Broadata LBH-H/O-EAD-R-ICP User manual

LBH-H/O-EAD-R-ICP
LINK BRIDGETM HBASET/HDMI
RECEIVER SYSTEM WITH EXTERNAL AUDIO
AND INLINE CONTROL PROCESSOR
BCI reserves the right to make changes to the products described herein without prior
notice or consent. No liability is assumed as a result of their use or application. All
rightsreserved.
©2015 Broadata Communications, Inc.

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
SAFETY INSTRUCTIONS AND
COMPLIANCE DECLARATIONS
PLEASE OBSERVE THE FOLLOWING SAFETY
PRECAUTIONS
SURGE PROTECTION DEVICE RECOMMENDED
This product contains sensitive electrical components that may be
damaged by electrical spikes, surges, electric shock, lightning strikes,
etc. Use of surge protection systems is highly recommended in order
to protect and extend the life of your equipment.

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
Broadata Technical Support, (800) 214-0222
4
TABLE OF CONTENTS
1.0 PRODUCT DESCRIPTION ..............................................5
2.0 OPERATION CONTROL AND FUNCTIONS ...................6
2.1 RECEIVER EXTENDER FRONT AND REAR PANEL.....6
2.2 ICP FRONT AND REAR PANEL .....................................7
3.0 CONNECTOR PINOUT ASSIGNMENT ...........................8
3.1 EXTENDER ......................................................................8
3.1.1 SERIAL DATA INTERFACE............................................8
3.1.2 STATUS LEDS ...............................................................9
3.2 ICP .................................................................................10
3.3 LB-KP8 ...........................................................................11
4.0 LB-ICP WEB SERVER DESCRIPTION .........................13
5.0 SPECIFICATIONS...........................................................39
6.0 SERVICE PROCEDURE ................................................42
6.1 REPLACEMENT POLICY ..............................................42
6.2 RETURN AND REPAIR SERVICE .................................42
7.0 LIMITED WARRANTY ....................................................43

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
1.0 PRODUCT DESCRIPTION
Overall
•A selectable HDBT or HDMI receiver with multiple control I/O
ports
•Provides in-line control I/O paths
Receiver
•Receive HDMI, audio, IR, and RS-232 up to 100 meters over 1
CAT-5e/6 cable
•Supports video resolutions up to 1080p 60Hz and
1920 x 1200@60Hz, as well as 4K@30Hz
•Supports HDMI w/embedded audio extraction
•EDID pass-through support, automatically detects the factory
setting of the connected display
Control
•Control I/O ports contain:
- two (2) RS-232
- two (2) Relay
- two (2) Digital I/O
- one (1) IR
- one (1) Ethernet
•Control and monitorAV devices using a standard Ethernet
network (Smart phone or PC) or RS-232 (keypad)
•Front panel port status indicators
•Userfriendlycustomizable controlconfigurationsvia built-in
web server
ORDERING INFORMATION
LBH-H/O-EAD-R-M-SC-ICP LinkBridgeHDBT/HDMI Receiver
w/Control I/O Ports

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
Broadata Technical Support, (800) 214-0222
6
2.0 OPERATION CONTROLSAND FUNCTIONS
2.1 Receiver Extender Front and Rear Panel
1. Power/Link: The red LED indicates the unit is powered up.
The green LED indicates that the unit has a good HDBT
connection.
112
In
12
11
RS232
2
2
Out
2
2
1
I / O
IR
REM
2
1
+5V
In
C
NC
NO
NC
NO
C
Out
AUXRELAY
InIn
11
2
Out
2
DATA
1
2
1
2
DATA
DATA
IR
LBH-H/O-EAD-RX-ICP
PWR/ LINK
L / RSPDIF
AUDIO
HDMI IN
HDMI
5
OPT
HDMI OUT
AUTO
1
Front
RESET
Out In
IR
CONFIG
SW
ON
11
LAN
+24VDC
1.25 A
LINK
Rear
ICP Extender
ICP
Extender
112
In
12
11
RS232
2
2
Out
2
2
1
I / O
IR
REM
2
1
+5V
In
C
NC
NO
NC
NO
C
Out
AUXRELAY
InIn
11
2
Out
2
DATA
1
2
1
2
DATA
DATA
IR
LBH-H/O-EAD-RX-ICP
PWR/ LINK
L / RSPDIF
AUDIO
HDMI IN
HDMI
5
OPT
HDMI OUT
AUTO
1
Front
RESET
Out In
IR
CONFIG
SW
ON
11
LAN
+24VDC
1.25 A
LINK
Rear
10
1
23
4
56
7
89
HDCP
SPDIF
L/R
11
EDID
Loc
Rem
12 13
14 15

