Brink Renovent Excellent 300 User manual

Heat recovery appliance
Renovent Excellent 300/400 (Plus)
STORE NEAR THE APPLIANCE
Installation instructions
Use of this appliance is not permitted for persons, including children, with limited intellectual abilities, serious physical limitations or
lack of experience and knowledge, unless they are supervised by, or have received instructions of how to use the appliance from,
a person who is responsible for their safety.
Children must be supervised to ensure that they do not play with the appliance.

Renovent Excellent
1
1.1
1.2
2
3
3.1
3.2
3.3
3.4
3.4.1
3.4.2
4
4.1
4.2
4.3
4.4
5
5.1
5.2
5.3
5.4
5.5
5.5.1
5.5.2
5.5.3
6
6.1
6.2
6.2.1
6.2.2
6.2.3
6.3
6.4
6.5
7
7.1
7.2
7.3
7.4
8
8.1
8.2
Delivery..........................................................
Scope of delivery............................................
Accessories Renovent Excellent ....................
Application....................................................
Version...........................................................
Techni c al in f or m at i on . . .. . .. . .. .. . .. . .. . .. .. . .. . .. .........
Fan graphs .....................................................
Exploded view appliance................................
Connections and dimensions .........................
Renovent Excellent right-handed version.......
Renovent Excellent left-handed version.........
Operation.......................................................
Description......................................................
Bypass conditions...........................................
Frost safety.....................................................
Renovent Excellent Plus.................................
Installation.....................................................
Installation general .........................................
Placing the appliance .....................................
Connecting the condensate discharge ...........
Connecting ducts............................................
Electric connections........................................
Connection of the power plug.........................
Connecting the multiple switch.......................
Connection eBus or OpenTherm connector...
Display...........................................................
General explanation control panel..................
Operating mode..............................................
Status system fan...........................................
.. . .. . . .. . .. . . .. . .. . . .. . .. . ... . .. . ... . ..
Message text for operating mode...................
Settings menu.................................................
Readout menu................................................
Service menu..................................................
Rwvvkpi"kpvq"qrgtcvkqp ..................................
Switching the appliance on and off.................
Setting the air quantity....................................
Other settings installer....................................
Factory setting................................................
Fault...............................................................
Trouble shooting.............................................
Display codes .................................................
1
1
2
5
6
6
8
9
10
10
11
12
12
12
12
12
13
13
13
13
13
15
15
15
15
16
16
17
17
17
18
19
20
21
22
22
23
23
23
24
24
24
Table of contents
9
9.1
9.2
10
10.1
10.2
11
11.1
11.2
11.2.1
11.2.2
11.2.3
11.2.4
11.3
11.4
11.5
11.6
11.7
11.8
12
12.1
12.2
13
Maintenance................................................
Filter cleaning ..............................................
Maintenance.................................................
Electric diagrams........................................
Basic diagram...............................................
Wiring diagram .............................................
Electric connections accessories.............
Connections connectors...............................
Connection examples multiple switch...........
...............
-
tion)...............................................................
-
tion................................................................
Additional multiple switch wireless remote
control...........................................................
Coupling through eBus; all appliances equal
...................................................
Connecting RH(huminity)-sensor ...........
Wiring diagram postheater connection (only
for Renovent Excellent Plus) ........................
Connection example geo heat exchanger
(only possible for the Renovent Excellent
Plus) .............................................................
Connecting external switch contact (only
possible for Renovent Excellent Plus)..........
Connection to 0-10 V input (only possible for
Renovent Excellent Plus) .............................
Service.........................................................
Exploded view ..............................................
Service articles .............................................
Setting values .............................................
Declaration of conformity..............................
26
26
27
29
29
30
31
31
32
32
32
32
32
33
33
34
35
36
37
38
38
39
40
42

Renovent Excellent 1
Delivery Chapter 1
Before starting installation of the heat recovery unit, check that it has been supplied complete and undamaged.
The scope of delivery of the heat recovery unit Renovent Excellent includes the following components:
|
Heat recovery appliance type Renovent Excellent
~
Wall mounting bracket kit containing:
¡
PVC condensate discharge connection containing:
¢
Documentation set consisting:
1.1 Scope of delivery
1
2
4
3

2 Renovent Excellent
Chapter 1 Delivery
1.2 Accessories Renovent Excellent
Article description Article code
Synthetic duct Ø150 mm / Length 2250 mm (box of 4)
Synthetic duct Ø180 mm / Length 2250 mm (box of 4)
200121
200131
Synthetic bend 90° Ø150 mm (box of 8)
Synthetic bend 90° Ø180 mm (box of 8)
200122
200132
Synthetic bend 45° Ø150 mm (box of 8)
Synthetic bend 45° Ø180 mm (box of 8)
200123
200133
Synthetic bend 30° Ø150 mm (box of 8)
Synthetic bend 30° Ø180 mm (box of 8)
200124
200134
Synthetic bend 15° Ø150 mm (box of 8)
Synthetic bend 15° Ø180 mm (box of 8)
200125
200135
Synthetic coupler Ø150 mm (box of 1)
Synthetic coupler Ø180 mm (box of 1)
200128
200138
Acoustic duct Ø150 mm / Length 10 m
Acoustic duct Ø160 mm / Length 10 m
Acoustic duct Ø180 mm / Length 10 m
207750
207760
207780
Acoustic duct Ø150 mm / Finished length 1 m (1)
Acoustic duct Ø160 mm / Finished length 1 m (1)
Acoustic duct Ø180 mm / Finished length 1.5 m (1)
207751
207761
207782
Mounting support Excellent 300/400 217035
Electric postheater Excellent 300 Ø 160mm
Electric postheater Excellent 400 Ø 180mm
310630
310650
Electric (extra) preheater Excellent 300 Ø 160mm
Electric (extra) preheater Excellent 400 Ø 180mm
310640
310660

Renovent Excellent 3
Delivery Chapter 1
Article description Article
code
Splitter RJ12 510472
CO
2
sensor surface-mounted 511396
Transmitter wireless remote control 2 positions (with. battery) 531785
Transmitter wireless remote control 4 positions (with. battery) 531786
Receiver wireless remote control (for battery version) 531787
Kit wireless remote control 2 positions (1 transmitter & 1 receiver) 531788
Kit wireless remote control 4 positions (1 transmitter & 1 receiver) 531789
Delivered with insert plate and cover frame 540214
Delivered with insert plate and cover frame 540262
648550
648560
648570
Set foamrings Ø150 mm ö"Ø160 mm (4 pieces) 217000
Ventilation roof sleeve D150 (suitable for supply, under the tiles ; insulated)
Ventilation roof sleeve D180 (suitable for supply, under the tiles ; insulated)
648620
648680
Ventilation sleeve exterior wall D150 (suitable for supply,insulated)
Ventilation sleeve exterior wall D180 (suitable for supply,insulated)
648690
648690
Ventilation roof sleeve D150 (suitable for extract; insulated)
Ventilation roof sleeve D166 (suitable for extract; insulated)
Ventilation roof sleeve D180 (suitable for extract; insulated)
648710
648700
648770
Other manuals for Renovent Excellent 300
1
This manual suits for next models
1
Table of contents
Other Brink Heating System manuals
Popular Heating System manuals by other brands

Truma
Truma Trumatic E 2400 E Operating instructions and installation instructions

Aqua-Hot
Aqua-Hot 200 Series installation manual

Vent-Axia
Vent-Axia HR100S Installation and maintenance instructions

aerauliqa
aerauliqa QR350ABP installation manual

WatchGas
WatchGas ATEX BEACON manual

Lampoassa
Lampoassa 203GT user manual