Units cannot be changed during the brewing process.
Changing The Set Rao
❶ Press and hold the RATIO buon for 3 seconds.
◦The rao will display blinking in the upper right of
the LCD.
❷ Press the RATIO buon unl the desired rao is displayed.
◦The default rao is 1:17 (add 1 part coee to 17 parts
water).
◦Scale has 7 pre-set raos: 1:14, 1:15, 1:16, 1:17,
1:18, 1:19, and 1:20
❸ Wait three seconds and the scale will automacally store
the new rao and return to the mode you were in last.
◦Rao cannot be changed once the brewing process
has begun.
Calibraon
❶ While the scale is o, press and hold the ON/OFF buon
and ZERO buon at the same me.
◦The LCD will read “CAL” in the upper right.
❷ Press the ZERO buon again and the LCD will ash
“500.0g”.
❸ Place a 500g calibraon weight onto the center of the
plaorm.
❹ The LCD will read “PASS” then return to the normal
weighing mode.
❻ Calibraon is complete.
Correct Disposal of this Product
This symbol indicates that this product should not be disposed of
with other household wastes throughout the European Union. To
prevent possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return your used device,
please use the return and collecon systems or contact the retailer
where the product was purchased. They can collect this product for
environmentally safe recycling.

DO NOT use liquid bleach or other harsh chemicals.
DO NOT use steel wool or abrasive sponges as this can
scratch the surface.
DO NOT submerge the scale.
Avoid pouring water directly into your scale, as water
may become trapped. If this occurs drying me may
exceed 4 hours.
Water drops on the LCD display will not interfere with
your weighing. These drops will dry and disappear.
If the scale displays “ ” or the readings jump aer
washing, then water is sll inside the scale. Simply shake
out the excess water and let your scale dry longer.
By following these washing instrucons, you will experience
shorter drying mes and your scale will provide you with years
of reliable service.
the top right of the LCD, the screen begins to
ash. This means that you are close to the nal
amount of water needed.
❺ Once the Target Weight is reached, the display color
will change from orange to white.
◦Timer connues to count up.
◦Weight reading will show actual weight even if
it is greater than the target weight.
❻ Remove brewing vessel aer brewing is complete.
◦Weight and nal Time reading remains on the
display for ve seconds then return to zero.
◦Scale is now ready for another brew.
Zero (Tare) Funcon
• Zero funcon is disabled under “AUTO” mode.
• Under Manual mode: press the ZERO buon as needed.
Auto-o Seng
• Auto-o funcon is set to 180 seconds by default.
• Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• To change the Auto-o me seng or disable this funcon:
❶Turn o the scale.
❷ Press and hold the ON/OFF buon.
❸ While holding the ON/OFF buon, press the ZERO
buon 4-5 mes quickly unl “180” is shown on the
LCD display.
❹ Release both buons.
❺ Press the ZERO buon to switch between
“0/60/120/180”.
◦If “0” is selected, the Auto-o funcon will be
disabled.
❻ Aer choosing the desired me, press the ON/OFF
buon again.
❼ The display will show “PASS” to conrm this seng.
❽ The scale will turn o automacally.
Note:
◦If “60”, “120”, or “180” is chosen, the scale will
turn o aer the designated number of seconds of
inacvity.
◦If the Auto-o funcon is disabled, the scale will not
shut o on its own.
Please note: To maintain a longer baery life, turn o the scale
by pressing the ON/OFF buon aer each use.
Auto Mode A : (Automac Zero and Timer)
❶ Place brewing vessel on the scale plaorm.
◦Aer 3 seconds, weight reading goes to “0.0”
(Auto-tares).
❷ When the coee bean icon appears in the upper
le of the LCD screen, add coee grounds to the
brewing vessel.
◦Adjust the amount of coee grounds as needed.
❸ Press the RATIO buon.
◦The upper right of the LCD shows the calculated
target weight and the lower display shows zero.
❹ When the kele icon appears, begin adding water to
your brewing vessel.
◦The count-up mer begins automacally.
◦The Upper “Target” rate bar segments appear
at 10 second intervals.
◦The Lower “Actual” rate bar segments appear
as water is added.
◦Pour brewing water at a rate that keeps the
lower and upper bars even.
◦When the weight of the added water reaches
60g less than the calculated amount shown at
◦As the mer counts up, the Upper “Target” rate
bar segments appear at 10 second intervals.
◦As water is added, the Lower “Actual” rate bar
segments appear.
◦Numeric me is displayed in the lower le LCD.
❻ When the weight of the water added reaches 60g
less than the calculated amount shown at the top
right, the screen begins to ash. This means that you
are close to the nal amount of water needed.
❼ Once the lower display reading reaches the upper
display volume the enre display screen will change
color from orange to white.
❽ Stop adding water to the brewing vessel.
◦If the vessel is removed from the scale weight
in lower right will show a negave reading.
◦Timer will connue. Press the TIMER buon to
stop the mer.
◦Press the TIMER buon again to reset the mer
to zero.
◦Press the ZERO buon to clear the weight
reading and the rao.
Warning Messages
• “ ”: Overload
◦Quickly remove weight from plaorm to protect the
scale.
• “ ”: Unstable
◦Scale is not steady during start up. Please turn o
scale, set on a stable surface and restart scale.
◦Water is inside the scale. Shake out excess water
and let dry.
Washing Instrucons
This scale has been treated with a water-resistant nano-
coang. However, washing the scale under running water is
not recommended. Please follow these instrucons when
washing:
❶ Wash the exterior of the scale with a so, damp cloth
❷ Do not wash scale under running water.
❸ Leave scale to dry on a dish rack with LCD and buons
poinng upward.
Changing Units of Measurement
• Press the UNIT buon to switch between grams (g) and
ounces (oz).
◦Grams (g) is the default unit of measurement.
◦Units cannot be changed during the brewing process.
Changing The Set Rao
❶ Press and hold the RATIO buon for 3 seconds.
◦The rao will display blinking in the upper right of
the LCD.
❷ Press the RATIO buon unl the desired rao is displayed.
◦The default rao is 1:17 (add 1 part coee to 17 parts
water).
◦Scale has 7 pre-set raos: 1:14, 1:15, 1:16, 1:17,
1:18, 1:19, and 1:20
❸ Wait three seconds and the scale will automacally store
the new rao and return to the mode you were in last.
◦Rao cannot be changed once the brewing process
has begun.
Calibraon
❶ While the scale is o, press and hold the ON/OFF buon
and ZERO buon at the same me.
◦The LCD will read “CAL” in the upper right.
❷ Press the ZERO buon again and the LCD will ash
“500.0g”.
❸ Place a 500g calibraon weight onto the center of the
plaorm.
❹ The LCD will read “PASS” then return to the normal
weighing mode.
❻ Calibraon is complete.
Correct Disposal of this Product
This symbol indicates that this product should not be disposed of
with other household wastes throughout the European Union. To
prevent possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return your used device,
please use the return and collecon systems or contact the retailer
where the product was purchased. They can collect this product for
environmentally safe recycling.
Other manuals for BWRRS1
2
Table of contents
Other BREWISTA Scale manuals

BREWISTA
BREWISTA Flex-a-Bowl Scale BSCFB2000 User manual

BREWISTA
BREWISTA Smart Scale II User manual

BREWISTA
BREWISTA BWRRS1 User manual

BREWISTA
BREWISTA Smart Brew BBCSWT User manual

BREWISTA
BREWISTA Smart Scale II User manual

BREWISTA
BREWISTA BWRRS1 User manual

BREWISTA
BREWISTA BSSRB2 User manual

BREWISTA
BREWISTA BSC2BNVWP User manual