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
2. HDCP LED: The blue LED is lighted when HDCP video is
present.TheblueLEDblinks whennon-HDCPvideo ispresent.
3. SPDIFLED:LightedwhencorrespondingSPDIFaudiois active.
4. DATALEDs: Lightedwhencorrespondinginputoroutputports
are active.
5. L/R LED: Lighted when corresponding audio is active.
6. DATA: RS-232 pass-through data connector.
7. IR: IR pass-through IR connector.
8. SPDIF: SPDIF audio output connector.
9. L/R: L/R audio output connector.
10. HDMI IN: HDMI video input connector.
11. HDMI OUT: HDMI video output connector.
12. EDID Selection: Select Local or Remote EDID (for HDMI IN)
13. Input Video Selection: Reserved.
14. HDBT: HDBT CAT-5e/6/7 cable connector.
2.2 ICP Front and Rear Panel
1. Digital I/O: Digital input/output ports.
2. DigitalI/O LEDs:Lightwhen thecorresponding portsare active
high.
112
In
12
11
RS232
2
2
Out
2
2
1
I / O
IR
REM
2
1
+5V
In
C
NC
NO
NC
NO
C
Out
AUXRELAY
InIn
11
2
Out
2
DATA
1
2
1
2
DATA
DATA
IR
LBH-H/O-EAD-RX-ICP
PWR/ LINK
L / RSPDIF
AUDIO
HDMI IN
HDMI
5
OPT
HDMI OUT
AUTO
1
ICP Front
RESET
Out In
IR
CONFIG
SW
ON
11
LAN
+24VDC
1.25 A
LINK
ICP Rear
10
12
34
56
7
89
HDCP
SPDIF
L/R
11
EDID
Loc
Rem
12
13
14 15 16 17

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
Broadata Technical Support, (800) 214-0222
8
3. RS-232: Serial port to control devices.
4. RS-232 LEDs: Light when the corresponding RS-232 ports
are active.
5. REM LED: Light when the unit is set as a remote unit.
6. IR LED: Light when the IR out are active.
7. RELAYLED: Light whenthecorresponding,normallyopen pins,
are closed.
8. RELAY: Normally open and normally closed relay ports.
9. AUX-In and AUX-Out: Reserved.
10. DC24V: DC power input connector.
11. IR Out: IR blaster port.
12. SW: The unit configuration dip switch
13. IR Learner: Built-in IR receiver for IR learning.
14. IR Learner LED: Lighted when the unit is IR learning mode.
15. CONFIG: Configuration/keypad port
16. LAN: Ethernetconnector.
17. RESET: Press the button to reset the device back to factory
default settings.
3.0 CONNECTOR PINOUT ASSIGNMENT
3.1 Extender
3.1.1 Serial Data Interface
Each LBH-H/O-EAD-R-ICP unit can be used for RS-232 and
IR interface.
RS-232/ IR Data
The LBH-H/O-EAD-R-ICP transmits two channels of data
signals. Follow the procedures for installing data terminal
devices.
1. Label and connect one serial data cable to the user’s
RS-232 or IR device.

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
2. Connect the other end of this cable to the front panel
data terminal block connector on the
LBH-H/O-EAD-R-ICP (see below).
3.1.2 Status LED’s
Additional status LED’s are provided for the user to indicate
the presence of HDCP video, audio presence and data
presence. These are to assist the user in identifying right from
thefrontpanelwhetheragivensignalispresentfortransmission
andaidinthetroubleshootingprocessifagiven signalis missing.
RS-232/IR Terminal block pinout
HDCP LED: Will be solid LED when video
input has a HDCP. It will blink when video
input does not have HDCP.
Data in and Data out LED:
It will be on when the unit
detects data signal.
SPDIF & L/R detect LED.
It will be on when the unit detect
the audio input signal.
112
In
12
11
RS232
2
2
Out
2
2
1
I / O
IR
REM
2
1
+5V
In
C
NC
NO
NC
NO
C
Out
AUXRELAY
InIn
11
2
Out
2
DATA
1
2
1
2
DATADATA
IR
LBH-H/O-EAD-RX-ICP
PWR/ LINK
L / RSPDIF
AUDIO
HDMI IN
HDMI
5
OPT
HDMI OUT
AUTO
1
HDCP
SPDIF
L/R
EDID
Loc
Rem

