3
40248 11_10
GSM Modem
UCM-93/2
SIM Card: 2)
SIM card holder: Slot with a simple click release function placed on the top of the module.
Voltages: Only 3V supported.
Indicator: Red LED on front.
Functions: LED off Power off.
LED on Power on - connecting to network.
LED flashing slowly Power on - idle mode.
LED flashing rapidly Power on - transmission mode.
Power supply:
Supply voltage: 12-48V DC (10,5-60VDC). IMPORTANT NOTE 3)
The modem is protected against voltages above 60VDC.
Consumptions (12V): Input max. peak current: 1A
Input average current in com. mode: 0,25A
Input average current in idle mode: 20mA
Connector: Removable screw terminal.
Environmental conditions:
Ambient temperature: Operating conditions: -10 - +55°C
Storage conditions: -25 - +70°C
Dry heat: IEC 68-2.2, Bb test.
Cold: IEC 68-2.1, Ab test.
Change of temp.: IEC 68-2.14, Na/Nb test.
Damp heat cyclic: IEC 68-2.30, Db test.
Damp test: IEC 68-2.56, Cb test.
Sinusoidal vibration: IEC 68-2.6, Fc test.
random vibration: IEC 68-3.36, Fdb test.
Approvals: CTR19 and CTR20
Protection: IP20
Mounting: 35mm DIN-rail, EN50022.
Housing: Anodized aluminium with plastic ends. According to DIN 43880.
Dimensions: HxWxD: 80 (+connectors)x108x62mm.
CONTROLLING THE MODEM / AT COMMANDS
The UCM-93/2 are controlled via an AT command set. Please consult the Getting Started document supplied with the
modem. AT Command Manual is available on our homepage.
NOTES
1) Audio signal will not be available in UCM-93/2.
2) If the UCM-93/2 has to be used with RTU-modules the PIN code must be disabled before use. Can be done with
a normal mobile GSM cellular phone or with a PC with a terminal program and the AT command AT+CPIN=XXXX.
Note also that the account must be ordered specially for supporting data at your provider.
3) IMPORTANT NOTE: The power supply MUST be capable of deliver the peak current required by the GSM modem,
otherwise you might have problems during power up or the communication will fail occasionally.