Bronson VC Series User manual

Instruction Manual
Bronson VC Series
0-300V AC Variable Voltage Transformer
Models: VC 1000, VC 3000, VC 5000, VC 10000
English

0-300V AC Variable Voltage Transformer
Bronson VC Series
0-300V AC Variable Voltage Transformer
Instruction Manual
Before operating this product, please read these instructions carefully
Thank you for choosing this Bronson VC variable AC voltage transformer. This
voltage converter can convert an incoming single-phase AC power of 230 V to an
AC power of approximately 0 to 300 V (depending on the exact input voltage
level available). This manual is a guide to install and use the variable transformer.
It includes important safety instructions for the operation and correct installation
of the transformer. If you should have any problems with the transformer, please
refer to this manual before contacting customer service.
Models: VC 1000, VC 3000, VC 5000, VC 10000

1. Bronson VC 1000
a. Front of the VC 1000
Bronson VC Series
0-300V AC Variable Voltage Transformer
Instruction Manual
3
AC input IEC port
Digital voltage
output display
ON/OFF breaker switch
Case ground connection point
L/N output terminals

4
b. Rear of the VC 1000 with EU socket
c. Rear of the VC 1000 with UK socket
EU output socket
UK output socket
Bronson VC Series
0-300V AC Variable Voltage Transformer
Instruction Manual

2. Bronson VC 3000
5
d. Top of the VC 1000
a. Front of the VC 3000
Variable Output Control
(Note that indicated output levels are intended as a rough estimate and exact AC output will depend
on the input and current output and will be displayed with high accuracy on the digital display.)
Bronson VC Series
0-300V AC Variable Voltage Transformer
Instruction Manual
Input power cable
Digital voltage
output display
Circuit breaker
Case ground connection point
L/N output terminals

6
b. Rear of the VC 3000 with EU socket
Bronson VC Series
0-300V AC Variable Voltage Transformer
Instruction Manual
EU output socket
UK output socket
c. Rear of the VC 3000 with UK socket

3. Bronson VC 5000
7
d. Top of the VC 3000
a. Front of the VC 5000
Variable Output Control
(Note that indicated output levels are intended as a rough estimate and exact AC output will depend
on the input and current output and will be displayed with high accuracy on the digital display.)
Bronson VC Series
0-300V AC Variable Voltage Transformer
Instruction Manual
L/N input terminals
Digital voltage
output display
Circuit breaker
Case ground connection point
L/N output terminals

8
b. Top of the VC 5000
Bronson VC Series
0-300V AC Variable Voltage Transformer
Instruction Manual
4. Bronson VC 10000
a. Front of the VC 10000
L/N input terminals
Digital voltage
output display
Case ground connection point
L/N output terminals
Variable Output Control
(Note that indicated output levels are intended as a rough estimate and exact AC output will depend
on the input and current output and will be displayed with high accuracy on the digital display.)

9
b. Top of the VC 10000
Bronson VC Series
0-300V AC Variable Voltage Transformer
Instruction Manual
5. Technical Specifications
Variable Output Control
(Note that indicated output levels are intended as a rough estimate and exact AC output will depend
on the input and current output and will be displayed with high accuracy on the digital display.)
Model Frequency Rated
Input
Voltage
Rated
Input
Voltage
Rated
Current
Output
AC Phase Efficiency
VC 1000 50/60Hz 220V 0-300V Single >90% 4A
VC 3000 50/60Hz 220V 0-300V Single >90% 12A
VC 5000 50/60Hz 220V 0-300V Single >90% 20A
VC 10000 50/60Hz 220V 0-300V Single >90% 40A