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
Broadata Technical Support, (800) 214-0222
10
3.2 LB-ICP
Front
Digital I/O CH-1
GND
Digital I/O CH-2
GND
GND
Relay 1 Normally Open
Relay 1 Common
Relay 1 Normally Closed
Reserved/Do Not Connect
Reserved/Do Not Connect
Digital I/O LEDs
1=I/O Ch-1
2=I/O Ch-2
Remote LED
(On=Remote)
IR TX LED
(On=IR TX Act.)
}
On=High Level
Reserved/Do Not Connect
Reserved/Do Not Connect
Relay 2 Normally Closed
Relay 2 Common
Relay 2 Normally Open
RS-232 OUT CH-2
RS-232 OUT CH-1
GND
RS-232 IN CH-2
RS-232 IN CH-1
1=Relay 1 ON
2=Relay 2 ON
RS-232 LEDs
1=CH-1 Activity
2=CH-2 Activity

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
3.3 LB-KP8/LB-KP4
Rear
IR OUT for
external emitter IR detector
behind holes
Reset button:
push to reset to
default settings
RJ-45
1 - TX+
2 - TX-
3 - RX+
4 - N/C
5 - N/C
6 - RX-
7 - N/C
8 - N/C
CONFIG/Keypad
1. +12V keypad power
2. RS-232 IN
3. RS-232 OUT
4. GND
IR Learn LED
(ON in IR
Learn mode
DIP SW
Position 1: Local/Remote
(Local=OFF)
Position 2: Reserved
Position 3: Reserved
Position 4: Reserved
Rear
Control RJ-45
Pin 1: RS-232 OUT
Pin 2: RS-232 IN
Pin 3: --no connect--
Pin 4: +12v
Pin 5: +12v
Pin 6: --no connect--
Pin 7: GND
Pin 8: GND

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
Broadata Technical Support, (800) 214-0222
12
Thecable connectionbetween LB-KP8andLB-ICPis shownbelow.
IR
Learner
CONFIG LAN RESET
1
IR Out
1
+12VDC
SW
ON
Standard RJ45
Termination T-568B
2. White / Orange (RS232 In)
3. Orange (RS232 Out)
1. Blue (+12V)
4. Brown (Ground)
1.White/Orange
2.Orange
3.White/Green
4.Blue
5.White/Blue
6.Green
7.White/Brown
8.Brown

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
4.0 LB-ICP WEB SERVER DESCRIPTION
Introduction
The ICP Web Server provides user friendly and intuitive web pages to
configurethevirtual keypadand automationfunctions within theICP. It
alsoprovides webpagesto managethe IRLearner andIRcode import.
A standard web browser can be used to access the web pages.
Accessing Web Server
TheIPaddress ofthe ICP mustbe obtainedinorder toaccessthe Web
Server. There are 2 ways to obtain the IP address of an ICP.
1) Use the IPCONFIG command in the Configuration Port
Command Line Interface to display the unit’s IP address.
2) Use the BCI PC Configuration Program (seeAppendix)
Type in the unit’s IP address in the web browser. The ICP Virtual
Keypad page willbedisplayed. All 8keysof theVirtualKeypad areun-
programmed by default. The keys are configured in the Configure
KeyAction page.

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
Broadata Technical Support, (800) 214-0222
14
Beforeconfiguringthe Virtual Keypad, thesystem first needsto beset
up using the Configure System page. On the top menu bar, click
Configure and then click System. Thisbringsup the ICPLoginpage.
IntheICP LogintypeinadminfortheUseridandadminforthePassword
andthen clickSign in button. TheConfigure System pagewillappear.
See the following section for Configure System page details. Once
logged in, the user is free to open any of the Configure or Settings
pages. The default Password can be changed using the BCI Product
Configuration program.

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
Configure System
TheConfigure System pageis usedtoconfigure thenetworkkeypad,
virtual keypad, RS-232 channels, Digital IO channels and remote unit
types.
On the top menu bar, click Configure and then click System. The
following page will be displayed.

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
Broadata Technical Support, (800) 214-0222
16
Local Unit
The first two lines in this panel show the Local unit type and software
version. Below that is the address setup and status for the Network
Keypad. The next two pull down menus are for selecting the virtual
keypadsize andenablingAutoActionTriggers. Thelast line showsthe
link status.
Network Keypad Address:Enter theIPaddressofthenetworkkeypad
(LB-KP8E or LB-KP16E) if one is present in the system. Use the BCI
Product Configuration program to discover the network keypad’s IP
address.
Network Keypad Status: Shows type of network keypad connected
to ICP.
VirtualKeypadSize: Select8keys or16keys. 8keysoption: maximum
of 10 actions per key. 16 keys option: maximum of 5 actions per key.
AutoAction Triggers: SelectEnable to enablethe autoaction triggers
definedinthe ConfigureAutoAction page. SelectDisable to disable
all auto action triggers.
Link Status: Shows status of link with remote unit.
Local Unit RS-232 Options
This panel is used to configure the local RS-232 channels.
Channel: Select channel 1, 2, 3 (Local Pass-through) or 3 (Remote
Pass-through).
Channel 1/2: RS-232 control channels.
Channel 3 (Local Pass-through): RS-232 pass-through or control
channel. Thischanneldefaultsasacontrolchannel. SeePass-through
Channel below to change to pass-through channel.

