BRK electronic PC910B User manual

CAT. PC910B
10-YEAR
LITHIUM POWER
10 years of continuous protection.
No battery change required. Provides
audible notice when alarm has reached
its end of life.
TAMPERPROOF
SEALED ALARM
Powercell cannot be removed.
ELECTROCHEMICAL CO
SENSOR
Most accurate technology available for
detecting carbon monoxide as com-
pared to other sensing technologies.
PHOTOELECTRIC
Photoelectric technology is gener-
ally more sensitive at detecting large
particles, which tend to be produced in
greater amounts by smoldering fires.
SILENCE FEATURE
Silences nuisance alarms.
TAMPER RESISTANT
Locks alarm to mounting bracket.
Perfect for apartment, dormitory or
hotel applications.
Description:
BRK Model PC910 is a battery operated, 3V lithium power cell single station smoke
and CO alarm specifically designed for residential and institutional applications
including sleeping rooms of hospitals, hotels, motels, dormitories, and other mul-
tifamily dwellings as defined in standard NFPA 101. Model PC910 has been fully
tested and complies with, UL217, UL2034 CSFM, NFPA 72, NFPA 720, NFPA 101
and other agencies that model their codes after the above agencies. It meets
building codes where tamperproof 10-year sealed lithium battery operated smoke
and CO alarms are required and with model building codes published by the ICC.
BRK Model PC910 is a state of the art smoke and CO combination alarm designed
to provide early warning of a fire or carbon monoxide danger. It features a fully
insect screened Photoelectric smoke sensing chamber and an electrochemical
CO sensor, an 85dB horn, a sealed 10-year lithium power cell power supply that
is permanently installed, a full function test switch, a silence feature to silence
unwanted nuisance alarms, a red LED light that indicates DC power or alarm. The
tamperproof design will not allow the powercell to be removed. The low power
warning indicator will cause the alarm to “chirp” when it reaches the end of its
service life and needs to be replaced. Upon end of life, the unit meets UL require-
ments for disabling the alarm and non-reinstallation of unit to mounting bracket.
It also features a tamper resistant locking pin that locks alarm to the mounting
bracket. Perfect for apartment, dormitory or hotel applications. The compact, low
profile design complements any décor. Designed for wall or ceiling mounting. In-
cludes mounting anchors and screws.
Sealed 3V Lithium Power Cell
10-YEAR SEALED
SMOKE & CO
COMBO
ALARM
CAT. PC910B
ARCHITECTURAL AND ENGINEERING SPEC
TECHNICAL SPECS
SHIPPING SPECS
INSTALLATION OF ALARM
The smoke and CO combination alarm shall be a BRK Model PC910 and shall provide at
a minimum the following features and functions:
1. A photoelectric smoke sensing chamber and an electrochemical CO sensor.
2. The unit shall be capable of self restoring.
3. A fully screened sensing chamber to resist entry of small insects thereby reducing
the probability of unwanted alarms.
4. Powered by a sealed 10-year lithium powercell with a tamperproof design. The
tamperproof design shall not allow the powercell to be removed. A low power
warning indicator shall cause the alarm to “chirp” when it reaches the end of
its service life and needs to be replaced. Upon end of life, the unit shall meet UL
requirements for disabling the alarm and the non-reinstallation of unit to
mounting bracket.
5. A visual LED power-on indicator to confirm unit is receiving power or is in alarm.
6. A full function test button. The test button should check all alarm functions by
stimulating the chamber to simulate a smoke and CO condition, causing the unit to
alarm.
7. Two Silence features - Low Battery Silence: Silence low battery chirp for up to 8
hours. Alarm Silence: Temporarily silence unwanted nuisance alarms.
8. A tamper resistant locking pin that locks alarm to the mounting bracket.
9. The unit shall be capable of operating between 40°F (4°C) and 100°F (38°C) and
relative humidity between 10% and 90%.
10. The unit shall contain mounting hardware and shall be listed for wall or ceiling
mounting.
11. The unit shall at a minimum meet the requirements of UL217, UL2034, CSFM, NFPA
72, NFPA 720, NFPA 101, ICC.
Alarm Dimensions: 4.92”L x 4.92”W x 0.96”H
Weight: 5.1 oz
Operating Voltage: 3V Lithium Power Cell
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence: Electronically simulates smoke or CO condition,
causing the unit to alarm. Press and hold test/silence
button.
Alarm Reset: Automatic when smoke or CO clears
Smoke Sensor: Photoelectric
CO Sensor: Electrochemical
Indicator Lights/Sounds:
DC Power: Intermittent Red LED
Local Alarm: Audio Alarm, rapidly flashing red LED
Listing: Listed to UL217 and UL2034 Standards
Individual Carton Dimensions 4.94 ”L x 1.31”D x 6.63”H
Weight 0.43 lbs.
Cube 0.03 ft3
UPC 0 29054 01185 5
Master Carton Dimensions 10.50 ”L x 8.13”W x 6.38”H
Master Pack 12
Weight 2.9 lbs.
Cube: 0.32 ft3
I2of5: 200 29054 01185 9
Pallet Information
Cases per Layer 19
Number of Layers: 8
Cases per Pallet: 152
Units per Pallet: 912
Cube: 62.2 ft3
Weight: 504 lbs.
©2013 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)
3901 Liberty Street Road
Aurora, IL 60504-8122
All rights reserved
First Alert is a registered trademark of the First Alert Trust
BRK is a registered trademark of BRK Brands, Inc.
CM3181
brkelectronics.com
Installation of this smoke alarm must conform to NFPA 72. Always check your local
building codes. Follow all instructions for placement as outlined in the user’s manual in
sections titled “Recommended Locations for Smoke Alarms” and “Locations to Avoid for
Smoke Alarms”.
THE PARTS OF THIS SMOKE & CO ALARM
1. Test/Silence button
2. LED alarm light
3. Activate/Deactivate Switch
4. Locking tab slot (Break out Tab)
5. Locking tab
6. Mounting bracket
7. “This way up” Arrow
8. Mounting Slots
MOUNTING
BRACKET
TOP VIEW SIDE VIEW
4.9” 4.3”
4.9”
1”
4.3”
1
2
3
4
5
6
7
8
8
Activate/Deactivate
Switch-Detail
Break and remove tab then
slide switch to deactivate
OFF - ON - DISCHARGE