10
Bronson VC Series
0-300V AC Variable Voltage Transformer
Instruction Manual
6.Operation of the Variable Voltage Transformer
a. Installation of the variable tranformer
b. Connect transformer to electrical mains
(1) Always place the transformer in an environment that is:
- Well ventilated.
- Not exposed to direct sunlight or heat sources.
- Out of reach of children.
- Away from water moisture, oil or grease.
- Away from any ammable substance.
(2) Check the specications of the electrical appliances to be used with the transformer.
Make sure that the combined total wattage ratings of all the appliances to be used
simultaneously won't exceed the maximum amp rating of the transformer.
(3) Make sure all appliances are turned off before connection.
(4) Connect your appliance or appliances to the transformer. If your device has an earth
connection and you connect the device via the screw terminals, you have to connect
it to the earth connection of the transformer.
(1) Set the desired output voltage.
(2) Switch on either the voltage transformer or the power supply.
(3) Switch on the appliances one by one. Note that after applying the load, the voltage level
can drop and may need to be readjusted.
(1) The VC 1000 and VC 3000 models have to be connected to the power supply via a
socket. The VC 5000 and VC 10000 models have to be connected to the power
supply using screw terminals.
(2) The input voltage must be disconnected before connecting the VC 5000 and VC 10000 models.
(3) Connect the variable transformer to the power supply. Regardless of whether you
connect the variable transformer via the IEC socket or via the screw terminals, make
sure that the ground connection of the variable transformer is connected.
(4) Make sure that the input cable has a sufcient cable cross-section.
c. Connect the power supply

11
7. Caution
To reduce the risk of e le ct ric shock, do n ot re mo ve t he c over of this de vi ce . Th ere a re no u ser service ab le
parts inside. All repairs should be handled by a qualied technician.
To reduce the risk of e le ct rical shock , do n ot e xp ose the varia bl e tr an sformer to ra in , mo isture or liquid s.
This unit is only suitable for indoor applications in dry rooms.
Operate this voltage regulator only with dry clothes and hands.
Do not cover or enclose the ventilation openings of this voltage regulator. Allow for the free ow of
air for cooling.
Do not overload this voltage regulator beyond its maximum amp rating.
Do not attempt to change internal wiring of this variable transformer
Avoid strong shaking, vibrations, and tipping over this voltage transformer
Bronson VC Series
0-300V AC Variable Voltage Transformer
Instruction Manual
The circuit breaker trips and opens the circuit if the transformer is over loaded with too
much power from the connected appliances. If this happens unplug the transformer from
the wall outlet and remove all connected appliances. Wait a few minutes. Then re-connect
the appliances. Ensure that the appliances are turned off before you connect them. Ensure
that the combined rated power of all appliances does not exceed the power rating of the
transformer. Then connect the transformer to the power supply. Switch on the transformer
and the connected appliances one by one.
d. When the circuit breaker switch for overload protection is tripped
Models: VC 3000, VC 5000

9. Disposal
Bronson VC Series
0-300V AC Variable Voltage Transformer
Instruction Manual
Disposal of waste equipment by users in private households in the European Union
8. Declaration of Conformity
Company: Mangrove GmbH
Adresse: Bouchéstraße 12
12435 Berlin
Germany
declares that the following products
Bronson VC 1000, VC 3000, VC 5000, VC 10000
are in conformity with the requirements of the following directives of the
European Union:
EMC Directive 2014/30/EU with the following harmonised standards:
EN 61000-6-1:2007
EN 61000-6-3:2007+A1:2011+AC:2012
EN 61000-3-2:2014
EN 61000-3-3:2013
Low Voltage Directive 2014/35/EU with the following harmonised standards:
EN 61558-1: 2005+ A1: 2009
EN 61558-2-13:2009
This symbol on the product or on its packaging indicates that this product must not be
disposed of with your other household waste. Instead, it is your responsibility to dispose
of your waste equipment by handing it over to a designated collection point for the
recycling of waste electrical and electronic equipment. The separate collection and
recycling of your waste equipment at the time of disposal will help to conserve natural
resources and ensure that it is recycled in a manner that protects human health and the
environment. For more information about where you can drop off your waste equipment for
recycling, please contact your local city ofce, your household waste disposal service or the
shop where you purchased the product.
Mangrove GmbH
Bouchéstraße 12
12435 Berlin
Germany

Bedienungsanleitung
Bronson VC Serie
0-300V AC Stelltransformator
German
Modelle: VC 1000, VC 3000, VC 5000, VC 10000