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
Channel 3 (Remote pass-through): RS-232 pass-throughchannelon
the remote unit.
Note: This channel is not available if the remote unit is the
LBx-H/DP-EAD-T.
Baud Rate: Select a baud rate from 9600 to 115200 baud.
Flow Control: SelectOn to enable flow control and Off todisable flow
control. Flow control is available only on Channel 1. If flow control is
enabled,Channel2 is nolongeravailable.
End of Line Pattern: Select CR, CR+LF or None for end of line
termination.
Local Unit Digital IO Options
The3pull downmenus inthispanel areused to configurethe DigitalIO
settings. DigitalIOsare inputsby defaultand showupas triggersin the
ConfigureAuto Actions page.
Digital IO Channel: Select channel 1or 2.
Digital IO Direction: Select channel as a digital Input or Output.
If the Digital IO Direction is set to Input, there is an option for Pullup
Resistor.
Pullup Resistor: Select Enable or Disable pull-up resistor.
If the Digital IO Direction is set to Output, there is an option for Digital
Output Mode.
Digital Output Mode: Select TTL fora5V compatibleTTLtype output
orOpen Collector foran opencollectortype output. Anopencollector
type output can be used to implement a contact closure type output.
For example, if a digital output is set to Open Collector, setting the
DigitalOutput State to1 (High) will emulatea switch closureto ground.
Setting the Digital Output State to 0 (Low) will emulate a switch being
open. TheOpenCollectoroutput alsohasanoptionforaPullupResistor.

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
Broadata Technical Support, (800) 214-0222
18
Remote Unit
Thispanelenables the connectionwith the remoteunitand selects the
remote unit type.
Pass-through Channel: SelectICP Mode toenable ICPcontrolof the
local andremote pass-through channels. Select Pass-through mode
toconnect thelocal pass-throughchannel withthe remotepass-through
channel.
Remote Unit: Select the remote unit type. The available remote unit
types are LBx without ICP and LBx-H/DP-EAD-T.
Configure KeyAction
The Configure Key Action page is used to configure the keys virtual
on the virtual keypad. On the 8-key keypad, each function key can be
definedas amacrofor upto 10different actions.Onthe 16-keykeypad,
each function key can be defined as a macro for up to 5 actions. The
available actions are Relay, Digital Output, RS-232, IR, Telnet, Video
InputSelect andKeypad.Note:DigitalOutputactionsare onlyavailable
ifDigitalIOs areconfigured asoutputs in theConfigure System page..
OnthetopmenuclickConfigure andthenclickKeyAction.Thefollowing
page will be displayed.
Function Key: Select the function key F1 through F8 to be defined.

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
Function Key Label: Type in a label name for the selected function
key.
Function Key Mode: Select Standard for a “momentary” type key.
Only one action is assigned to a Standard key. Select Toggle for a
“toggle” type key. A Toggle key has two states: Press and Release.
One set of actions is assigned to the Press state and another set of
actions is assigned to the Release state.
Command Action: Select the action number to be defined. Action 1
throughAction 10 can be defined.
Spacing: Enter the delay desired before the command action.
Action Type: Select the action type. Available types are None,
Relay, Digital Output, RS-232, IR, Telnet, Video Input Select and
Keypad.
Relay Options
Relay Channel: Select the relay channel 1or 2.
Relay State: Select the relay channel state, On (energized) or Off
(de-energized).

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
Broadata Technical Support, (800) 214-0222
20
Digital Output Options
Digital Output Channel: Select the digital output channel 1or 2.
Note: this option is not available if both Digital IO channels are set to
Inputs in Configure System page.
Digital Output State: Select the digital output state: 1 (High) or 0
(Low).

LBH-H/O-EAD-R-ICPUserManual
Link BridgeTM HBaseT/HDMI Receiver System w/ExternalAudio and Inline Control Processor
RS-232 Options
RS-232 Channel: Select channel 1, 2, or 3 (Remote).
Transmit String: Type in the text string to be transmitted. Strings are
terminatedwithCR, CR+LFornotermination,dependingonthe selection
made in Configure System page. Characters enclosed by <> will be
treated as hex. For example to transmit 00h enter <00>.
Table of contents