BREWISTA Smart Scale II User manual

Customer Service
(North America):
1-888-538-8683
Local
(Wyoming, USA):
307-222-6086
Email:
help@mybrewista.com
READ THIS MANUAL PRIOR TO FIRST USE AND SAVE FOR
FUTURE REFERENCE
1-year Limited Warranty
Smart Scale™ II Components
❶ Plaorm
❷ ON/OFF buon
❸ MODE buon
❹ Baery Level Indicator
❺MODE indicator
❻Timer
❼LCD Readout
❽Weight (g)
❾ TARE buon
❿ TIME buon
Thank you for purchasing the Brewista Smart Scale™ II.
With proper care and treatment, this scale will provide
years of reliable service.
Fig. A: Illustraon of the Scale’s
Components and Controls
General Maintenance and Care
• Avoid exposure to extreme heat or cold.
◦Always allow your scale to acclimate to normal room
temperature before use.
• Keep your scale in a clean environment.
◦Excessive dust, dirt, vibraon, air currents, as well as
close proximity to other electronic equipment may
have an adverse eect on the accuracy and reliability
of the scale.
• Handle the scale with care.
◦Set all items to be weighed gently on the top of
the plaorm.
◦Although this scale is designed to be quite durable,
avoid rough treatment as this may permanently
damage the internal components.
◦Always avoid violent shaking and dropping.
◦This is a precision instrument and should be handled
as such.
Specicaons and Funcons
• Capacity: 2000g / 70 oz.
• Accuracy: 0.1g
• Units: grams (g) or Ounces (oz)
• Key funcons: ON/OFF, MODE, TARE, TIME
• Display: LCD with backlight
• Auto-o
◦Auto-o funcon is set to 180 seconds by default.
◦Auto-o can be set to 60 seconds, 120 seconds,
180 seconds, or disabled manually.
• Operang modes: Four (4) Automac modes and two
(2) Manual modes
• Power: Rechargable baery
Mode Seng
❶ Turn on the scale by pressing the ON/OFF buon.
❷ Wait unl the LCD displays zero.
❸ Press the MODE buon;
• The display will read “1”, “2”, “3”, “4”, “5”, or “6”.
• Press MODE again to toggle through these
6 modes.
Unit of Measurement
Switch the unit of measurement from grams to ounces by
holding the [MODE] buon down for about four seconds.
Repeat this step to toggle back to measuring in grams.
Operaon
Please note: When removing weight from scale, do not apply
downward force to the plaorm. Doing so may result in
inaccurate readings.
Mode 1:
(Fully Manual)
◦No Automac Funcons
◦User TARES and sets mer by pressing the appropriate
buons.
◦Timer is paused and restarted by pressing the TIME
buon again.
Mode 2:
(Auto-tare and Auto-mer with immediate mer start for
espresso preparaon)
❶Place cup on scale.
◦Time goes to 0’00” and weight goes to 0.0g.
◦Count-up mer starts.
❷ Remove cup aer brewing.
◦Last me and weight are displayed
◦Aer a ve (5) second delay, me returns to
0’00” and weight returns to 0.0g.
Mode 3:
(Auto-tare and manual mer start for espresso preparaon)
❶Place cup on scale.
◦Time goes to 0’00” and weight goes to 0.0g.
❷ Push buon on espresso machine to start the
shot and press orange TIME buon on scale
simultaneously.
◦Count-up mer starts.
❸ Remove cup aer brewing.
◦Weight reading remains on the display for ve
(5) seconds aer removing the cup.
◦Aer a ve (5) second delay, me returns to
0’00” and weight returns to 0.0g.
Mode 4:
(Auto-tare only; mer is not acve for espresso preparaon)
❶Place cup on scale.
◦Weight reading goes to 0.0g (Auto-tares).
❷ Push buon on espresso machine to start the shot.
❸Weight is displayed as added.
1
54 76 8
2 10
3 9
Smart Scale™ II
BSSRB2
g
Charging the Baery
❶Open the orange USB port cover and insert the small end
of a micro USB cable into this port.
❷ Insert the large end of the USB cable into a computer,
charging port or other device for charging your scale’s
baery.
❸ The scale will automacally turn on to verify the charging
connecon.
• We recommend turning o the scale manually at
this me to reduce charging me.
• Scale is fully charged when the baery icon has
4 bars.
Our scale baery comes with protecon circuit to avoid
over-charging. We strongly recommend unplugging
the scale when it is fully charged. Over-charging will
damage the baery.
Please charge the scale as soon as possible when the last
bar in the baery sign disappears, instead of waing
unl scale shuts o due to the power depleon.