0-300V AC Stelltransformator
Bronson VC Series
0-300V AC Stelltransformator
Bedienungsanleitung
Bevor Sie das Produkt nutzen, lesen Sie bitte sorgfältig dieses Handbuch
Vielen Dank, dass Sie sich für diesen Bronson VC Wechselspannungs-Stell-
transformator entschieden haben. Dieser Spannungswandler kann eine
eingehende einphasige Wechselstromleistung von 230V in eine Wechsel-
stromleistung von ungefähr 0 bis 300V umwandeln (abhängig vom genauen
verfügbaren Eingangsspannung). Dieses Handbuch ist eine Anleitung zur
Installation und Verwendung des Stelltransformators. Es enthält wichtige
Sicherheitshinweise für den Betrieb und die korrekte Installation des Transfor-
mators. Sollten Sie Probleme mit dem Transformator haben, lesen Sie bitte
dieses Handbuch, bevor Sie sich an den Kundendienst wenden.
Modelle: VC 1000, VC 3000, VC 5000, VC 10000

1. Bronson VC 1000
a. Vorderseite des VC 1000
15
IEC-Wechselstromanschluss
Digitale
Ausgangsspannungsanzeige
EIN-/AUS-Schalter
Masseanschluss des Gehäuses
L/N Ausgangsanschlüsse
Bronson VC Series
0-300V AC Stelltransformator
Bedienungsanleitung

16
b. Rückseite des VC 1000 mit EU Buchse
c. Rückseite des VC 1000 mit UK Buchse
EU Ausgangsbuchse
UK Ausgangsbuchse
Bronson VC Series
0-300V AC Stelltransformator
Bedienungsanleitung

Bronson VC Series
0-300V AC Stelltransformator
Bedienungsanleitung
2. Bronson VC 3000
17
d. Oberseite des VC 1000
a. Vorderseite des VC 3000
Ausgangssteuerung
(Beachten Sie, dass die angezeigten Ausgangsspannung eine Näherung darstellt und die genaue
Ausgangsspannung vom Stromeingang und vom Stromausgang abhängt und auf der Digitalanzeige
mit hoher Genauigkeit angezeigt wird.)
Anschlusskabel
Digitale
Ausgangsspannungsanzeige
Schutzschalter
Masseanschluss des Gehäuses
L/N Ausgangsanschlüsse

18
b. Rückseite des VC 3000 mit EU Buchse
EU Ausgangsbuchse
UK Ausgangsbuchse
c. Rückseite des VC 3000 mit UK Buchse
Bronson VC Series
0-300V AC Stelltransformator
Bedienungsanleitung

3. Bronson VC 5000
19
d. Oberseite des VC 3000
a. Front of the VC 5000
Ausgangssteuerung
(Beachten Sie, dass die angezeigten Ausgangsspannung eine Näherung darstellt und die genaue
Ausgangsspannung vom Stromeingang und vom Stromausgang abhängt und auf der Digitalanzeige
mit hoher Genauigkeit angezeigt wird.)
L/N Ausgangsanschlüsse
terminals
Digitale
Ausgangsspannungsanzeige
Schutzschalter
Masseanschluss des Gehäuses
L/N Eingangsanschlüsse
Bronson VC Series
0-300V AC Stelltransformator
Bedienungsanleitung

20
b. Oberseite des VC 5000
4. Bronson VC 10000
a. Vorderseite des VC 10000
L/N Eingangsanschlüsse
Digitale
Ausgangsspannungsanzeige
Masseanschluss des Gehäuses
L/N Ausgangsanschlüsse
Ausgangssteuerung
(Beachten Sie, dass die angezeigten Ausgangsspannung eine Näherung darstellt und die genaue
Ausgangsspannung vom Stromeingang und vom Stromausgang abhängt und auf der Digitalanzeige
mit hoher Genauigkeit angezeigt wird.)
Bronson VC Series
0-300V AC Stelltransformator
Bedienungsanleitung
This manual suits for next models
4
Table of contents
Languages:
Other Bronson Transformer manuals