Other BRK electronic Smoke Alarm manuals

BRK electronic First Alert Dicon M300 User manual

BRK electronic

BRK electronic First Alert Dicon M300 User manual

BRK electronic First Alert P1010 User manual

BRK electronic

BRK electronic First Alert P1010 User manual

BRK electronic 4010YR User manual

BRK electronic

BRK electronic 4010YR User manual

BRK electronic PRC710B User manual

BRK electronic

BRK electronic PRC710B User manual

BRK electronic SC9120LBL User manual

BRK electronic

BRK electronic SC9120LBL User manual

BRK electronic 5919/5919 TH User manual

BRK electronic

BRK electronic 5919/5919 TH User manual

BRK electronic Smoke & CO PRC700B User manual

BRK electronic

BRK electronic Smoke & CO PRC700B User manual

BRK electronic 9120LBLA User manual

BRK electronic

BRK electronic 9120LBLA User manual

BRK electronic 7030BSLA User manual

BRK electronic

BRK electronic 7030BSLA User manual

BRK electronic 100S User manual

BRK electronic

BRK electronic 100S User manual

BRK electronic 83RN User manual

BRK electronic

BRK electronic 83RN User manual

BRK electronic SA320B User manual

BRK electronic

BRK electronic SA320B User manual

BRK electronic SA350B User manual

BRK electronic

BRK electronic SA350B User manual

BRK electronic SC7010B User manual

BRK electronic

BRK electronic SC7010B User manual

BRK electronic P H O T O & I O N 3120B User manual

BRK electronic

BRK electronic P H O T O & I O N 3120B User manual

BRK electronic SL177 User manual

BRK electronic

BRK electronic SL177 User manual

BRK electronic 9120 Series User manual

BRK electronic

BRK electronic 9120 Series User manual

BRK electronic 4010YR User manual

BRK electronic

BRK electronic 4010YR User manual

BRK electronic First Alert P1010 User manual

BRK electronic

BRK electronic First Alert P1010 User manual

BRK electronic 86RACEN User manual

BRK electronic

BRK electronic 86RACEN User manual

BRK electronic 9120LBLA User manual

BRK electronic

BRK electronic 9120LBLA User manual

BRK electronic Dicon M300 User manual

BRK electronic

BRK electronic Dicon M300 User manual

BRK electronic SMOKE & CO SC7010B User manual

BRK electronic

BRK electronic SMOKE & CO SC7010B User manual

BRK electronic 83RN User manual

BRK electronic

BRK electronic 83RN User manual

Popular Smoke Alarm manuals by other brands

First Alert 83R user manual

First Alert

First Alert 83R user manual

System Sensor 1424 Installation and maintenance instructions

System Sensor

System Sensor 1424 Installation and maintenance instructions

Bosch DS240 installation instructions

Bosch

Bosch DS240 installation instructions

Metrona RM 680110 User information

Metrona

Metrona RM 680110 User information

teko Astra-421 Operation manual

teko

teko Astra-421 Operation manual

Robotronics Buzz E operating manual

Robotronics

Robotronics Buzz E operating manual

aguilera electronica AE/SA-OPI Technical manual

aguilera electronica

aguilera electronica AE/SA-OPI Technical manual

AirSense Stratos Micra 10 Installer's handbook

AirSense

AirSense Stratos Micra 10 Installer's handbook

Air Products MSR-50A installation guide

Air Products

Air Products MSR-50A installation guide

Firex AD user manual

Firex

Firex AD user manual

Ei Electronics Ei151TL User instruction

Ei Electronics

Ei Electronics Ei151TL User instruction

Inovonics EE1265 Installation and operation manual

Inovonics

Inovonics EE1265 Installation and operation manual

Hochiki SLR-24 installation instructions

Hochiki

Hochiki SLR-24 installation instructions

Shelly Plus Smoke User and safety guidelines

Shelly

Shelly Plus Smoke User and safety guidelines

Inovonics EN1244 installation instructions

Inovonics

Inovonics EN1244 installation instructions

pyrexx PX-1 Operating, installation and maintenance manual

pyrexx

pyrexx PX-1 Operating, installation and maintenance manual

System Sensor Sounder Base B501BH Installation and maintenance instructions

System Sensor

System Sensor Sounder Base B501BH Installation and maintenance instructions

CALECTRO UG-3-A4O Installation instruction

CALECTRO

CALECTRO UG-3-A4O Installation instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.