Auto-o Seng
• Auto-o funcon is set to 180 seconds by default.
• Auto-o can be set to 60 seconds, 120 seconds, 180
seconds, or disabled manually.
• To change the Auto-o me seng or disable this funcon:
❶ Turn o the scale.
❷ Press and hold the ON/OFF buon.
❸ While holding the ON/OFF buon, press the
TARE buon 4-5 mes quickly unl “180”
is displayed.
❹ Release both buons.
❺ Press the MODE buon to switch between
“0/60/120/180”.
◦If “0” is selected, the Auto-o funcon will
be disabled.
❻ Aer choosing the desired me, press the ON/OFF
buon again.
❼ The display will show “PASS” to conrm this seng.
❽ The scale will turn o automacally.
Note:
◦If “60”, “120”, or “180” is chosen, the scale will
turn o aer the designated number of seconds of
inacvity.
◦If the Auto-o funcon is disabled, the scale will
not shut o on its own.
Please note: To maintain a longer baery life, please
turn o the scale by pressing the ON/OFF buon aer
each use.
Silicone Pad
Use of the silicone pad is oponal. It is included to provide
addional water resistance. It also prevents slight weight
variaons caused by abrupt temperature changes on the
plaorm.
• Place the silicone pad onto the plaorm with the Brewista
logo oriented to be read le to right.
• Ensure that the pad covers the plaorm completely
without interfering with plaorm travel.
• The silicone pad is dishwasher safe (top rack).
Washing Instrucons
This scale has been treated with a water-resistant nano-
coang. However, washing the scale under running water is
not recommended. Please follow these instrucons to clean
your scale:
❶ Wash the exterior of the scale with a so, damp cloth.
❷Do not wash scale under running water.
❸ Leave scale to dry on a dish rack with LCD and buons
poinng up.
DO NOT use liquid bleach or other harsh chemicals.
DO NOT use steel wool or abrasive sponges as this can
scratch the surface.
DO NOT submerge the scale.
Avoid pouring water directly into your scale, as water
may become trapped. If this occurs drying me may
exceed 4 hours.
Water drops on the LCD display will not interfere with
your weighing. These drops will dry and disappear.
If the scale displays “UNST” or the readings jump aer
washing, then water is sll inside the scale. Simply shake
out the excess water and let your scale dry longer.
By following these washing instrucons, you will experience
shorter drying mes and your scale will provide you with years
of reliable service.
Mode 6:
(for Pour Over Brewing)
❶ Place brew vessel on the scale plaorm.
◦Weight reading goes to 0.0g (Auto-tares).
❷ Add coee grounds to the brewing vessel.
❸ Adjust the amount of coee grounds to the desired
weight.
❹ Once plaorm is stable, press the TARE buon.
❺ Start adding water to the coee grounds.
◦Count-up mer starts.
❻ Remove cup aer brewing.
◦Weight reading remains on the display for ve
(5) seconds aer removing the cup.
◦Aer a ve (5) second delay, me returns to
0’00” and weight returns to 0.0g.
Tare Funcon
• Tare funcon is disabled under “AUTO” mode.
• Under Manual modes: press the TARE buon when
needed.
❹ Remove cup aer brewing.
◦Weight reading remains on the display for ve
(5) seconds aer removing the cup.
◦Aer a ve (5) second delay, weight returns to
0.0g.
Mode 5:
(Auto-tare and Auto-mer with mer starng when liquid hits
the cup for espresso preparaon.)
❶Place cup on the scale.
◦Weight reading goes to 0.0g (Auto-tares).
❷ Push buon on espresso machine to start the shot.
◦When liquid hits the cup the mer automacally
starts to count up. To pause the mer, press
TIME buon.
❸ Remove cup aer brewing.
◦Weight reading remains on the display for ve
(5) seconds aer removing the cup.
◦Aer a ve (5) second delay, me returns to
0’00” and weight returns to 0.0g.
Calibraon
❶ While the scale is o, press and hold ON/OFF buon and
MODE buon at the same me unl LCD shows internal
code, then release the two buons.
❷ Press the MODE buon again.
◦The LCD will read “0.0g”.
❸ Place a 500g weight onto the center of the plaorm
◦The LCD will show internal code.
❹ Press MODE buon again.
❺The LCD will read “PASS”.
❻ Calibraon is complete.
Warning Messages
• “EEEE”: Overload
◦Quickly remove weight from plaorm to protect
the scale.
• “UNST”:
◦Scale is not steady during start up. Please turn o
scale, set on a stable surface and restart scale.
◦Water is inside the scale. Shake out excess water
and let dry.
Other manuals for Smart Scale II
1
Other BREWISTA Scale manuals

BREWISTA
BREWISTA BWRRS1 User manual

BREWISTA
BREWISTA BWRRS1 User manual

BREWISTA
BREWISTA Smart Brew BBCSWT User manual

BREWISTA
BREWISTA BWRRS1 User manual

BREWISTA
BREWISTA Flex-a-Bowl Scale BSCFB2000 User manual

BREWISTA
BREWISTA BSC2BNVWP User manual

BREWISTA
BREWISTA Smart Scale II User manual

BREWISTA
BREWISTA BSSRB2 User manual